Quantitation of normal canine hippocampus formation volume: correlation of MRI with gross histology.

Abstract:

:The hippocampal formation possesses an important role in the development and maintenance of short-term memory. In this study, magnetic resonance imaging (MRI) and gross histology were used to quantify the volume of the hippocampal formation in canines. High resolution MRI, using 1 mm thick slices and an intraplanar resolution of 0.35 mm was performed at 2.0 T both in vivo and in vitro following in situ fixation. The volumes of the hippocampal formations were determined from MR images and compared to those obtained from one mm thick gross histologic sections. The average volume of the canine hippocampal formation, measured from in vivo and in vitro MR images was 476.0 +/- 79.5 and 467.3 +/- 53.7 mm3, respectively. Determined from gross histology, the volume of the hippocampal formation was 463.6 +/- 24.1 mm3. Quantitation of the canine hippocampal formation using in vivo MRI showed good correlation with in vitro MRI and histology, verifying the reliability and reproducibility of in vivo MRI measurements. High resolution MRI using 1 mm thick slices through the whole canine hippocampal formation is necessary for accurate volume determination of a structure of this size.

journal_name

Magn Reson Imaging

authors

Vullo T,Deo-Narine V,Stallmeyer MJ,Gomez DG,Cahill PT

doi

10.1016/0730-725x(95)02083-6

subject

Has Abstract

pub_date

1996-01-01 00:00:00

pages

657-62

issue

6

eissn

0730-725X

issn

1873-5894

pii

0730-725X(95)02083-6

journal_volume

14

pub_type

杂志文章
  • Theoretical considerations in measurement of time discrepancies between input and myocardial time-signal intensity curves in estimates of regional myocardial perfusion with first-pass contrast-enhanced MRI.

    abstract::The purpose of this study was to develop a method to determine time discrepancies between input and myocardial time-signal intensity (TSI) curves for accurate estimation of myocardial perfusion with first-pass contrast-enhanced MRI. Estimation of myocardial perfusion with contrast-enhanced MRI using kinetic models req...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.06.015

    authors: Natsume T,Ishida M,Kitagawa K,Nagata M,Sakuma H,Ichihara T

    更新日期:2015-11-01 00:00:00

  • Diffusion-weighted imaging versus superparamagnetic iron oxide (SPIO)-enhanced MRI: exclusive and combined values in the assessment of hepatic metastases.

    abstract:PURPOSE:The purpose was to validate diffusion-weighted imaging (DWI) in the assessment of hepatic metastases compared with superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance imaging. MATERIALS AND METHODS:For 21 consecutive patients with 160 metastases from extrahepatic malignancy and 25 benign focal lesi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.12.007

    authors: Kim H,Yu JS,Cho ES,Chung JJ,Kim JH,Kim DJ,Ahn JH,Kim KW

    更新日期:2012-05-01 00:00:00

  • 23Na magnetic resonance imaging: distribution of brine in muscle.

    abstract::Magnetic resonance imaging (MRI) has been used to characterize tissues in morphological studies. Here, 23Na NMR imaging was used to study the distribution in muscle of brine (5 M NaCl), injected before onset of rigor mortis. First, the distribution of brine was monitored in excised muscle from rabbits for 6 hr followi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92360-4

    authors: Renou JP,Benderbous S,Bielicki G,Foucat L,Donnat JP

    更新日期:1994-01-01 00:00:00

  • Spectroscopic imaging of the brain with phased-array coils at 3.0 T.

    abstract::The goal of this study was to develop and evaluate high-resolution magnetic resonance spectroscopic imaging (MRSI) utilizing the gains in signal-to-noise ratio (SNR) provided by combining higher magnetic field with high-sensitivity phased-array (PA) coils. We investigated the maximum improvement in spatial resolution ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.019

    authors: Xu D,Chen AP,Cunningham C,Osorio JA,Nelson SJ,Vigneron DB

    更新日期:2006-01-01 00:00:00

  • Compensation of susceptibility-induced signal loss in echo-planar imaging for functional applications.

    abstract::Functional magnetic resonance imaging favors the use of multi-slice gradient-recalled echo-planar imaging due to its short image acquisition times, whole brain coverage and sensitivity to BOLD contrast. However, despite its advantages, gradient-recalled echo-planar imaging also is sensitive to static magnetic field gr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00199-5

    authors: Cordes D,Turski PA,Sorenson JA

    更新日期:2000-11-01 00:00:00

  • Analysis of microporosity and setting of reactive powder concrete by proton nuclear relaxation.

