Abstract:
:Signal-to-noise ratio (SNR) is a critical factor in MR-guided high-intensity focused ultrasound (HIFU) for local heating, which can affect the accuracy of temperature measurement. In order to achieve high SNR and higher temporal resolution, dedicated coil arrays for MR-guided HIFU applications need to be developed. In this work, a flexible 9-channel coil array was designed, and constructed at 3 T to achieve fast temperature mapping for MR-guided HIFU applications on rabbit leg muscle. Coil performance was evaluated for SNR, and parallel imaging capability by in-vivo studies. Compared to a commercially available 4-channel flexible coil array, the dedicated 9-channel coil array has a much higher SNR, with at least a 2.6-fold increment in the region of interest (ROI). The inverse g-factors maps demonstrated that the dedicated 9-channel coil array has a better parallel imaging capability than the Flex Small 4. With accelerations normal to the array direction, both coil arrays showed much higher g-factors than those of accelerations along the array direction. Room temperature mapping was implemented to evaluate the temperature measurement accuracy by in-vivo experiments. The precisions of the 9-channel coil, ±0.18 °C for un-acceleration and ± 0.56 °C for acceleration at R = 2 × 2, both improved by an order of magnitude than these of the 4-channel coil, which were ± 1.45 °C for un-acceleration and ± 3.52 °C for acceleration at R = 2 × 2. In the fast temperature imaging on the rabbit leg muscle with heating, a high temporal resolution of 3.3 s with a temperature measurement precision of ±0.56 °C has been achieved using the dedicated 9-channel coil. This study demonstrates that the dedicated 9-channel coil array for rabbit leg imaging provides improved performance in SNR, parallel imaging capability, and the accuracy of temperature measurement compared to a commercial 4-channel coil, and it also achieves fast temperature mapping in practical MR-guided HIFU applications.
journal_name
Magn Reson Imagingjournal_title
Magnetic resonance imagingauthors
Chen Q,Li Y,Jiang R,Zou C,Tie C,Wen J,Yang X,Zhang X,Liu X,Zheng Hdoi
10.1016/j.mri.2019.10.008subject
Has Abstractpub_date
2020-01-01 00:00:00pages
37-44eissn
0730-725Xissn
1873-5894pii
S0730-725X(19)30386-8journal_volume
65pub_type
杂志文章abstract::The present trend in dynamic contrast-enhanced MRI is to increase the number of estimated perfusion parameters using complex pharmacokinetic models. However, less attention is given to the precision analysis of the parameter estimates. In this paper, the distributed capillary adiabatic tissue homogeneity pharmacokinet...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.02.003
更新日期:2014-06-01 00:00:00
abstract::The functional value of TurboFLASH MR imaging in the assessment of dynamic contrast enhancement and renal perfusion anomalies was evaluated in seven patients, who also underwent renal scintigraphy in baseline conditions. The basal renograms obtained from MAG-3 scintigraphy (mercapto acetyl triglycine, MAG3-S) and from...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)92534-8
更新日期:1994-01-01 00:00:00
abstract::The discrimination of tumor boundaries from normal tissue, as well as the evaluation of tissue heterogeneity and tumor grading often continue to pose a challenge in MRI. Although yielding promising results in various fields of medical imaging, two- dimensional (2D) texture analysis in MRI has, until now, demonstrated ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(03)00201-7
更新日期:2003-11-01 00:00:00
abstract::We examined if MR diffusion tensor imaging with fiber tracking could be performed on the sciatic nerve. In 3 healthy volunteers the proximal thigh was examined on a 1.5-Tesla MR-scanner with a 2-channel phased-array coil. Though inherently susceptible to motion, field inhomogeneities, and fast T(2)-relaxation of the d...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2004.01.073
更新日期:2004-06-01 00:00:00
abstract::Perceptions of sensation and pain in healthy people are believed to be the net result of sensory input and descending modulation from brainstem and cortical regions depending on emotional and cognitive factors. Here, the influence of attention on neural activity in the spinal cord during thermal sensory stimulation of...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2010.07.012
更新日期:2011-01-01 00:00:00
abstract::Thoracic and abdominal magnetic resonance imaging studies generally require some type of compensation for respiratory and cardiac motions in order to yield artifact-free images with good signal-to-noise ratio. Most techniques for respiratory compensation require the use of a non-NMR sensing device to monitor the subje...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(01)00403-9
更新日期:2001-07-01 00:00:00
