Abstract:
PURPOSE:To evaluate the influence of cholecystectomy on the flow dynamic pattern of bile in the extrahepatic bile duct by using cine-dynamic MRCP with spatially-selective inversion-recovery (IR) pulse non-invasively. MATERIALS AND METHODS:56 patients with cholecystectomy and 48 control subjects without cholecystectomy who underwent cine-dynamic MRCP with spatially-selective IR pulse at 1.5 T or 3 T (TR/TE, 4000 msec/500 msec; echo train spacing, 6.5 msec; echo train length, 172; section thickness, 50 mm; matrix, 320 × 320; field of view, 320 × 320 mm; bandwidth, 488 Hz; and inversion time, 2200 msec). In cine-dynamic MRCP, IR pulse with 20 mm width was placed on the common bile duct (CBD) to evaluate the movement of bile (antegrade and reversed bile flow). Cine-dynamic MRCP imaging was scanned every 15 s (imaging, 4 s; rest, 11 s) during 5 min to acquire a series of single-shot images (a total of 20 images). The frequency that antegrade or reversed bile flow was observed in the extrahepatic bile duct, and 5-point grading score based on the moving distance of antegrade or reversed bile flow were compared between the groups. Both groups were compared using the χ2 and Mann-Whitney U tests (P < 0.05 considered significant). RESULTS:Antegrade bile flow was observed more frequently in the cholecystectomy group than in the non-cholecystectomy group (5.1 times vs. 2.8 times, P = 0.008). Mean grading score of antegrade bile flow was significantly greater in the cholecystectomy group than in the non-cholecystectomy group (mean grade, 0.33 vs 0.21; P = 0.014). Regarding reversed bile flow, there were no significant differences in the frequency and grading score between cholecystectomy group and non-cholecystectomy group. CONCLUSION:Antegrade bile flow was observed more frequently and predominantly in patients after cholecystectomy in cine-dynamic MRCP with spatially-selective IR pulse while reversed bile flow was observed equivalently.
journal_name
Magn Reson Imagingjournal_title
Magnetic resonance imagingauthors
Sotozono H,Tamada T,Kanki A,Yasokawa K,Fukunaga T,Yamamoto A,Ito Kdoi
10.1016/j.mri.2020.08.016subject
Has Abstractpub_date
2020-12-01 00:00:00pages
213-222eissn
0730-725Xissn
1873-5894pii
S0730-725X(19)30469-2journal_volume
74pub_type
杂志文章abstract::Recent compressed sensing techniques allow signal acquisition with less sampling than required by the Nyquist-Shannon theorem which reduces the data acquisition time in magnetic resonance imaging (MRI). However, prior knowledge becomes essential to reconstruct detailed features when the sampling rate is exceedingly lo...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2015.10.009
更新日期:2016-02-01 00:00:00
abstract::The analysis of functional magnetic resonance imaging (fMRI) data involves multiple stages of data pre-processing before the activation can be statistically detected. Spatial smoothing is a very common pre-processing step in the analysis of functional brain imaging data. This study presents a broad perspective on the ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.08.006
更新日期:2008-05-01 00:00:00
abstract::Selective inversion recovery (SIR) is a quantitative magnetization transfer (qMT) method that provides estimates of parameters related to myelin content in white matter, namely the macromolecular pool-size-ratio (PSR) and the spin-lattice relaxation rate of the free pool (R1f), without the need for independent estimat...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2020.01.014
更新日期:2020-05-01 00:00:00
abstract::Rapid maturational brain changes occur during adolescence--a time associated with risk-taking behaviors and improvements in cognition. The present study examined the relationship between white matter (WM) microstructure, impulsive behavior and response inhibition in female and male adolescents. Twenty-one healthy adol...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2006.03.012
更新日期:2006-09-01 00:00:00
abstract::The presence of metallic compounds in facial cosmetics and permanent tattoos may affect the quality of magnetic resonance imaging. We report a case study describing a signal artifact due to the use of a leave-on powdered hair dye. On reviewing the ingredients of the product, it was found to contain several metallic co...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.08.023
更新日期:2017-01-01 00:00:00
abstract::Compressed sensing has shown great potential in reducing data acquisition time in magnetic resonance imaging (MRI). In traditional compressed sensing MRI methods, an image is reconstructed by enforcing its sparse representation with respect to a preconstructed basis or dictionary. In this paper, patch-based directiona...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.02.019
更新日期:2012-09-01 00:00:00