    abstract::The proton spin-lattice relaxation measured at several frequencies leads to a resolved distribution of four Tli for reactive powder concrete (RPC). The typical Tli frequency dependences are quantitatively interpreted by a biphasic fast exchange model and a proton nuclear relaxation of hydrated paramagnetic ions at the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00063-0

    authors: Philippot S,Korb JP,Petit D,Zanni H

    更新日期:1998-06-01 00:00:00

  • Quantitation of non-Einstein diffusion behavior of water in biological tissues by proton MR diffusion imaging: synthetic image calculations.

    abstract::The non-Einstein diffusion behavior of water in a model biological tissue system, intact duck embryos, has been investigated by the use of an in vivo proton pulsed-gradient spin-echo (PGSE) MR imaging technique. Multiple-frame MR images of the intact duck embryos and control solution (0.5 mM CuSO4 doped water) were ac...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90476-t

    authors: Cheng KH

    更新日期:1993-01-01 00:00:00

  • Artificial intelligence in medical imaging.

    abstract::The medical specialty radiology has experienced a number of extremely important and influential technical developments in the past that have affected how medical imaging is deployed. Artificial intelligence (AI) is potentially another such development that will introduce fundamental changes into the practice of radiol...

    journal_title:Magnetic resonance imaging

    pub_type: 社论

    doi:10.1016/j.mri.2019.12.006

    authors: Gore JC

    更新日期:2020-05-01 00:00:00

  • Is 'virtual histology' the next step after the 'virtual autopsy'? Magnetic resonance microscopy in forensic medicine.

    abstract:AIM:The study aimed to validate magnetic resonance microscopy (MRM) studies of forensic tissue specimens (skin samples with electric injury patterns) against the results from routine histology. METHODS AND RESULTS:Computed tomography and magnetic resonance imaging are fast becoming important tools in clinical and fore...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.08.019

    authors: Thali MJ,Dirnhofer R,Becker R,Oliver W,Potter K

    更新日期:2004-10-01 00:00:00

  • MR characteristics of neoplasms and vascular malformations associated with epilepsy.

    abstract::We assessed the magnetic resonance (MR) imaging characteristics of two categories of epileptogenic substrates, neoplasms, and vascular malformations, to determine MR sensitivity and typical imaging features. A blinded retrospective analysis was performed on MR scans from 41 patients who had a neoplasm or vascular malf...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02026-p

    authors: Bronen RA,Fulbright RK,Spencer DD,Spencer SS,Kim JH,Lange RC

    更新日期:1995-01-01 00:00:00

  • Parametric multiecho proton spectroscopic imaging: application to the rat brain in vivo.

    abstract::A parametric multiecho variant of proton spectroscopic imaging (SI) is presented using a multiecho SI sequence with uniform phase-encoding of all echoes within each echo train. The acquisition of SI data sets at different echo times (TE) increases the amount of information obtained within the same total measuring time...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00027-e

    authors: Dreher W,Leibfritz D

    更新日期:1995-01-01 00:00:00

  • Non-enhanced magnetic resonance imaging of the small bowel at 7 Tesla in comparison to 1.5 Tesla: First steps towards clinical application.

    abstract:OBJECTIVE:To perform non-enhanced (NE) magnetic resonance imaging (MRI) of the small bowel at 7 Tesla (7T) and to compare it with 1.5 Tesla (1.5T). MATERIAL AND METHODS:Twelve healthy subjects were prospectively examined using a 1.5T and 7T MRI system. Coronal and axial true fast imaging with steady-state precession (...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.11.012

    authors: Hahnemann ML,Kraff O,Maderwald S,Johst S,Orzada S,Umutlu L,Ladd ME,Quick HH,Lauenstein TC

    更新日期:2016-06-01 00:00:00

  • Relationship between cancellous bone induced magnetic field and ultrastructure in a rat ovariectomy model.

    abstract::The site-dependent variations in trabecular bone morphology were studied in the rat tibia by magnitude and phase difference three-dimensional nuclear magnetic resonance microscopy and image processing, and the implications of ovariectomy were evaluated. Specimens excised from the proximal tibial metaphysis in ovariect...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00107-1

    authors: Takahashi M,Wehrli FW,Hwang SN,Wehrli SL

    更新日期:2000-01-01 00:00:00

  • Off-resonance binomial preparatory pulse technique for high sensitivity MRI of H2O17.

