Quantifications of in vivo labeled stem cells based on measurements of magnetic moments.

Abstract:

:Cells labeled by super paramagnetic iron-oxide (SPIO) nanoparticles are more easily seen in gradient echo MR images, but it has not been shown that the amount of nanoparticles or the number of cells can be directly quantified from MR images. This work utilizes a previously developed and improved Complex Image Summation around a Spherical or Cylindrical Object (CISSCO) method to quantify the magnetic moments of several clusters of SPIO nanoparticle labeled cells from archived rat brain images. With the knowledge of mass magnetization of the cell labeling agent and cell iron uptake, the number of cells in each nanoparticle cluster can be determined. Using a high pass filter with a reasonable size has little effect on each measured magnetic moment from the CISSCO method. These procedures and quantitative results may help improve the efficacy of cell-based treatments in vivo.

journal_name

Magn Reson Imaging

authors

Kokeny P,Cheng YN,Liu S,Xie H,Jiang Q

doi

10.1016/j.mri.2016.08.003

subject

Has Abstract

pub_date

2017-01-01 00:00:00

pages

141-147

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(16)30108-4

journal_volume

35

pub_type

杂志文章
  • Dynamic contrast-enhanced MRI to assess hepatocellular carcinoma response to Transarterial chemoembolization using LI-RADS criteria: A pilot study.

    abstract:PURPOSE:To identify quantitative dynamic contrast-enhanced (DCE)-MRI perfusion parameters indicating tumor response of hepatocellular carcinoma (HCC) to transarterial chemoembolization (TACE). MATERIALS AND METHODS:This prospective pilot study was approved by our institutional review board; written and informed consen...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.mri.2019.06.017

    authors: Thibodeau-Antonacci A,Petitclerc L,Gilbert G,Bilodeau L,Olivié D,Cerny M,Castel H,Turcotte S,Huet C,Perreault P,Soulez G,Chagnon M,Kadoury S,Tang A

    更新日期:2019-10-01 00:00:00

  • Isotropically weighted intravoxel incoherent motion brain imaging at 7T.

    abstract::Perfusion magnetic resonance imaging (MRI) is a promising non-invasive technique providing insights regarding the brain's microvascular architecture in vivo. The scalar perfusion metrics can be used for quantitative diagnostics of various brain abnormalities, in particular, in the stroke cases and tumours. However, co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.11.007

    authors: Maximov II,Vellmer S

    更新日期:2019-04-01 00:00:00

  • Perfusion MR imaging and proton MR spectroscopic imaging in differentiating necrotizing cerebritis from glioblastoma multiforme.

    abstract::We describe a lesion with the magnetic resonance imaging (MRI) characteristics of a glioblastoma mutiforme and demonstrate how perfusion MRI and proton MR spectroscopic imaging can be used to differentiate necrotizing cerebritis from what appeared to be a high-grade glioma. A 43-year-old woman presented to her physici...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.09.028

    authors: Pivawer G,Law M,Zagzag D

    更新日期:2007-02-01 00:00:00

  • A simple method for MR elastography: a gradient-echo type multi-echo sequence.

    abstract::To demonstrate the feasibility of a novel MR elastography (MRE) technique based on a conventional gradient-echo type multi-echo MR sequence which does not need additional bipolar magnetic field gradients (motion encoding gradient: MEG), yet is sensitive to vibration. In a gradient-echo type multi-echo MR sequence, sev...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.10.002

    authors: Numano T,Mizuhara K,Hata J,Washio T,Homma K

    更新日期:2015-01-01 00:00:00

  • Quality assessment of localization technique performance in small volume in vivo 1H MR spectroscopy.

    abstract::A new phantom and evaluation method for experimental evaluation of 1H-magnetic resonance spectroscopy single volume localization techniques regarding signal contamination (C), defined as the part of the signal originating outside the volume of interest, is presented. The quality assessment method is based on a spheric...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00076-4

    authors: Burtscher IM,Johansson E,Holtås S,Ståhlberg F

    更新日期:1999-12-01 00:00:00

  • Velocity distribution of slow fluid flows in Bentheimer sandstone: an NMRI and propagator study.

