Dynamic contrast-enhanced 3D breath hold MRA using a multiple variable orientation slab acquisition.

Abstract:

:With the conventional 3D MR angiographic sequences, it is difficult to prescribe multiple phases in different orientations, though multiple phases may be prescribed in the same orientation as the initial scan. Magnetic resonance angiography (MRA) was performed in which three slabs were prescribed in different orientations and were acquired in a sequential measurement. A fixed delay of 8 s between the slabs was used to prepare patients to hold their breath for subsequent measurements. All subjects tolerated the entire breath hold examination. The results were easily reproducible and yielded high-resolution 3-dimensional images in various planes.

journal_name

Magn Reson Imaging

authors

Shetty AN,Bis KG

doi

10.1016/s0730-725x(99)00003-x

subject

Has Abstract

pub_date

1999-07-01 00:00:00

pages

837-41

issue

6

eissn

0730-725X

issn

1873-5894

pii

S0730725X9900003X

journal_volume

17

pub_type

杂志文章
  • GRAPPA-based susceptibility-weighted imaging of normal volunteers and patients with brain tumor at 7 T.

    abstract::Susceptibility-weighted imaging (SWI) is a valuable technique for high-resolution imaging of brain vasculature that greatly benefits from the emergence of higher field strength MR scanners. Autocalibrating partially parallel imaging techniques can be employed to reduce lengthy acquisition times as long as the decrease...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.08.003

    authors: Lupo JM,Banerjee S,Hammond KE,Kelley DA,Xu D,Chang SM,Vigneron DB,Majumdar S,Nelson SJ

    更新日期:2009-05-01 00:00:00

  • Factors influencing contrast in fast spin-echo MR imaging.

    abstract::Multi-echo pulse sequences for producing T2-weighted images in much reduced imaging times have recently been developed for routine clinical use. A number of recent articles have described the contrast obtained with fast spin-echo (FSE) sequences and have generally indicated that they depict tissues very similarly to c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(92)90001-g

    authors: Constable RT,Anderson AW,Zhong J,Gore JC

    更新日期:1992-01-01 00:00:00

  • Application of machine learning methods to describe the effects of conjugated equine estrogens therapy on region-specific brain volumes.

    abstract::Use of conjugated equine estrogens (CEE) has been linked to smaller regional brain volumes in women aged ≥65 years; however, it is unknown whether this results in a broad-based characteristic pattern of effects. Structural magnetic resonance imaging was used to assess regional volumes of normal tissue and ischemic les...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.mri.2010.12.001

    authors: Casanova R,Espeland MA,Goveas JS,Davatzikos C,Gaussoin SA,Maldjian JA,Brunner RL,Kuller LH,Johnson KC,Mysiw WJ,Wagner B,Resnick SM,Women's Health Initiative Memory Study.

    更新日期:2011-05-01 00:00:00

  • Validation of estimated 3D temperature maps during hepatic cryo surgery.

    abstract::A simple model for estimating temperature distribution within the frozen region during cryo ablation was tested for accuracy. Freezing experiments were conducted in both ex vivo and in vivo porcine livers. Temperature was measured during freezing using a fiber-optic temperature sensor. Three-dimensional MR images were...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00389-7

    authors: Samset E,Mala T,Edwin B,Gladhaug I,Søreide O,Fosse E

    更新日期:2001-06-01 00:00:00

  • MRI findings in pulmonary sarcoidosis.

    abstract::Postero-anterior radiographs and magnetic resonance imaging (MRI) of the chest were performed in nine biopsy proven cases of sarcoidosis. MRI was more sensitive than a postero-anterior chest roentgenogram in detecting hilar and mediastinal adenopathy but less informative in detecting pleural and parenchymal disease. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90131-2

    authors: Craig DA,Colletti PM,Ratto D,Gordonson JS,Raval JK,Sharma OP

    更新日期:1988-09-01 00:00:00

  • AG-013736, a novel inhibitor of VEGF receptor tyrosine kinases, inhibits breast cancer growth and decreases vascular permeability as detected by dynamic contrast-enhanced magnetic resonance imaging.

    abstract::Dynamic contrast-enhanced MRI (DCE-MRI) was used to noninvasively evaluate the effects of AG-03736, a novel inhibitor of vascular endothelial growth factor (VEGF) receptor tyrosine kinases, on tumor microvasculature in a breast cancer model. First, a dose response study was undertaken to determine the responsiveness o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.09.041

    authors: Wilmes LJ,Pallavicini MG,Fleming LM,Gibbs J,Wang D,Li KL,Partridge SC,Henry RG,Shalinsky DR,Hu-Lowe D,Park JW,McShane TM,Lu Y,Brasch RC,Hylton NM

