Abstract:
PURPOSE:To develop a free-running framework for 3D isotropic simultaneous myocardial T1/T2 mapping and cine imaging. METHODS:Continuous data acquisition with 3D golden angle radial trajectory is used in conjunction with T2 preparation of varying echo times and inversion recovery (IR) pulses to enable simultaneous myocardial T1/T2 mapping and cine imaging. Data acquisition is retrospectively synchronized with ECG signal, and 1D respiratory self-navigation signal is extracted from the k-space center of all radial spokes. Respiratory binning is performed based on the estimated respiratory signal, enabling estimation and correction of 3D translational respiratory motion. Using high-dimensionality patch-based undersampled reconstruction with dictionary-based low-rank inversion, whole-heart T1/T2 maps and cine images can be generated with 2 mm isotropic spatial resolution. The proposed technique was validated in a standardised phantom and ten healthy subjects in comparison to conventional 2D imaging techniques. RESULTS:Phantom T1 and T2 measurements demonstrated good agreement with 2D spin echo techniques. Septal T1 estimated with the proposed technique (1185.6 ± 49.8 ms) was longer than with a conventional breath-hold 2D IR-prepared sequence (1044.3 ± 26.7 ms), whereas T2 measurements (47.6 ± 2.5 ms) were lower than a breath-hold 2D gradient spin echo sequence (52.0 ± 1.8 ms). Precision of the proposed 3D mapping was higher than conventional 2D mapping techniques. Ejection fraction measured with the proposed 3D approach (63.8 ± 6.8%) agreed well with conventional breath-held multi-slice 2D cine (62.3 ± 6.4%). CONCLUSIONS:The proposed technique provides co-registered 3D T1/T2 maps and cine images with isotropic spatial resolution from a single free-breathing scan, thereby providing a promising imaging tool for whole-heart myocardial tissue characterization and functional evaluation.
journal_name
Magn Reson Imagingjournal_title
Magnetic resonance imagingauthors
Qi H,Bustin A,Cruz G,Jaubert O,Chen H,Botnar RM,Prieto Cdoi
10.1016/j.mri.2019.08.008subject
Has Abstractpub_date
2019-11-01 00:00:00pages
159-169eissn
0730-725Xissn
1873-5894pii
S0730-725X(19)30384-4journal_volume
63pub_type
杂志文章abstract:PURPOSE:To prospectively compare image quality and reliability of a non-contrast, self-navigated 3D whole-heart magnetic resonance angiography (MRA) sequence with contrast-enhanced computed tomography angiography (CTA) for sizing of thoracic aortic aneurysm (TAA). METHODS:Self-navigated 3D whole-heart 1.5 T MRA was pe...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2020.12.003
更新日期:2021-02-01 00:00:00
abstract:OBJECTIVE:To develop and validate a large field of view phantom and quality assurance software tool for the assessment and characterization of geometric distortion in MRI scanners commissioned for radiation therapy planning. MATERIALS AND METHODS:A purpose built phantom was developed consisting of 357 rods (6mm in dia...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章,评审
doi:10.1016/j.mri.2015.04.003
更新日期:2015-09-01 00:00:00
abstract:PURPOSE:To evaluate whether semi-quantitative analysis of high temporal resolution dynamic contrast-enhanced MRI (DCE-MRI) acquired early in treatment can predict the response of locally advanced breast cancer (LABC) to neoadjuvant chemotherapy (NAC). MATERIALS AND METHODS:As part of an IRB-approved prospective study,...
journal_title:Magnetic resonance imaging
pub_type: 临床试验,杂志文章
doi:10.1016/j.mri.2013.07.002
更新日期:2013-11-01 00:00:00
abstract::Perfusion magnetic resonance imaging (MRI) is a promising non-invasive technique providing insights regarding the brain's microvascular architecture in vivo. The scalar perfusion metrics can be used for quantitative diagnostics of various brain abnormalities, in particular, in the stroke cases and tumours. However, co...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2018.11.007
更新日期:2019-04-01 00:00:00
abstract::The medical specialty radiology has experienced a number of extremely important and influential technical developments in the past that have affected how medical imaging is deployed. Artificial intelligence (AI) is potentially another such development that will introduce fundamental changes into the practice of radiol...
