Cardiac magnetic resonance tissue tracking in right ventricle: Feasibility and normal values.

Abstract:

PURPOSE:To investigate right ventricular (RV) strain in patients without identified cardiac pathology using cardiac magnetic resonance tissue tracking (CMR TT). METHODS:A total of 50 consecutive patients with no identified cardiac pathology were analyzed. RV longitudinal and circumferential strain was assessed by CMR TT. The age range was 4-81years with a median of 32years (interquartile range, 15 to 56years). RESULTS:Analysis time per patient was <5min. The peak longitudinal strain (Ell) was -22.11±3.51%. The peak circumferential strains (Ecc) for global, basal, mid-cavity and apical segments were as follows: -11.69±2.25%, -11.00±2.45%, -11.17±3.36%, -12.90±3.34%. There were significant gender differences in peak Ecc at the base (P=0.04) and the mid-cavity (P=0.03) with greater deformation in females than in males. On Bland-Altman analysis, peak Ell (mean bias, 0.22±1.67; 95% CI -3.05 to 3.49) and mid-cavity Ecc (mean bias, 0.036±1.75; 95% CI, -3.39 to 3.47) had the best intra-observer agreement and inter-observer agreement, respectively. CONCLUSIONS:RV longitudinal and circumferential strains can be quickly assessed with good intra-observer and inter-observer variability using TT.

journal_name

Magn Reson Imaging

authors

Truong VT,Safdar KS,Kalra DK,Gao X,Ambach S,Taylor MD,Moore R,Taylor RJ,Germann J,Toro-Salazar O,Jefferies JL,Bartone C,Raman SV,Ngo T,Mazur W

doi

10.1016/j.mri.2017.01.007

subject

Has Abstract

pub_date

2017-05-01 00:00:00

pages

189-195

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(17)30007-3

journal_volume

38

pub_type

杂志文章
  • Functional MR imaging of visual and motor cortex stimulation at high temporal resolution using a FLASH technique on a standard 1.5 Tesla scanner.

    abstract::Functional magnetic resonance imaging (fMRI) was performed on a conventional 1.5 T scanner by means of a modified FLASH-technique at temporal resolutions of 80 and 320 ms. The method's stability was assessed by phantom measurements and by investigation of three volunteers resulting in a low amplitude (3%) periodic (4 ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(96)00021-5

    authors: Wiener E,Schad LR,Baudendistel KT,Essig M,Müller E,Lorenz WJ

    更新日期:1996-01-01 00:00:00

  • Computer-assisted design of surface coils used in magnetic resonance imaging. I. The calculation of the magnetic field.

    abstract::For a number of reasons, it is desirable to fabricate coils which, for a known current, shall produce predetermined values of the magnetic field intensity at a number of points within a nuclear magnetic resonance imager. The calculation of the magnetic field intensity at a set of points involves the integration of the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90524-9

    authors: Letcher JH

    更新日期:1989-11-01 00:00:00

  • Magnetic resonance in the era of molecular imaging of cancer.

    abstract::Magnetic resonance imaging (MRI) has played an important role in the diagnosis and management of cancer since it was first developed, but other modalities also continue to advance and provide complementary information on the status of tumors. In the future, there will be a major continuing role for noninvasive imaging...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2011.02.003

    authors: Gore JC,Manning HC,Quarles CC,Waddell KW,Yankeelov TE

    更新日期:2011-06-01 00:00:00

  • Multicontrast multiecho FLASH MRI for targeting the subthalamic nucleus.

    abstract::The subthalamic nucleus (STN) is one of the most common stimulation targets for treating Parkinson's disease using deep brain stimulation (DBS). This procedure requires precise placement of the stimulating electrode. Common practice of DBS implantation utilizes microelectrode recording to locate the sites with the cor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.02.006

    authors: Xiao Y,Beriault S,Pike GB,Collins DL

    更新日期:2012-06-01 00:00:00

  • Relationship between neural and hemodynamic signals during spontaneous activity studied with temporal kernel CCA.

    abstract::Functional magnetic resonance imaging (fMRI) based on the so-called blood oxygen level-dependent (BOLD) contrast is a powerful tool for studying brain function not only locally but also on the large scale. Most studies assume a simple relationship between neural and BOLD activity, in spite of the fact that it is impor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.12.016

    authors: Murayama Y,Biessmann F,Meinecke FC,Müller KR,Augath M,Oeltermann A,Logothetis NK

    更新日期:2010-10-01 00:00:00

  • Multispectral analysis of bone lesions in the hands of patients with rheumatoid arthritis.