abstract::Quantitative longitudinal brain magnetic resonance (MR) studies may be confounded by scanner-related drifts in voxel sizes. Total intracranial volume (TIV) normalisation is commonly used to correct serial cerebral volumetric measurements for these drifts. We hypothesised that automated rigid-body registration of whole...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2004.01.057
更新日期:2004-09-01 00:00:00
abstract::Fifty-four independent scans were performed in two volunteers covering one anatomic region in each (the brain and knee) with the purpose of ascertaining the agreement between predicted and measured signal-to-noise ratios (SNR). Systematically varied parameters were number of excitations (NEX), field of view (FOV), sec...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(90)90009-q
更新日期:1990-01-01 00:00:00
abstract::Systems investigated with NMR spectroscopy are sometimes heterogeneous with respect to chemical composition, rates of chemical exchange, and other properties influencing magnetic resonance parameters. A method was developed to spatially encode reaction kinetic information and produce NMR images sensitive to chemical e...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(88)90125-7
更新日期:1988-09-01 00:00:00
abstract:PURPOSE:To evaluate the application of high-resolution MRI methodology for characterizing the fluid velocity field and evaluate fluid shear field within a simplified in vitro model of a bone-implant interface. MATERIALS AND METHODS:The study used a specific micromotion canine bone implant that has been used for over a...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2005.11.001
更新日期:2006-06-01 00:00:00
abstract::Functional magnetic resonance imaging (fMRI) was performed on a conventional 1.5 T scanner by means of a modified FLASH-technique at temporal resolutions of 80 and 320 ms. The method's stability was assessed by phantom measurements and by investigation of three volunteers resulting in a low amplitude (3%) periodic (4 ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(96)00021-5
更新日期:1996-01-01 00:00:00
abstract::Glioblastoma Multiforme is the most common and most aggressive type of brain tumors. Although accurate prediction of Glioblastoma borders and shape is absolutely essential for neurosurgeons, there are not many in silico platforms that can make such predictions. In the current study, an automatic patient-specific simul...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.12.012
更新日期:2020-05-01 00:00:00
abstract::Noise estimation is a challenging task in magnetic resonance imaging (MRI), with applications in quality assessment, filtering or diffusion tensor estimation. Main noise estimators based on the Rician model are revisited and classified in this article, and new useful methods are proposed. Additionally, all the surveye...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2009.05.025
更新日期:2009-12-01 00:00:00
abstract::In vivo proton and phosphorus magnetic resonance spectroscopy (MRS) studies were performed at 1.5 T on two patients (siblings) diagnosed as having a mitochondrial cytopathy. The clinical diagnosis was based on a complete battery of biochemical tests, electron microscopy and modified Gomori trichrome stain studies of m...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(89)90695-4
更新日期:1989-03-01 00:00:00
abstract:PURPOSE:The state-of-the-art method to quantify sodium concentrations in vivo consists in a fully relaxed 3D spin-density (SD) weighted acquisition. Nevertheless, most sodium MRI clinical studies use short-TR SD acquisitions to reduce acquisition durations. We present a clinically viable implementation of the Variable ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.01.015
更新日期:2019-05-01 00:00:00
abstract::An NMR technique is described which allows the observation of ionic charge carriers moving in the electric field within a porous system saturated with electrolyte solution. This method, which was recently developed in our laboratory, gives experimental access to the study of electric transport in disordered media on a...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(01)00267-3
更新日期:2001-04-01 00:00:00
abstract::The objective of this study was to determine the value of magnetic resonance (MR) imaging in diagnosing local recurrence of Ewing sarcoma. We retrospectively reviewed radiographs, Tc99m-methylene diphosphonate (MDP) skeletal scintigraphy, computed tomography scans, and MR studies of 11 patients who had local recurrenc...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)90079-7
更新日期:1994-01-01 00:00:00
abstract::In this work, magnetic resonance imaging (MRI) was employed to observe the in-situ formation and dissociation of methane hydrates in porous media. Methane hydrate was formed in a high-pressure cell with controlled temperature, and then the hydrate was dissociated by thermal injection. The process was photographed by t...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.12.010
更新日期:2015-05-01 00:00:00