journal_title:Magnetic resonance imaging
pub_type: 社论
doi:10.1016/j.mri.2019.12.006
更新日期:2020-05-01 00:00:00
abstract::Traumatic brain injury (TBI) is one of the commonest causes of morbidity and mortality in the developed countries with posttraumatic epilepsy and functional disability being its major sequelae. The purpose of this study was to test the hypothesis whether the normal appearing adjacent gray and white matter regions on T...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(03)00189-9
更新日期:2003-10-01 00:00:00
abstract::Hippocampal metabolite concentrations were determined by localized in vivo proton magnetic resonance spectroscopy (1H MRS) in eleven patients suffering from refractory mesial temporal lobe epilepsy (MTLE), as well as in eleven age-matched healthy volunteers, and compared with patient history, postoperative outcome and...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00123-4
更新日期:1998-10-01 00:00:00
abstract:OBJECTIVES:To investigate the feasibility of chemical exchange saturation transfer (CEST) MRI in patients with breast carcinomas and possible correlations between magnetization transfer asymmetry (MTRasym) values and histological features, such as tumor grade and the Ki-67 proliferation index. MATERIALS AND METHODS:Ni...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.03.004
更新日期:2019-06-01 00:00:00
abstract::Diabetic retinopathy (DR) is one of a major complication of type 1 diabetes mellitus (T1DM) and a leading cause of blindness. Evidence of animal study has shown that it is not only a microvasucular lesion of the eye, but also a neurodegeneration disease of the visual system. However, the in vivo imaging evidence of ax...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2020.05.003
更新日期:2020-09-01 00:00:00
abstract::Quantitative processing of NMR relaxation images depends on the characteristics of the used fitting algorithm. Therefore several common fitting algorithms are compared for decay curves with low signal-to-noise ratios. The use of magnitude data yields a non-zero base line, and is shown to result in an overestimation of...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(00)00200-9
更新日期:2000-11-01 00:00:00
abstract::The goal of this study was to determine whether presurgical metabolite levels measured by 3D MR Spectroscopic Imaging (MRSI) can accurately detect viable cancer within human brain tumor masses. A total of 31 patients (33 exams, 39 pathology correlations) with brain tumors were studied prior to surgical biopsy and/or r...
journal_title:Magnetic resonance imaging
pub_type: 临床试验,杂志文章
doi:10.1016/s0730-725x(01)00225-9
更新日期:2001-01-01 00:00:00
abstract::The intraductal papillary-mucinous neoplasm (IPMN) is the rarest of the cystic pancreatic tumors. Endoscopic retrograde cholangiopancreatography (ERCP) is currently the gold standard for evaluating IPMN's and can demonstrate dilatation of the main duct or side branches, mural nodules, filling defects, and communicatio...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(01)00440-4
更新日期:2001-10-01 00:00:00
abstract::Thoracic and abdominal magnetic resonance imaging studies generally require some type of compensation for respiratory and cardiac motions in order to yield artifact-free images with good signal-to-noise ratio. Most techniques for respiratory compensation require the use of a non-NMR sensing device to monitor the subje...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(01)00403-9
更新日期:2001-07-01 00:00:00
abstract::Geometric distortion in MR imaging predominantly arises from the inhomogeneity of the static field and the nonlinearity of the gradients. It is the purpose of this paper to analyse the object and machine related contributions to geometric distortion in order to determine which corrections are necessary for attaining a...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(92)90011-n
更新日期:1992-01-01 00:00:00
abstract::Diffusion tensor imaging (DTI) is potentially sensitive to collagen degeneration in cartilage. In this study, DTI was measured on human cartilage samples with interventions of trypsin and collagenase. The measured preferred diffusion direction was consistent with the zonal structure of collagen network. The glycosamin...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2006.10.015
更新日期:2007-02-01 00:00:00
abstract::For a number of reasons, it is desirable to fabricate coils which, for a known current, shall produce predetermined values of the magnetic field intensity at a number of points within a nuclear magnetic resonance imager. The calculation of the magnetic field intensity at a set of points involves the integration of the...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(89)90524-9
更新日期:1989-11-01 00:00:00
abstract::Functional magnetic resonance imaging (fMRI) has found widespread clinical interest. Difficulties in clinical use of the fMRI technique arise, considering the lack of knowledge about activation task performance. This accounts especially for sensorimotor activation studies, in which performance of the sensorimotor acti...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(95)02052-u
更新日期:1996-01-01 00:00:00