    abstract::H2O17 is a freely diffusible tracer and naturally occurring isotope of O16 detectable by MRI and has been shown to be useful for assessing cerebral perfusion in animal studies using direct and indirect MR detection techniques. However, earlier MR techniques are either not sensitive to changes in small concentrations o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.09.005

    authors: Sood R

    更新日期:2004-02-01 00:00:00

  • Automated segmentation of lateral ventricles from human and primate magnetic resonance images using cognition network technology.

    abstract::Automatic segmentation of different types of tissue from magnetic resonance images is of great importance for clinical and research applications, particularly large-scale and longitudinal studies of brain pathology. We developed a fully automated algorithm for the segmentation of lateral ventricles from cranial magnet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.08.013

    authors: Schönmeyer R,Prvulovic D,Rotarska-Jagiela A,Haenschel C,Linden DE

    更新日期:2006-12-01 00:00:00

  • Lee-Goldburg solid-state imaging.

    abstract::A new approach to solid-state imaging (SSI) is presented. The method relies on narrowing the resonance line using the Lee-Goldburg sequence. The technique is easy to implement in practice and may find widespread applications in materials science. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90409-s

    authors: De Luca F,Lugeri N,De Simone BC,Maraviglia B

    更新日期:1992-01-01 00:00:00

  • Functional MR imaging in the awake monkey: effects of motion on dynamic off-resonance and processing strategies.

    abstract::Functional MR imaging of the alert, behaving monkey is being used more and more often to detect activation patterns and guide electrophysiological research investigating the neural basis of behavior. Several labs have reported fMRI data from the awake monkey, but none of them has studied and systematically corrected t...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.002

    authors: Pfeuffer J,Shmuel A,Keliris GA,Steudel T,Merkle H,Logothetis NK

    更新日期:2007-07-01 00:00:00

  • Sampling time effects on signal-to-noise and contrast-to-noise ratios in spin-echo MRI.

    abstract::This work discusses the effect of sampling time on noise, signal-to-noise and contrast-to-noise ratios in magnetic resonance imaging. A simple imaging experiment is performed to demonstrate the effect of sampling time on noise, confirming theoretical expectations that doubling the sampling time while decreasing the re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90481-4

    authors: Hendrick RE

    更新日期:1987-01-01 00:00:00

  • Reproducibility of MRI-derived measurements of right ventricular volumes and myocardial mass.

    abstract::Magnetic resonance (MR) imaging has been shown to provide accurate measurements of right ventricular (RV) volumes and myocardial mass. The purpose of this study was to evaluate the reproducibility of MR imaging, which in clinical practice may be as important as its absolute accuracy. The reproducibility of MR imaging ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)00076-f

    authors: Pattynama PM,Lamb HJ,Van der Velde EA,Van der Geest RJ,Van der Wall EE,De Roos A

    更新日期:1995-01-01 00:00:00

  • Characteristics of geometric distortion correction with increasing field-of-view in open-configuration MRI.

    abstract::Open-configuration magnetic resonance imaging (MRI) systems are becoming increasingly desirable for musculoskeletal imaging and image-guided radiotherapy because of their non-claustrophobic configuration. However, geometric image distortion in large fields-of-view (FOV) due to field inhomogeneity and gradient nonlinea...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.02.007

    authors: Hong C,Lee DH,Han BS

    更新日期:2014-07-01 00:00:00

  • Phase detection and contrast loss in magnetic resonance imaging.

    abstract::Several recent articles have assessed the relative efficiency of nuclear magnetic resonance (NMR) pulse sequences. One consideration that has received little attention is the effect on image contrast of displaying images without information on the sign of the reconstructed signals. The radiofrequency receivers current...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(84)90193-0

    authors: Hendrick RE,Nelson TR,Hendee WR

    更新日期:1984-01-01 00:00:00

  • Regional variations in MR relaxation of hip joint cartilage in subjects with and without femoralacetabular impingement.

    abstract::The objective of this study was to analyze regional variations of magnetic resonance (MR) relaxation times (T1ρ and T2) in hip joint cartilage of healthy volunteers and subjects with femoral acetabular impingement (FAI). Morphological and quantitative images of the hip joints of 12 healthy volunteers and 9 FAI patient...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.01.009

    authors: Subburaj K,Valentinitsch A,Dillon AB,Joseph GB,Li X,Link TM,Vail TP,Majumdar S