abstract::L-2-Chloropropionic acid (L-CPA) is selectively toxic to rat cerebellar granule cells; necrosis is first observed about 36 hours after administration of L-CPA (750 mg/kg p.o.) becoming more marked by 48 h. Parallel to the onset of cell death an increase in cerebellar water content and sodium concentration has been rep...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(01)00231-4
更新日期:2001-02-01 00:00:00
abstract:BACKGROUND:Since the advent of magnetic resonance imaging, metal artifacts have posed an important diagnostic problem in different fields of medicine. However, this has not been systematically studied in patients undergoing surgery for brain tumors. OBJECTIVE:This study was planned to assess whether metal artifacts ca...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.11.001
更新日期:2013-06-01 00:00:00
abstract::Proton MR measurements were performed in lyophilized urine samples collected from 5 normals (N) and 5 idiopathic hypercalciuric recurrent stone formers (SF). T1 and T2 relaxation times were measured with a Bruker PC Multispec at 20 MHz and 37 degrees C in the lyophilized samples and in samples gradually rehydrated. Si...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(88)90522-x
更新日期:1988-01-01 00:00:00
abstract::Geometric distortion in MR imaging predominantly arises from the inhomogeneity of the static field and the nonlinearity of the gradients. It is the purpose of this paper to analyse the object and machine related contributions to geometric distortion in order to determine which corrections are necessary for attaining a...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(92)90011-n
更新日期:1992-01-01 00:00:00
abstract::Functional magnetic resonance imaging (fMRI) research has shown that brain arteriovenous malformations (AVMs) lead to reorganization of cortical motor areas. Since it is known that blood oxygenation level-dependent signal in fMRI may be influenced by the hemodynamic perturbation associated with the presence of the AVM...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2009.05.029
更新日期:2009-12-01 00:00:00
abstract::Susceptibility differences are common causes for artifacts in magnetic resonance (MR); therefore, it is important to choose phantom materials in a way that these artifacts are kept at a minimum. In this study, a previously proposed MR imaging (MRI) method [Beuf O, Briguet A, Lissac M, Davis R. Magnetic resonance imagi...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2006.07.005
更新日期:2006-11-01 00:00:00
abstract::MRI is applied to the visualisation of wetting heterogeneities evidenced by water proton T1 contrast at 0.1 T. Water saturated Fontainebleau sandstone samples were examined either in their original water-wet condition, or after silanation. T1, T2Hahn, and T2CPMG were measured for several porosities. T1 and T2CPMG of h...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)91557-1
更新日期:1994-01-01 00:00:00
abstract::The clinical evaluation of three-dimensional time-of-flight MR angiography was prospectively performed in 16 patients with intracranial meningioma. MR angiographic techniques used in this study both with and without gadopentetate dimeglumine made it possible to demonstrate the topographic relationship between the tumo...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(93)90466-q
更新日期:1993-01-01 00:00:00
abstract::Within the magnetic resonance imaging (MRI) community the trend is going to higher and higher magnetic fields, ranging from 1.5 T to 7 T, corresponding to Larmor frequencies of 63.8-298 MHz. Since for high-field MRI the magnetization increases with the applied magnetic field, the signal-to-noise-ratio increases as wel...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.06.014
更新日期:2013-02-01 00:00:00
abstract::Dynamic contrast-enhanced magnetic resonance imaging (MRI) is widely used for measuring perfusion and blood volume, especially cerebral blood volume (CBV). In case of blood-brain barrier (BBB) disruption, the conventional techniques only partially determine the pharmacokinetic parameters of contrast medium (CM) exchan...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(00)00223-x
更新日期:2000-12-01 00:00:00
abstract::Magnetic resonance elastography (MRE) uses a phase-contrast MRI technique to image shear wave propagation in tissue followed by the mathematical inversion of the equations of motion governing tissue mechanics to noninvasively image tissue stiffness. This work investigates the impact of various MR sampling strategies d...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2010.06.016
更新日期:2010-12-01 00:00:00
abstract::A magnetic resonance imaging cardiac magnetic susceptometry (MRI-CS) technique for assessing cardiac tissue iron concentration based on phase mapping was developed. Normal control subjects (n=9) and thalassemia patients (n=13) receiving long-term blood transfusion therapy underwent MRI-CS and MRI measurements of the c...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2009.12.001
更新日期:2010-04-01 00:00:00