    abstract::Quantitative measures of rheumatoid arthritis (RA) disease progression can provide valuable tools for evaluation of new treatments during clinical trials. In this study, a novel multispectral (MS) MRI analysis method is presented to quantify changes in bone lesion volume (DeltaBLV) in the hands of RA patients. Image r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.013

    authors: Carano RA,Lynch JA,Redei J,Ostrowitzki S,Miaux Y,Zaim S,White DL,Peterfy CG,Genant HK

    更新日期:2004-05-01 00:00:00

  • Correction of partial volume inaccuracies in quantitative phase contrast MR angiography.

    abstract::The phase difference method of phase contrast MR angiography provides a means of measuring the average velocity in each voxel of an MR scan. When static tissue is present in a voxel containing flow, the measured velocity is not the average velocity of the flow alone, but is lower due to the partial volume effect of th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91245-r

    authors: Hamilton CA

    更新日期:1994-01-01 00:00:00

  • NMR study of the diffusion processes in gels.

    abstract::Stimulated spin-echo and Carr-Purcell pulse sequences, with pulsed magnetic field gradients, have been used to study the self-diffusion processes of the water in swollen and in supercoiled polyacrylamide gels and in polysaccharides agarose gels, for different polymer concentrations. Restricted diffusion effects are ev...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00202-0

    authors: Pavesi L,Balzarini M

    更新日期:1996-01-01 00:00:00

  • Evaluation of intracranial stenoses and aneurysms with accelerated 4D flow.

    abstract::The aim of this study was to evaluate intracranial arterial stenoses and aneurysms with accelerated time-resolved three-dimensional (3D) phase-contrast MRI or 4D flow. The 4D flow technique was utilized to image four normal volunteers, two patients with intracranial stenoses and two patients with intracranial aneurysm...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.042

    authors: Hope TA,Hope MD,Purcell DD,von Morze C,Vigneron DB,Alley MT,Dillon WP

    更新日期:2010-01-01 00:00:00

  • Measurement of fat fraction in the human thymus by localized NMR and three-point Dixon MRI techniques.

    abstract:PURPOSE:To develop a protocol to non-invasively measure and map fat fraction, fat/(fat+water), as a function of age in the adult thymus for future studies monitoring the effects of interventions aimed at promoting thymic rejuvenation and preservation of immunity in older adults. MATERIALS AND METHODS:Three-dimensional...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.03.016

    authors: Fishbein KW,Makrogiannis SK,Lukas VA,Okine M,Ramachandran R,Ferrucci L,Egan JM,Chia CW,Spencer RG

    更新日期:2018-07-01 00:00:00

  • High-resolution MR venography of cerebral arteriovenous malformations.

    abstract::The purpose of this study was to evaluate the diagnostic potential of a high-resolution magnetic resonance (MR) venography technique in patients with cerebral arteriovenous malformations (AVMs). A high-resolution 3D gradient echo sequence was used with a long echo time TE to obtain venous information down to sub-pixel...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00084-3

    authors: Essig M,Reichenbach JR,Schad LR,Schoenberg SO,Debus J,Kaiser WA

    更新日期:1999-12-01 00:00:00

  • Diffusion MRI with Semi-Automated Segmentation Can Serve as a Restricted Predictive Biomarker of the Therapeutic Response of Liver Metastasis.

    abstract:PURPOSE:To assess the value of semi-automated segmentation applied to diffusion MRI for predicting the therapeutic response of liver metastasis. METHODS:Conventional diffusion weighted magnetic resonance imaging (MRI) was performed using b-values of 0, 150, 300 and 450s/mm(2) at baseline and days 4, 11 and 39 followin...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.08.006

    authors: Stephen RM,Jha AK,Roe DJ,Trouard TP,Galons JP,Kupinski MA,Frey G,Cui H,Squire S,Pagel MD,Rodriguez JJ,Gillies RJ,Stopeck AT

    更新日期:2015-12-01 00:00:00

  • Parametric multiecho proton spectroscopic imaging: application to the rat brain in vivo.

    abstract::A parametric multiecho variant of proton spectroscopic imaging (SI) is presented using a multiecho SI sequence with uniform phase-encoding of all echoes within each echo train. The acquisition of SI data sets at different echo times (TE) increases the amount of information obtained within the same total measuring time...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00027-e

    authors: Dreher W,Leibfritz D

    更新日期:1995-01-01 00:00:00

  • On the R2⁎ relaxometry in complex multi-peak multi-Echo chemical shift-based water-fat quantification: Applications to the neuromuscular diseases.

