Ovarian Brenner tumors: MR imaging characteristics.

Abstract:

:This study describes the appearance of Brenner tumors on MR imaging and compares quantitative signal intensity measurements of Brenner tumors with that of other ovarian tumors. A search of pathologic and MR records disclosed patients who had MRIs showing Brenner tumors prior to surgical excision. Patients (21) with other surgically proven ovarian masses were randomly selected for comparison. MR imaging was performed at 1.5 T with phased array multicoils and fast spin echo T2-weighted images. Region-of-interest measurements of signal intensity (SI) were made to calculate signal intensity ratios (SIR = mass SI/muscle SI). Brenner tumors showed significantly lower SIR than other tumors on T2-weighted images (p = 0.004) and similar SIR on T1-weighted images. Brenner tumors show lower signal intensity on T2-weighted images than other non-fibrous ovarian tumors. This lower signal intensity may result from the extensive fibrous content of these tumors.

journal_name

Magn Reson Imaging

authors

Outwater EK,Siegelman ES,Kim B,Chiowanich P,Blasbalg R,Kilger A

doi

10.1016/s0730-725x(98)00136-2

subject

Has Abstract

pub_date

1998-12-01 00:00:00

pages

1147-53

issue

10

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(98)00136-2

journal_volume

16

pub_type

临床试验,杂志文章,随机对照试验
  • Dependence of temporal diffusion spectra on microstructural properties of biological tissues.

    abstract::The apparent diffusion coefficient (ADC) measured using magnetic resonance imaging methods provides information on microstructural properties of biological tissues, and thus has found applications as a useful biomarker for assessing changes such as those that occur in ischemic stroke and cancer. Conventional pulsed gr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.10.002

    authors: Xu J,Does MD,Gore JC

    更新日期:2011-04-01 00:00:00

  • Differentiation of hepatic cavernous hemangioma from metastases by rare sequence MR imaging.

    abstract::In this study, in order to differentiate cavernous hemangioma and hepatic metastases, rapid acquisition relaxation enhanced (RARE) sequence was used. First, in vivo measurements of T1, T2 relaxation times and proton density were obtained using T1, T2 calculation protocol (TOMIKON S50, 0.5T) and multipoint techniques. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00008-9

    authors: Jafari F,Nayeri N,Tahsini M,Khodadoust AA

    更新日期:1999-06-01 00:00:00

  • Three-dimensional adiabatic inversion recovery prepared ultrashort echo time cones (3D IR-UTE-Cones) imaging of cortical bone in the hip.

    abstract:PURPOSE:We present three-dimensional adiabatic inversion recovery prepared ultrashort echo time Cones (3D IR-UTE-Cones) imaging of cortical bone in the hip of healthy volunteers using a clinical 3T scanner. METHODS:A 3D IR-UTE-Cones sequence, based on a short pulse excitation followed by a 3D Cones trajectory, with a ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.07.012

    authors: Nazaran A,Carl M,Ma Y,Jerban S,Zhu Y,Lu X,Du J,Chang EY

    更新日期:2017-12-01 00:00:00

  • Assessment of cardiac iron by MRI susceptometry and R2* in patients with thalassemia.

    abstract::A magnetic resonance imaging cardiac magnetic susceptometry (MRI-CS) technique for assessing cardiac tissue iron concentration based on phase mapping was developed. Normal control subjects (n=9) and thalassemia patients (n=13) receiving long-term blood transfusion therapy underwent MRI-CS and MRI measurements of the c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.12.001

    authors: Wang ZJ,Fischer R,Chu Z,Mahoney DH Jr,Mueller BU,Muthupillai R,James EB,Krishnamurthy R,Chung T,Padua E,Vichinsky E,Harmatz P

    更新日期:2010-04-01 00:00:00

  • Anisotropic diffusion in etched particle tracks studied by field gradient NMR.

    abstract::Etched particle tracks produced after heavy ion irradiation of polymer foils are used as model systems to test the performance of NMR in a newly developed ultrahigh magnetic field gradient system. The stimulated NMR echo decay of molecules diffusing in the channels, formulated in terms of the self part of the intermed...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91527-x

    authors: Fujara F,Ilyina E,Nienstaedt H,Sillescu H,Spohr R,Trautmann C

    更新日期:1994-01-01 00:00:00

  • Monitoring brain tumor response to therapy using MRI segmentation.