    abstract::This work addresses the special problems of measuring flow velocity distributions in rock by NMR methods. Specifically, these problems are to measure very slow flows as well as flows in the presence of background magnetic field gradients caused by heterogeneities of the rock. We modify a stimulated echo sequence for u...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00110-5

    authors: Waggoner RA,Fukushima E

    更新日期:1996-01-01 00:00:00

  • Parallel imaging for first-pass myocardial perfusion.

    abstract::Two parallel imaging methods used for first-pass myocardial perfusion imaging were compared in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image artifacts. One used adaptive Time-adaptive SENSitivity Encoding (TSENSE) and the other used GeneRalized Autocalibrating Partially Parallel Acquisi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.10.012

    authors: Irwan R,Lubbers DD,van der Vleuten PA,Kappert P,Götte MJ,Sijens PE

    更新日期:2007-06-01 00:00:00

  • NMR-based analysis of shear strength of weakly expansive clay in sodium chloride solution.

    abstract::A series of direct shear and nuclear magnetic resonance (NMR) tests were performed on a compacted weakly expansive clay saturated by sodium chloride (NaCl) solutions with different concentrations to study the effect of NaCl solution on the shear strength and its mechanism. Results from the direct shear tests show that...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.01.002

    authors: Yu H,Sun D,Tian H

    更新日期:2019-05-01 00:00:00

  • Highly homogeneous circularly polarized RF field for whole body NMR imaging.

    abstract::Conditions for generation of polarized RF fields in cylindrical symmetry by high order coils are presented. Whole body NMR transmitters utilizing this principle would require a current control on a certain number of loops. In the present design this is obtained by feeding each loop by an appropriate linear combination...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90398-0

    authors: Sotgiu A,Gualtieri G,Passariello R

    更新日期:1988-05-01 00:00:00

  • Sampling time effects on signal-to-noise and contrast-to-noise ratios in spin-echo MRI.

    abstract::This work discusses the effect of sampling time on noise, signal-to-noise and contrast-to-noise ratios in magnetic resonance imaging. A simple imaging experiment is performed to demonstrate the effect of sampling time on noise, confirming theoretical expectations that doubling the sampling time while decreasing the re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90481-4

    authors: Hendrick RE

    更新日期:1987-01-01 00:00:00

  • A robust electrical conductivity imaging method with total variation and wavelet regularization.

    abstract:PURPOSE:This study aims to develop and evaluate a robust conductivity imaging method that combines total variation and wavelet regularization to enhance the accuracy of conductivity maps. THEORY AND METHODS:The proposed approach is based on a gradient-based method. The central equation is derived from Maxwell's equati...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.02.015

    authors: Sun X,Lu L,Qi L,Mei Y,Liu X,Chen W

    更新日期:2020-06-01 00:00:00

  • A spectroscopic NMR investigation of the calcium silicate hydrates present in cement and concrete.

    abstract::NMR spectroscopy is applied to study microstructure of calcium silicate hydrates present in cement and concrete. It is shown that 29Si NMR gives information on the siliceous skeleton of the hydrates. 1H NMR, using CRAMPS techniques, allows to discriminate between protons linked to silicon atoms or to calcium atoms. A ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00211-1

    authors: Zanni H,Rassem-Bertolo R,Masse S,Fernandez L,Nieto P,Bresson B

    更新日期:1996-01-01 00:00:00

  • Effects of osmotic manipulation of intracellular hydration of HeLa S-3 cells on their proton NMR relaxation times.

    abstract::Pellets of HeLa from suspension cultured cells in isotonic medium (300 mosmolar) were introduced into a Bruker CXP100 NMR spectrophotometer at 80 mHz within 5 min of the start of centrifugation. T1 and T2 times were measured within a total elapsed time of 20-25 min at 80 mHz and 37 degrees C, and averaged 1430 msec an...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90101-7

    authors: Wheatley DN,Rimmington JE,Foster MA

    更新日期:1990-01-01 00:00:00

  • Quantitative diffusion MRI using reduced field-of-view and multi-shot acquisition techniques: Validation in phantoms and prostate imaging.

    abstract:PURPOSE:To evaluate the reproducibility of quantitative diffusion measurements obtained with reduced Field of View (rFOV) and Multi-shot EPI (msEPI) acquisitions, using single-shot EPI (ssEPI) as a reference. METHODS:Diffusion phantom experiments, and prostate diffusion-weighted imaging in healthy volunteers and patie...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.04.006

    authors: Zhang Y,Holmes J,Rabanillo I,Guidon A,Wells S,Hernando D

    更新日期:2018-09-01 00:00:00

  • MRI of polysplenia syndrome.