abstract:PURPOSE:The purposes of this study were to (1) correlate the ultrashort echo time (TE) signal intensity of the pointwise encoding time reduction with radial acquisition (PETRA) sequence with that of the ultrashort echo (UTE) sequence using in vivo meniscal ultrashort TE imaging of the knee with a 3-Tesla (3T) clinical ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2015.09.003
更新日期:2016-02-01 00:00:00
abstract::Parallel excitation using multiple transmit channels has emerged as an effective method to shorten multidimensional spatially selective radiofrequency (RF) pulses, which have a number of important applications, including B1 field inhomogeneity correction in high-field MRI. The specific absorption rate (SAR) is a prima...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2008.02.003
更新日期:2008-10-01 00:00:00
abstract:PURPOSE:To implement and evaluate interleaved blip-up, blip-down, non-segmented 3D echo planar imaging (EPI) with pseudo-continuous arterial spin labeling (pCASL) and post-processing for reduced susceptibility artifact cerebral blood flow (CBF) maps. MATERIALS AND METHODS:3D EPI non-segmented acquisition with a pCASL ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2017.08.011
更新日期:2017-12-01 00:00:00
abstract::Zero-mean noise introduced into quadrature detected MRI signals is generally rectified by the reconstruction algorithm to give a nonzero background intensity in the displayed image. In low signal-to-noise ratio (SNR) images, this background will inflate region of interest (ROI) signal measurements, leading to improper...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(93)90225-3
更新日期:1993-01-01 00:00:00
abstract::Increasing scientific interest in the zebrafish as a model organism across a range of biomedical and biological research areas raises the need for the development of in vivo imaging tools appropriate to this subject. Development of the embryonic and early stage forms of the subject can currently be assessed using opti...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.10.013
更新日期:2017-04-01 00:00:00
abstract::Non-CE MRA techniques (true steady-state free-precession, SSFP) have been used effectively for the selective visualization of the portal venous system and inferior vena cava. Budd-Chiari Syndrome (BCS) encompasses a number of conditions that cause the obstruction of the hepatic outflow tract from the small hepatic vei...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.10.006
更新日期:2017-02-01 00:00:00
abstract::Combining electrical stimulation with fMRI (esfMRI) has proven to be an important tool to study the global effects of electrical stimulation on neural networks in the brain. Here we extend our previous studies to stimulating the upper superior temporal sulcus (STS) in the anesthetized monkey. Our results show that sti...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2011.04.005
更新日期:2011-12-01 00:00:00
abstract::In vivo proton and phosphorus magnetic resonance spectroscopy (MRS) studies were performed at 1.5 T on two patients (siblings) diagnosed as having a mitochondrial cytopathy. The clinical diagnosis was based on a complete battery of biochemical tests, electron microscopy and modified Gomori trichrome stain studies of m...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(89)90695-4
更新日期:1989-03-01 00:00:00
abstract::Gravity drainage characteristics are important to improve our understanding of gas-liquid or liquid-liquid two-phase flow in porous media. Stable or unstable displacement fronts that controlled by the capillary force, viscous force, gravitational force, etc., are relevant features of immiscible two-phase flow. In this...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.03.004
更新日期:2016-09-01 00:00:00
abstract::A new application of the stimulated echo pulse sequence is presented that permits the elucidation of molecular order and dynamics in a time scale between about 100 microseconds and the spin-lattice relaxation time. The technique exploits the influence of dipolar coupling on the quotient of the stimulated and primary e...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(96)00172-5
更新日期:1996-01-01 00:00:00
abstract::Deep brain stimulation (DBS) is used increasingly in the field of movement disorders. The implanted electrodes create not only a prior risk to patient safety during MRI, but also a unique opportunity in the collection of functional MRI data conditioned by direct neural stimulation. We evaluated MRI-related heating for...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2005.02.007
更新日期:2005-05-01 00:00:00
abstract:PURPOSE:To provide a single open-source platform for comprehensive MR algorithm development inclusive of simulations, pulse sequence design and deployment, reconstruction, and image analysis. METHODS:We integrated the "Pulseq" platform for vendor-independent pulse programming with Graphical Programming Interface (GPI)...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2018.03.008
更新日期:2018-10-01 00:00:00