    更新日期:2007-04-01 00:00:00

  • Non-Gaussian diffusion MRI assessment of brain microstructure in mild cognitive impairment and Alzheimer's disease.

    abstract::We report the first application of a novel diffusion-based MRI method, called diffusional kurtosis imaging (DKI), to investigate changes in brain tissue microstructure in patients with mild cognitive impairment (MCI) and AD and in cognitively intact controls. The subject groups were characterized and compared in terms...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.02.008

    authors: Falangola MF,Jensen JH,Tabesh A,Hu C,Deardorff RL,Babb JS,Ferris S,Helpern JA

    更新日期:2013-07-01 00:00:00

  • Three-dimensional magnetic resonance imaging after ultrasonography for assessment of fetal gastroschisis.

    abstract::A 24-year-old woman (Gravida I, Para I) at estimated 32 weeks of pregnancy was referred to our department for evaluation of a suspected fetal gastroschisis. Ultrasound scan revealed multiple loops of dilated bowel outside the fetal abdomen and absence of membrane surrounding the herniated loops of the intestines. Thre...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.006

    authors: Sasaki Y,Miyamoto T,Hidaka Y,Satoh H,Takuma N,Sengoku K,Sugimori H,Inaoka T,Aburano T

    更新日期:2006-02-01 00:00:00

  • Technical evaluation of in vivo abdominal fat and IMCL quantification using MRI and MRSI at 3 T.

    abstract:OBJECTIVES:The objectives of this study were to develop protocols that measure abdominal fat and calf muscle lipids with magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), respectively, at 3 T and to examine the correlation between these parameters and insulin sensitivity. MATERIALS AND METHOD...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.06.006

    authors: Li X,Youngren JF,Hyun B,Sakkas GK,Mulligan K,Majumdar S,Masharani UB,Schambelan M,Goldfine ID

    更新日期:2008-02-01 00:00:00

  • Equivalent cross relaxation rate image for decreasing a false negative case of sentinel lymph node biopsy.

    abstract::In the breast carcinamas, sentinel lymph node biopsy (SLNB) attracts attention as technique to be settled by axillary lymph node metastasis, but existence of a false negative case is a problem. Equivalent cross relaxation rate image (ECRI) is the measurement method that we can evaluate a change of organization structu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00208-x

    authors: Matsushima S,Sasaki F,Sarumaru S,Ohta D,Era S,Sogami M,Inaba T,Kinosada Y

    更新日期:2003-11-01 00:00:00

  • A new method for diffusion weighted imaging.

    abstract::A new method for generating diffusion contrast in magnetic resonance imaging is presented. This technique is robust enough to allow implementation on conventional imaging systems without hardware modifications. Results from phantom measurements are reported. Qualitative contrast changes in magnetic resonance images de...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90069-p

    authors: Norwood TJ,Williams SC

    更新日期:1993-01-01 00:00:00

  • Three-dimensional adiabatic inversion recovery prepared ultrashort echo time cones (3D IR-UTE-Cones) imaging of cortical bone in the hip.

    abstract:PURPOSE:We present three-dimensional adiabatic inversion recovery prepared ultrashort echo time Cones (3D IR-UTE-Cones) imaging of cortical bone in the hip of healthy volunteers using a clinical 3T scanner. METHODS:A 3D IR-UTE-Cones sequence, based on a short pulse excitation followed by a 3D Cones trajectory, with a ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.07.012

    authors: Nazaran A,Carl M,Ma Y,Jerban S,Zhu Y,Lu X,Du J,Chang EY

    更新日期:2017-12-01 00:00:00

  • Spatial heterogeneity in the muscle functional MRI signal intensity time course: effect of exercise intensity.

    abstract::It has previously been observed that during isometric dorsiflexion exercise, the time course of T2-weighted signal intensity (SI) changes is spatially heterogeneous. The purpose of this study was to test the hypothesis that this spatial heterogeneity would increase at higher contraction intensities. Eight subjects per...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.01.023

    authors: Damon BM,Wadington MC,Lansdown DA,Hornberger JL

    更新日期:2008-10-01 00:00:00

  • An alternative viewpoint of the similarities and differences of SVD and FT deconvolution algorithms used for quantitative MR perfusion studies.

    abstract::Quantitative cerebral blood flow (CBF) values can be determined from residue function estimates obtained from magnetic resonance dynamic susceptibility contrast (DSC) perfusion studies using a variety of deconvolution approaches. However, there are significant differences between the CBF estimates obtained, difference...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.12.001

    authors: Salluzzi M,Frayne R,Smith MR

    更新日期:2005-04-01 00:00:00

  • Rapid acquisition strategy for functional T1ρ mapping of the brain.