    abstract::The performance evaluation of a semi-supervised fuzzy c-means (SFCM) clustering method for monitoring brain tumor volume changes during the course of routine clinical radiation-therapeutic and chemo-therapeutic regimens is presented. The tumor volume determined using the SFCM method was compared with the volume estima...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00386-4

    authors: Vaidyanathan M,Clarke LP,Hall LO,Heidtman C,Velthuizen R,Gosche K,Phuphanich S,Wagner H,Greenberg H,Silbiger ML

    更新日期:1997-01-01 00:00:00

  • Proton density water fraction as a biomarker of bone marrow cellularity: validation in ex vivo spine specimens.

    abstract::The purpose of this study was to evaluate a magnetic resonance imaging (MRI) technique for quantifying the proton density water fraction (PDWF) as a biomarker of bone marrow cellularity. Thirty-six human bone marrow specimens from 18 donors were excised and subjected to different measurements of tissue composition: PD...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.03.005

    authors: MacEwan IJ,Glembotski NE,D'Lima D,Bae W,Masuda K,Rashidi HH,Mell LK,Bydder M

    更新日期:2014-11-01 00:00:00

  • Spiral demystified.

    abstract::Spiral acquisition schemes offer unique advantages such as flow compensation, efficient k-space sampling and robustness against motion that make this option a viable choice among other non-Cartesian sampling schemes. For this reason, the main applications of spiral imaging lie in dynamic magnetic resonance imaging suc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2010.03.036

    authors: Delattre BM,Heidemann RM,Crowe LA,Vallée JP,Hyacinthe JN

    更新日期:2010-07-01 00:00:00

  • Magnetic resonance imaging at frequencies below 1 kHz.

    abstract::Within the magnetic resonance imaging (MRI) community the trend is going to higher and higher magnetic fields, ranging from 1.5 T to 7 T, corresponding to Larmor frequencies of 63.8-298 MHz. Since for high-field MRI the magnetization increases with the applied magnetic field, the signal-to-noise-ratio increases as wel...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.014

    authors: Hilschenz I,Körber R,Scheer HJ,Fedele T,Albrecht HH,Mario Cassará A,Hartwig S,Trahms L,Haase J,Burghoff M

    更新日期:2013-02-01 00:00:00

  • A CT using longitudinally detected ESR (LODESR-CT) of intraperitoneally injected nitroxide radical in a rat's head.

    abstract::We have developed an in vivo longitudinally detected ESR (LODESR) imaging system operating at 700 MHz based on a loop-gap resonator and a pair of saddle-type pickup coils. A good linear relationship between the LODESR signal intensity and the applied power in a range up to 15.8 W was obtained. The detection of LODESR ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)82763-4

    authors: Yokoyama H,Sato T,Tsuchihashi N,Ogata T,Ohya-Nishiguchi H,Kamada H

    更新日期:1997-01-01 00:00:00

  • Pure uterine lipoma.

    abstract::Lipomatous tumors of the uterus are unusual, benign neoplasms seen in postmenopausal women. Although many of the mixed-type cases such as lipoleiomyoma and fibrolipoma have been reported, pure uterine lipomas are extremely rare. In the literature, a few cases with pure uterine lipoma have been reported. We first prese...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.01.116

    authors: Erdem G,Celik O,Karakas HM,Alkan A,Hascalik S

    更新日期:2007-10-01 00:00:00

  • The NMR-MOUSE: quality control of elastomers.

    abstract::New applications of the NMR-MOUSE (mobile universal surface explorer) to non-destructive quality control of elastomers are reported. One example concern the thermal aging of fast clutches which was probed by measurements of 1H transverse relaxation time. Novel methodological developments show that 1H double-quantum fi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00277-6

    authors: Kühn H,Klein M,Wiesmath A,Demco DE,Blümich B,Kelm J,Gold PW

    更新日期:2001-04-01 00:00:00

  • In vitro adrenal cortex lesions characterization by NMR spectroscopy.

    abstract::Percentage of lipid content of 22 adrenal cortex lesions and their water proton longitudinal relaxation time were measured in vitro at 60 MHz. Although water relaxation times obtained on benign and malignant samples overlap each other, measurements of the percentage of lipids performed on the same tissues allow us to ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90123-8

    authors: Leroy-Willig A,Roucayrol JC,Luton JP,Courtieu J,Niesenbaum N,Louvel A

    更新日期:1987-01-01 00:00:00

  • Balanced multi-image demons for non-rigid registration of magnetic resonance images.