    abstract:PURPOSE:Investigation of the feasibility of the R2⁎ mapping techniques by using latest theoretical models corrected for confounding factors and optimized for signal to noise ratio. THEORY AND METHODS:The improvement of the performance of state of the art magnetic resonance imaging (MRI) relaxometry algorithms is chall...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.08.006

    authors: Siracusano G,La Corte A,Milazzo C,Anastasi GP,Finocchio G,Gaeta M

    更新日期:2017-01-01 00:00:00

  • PERFIDI: parametrically enabled relaxation filters with double and multiple inversion.

    abstract::We present a novel approach to the nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) analysis of complex samples with nontrivial distribution of longitudinal relaxation rate R(1). Parametrically enabled relaxation filters with double and multiple inversion (PERFIDI) aim to separate signals arising ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.12.001

    authors: Sykora S,Bortollotti V,Fantazzini P

    更新日期:2007-05-01 00:00:00

  • Complimentary aspects of diffusion imaging and fMRI: II. Elucidating contributions to the fMRI signal with diffusion sensitization.

    abstract::Tissue water molecules reside in different biophysical compartments. For example, water molecules in the vasculature reside for variable periods of time within arteries, arterioles, capillaries, venuoles and veins, and may be within blood cells or blood plasma. Water molecules outside of the vasculature, in the extrav...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2007.02.006

    authors: Mulkern RV,Haker SJ,Maier SE

    更新日期:2007-07-01 00:00:00

  • Comparison between end-tidal CO₂ and respiration volume per time for detecting BOLD signal fluctuations during paced hyperventilation.

    abstract::Respiratory motion and capnometry monitoring were performed during blood oxygen level-dependent (BOLD) functional magnetic resonance imaging (fMRI) of the brain while a series of paced hyperventilation tasks were performed that caused significant hypocapnia. Respiration volume per time (RVT) and end-tidal carbon dioxi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.07.011

    authors: Vogt KM,Ibinson JW,Schmalbrock P,Small RH

    更新日期:2011-11-01 00:00:00

  • Structural changes in glutamate cell swelling followed by multiparametric q-space diffusion MR of excised rat spinal cord.

    abstract::Diffusion in the extracellular and intracellular spaces (ECS and ICS, respectively) was evaluated in excised spinal cords, before and after cell swelling induced by glutamate, by high b-value q-space diffusion MR of specific markers and water. The signal decays of deuterated tetramethylammonium (TMA-d(12)) chloride, a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.029

    authors: Biton IE,Mayk A,Assaf Y,Cohen Y

    更新日期:2004-06-01 00:00:00

  • Quantitative diffusion MRI using reduced field-of-view and multi-shot acquisition techniques: Validation in phantoms and prostate imaging.

    abstract:PURPOSE:To evaluate the reproducibility of quantitative diffusion measurements obtained with reduced Field of View (rFOV) and Multi-shot EPI (msEPI) acquisitions, using single-shot EPI (ssEPI) as a reference. METHODS:Diffusion phantom experiments, and prostate diffusion-weighted imaging in healthy volunteers and patie...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.04.006

    authors: Zhang Y,Holmes J,Rabanillo I,Guidon A,Wells S,Hernando D

    更新日期:2018-09-01 00:00:00

  • Diffusion-weighted imaging in epilepsy.

    abstract::Diffusion-weighted imaging (DWI) is a relatively new magnetic resonance imaging (MRI) technique that can be used to probe the microenvironment of water. Contrast in DWI depends on properties different from traditional T1 and T2 contrast, and is derived form the translational motion of water molecules. Since it is reas...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(95)02036-s

    authors: Helpern JA,Huang N

    更新日期:1995-01-01 00:00:00

  • Diffusion pore imaging with generalized temporal gradient profiles.

    abstract::In porous material research, one main interest of nuclear magnetic resonance diffusion (NMR) experiments is the determination of the shape of pores. While it has been a longstanding question if this is in principle achievable, it has been shown recently that it is indeed possible to perform NMR-based diffusion pore im...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.03.027

    authors: Laun FB,Kuder TA

    更新日期:2013-09-01 00:00:00

  • Tsallis-Entropy Segmentation through MRF and Alzheimer anatomic reference for Brain Magnetic Resonance Parcellation.