    abstract::Functional T1ρ mapping has been proposed as a method to assess pH and metabolism dynamics in the brain with high spatial and temporal resolution. The purpose of this work is to describe and evaluate a variant of the spin-locked echo-planar imaging sequence for functional T1ρ mapping at 3T. The proposed sequence rapidl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.07.010

    authors: Johnson CP,Heo HY,Thedens DR,Wemmie JA,Magnotta VA

    更新日期:2014-11-01 00:00:00

  • Aligning 3D time-of-flight MRA datasets for quantitative longitudinal studies: evaluation of rigid registration techniques.

    abstract:OBJECTIVE:3D Time-of-flight (TOF) magnetic resonance angiography is commonly used for vascular analyses. A quantification of longitudinal morphological changes usually requires the registration of TOF image sequences acquired at different time points. The aim of this study was to evaluate the precision of different 3D ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.011

    authors: Verleger T,Schönfeld M,Säring D,Siemonsen S,Fiehler J,Forkert ND

    更新日期:2014-12-01 00:00:00

  • Fully automated contour detection of the ascending aorta in cardiac 2D phase-contrast MRI.

    abstract:PURPOSE:In this study we proposed a fully automated method for localizing and segmenting the ascending aortic lumen with phase-contrast magnetic resonance imaging (PC-MRI). MATERIAL AND METHODS:Twenty-five phase-contrast series were randomly selected out of a large population dataset of patients whose cardiac MRI exam...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.11.010

    authors: Codari M,Scarabello M,Secchi F,Sforza C,Baselli G,Sardanelli F

    更新日期:2018-04-01 00:00:00

  • Quantitation of non-Einstein diffusion behavior of water in biological tissues by proton MR diffusion imaging: synthetic image calculations.

    abstract::The non-Einstein diffusion behavior of water in a model biological tissue system, intact duck embryos, has been investigated by the use of an in vivo proton pulsed-gradient spin-echo (PGSE) MR imaging technique. Multiple-frame MR images of the intact duck embryos and control solution (0.5 mM CuSO4 doped water) were ac...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90476-t

    authors: Cheng KH

    更新日期:1993-01-01 00:00:00

  • Quantitation of normal canine hippocampus formation volume: correlation of MRI with gross histology.

    abstract::The hippocampal formation possesses an important role in the development and maintenance of short-term memory. In this study, magnetic resonance imaging (MRI) and gross histology were used to quantify the volume of the hippocampal formation in canines. High resolution MRI, using 1 mm thick slices and an intraplanar re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02083-6

    authors: Vullo T,Deo-Narine V,Stallmeyer MJ,Gomez DG,Cahill PT

    更新日期:1996-01-01 00:00:00

  • Finite element aided tracking of signal intensity changes in deforming intervertebral disc tissue.

    abstract::Tracking of signal intensity changes in soft tissue over time is often hampered by deformation of the tissue. In this study a method is described that uses finite element modeling to compensate for tissue deformation. The method is applied to the quantification of fluid redistribution in an intervertebral disc that de...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00251-8

    authors: Kingma I,Weinans H,van Dieën JH,de Boer RW

    更新日期:1998-01-01 00:00:00

  • N-acetylaspartate reductions measured by 1H MRSI in cognitively impaired HIV-seropositive individuals.

    abstract::We used magnetic resonance imaging (MRI) and water-suppressed proton MR spectroscopic imaging (1H MRSI) to study the effects of human immunodeficiency virus (HIV) infection on the brain. Our recent in vivo finding of lower N-acetylaspartate (NAA), a putative marker of neurons, in the supraventricular brain of cognitiv...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92460-0

    authors: Meyerhoff DJ,MacKay S,Poole N,Dillon WP,Weiner MW,Fein G

    更新日期:1994-01-01 00:00:00

  • Chemical exchange saturation transfer MR imaging of articular cartilage glycosaminoglycans at 3 T: Accuracy of B0 Field Inhomogeneity corrections with gradient echo method.

    abstract::Glycosaminoglycan Chemical Exchange Saturation Transfer (gagCEST) is an important molecular MRI methodology developed to assess changes in cartilage GAG concentrations. The correction for B0 field inhomogeneity is technically crucial in gagCEST imaging. This study evaluates the accuracy of the B0 estimation determined...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.009

    authors: Wei W,Jia G,Flanigan D,Zhou J,Knopp MV

    更新日期:2014-01-01 00:00:00

  • Severe anaphylactoid reaction after i.v. Gd-DTPA.