    abstract::A new approach is introduced for non-rigid registration of a pair of magnetic resonance images (MRI). It is a generalization of the demons algorithm with low computational cost, based on local information augmentation (by integrating multiple images) and balanced implementation. Specifically, a single deformation that...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.09.013

    authors: Mesin L

    更新日期:2020-12-01 00:00:00

  • Noninvasive evaluation of radiation-enhanced glioma cells invasiveness by ultra-high-field (1)H-MRS in vitro.

    abstract:INTRODUCTION:Glioma is the most common type of the primary CNS tumor. Radiotherapy is an important treatment measure after surgery. However, its highly invasive character is the main reason of postoperative recurrence. The aim of the study was to probe the correlation between the invasion ability and the metabolite cha...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.05.009

    authors: Xu YJ,Cui Y,Li HX,Shi WQ,Li FY,Wang JZ,Zeng QS

    更新日期:2016-10-01 00:00:00

  • Fast multi-contrast MRI reconstruction.

    abstract::Multi-contrast magnetic resonance imaging (MRI) is a useful technique to aid clinical diagnosis. This paper proposes an efficient algorithm to jointly reconstruct multiple T1/T2-weighted images of the same anatomical cross section from partially sampled k-space data. The joint reconstruction problem is formulated as m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.025

    authors: Huang J,Chen C,Axel L

    更新日期:2014-12-01 00:00:00

  • Comparison of different methods for combining phase-contrast images obtained with multiple coils.

    abstract::The ability to determine coil sensitivities implies that a method optimized in terms of maximized signal-to-noise ratio (SNR) can be applied to the combination of multiple coil images. An optimization of SNR subsequently results in a minimized variance in quantitative velocity measurements using phase-contrast imaging...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.06.002

    authors: Thunberg P,Karlsson M,Wigström L

    更新日期:2005-09-01 00:00:00

  • In vivo T1 characterization of genetically induced muscle atrophy.

    abstract::In vivo spin-lattice relaxation times, T1, of water and lipid protons of normal and atrophic muscles were measured, using the spatially resolved spectroscopy (SPARS) sequence, in a genetic avian model of myopathy. These T1 values were compared with those of the hypertrophic muscles. Although the water T1 values of mus...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90550-x

    authors: Misra LK,Narayana PA

    更新日期:1989-05-01 00:00:00

  • Interpretation of restricted diffusion in sandstones with internal field gradients.

    abstract::We report on experiments to characterize internal magnetic field gradients that are caused by magnetic susceptibility differences between the solid phase and the fluids filling the pore space. Our measurements focus on low-field relaxometry of brine and oil in sandstones from various reservoirs around the world. Our r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00287-9

    authors: Appel M,Freeman JJ,Gardner JS,Hirasaki GH,Zhang QG,Shafer JL

    更新日期:2001-04-01 00:00:00

  • Reducing SAR in parallel excitation using variable-density spirals: a simulation-based study.

    abstract::Parallel excitation using multiple transmit channels has emerged as an effective method to shorten multidimensional spatially selective radiofrequency (RF) pulses, which have a number of important applications, including B1 field inhomogeneity correction in high-field MRI. The specific absorption rate (SAR) is a prima...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.02.003

    authors: Liu Y,Feng K,McDougall MP,Wright SM,Ji J

    更新日期:2008-10-01 00:00:00

  • High-resolution in vivo diffusion tensor imaging of the injured cat spinal cord using self-navigated, interleaved, variable-density spiral acquisition (SNAILS-DTI).

    abstract::Diffusion tensor magnetic resonance imaging (DTI) is useful for studying the microstructural changes in the spinal cord following traumatic injury; however, image quality is generally poor due to the small size of the spinal cord, physiological motion and susceptibility artifacts. Self-navigated, interleaved, variable...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.06.006

    authors: Ellingson BM,Sulaiman O,Kurpad SN

    更新日期:2010-11-01 00:00:00

  • Manifestation and post hoc correction of gradient cross-term artifacts in DTI.

    abstract::Cross-terms between imaging and diffusion gradients, unaccounted for during tensor calculations, can lead to erroneous estimation of diffusivity and fractional anisotropy (FA) in regions of isotropic and anisotropic diffusion. Cross-term of magnitude 136.8±1.6 s/mm(2), artificially introduced in the slice-encode direc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.02.021

    authors: Nair G,Hu XP

    更新日期:2012-07-01 00:00:00

  • Assessment of myocardial perfusion using multisection first-pass MRI and color-coded parameter maps: a comparison to 99mTc Sesta MIBI SPECT and systolic myocardial wall thickening analysis.