abstract::SSFP-based fMRI techniques, known for their high specificity and low geometrical distortion, look promising for high-resolution brain mapping. Nevertheless, they suffer from lack of speed and sensitivity, leading them to be exploited mostly in high-field scanners. Radial acquisition can help with these inefficiencies ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2020.09.005
更新日期:2020-12-01 00:00:00
abstract::Brain alcohol was measured in rhesus monkeys (Macaca mulatta) by proton magnetic resonance spectroscopy (MRS) following acute nasogastric alcohol administration (0.8 g/kg). Monkeys were anesthetized with ketamine and xylazine. A 1.5 T whole body imager and a 3-inch surface coil were used to acquire TE 30 and 270 ms sp...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)90089-a
更新日期:1994-01-01 00:00:00
abstract::Twenty-seven patients with soft-tissue tumors were examined with a Picker 0.15-tesla resistive magnet and by computed tomography (CT). In all but one patient, MRI was better than or equal to CT in defining the anatomic extent of the tumor. We could determine whether major vascular structures were engulfed by the tumor...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(85)90398-4
更新日期:1985-01-01 00:00:00
abstract::Currently, the North American symptomatic carotid endarterectomy trial, European carotid surgery trial, and common carotid method are used to measure the carotid stenosis for determining candidates for carotid endarterectomy using the projection angiography from different modalities such as digital subtraction angiogr...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2004.01.007
更新日期:2004-04-01 00:00:00
abstract:PURPOSE:The state-of-the-art method to quantify sodium concentrations in vivo consists in a fully relaxed 3D spin-density (SD) weighted acquisition. Nevertheless, most sodium MRI clinical studies use short-TR SD acquisitions to reduce acquisition durations. We present a clinically viable implementation of the Variable ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.01.015
更新日期:2019-05-01 00:00:00
abstract::MRI is applied to the visualisation of wetting heterogeneities evidenced by water proton T1 contrast at 0.1 T. Water saturated Fontainebleau sandstone samples were examined either in their original water-wet condition, or after silanation. T1, T2Hahn, and T2CPMG were measured for several porosities. T1 and T2CPMG of h...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)91557-1
更新日期:1994-01-01 00:00:00
abstract::Type A acute aortic dissection (TAAAD) sometimes presents with acute stroke-like symptoms. When intravenous tissue plasminogen activator (IV-tPA) therapy is considered for acute ischemic stroke, TAAAD must be excluded. Painless TAAAD presenting with acute stroke may be easily missed. Two cases of painless TAAAD presen...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.04.021
更新日期:2016-09-01 00:00:00
abstract::With the recent development of integrated positron emission tomography-magnetic resonance imaging (PET-MRI) scanners, new possibilities for quantitative molecular imaging of cancer are realized. However, the practical advantages and potential clinical benefits of the ability to record PET and MRI data simultaneously m...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章,评审
doi:10.1016/j.mri.2012.06.001
更新日期:2012-11-01 00:00:00
abstract::Water content is the dominant chemical compound in the brain and it is the primary determinant of tissue contrast in magnetic resonance (MR) images. Water content varies greatly between individuals, and it changes dramatically over time from birth through senescence of the human life span. We hypothesize that the effe...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.07.017
更新日期:2013-12-01 00:00:00
abstract::The local determination of porosity is an extremely valuable target because of different applications in petrophysics. In fact, obtaining a reliable profile of porosity or saturations could considerably improve the evaluation of transport properties of porous media, especially if applied to multiphase flow test (i.e.,...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(96)00182-8
更新日期:1996-01-01 00:00:00
abstract:PURPOSE:Although functional magnetic resonance imaging (fMRI) has revealed that spinal cord injury (SCI) causes anomalous changes in task-induced brain activation, its effect during the resting state remains unclear. The aim of this study is to explore the changes of the brain resting-state function in non-human primat...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.02.001
更新日期:2014-06-01 00:00:00
abstract::Using both quantitative computer-assisted analysis and visual estimation the MR imaging response of brain metastases to whole-brain radiotherapy (WBRT) was prospectively studied in 49 patients. Compared to the computer-assisted analysis, the precision of the visual estimation (by two readers in conference) of tumor re...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(96)00024-0
更新日期:1997-01-01 00:00:00
abstract::Our purpose was to investigate three-dimensional (3D) gadolinium-enhanced magnetic resonance angiography (Gd-MRA) in the evaluation of renal transplant arteries. Eleven MR angiography examinations were performed in nine renal transplant patients. Gd-MRA, three-dimensional phase contrast (3D-PC) post-gadolinium, and tw...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(96)00348-7
更新日期:1997-01-01 00:00:00