    abstract::The polysplenia syndrome is the association of multiple spleens, situs inversus, congenital heart disease, and azygous continuation of the inferior vena cava. Magnetic resonance (MR) is a noninvasive imaging modality which can easily confirm the multiplicity of spleens, situs inversus, and identify complex congenital ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90538-9

    authors: Jelinek JS,Stuart PL,Done SL,Ghaed N,Rudd SA

    更新日期:1989-11-01 00:00:00

  • Technical evaluation of in vivo abdominal fat and IMCL quantification using MRI and MRSI at 3 T.

    abstract:OBJECTIVES:The objectives of this study were to develop protocols that measure abdominal fat and calf muscle lipids with magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), respectively, at 3 T and to examine the correlation between these parameters and insulin sensitivity. MATERIALS AND METHOD...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.06.006

    authors: Li X,Youngren JF,Hyun B,Sakkas GK,Mulligan K,Majumdar S,Masharani UB,Schambelan M,Goldfine ID

    更新日期:2008-02-01 00:00:00

  • In vivo nuclear magnetic resonance imaging and spectroscopy of aquatic organisms.

    abstract::NMR imaging and localized 1H spectroscopy of a variety of aquatic organisms in vivo is described for the first time. The practical consideration of life support, water volume, salinity, and anesthesia are discussed and solutions presented. Such animal studies shape our understanding of physiology, biochemistry, and bi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90253-x

    authors: Blackband SJ,Stoskopf MK

    更新日期:1990-01-01 00:00:00

  • A quantitative study of water proton relaxation in packed beds of porous particles with varying water content.

    abstract::A quantitative analysis of the dependence of water proton relaxation on water content in randomly packed beds of Sephadex is undertaken. A combination of Osmotic and Capillary theory is used to describe the morphological changes occurring in the packed beds as the water content is lowered. At each water content the wa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92032-x

    authors: Hills BP,Babonneau F

    更新日期:1994-01-01 00:00:00

  • Effects of 3D sampling in (k, t)-space on temporal qualities of dynamic MRI.

    abstract::3D (kx, ky, t)-space analysis is invoked to provide insights into dynamic magnetic resonance imaging (DMRI) with arbitrary k-space sampling trajectories. The effects of 3D sampling in (kx, ky, t) are analyzed theoretically and verified with computer simulation. The analyses show that a 3D sampling pattern that is more...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.04.009

    authors: Park JB,Nishimura DG

    更新日期:2006-10-01 00:00:00

  • Comparison of BLADE and conventional T2-TSE sequences for the sagittal visualization of the cervical spinal cord in multiple sclerosis patients - a case report.

    abstract::The purpose of this study is to report the significant differences found in the identification of lesions in cervical spinal cord of two patients with multiple sclerosis when using the BLADE T2-TSE and BLADE T2-TIRM sequences as opposed to the conventional T2-TSE and T2-TIRM sequences for sagittal acquisition at 1.5T....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.008

    authors: Lavdas E,Mavroidis P,Topaltzikis T,Slatinopoulos V,Roka V,Vlachopoulou A,Papanikolaou N,Stathakis S,Kapsalaki E,Batsikas G

    更新日期:2013-12-01 00:00:00

  • Artifacts in chemical shift selective imaging.

    abstract::The role of susceptibility effects in the production of artifacts in chemical shift images generated by the selective excitation technique is discussed. The effects are demonstrated in images of phantom samples of agarose gels containing small air bubbles. The artifacts can lead to erroneous interpretations, in which ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90022-r

    authors: Pope JM,Walker RR,Kron T

    更新日期:1992-01-01 00:00:00

  • MRI findings in pulmonary sarcoidosis.

    abstract::Postero-anterior radiographs and magnetic resonance imaging (MRI) of the chest were performed in nine biopsy proven cases of sarcoidosis. MRI was more sensitive than a postero-anterior chest roentgenogram in detecting hilar and mediastinal adenopathy but less informative in detecting pleural and parenchymal disease. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90131-2

    authors: Craig DA,Colletti PM,Ratto D,Gordonson JS,Raval JK,Sharma OP

    更新日期:1988-09-01 00:00:00

  • Applications of controlled-flow laser-polarized xenon gas to porous and granular media study.