    abstract::Serious adverse reactions following the IV administration of Gd-DTPA (Magnevist, gadopenetate dimeglumine, Berlex Laboratories, Wayne, NJ), although extremely rare, can occur. As yet, there has been no published case of a severe anaphylactoid-type reaction to Gd-DTPA. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90019-x

    authors: Weiss KL

    更新日期:1990-01-01 00:00:00

  • Fat ViP MRI: Virtual Phantom Magnetic Resonance Imaging of water-fat systems.

    abstract:OBJECT:Virtual Phantom Magnetic Resonance Imaging (ViP MRI) is a method to generate reference signals on MR images, using external radiofrequency (RF) signals. The aim of this study was to assess the feasibility of ViP MRI to generate complex-data images of phantoms mimicking water-fat systems. MATERIALS AND METHODS:V...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.002

    authors: Salvati R,Hitti E,Bellanger JJ,Saint-Jalmes H,Gambarota G

    更新日期:2016-06-01 00:00:00

  • Reducing motion artifacts in two-dimensional Fourier transform imaging.

    abstract::The effects of motion in two-dimensional Fourier transform imaging (2DFT) are considered. Specific calculations describing the case of periodic motion are presented. The results predict the commonly seen artifact of image replication, sometimes referred to as ghosting. Expressions for both position and amplitude of th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(86)91046-5

    authors: Haacke EM,Patrick JL

    更新日期:1986-01-01 00:00:00

  • Perfusion MR imaging and proton MR spectroscopic imaging in differentiating necrotizing cerebritis from glioblastoma multiforme.

    abstract::We describe a lesion with the magnetic resonance imaging (MRI) characteristics of a glioblastoma mutiforme and demonstrate how perfusion MRI and proton MR spectroscopic imaging can be used to differentiate necrotizing cerebritis from what appeared to be a high-grade glioma. A 43-year-old woman presented to her physici...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.09.028

    authors: Pivawer G,Law M,Zagzag D

    更新日期:2007-02-01 00:00:00

  • STrategically Acquired Gradient Echo (STAGE) imaging, part II: Correcting for RF inhomogeneities in estimating T1 and proton density.

    abstract:PURPOSE:To develop a method for mapping the B1 transmit (B1t) and B1 receive (B1r) fields from two gradient echo datasets each with a different flip angle and from these two images obtain accurate T1 and proton density (PD) maps of the brain. METHODS:A strategically acquired gradient echo (STAGE) data set is collected...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.10.006

    authors: Wang Y,Chen Y,Wu D,Wang Y,Sethi SK,Yang G,Xie H,Xia S,Haacke EM

    更新日期:2018-02-01 00:00:00

  • 4D MR phase and magnitude segmentations with GPU parallel computing.

    abstract::The increasing size and number of data sets of large four dimensional (three spatial, one temporal) magnetic resonance (MR) cardiac images necessitates efficient segmentation algorithms. Analysis of phase-contrast MR images yields cardiac flow information which can be manipulated to produce accurate segmentations of t...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.019

    authors: Bergen RV,Lin HY,Alexander ME,Bidinosti CP

    更新日期:2015-01-01 00:00:00

  • Effect of slice orientation on reproducibility of fMRI motor activation at 3 Tesla.

    abstract::The effect of slice orientation on reproducibility and sensitivity of 3T fMRI activation using a motor task has been investigated in six normal volunteers. Four slice orientations were used; axial, oblique axial, coronal and sagittal. We applied analysis of variance (ANOVA) to suprathreshold voxel statistics to quanti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00399-x

    authors: Gustard S,Fadili J,Williams EJ,Hall LD,Carpenter TA,Brett M,Bullmore ET

    更新日期:2001-12-01 00:00:00

  • Accuracy and reproducibility of automated white matter hyperintensities segmentation with lesion segmentation tool: A European multi-site 3T study.

    abstract::Brain vascular damage accumulate in aging and often manifest as white matter hyperintensities (WMHs) on MRI. Despite increased interest in automated methods to segment WMHs, a gold standard has not been achieved and their longitudinal reproducibility has been poorly investigated. The aim of present work is to evaluate...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.11.008

    authors: Ribaldi F,Altomare D,Jovicich J,Ferrari C,Picco A,Pizzini FB,Soricelli A,Mega A,Ferretti A,Drevelegas A,Bosch B,Müller BW,Marra C,Cavaliere C,Bartrés-Faz D,Nobili F,Alessandrini F,Barkhof F,Gros-Dagnac H,Ranjeva JP

    更新日期:2021-02-01 00:00:00