abstract::Magnetic resonance imaging (MRI) and spectroscopy (MRS) have contributed considerably to clinical radiology, and a variety of MR techniques have been developed to evaluate pathological processes as well as normal tissue biology at the cellular and molecular level. However, in comparison to nuclear imaging, MRI has rel...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.12.008
更新日期:2017-05-01 00:00:00
abstract::Microscopic magnetic resonance elastography is a high-resolution method for visualizing shear waves and assessing the biomechanical viscoelastic properties of small biological samples. In this work, we used error propagation to develop a simple analytical model that relates the signal-to-noise ratio of MR magnitude im...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2006.09.040
更新日期:2007-01-01 00:00:00
abstract::Relaxation times estimation methods play a central role in various problems, such as magnetic resonance (MR) hardware calibration, tissue characterization, or temperature measurement. Previous studies have proposed optimization criteria to estimate the relaxation time T1 faster than with a multipoint method leading to...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(99)00092-2
更新日期:1999-11-01 00:00:00
abstract::The effects of varying the inversion or excitation RF pulse flip angles on image contrast and imaging time have been investigated in IR imaging theoretically, with phantoms and with normal volunteers. Signal intensity in an IR pulse sequence as a function of excitation, inversion and refocusing pulse flip angles was c...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(92)90481-e
更新日期:1992-01-01 00:00:00
abstract::Gadolinium-based magnetic resonance (MR) contrast agents (GBCM) causes a devastating systemic fibrosing illness, nephrogenic systemic fibrosis (NSF), in patients with reduced kidney function. GBCM targets iron-recycling CD163- and ferroportin-expressing macrophages to release labile iron that mediates gadolinium toxic...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章,评审
doi:10.1016/j.mri.2016.08.016
更新日期:2016-12-01 00:00:00
abstract::Brain alcohol was measured in rhesus monkeys (Macaca mulatta) by proton magnetic resonance spectroscopy (MRS) following acute nasogastric alcohol administration (0.8 g/kg). Monkeys were anesthetized with ketamine and xylazine. A 1.5 T whole body imager and a 3-inch surface coil were used to acquire TE 30 and 270 ms sp...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)90089-a
更新日期:1994-01-01 00:00:00
abstract:OBJECTIVE:The pathological changes in Parkinson disease begin in the brainstem; reach the limbic system and ultimately spread to the cerebral cortex. In Parkinson disease (PD) patients, we evaluated the alteration of cingulate fibers, which comprise part of the limbic system, by using diffusional kurtosis imaging (DKI)...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.06.009
更新日期:2013-11-01 00:00:00
abstract::The polysplenia syndrome is the association of multiple spleens, situs inversus, congenital heart disease, and azygous continuation of the inferior vena cava. Magnetic resonance (MR) is a noninvasive imaging modality which can easily confirm the multiplicity of spleens, situs inversus, and identify complex congenital ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(89)90538-9
更新日期:1989-11-01 00:00:00
abstract::In this retrospective study we tested the hypothesis that the net effect of impaired electrical conduction and therefore increased heat dissipation in multiple sclerosis (MS) results in elevated lateral ventricular (LV) cerebrospinal fluid (CSF) diffusivity as a measure of brain temperature estimated in vivo using dif...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.11.002
更新日期:2015-04-01 00:00:00
abstract::Many informatics tools have emerged to process the voluminous and complex data generated by functional magnetic resonance imaging (fMRI). The interpretation of fMRI exams is largely determined by these tools. However, their performance is hard to evaluate because there is no independent means of calibration. A novel f...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2005.12.012
更新日期:2006-04-01 00:00:00
abstract:PURPOSE:To implement and evaluate the accuracy of non-invasive temperature mapping using MRI methods based on the chemical shift (CS) and T1 relaxation in media of various heterogeneity during focal (laser) and external thermal energy deposition. MATERIALS AND METHODS:All measurements were performed on a 1.5 T superco...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(97)00311-1
更新日期:1998-05-01 00:00:00
abstract::Glycosaminoglycan Chemical Exchange Saturation Transfer (gagCEST) is an important molecular MRI methodology developed to assess changes in cartilage GAG concentrations. The correction for B0 field inhomogeneity is technically crucial in gagCEST imaging. This study evaluates the accuracy of the B0 estimation determined...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.07.009
更新日期:2014-01-01 00:00:00