    abstract::We report initial NMR studies of continuous flow laser-polarized xenon gas, both in unrestricted tubing, and in a model porous media. The study uses Pulsed Gradient Spin Echo-based techniques in the gas-phase, with the aim of obtaining more sophisticated information than just translational self-diffusion coefficients....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00156-5

    authors: Mair RW,Wang R,Rosen MS,Candela D,Cory DG,Walsworth RL

    更新日期:2003-04-01 00:00:00

  • Quantitative susceptibility mapping of prostate with separate calculations for water and fat regions for reducing shading artifacts.

    abstract::We propose a novel processing method for reducing shading artifacts in quantitative susceptibility mapping (QSM) for prostate imaging. In the conventional method, calculation errors in the boundary regions between water and fat cause shading artifacts that degrade the image quality for QSM. In the proposed method, wat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.11.006

    authors: Sato R,Shirai T,Soutome Y,Bito Y,Ochi H

    更新日期:2020-02-01 00:00:00

  • In vivo MR evaluation of Gd-DTPA conjugated to dextran in normal rabbits.

    abstract::A dextran-Gd-DTPA compound has been recently synthesized utilizing 70,800 Da molecular weight dextran. This polymeric contrast agent for magnetic resonance imaging has been found chemically to be very stable and to demonstrate in vitro improved relaxivities of 1.5 to 2.3 times that of monomeric Gd-DTPA at 100 MHz. Thi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90515-2

    authors: Li KC,Quisling RG,Armitage FE,Richardson D,Mladinich C

    更新日期:1992-01-01 00:00:00

  • Evaluation of EPI distortion correction methods for quantitative MRI of the brain at high magnetic field.

    abstract::High field MRI has been applied to high-resolution structural and functional imaging of the brain. Echo planar imaging (EPI) is an ultrafast acquisition technique widely used in diffusion imaging, functional MRI and perfusion imaging. However, it suffers from geometric and intensity distortions caused by static magnet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.06.010

    authors: Hong X,To XV,Teh I,Soh JR,Chuang KH

    更新日期:2015-11-01 00:00:00

  • Water diffusion in biological porous systems: a NMR approach.

    abstract::The spin-echo nuclear magnetic resonance (NMR) technique together with paramagnetic ion doping are used to study structural parameters of plant samples, such as restricted dimensions, and cell interconnection both through membranes and by cell contact by studying simultaneous restricted diffusion and intercellular wat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00053-8

    authors: Anisimov AV,Sorokina NY,Dautova NR

    更新日期:1998-06-01 00:00:00

  • Low-frequency signal changes reflect differences in functional connectivity between good readers and dyslexics during continuous phoneme mapping.

    abstract::The current fMRI study investigated correlations of low-frequency signal changes in the left inferior frontal gyrus, right inferior frontal gyrus and cerebellum in 13 adult dyslexic and 10 normal readers to examine functional networks associated with these regions. The extent of these networks to regions associated wi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.006

    authors: Stanberry LI,Richards TL,Berninger VW,Nandy RR,Aylward EH,Maravilla KR,Stock PS,Cordes D

    更新日期:2006-04-01 00:00:00

  • Visualisation of changes in regional cerebral blood flow (rCBF) produced by ketamine using long TE gradient-echo sequences: preliminary results.

    abstract::Autoradiographic studies have shown that low dose ketamine produces increases in regional glucose utilisation and blood flow in the hippocampus, cerebral cortex, and olfactory lobe in the rat brain, probably due to antagonism at the NMDA receptor. Functional MRI using deoxyhaemoglobin contrast can be used to study cha...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00010-e

    authors: Burdett NG,Menon DK,Carpenter TA,Jones JG,Hall LD

    更新日期:1995-01-01 00:00:00

  • Balanced steady state free precession for arterial spin labeling MRI: Initial experience for blood flow mapping in human brain, retina, and kidney.

    abstract::We implemented pseudo-continuous ASL (pCASL) with 2D and 3D balanced steady state free precession (bSSFP) readout for mapping blood flow in the human brain, retina, and kidney, free of distortion and signal dropout, which are typically observed in the most commonly used echo-planar imaging acquisition. High resolution...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.03.024

    authors: Park SH,Wang DJ,Duong TQ

    更新日期:2013-09-01 00:00:00