    abstract::Quantifying the intracranial tissue volume changes in magnetic resonance imaging (MRI) assists specialists to analyze the effects of natural or pathological changes. Since these changes can be subtle, the accuracy of the automatic compartmentalization method is always criticized by specialists. We propose and then eva...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.11.002

    authors: Azimbagirad M,Simozo FH,Senra Filho ACS,Murta Junior LO

    更新日期:2020-01-01 00:00:00

  • "MR conditional" respiratory ventilator system incident in a 3-T MRI environment.

    abstract::The misunderstanding of the labeling for an "MR conditional" respiratory ventilator system resulted in the placement of this device, which had substantial ferromagnetic components, too close to a 3-T magnetic resonance (MR) system, causing a projectile incident. Magnetic resonance imaging health care professionals sho...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.07.002

    authors: Greenberg KL,Weinreb J,Shellock FG

    更新日期:2011-10-01 00:00:00

  • Electric stimulation fMRI of the perforant pathway to the rat hippocampus.

    abstract::The hippocampal formation is a brain system that is implicated in learning and memory. The major input to the hippocampus arrives from the entorhinal cortex (EC) to the dentate gyrus (DG) through the perforant path. In the present work, we have investigated the functional properties of this connection by concomitantly...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.02.018

    authors: Canals S,Beyerlein M,Murayama Y,Logothetis NK

    更新日期:2008-09-01 00:00:00

  • Segmented diffusion-weighted imaging of the prostate: Application to transperineal in-bore 3T MR image-guided targeted biopsy.

    abstract:OBJECTIVE:This study aims to evaluate the applicability of using single-shot and multi-shot segmented diffusion-weighted imaging (DWI) techniques to support biopsy target localization in a cohort of targeted MRI-guided prostate biopsy patients. MATERIALS AND METHODS:Single-shot echo-planar diffusion-weighted imaging (...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.05.012

    authors: Fedorov A,Tuncali K,Panych LP,Fairhurst J,Hassanzadeh E,Seethamraju RT,Tempany CM,Maier SE

    更新日期:2016-10-01 00:00:00

  • In vivo magnetic resonance study of the histochemistry of coconut (Cocos nucifera).

    abstract::Magnetic resonance imaging (MRI) and localized proton MR spectroscopy (MRS) techniques have been applied for studying different maturation processes in the histochemistry of coconut (Cocos nucifera). Images of the tender and mature coconut are characterized by protons of the aqueous solution present in the cavity and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00033-d

    authors: Jagannathan NR,Govindaraju V,Raghunathan P

    更新日期:1995-01-01 00:00:00

  • Factors affecting nitroxide reduction in ascorbate solution and tissue homogenates.

    abstract::Because of their paramagnetic properties, nitroxides are potentially useful as contrast agents in magnetic resonance imaging (MRI). They are reduced in vivo to their corresponding hydroxylamines which are nonparamagnetic and have no contrast enhancing property. Nitroxides with high resistance to reduction would be adv...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90012-8

    authors: Couet WR,Brasch RC,Sosnovsky G,Tozer TN

    更新日期:1985-01-01 00:00:00

  • Phase contrast and time-of-flight magnetic resonance angiography of the intracerebral arteries at 1.5, 3 and 7 T.

    abstract:PURPOSE:Time-of-flight (ToF) and phase contrast (PC) magnetic resonance angiographies (MRAs) are noninvasive applications to depict the cerebral arteries. Both approaches can image the cerebral vasculature without the administration of intravenous contrast. Therefore, it is used in routine clinical evaluation of cerebr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.10.023

    authors: Stamm AC,Wright CL,Knopp MV,Schmalbrock P,Heverhagen JT

    更新日期:2013-05-01 00:00:00

  • Fast multi-contrast MRI reconstruction.

    abstract::Multi-contrast magnetic resonance imaging (MRI) is a useful technique to aid clinical diagnosis. This paper proposes an efficient algorithm to jointly reconstruct multiple T1/T2-weighted images of the same anatomical cross section from partially sampled k-space data. The joint reconstruction problem is formulated as m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.025

    authors: Huang J,Chen C,Axel L

    更新日期:2014-12-01 00:00:00

  • The use of power images to perform quantitative analysis on low SNR MR images.

    abstract::Zero-mean noise introduced into quadrature detected MRI signals is generally rectified by the reconstruction algorithm to give a nonzero background intensity in the displayed image. In low signal-to-noise ratio (SNR) images, this background will inflate region of interest (ROI) signal measurements, leading to improper...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90225-3

    authors: Miller AJ,Joseph PM

    更新日期:1993-01-01 00:00:00