    更新日期:2013-09-01 00:00:00

  • Voxel- and atlas-based analysis of diffusion tensor imaging may reveal focal axonal injuries in mild traumatic brain injury -- comparison with diffuse axonal injury.

    abstract:BACKGROUND:The diagnosis and management of mild traumatic brain injury (MTBI) continue to be subjects of debate, with varying opinions regarding the extent to which tissue-based impairments versus the impacts of other stressors cause ongoing disability. Detecting areas of the brain with abnormalities that can explain s...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.12.018

    authors: Kasahara K,Hashimoto K,Abo M,Senoo A

    更新日期:2012-05-01 00:00:00

  • Intravoxel incoherent imaging of renal fibrosis induced in a murine model of unilateral ureteral obstruction.

    abstract:PURPOSE:To evaluate non-invasive imaging biomarkers for assessing renal fibrosis. DWI is used to assess renal function; intravoxel incoherent motion (IVIM) provides additional measures of perfusion-related diffusion (D*, blood flow; f, perfusion fraction). We aim to determine if reduced ADC seen in renal fibrosis is at...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.07.012

    authors: Hennedige T,Koh TS,Hartono S,Yan YY,Song IC,Zheng L,Lee WS,Rumpel H,Martarello L,Khoo JB,Koh DM,Chuang KH,Thng CH

    更新日期:2015-12-01 00:00:00

  • Rapid assessment of regional and global left ventricular function using three-dimensional k-t BLAST imaging.

    abstract:OBJECTIVE:To test if three-dimensional (3D) cine spatial frequency-temporal frequency Broad-use Linear Acquisition Speed-up Technique (k-t BLAST) is suitable for rapid evaluation of global and regional left ventricular (LV) functional parameters and to evaluate the influence of gadolinium administration. MATERIALS AND...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.01.027

    authors: Huber S,Muthupillai R,Mojibian H,Cheong B,Kouwenhoven M,Flamm SD

    更新日期:2008-07-01 00:00:00

  • In-plane flow velocity quantification along the phase encoding axis in MRI.

    abstract::In-plane flow quantification in MRI offers the potential for assessing vessel patency, and both volume flow rate and flow velocity. These techniques will have definite future impact on MR angiography. The method used in this paper employs motion artifact suppression technique (MAST) gradients to refocus spins travelli...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90409-2

    authors: Duerk JL,Pattany PM

    更新日期:1988-05-01 00:00:00

  • Quantitative SENSE-MRSI of the human brain.

    abstract:PURPOSE:To develop a method for estimating metabolite concentrations using phased-array coils and sensitivity-encoded (SENSE) magnetic resonance spectroscopic images (MRSI) of the human brain. MATERIALS AND METHODS:The method is based on the phantom replacement technique and uses receive coil sensitivity maps and body...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.11.003

    authors: Bonekamp D,Smith MA,Zhu H,Barker PB

    更新日期:2010-04-01 00:00:00

  • A computer algorithm for the simulation of any nuclear magnetic resonance (NMR) imaging method.

    abstract::More than a dozen Nuclear Magnetic Resonance (NMR) imaging methods have been described using different radio-frequency pulse sequences, magnetic field gradient variations, and data processing. In order to have a theoretical understanding in the most general case, we have conceived a computer program for the simulation...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(84)90065-1

    authors: Bittoun J,Taquin J,Sauzade M

    更新日期:1984-01-01 00:00:00

  • MR imaging of pterygoid muscle inflammation.

    abstract::A case report of trismus after a dental procedure is evaluated by MR imaging. The medial and lateral pterygoid muscles showed inflammatory changes. Etiologies of trismus are reviewed. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90148-u

    authors: Ciacchella AP,Higgins WL

    更新日期:1990-01-01 00:00:00

  • Magnetic resonance imaging at frequencies below 1 kHz.

    abstract::Within the magnetic resonance imaging (MRI) community the trend is going to higher and higher magnetic fields, ranging from 1.5 T to 7 T, corresponding to Larmor frequencies of 63.8-298 MHz. Since for high-field MRI the magnetization increases with the applied magnetic field, the signal-to-noise-ratio increases as wel...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.014

    authors: Hilschenz I,Körber R,Scheer HJ,Fedele T,Albrecht HH,Mario Cassará A,Hartwig S,Trahms L,Haase J,Burghoff M

    更新日期:2013-02-01 00:00:00