    abstract::The most recently reported magnetic resonance first-pass myocardial perfusion studies were restricted to single slice imaging or a data analysis based on interactively placed regions of interest. This study was designed to investigate a new saturation recovery TurboFLASH sequence for multisection myocardial perfusion ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00166-0

    authors: Penzkofer H,Wintersperger BJ,Knez A,Weber J,Reiser M

    更新日期:1999-02-01 00:00:00

  • Pulseq-Graphical Programming Interface: Open source visual environment for prototyping pulse sequences and integrated magnetic resonance imaging algorithm development.

    abstract:PURPOSE:To provide a single open-source platform for comprehensive MR algorithm development inclusive of simulations, pulse sequence design and deployment, reconstruction, and image analysis. METHODS:We integrated the "Pulseq" platform for vendor-independent pulse programming with Graphical Programming Interface (GPI)...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.03.008

    authors: Ravi KS,Potdar S,Poojar P,Reddy AK,Kroboth S,Nielsen JF,Zaitsev M,Venkatesan R,Geethanath S

    更新日期:2018-10-01 00:00:00

  • Is 'virtual histology' the next step after the 'virtual autopsy'? Magnetic resonance microscopy in forensic medicine.

    abstract:AIM:The study aimed to validate magnetic resonance microscopy (MRM) studies of forensic tissue specimens (skin samples with electric injury patterns) against the results from routine histology. METHODS AND RESULTS:Computed tomography and magnetic resonance imaging are fast becoming important tools in clinical and fore...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.08.019

    authors: Thali MJ,Dirnhofer R,Becker R,Oliver W,Potter K

    更新日期:2004-10-01 00:00:00

  • High-resolution gadolinium-enhanced 3D MRA of the infrapopliteal arteries. Lessons for improving bolus-chase peripheral MRA.

    abstract::Peripheral magnetic resonance angiography (MRA) is growing in use. However, methods of performing peripheral MRA vary widely and continue to be optimized, especially for improvement in illustration of infrapopliteal arteries. The main purpose of this project was to identify imaging factors that can improve arterial vi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00531-3

    authors: Hood MN,Ho VB,Foo TK,Marcos HB,Hess SL,Choyke PL

    更新日期:2002-09-01 00:00:00

  • Magnetization transfer of water T(2) relaxation components in human brain: implications for T(2)-based segmentation of spectroscopic volumes.

    abstract::Biexponential T(2) relaxation of the localized water signal can be used for segmentation of spectroscopic volumes. To assess the specificity of the components an iterative relaxation measurement of the localized water signal (STEAM, 12 echo times, geometric spacing from 30 ms to 2000 ms) was combined with magnetizatio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00396-4

    authors: Helms G,Piringer A

    更新日期:2001-07-01 00:00:00

  • MAgnitude and PHase Thresholding (MAPHT) of noisy complex-valued magnetic resonance images.

    abstract::It is often desirable to separate voxels that contain signal from tissue along with measurement noise from those that contain purely measurement noise. Generally, this separation called thresholding utilizes only the magnitude portion of the images. Recently, methods have been developed that utilize both the magnitude...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.008

    authors: Rowe DB,Haacke EM

    更新日期:2009-11-01 00:00:00

  • Effect of slice orientation on reproducibility of fMRI motor activation at 3 Tesla.

    abstract::The effect of slice orientation on reproducibility and sensitivity of 3T fMRI activation using a motor task has been investigated in six normal volunteers. Four slice orientations were used; axial, oblique axial, coronal and sagittal. We applied analysis of variance (ANOVA) to suprathreshold voxel statistics to quanti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00399-x

    authors: Gustard S,Fadili J,Williams EJ,Hall LD,Carpenter TA,Brett M,Bullmore ET

    更新日期:2001-12-01 00:00:00

  • Area of paradoxical signal drop after the administration of superparamagnetic iron oxide on the T2-weighted image of a patient with lymphangitic metastasis of the liver.

    abstract::We report a geographic area of prominent hypointensity in T2-weighted images vs. normal adjacent liver parenchyma in a patient with cholangiocarcinoma and lymphangitic metastasis of the liver after superparamagnetic iron oxide (SPIO) administration. The area showing this prominent signal drop showed Kupffer cell proli...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.10.012

    authors: Lee Y,Lee JS,Kim CM,Jeong JY,Choi JI,Kim MJ

    更新日期:2008-05-01 00:00:00