Dependence of temporal diffusion spectra on microstructural properties of biological tissues.

Abstract:

:The apparent diffusion coefficient (ADC) measured using magnetic resonance imaging methods provides information on microstructural properties of biological tissues, and thus has found applications as a useful biomarker for assessing changes such as those that occur in ischemic stroke and cancer. Conventional pulsed gradient spin echo methods are in widespread use and provide information on, for example, variations in cell density. The oscillating gradient spin echo (OGSE) method has the additional ability to probe diffusion behaviors more readily at short diffusion times, and the temporal diffusion spectrum obtained by the OGSE method provides a unique tool for characterizing tissues over different length scales, including structural features of intracellular spaces. It has previously been reported that several tissue properties can affect ADC measurements significantly, and the precise biophysical mechanisms that account for ADC changes in different situations are still unclear. Those factors may vary in importance depending on the time and length scale over which measurements are made. In the present work, a comprehensive numerical simulation is used to investigate the dependence of the temporal diffusion spectra measured by OGSE methods on different microstructural properties of biological tissues, including cell size, cell membrane permeability, intracellular volume fraction, intranucleus and intracytoplasm diffusion coefficients, nuclear size and T(2) relaxation times. Some unique characteristics of the OGSE method at relatively high frequencies are revealed. The results presented in the paper offer a framework for better understanding possible causes of diffusion changes and may be useful to assist the interpretation of diffusion data from OGSE measurements.

journal_name

Magn Reson Imaging

authors

Xu J,Does MD,Gore JC

doi

10.1016/j.mri.2010.10.002

subject

Has Abstract

pub_date

2011-04-01 00:00:00

pages

380-90

issue

3

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(10)00320-6

journal_volume

29

pub_type

杂志文章
  • A flexible 9-channel coil array for fast 3D MR thermometry in MR-guided high-intensity focused ultrasound (HIFU) studies on rabbits at 3 T.

    abstract::Signal-to-noise ratio (SNR) is a critical factor in MR-guided high-intensity focused ultrasound (HIFU) for local heating, which can affect the accuracy of temperature measurement. In order to achieve high SNR and higher temporal resolution, dedicated coil arrays for MR-guided HIFU applications need to be developed. In...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.10.008

    authors: Chen Q,Li Y,Jiang R,Zou C,Tie C,Wen J,Yang X,Zhang X,Liu X,Zheng H

    更新日期:2020-01-01 00:00:00

  • 3D cerebrovascular segmentation combining fuzzy vessel enhancement and level-sets with anisotropic energy weights.

    abstract::The aim of this work is to present and evaluate a level-set segmentation approach with vesselness-dependent anisotropic energy weights, which focuses on the exact segmentation of malformed as well as small vessels from time-of-flight (TOF) magnetic resonance angiography (MRA) datasets. In a first step, a vesselness fi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.07.008

    authors: Forkert ND,Schmidt-Richberg A,Fiehler J,Illies T,Möller D,Säring D,Handels H,Ehrhardt J

    更新日期:2013-02-01 00:00:00

  • High-field magnetic resonance imaging using solenoid radiofrequency coils.

    abstract::High-resolution magnetic resonance imaging using dedicated high-field radiofrequency micro-coils at 16.4 T (700 MHz) was investigated. Specific solenoid coils primarily using silver and copper as conductors with enamel and polyurethane coatings were built to establish which coil configuration produces the best image. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.04.027

    authors: Vegh V,Gläser P,Maillet D,Cowin GJ,Reutens DC

    更新日期:2012-10-01 00:00:00

  • Theoretical considerations in measurement of time discrepancies between input and myocardial time-signal intensity curves in estimates of regional myocardial perfusion with first-pass contrast-enhanced MRI.

    abstract::The purpose of this study was to develop a method to determine time discrepancies between input and myocardial time-signal intensity (TSI) curves for accurate estimation of myocardial perfusion with first-pass contrast-enhanced MRI. Estimation of myocardial perfusion with contrast-enhanced MRI using kinetic models req...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.06.015

    authors: Natsume T,Ishida M,Kitagawa K,Nagata M,Sakuma H,Ichihara T

    更新日期:2015-11-01 00:00:00

  • A novel in silico platform for a fully automatic personalized brain tumor growth.

    abstract::Glioblastoma Multiforme is the most common and most aggressive type of brain tumors. Although accurate prediction of Glioblastoma borders and shape is absolutely essential for neurosurgeons, there are not many in silico platforms that can make such predictions. In the current study, an automatic patient-specific simul...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.12.012

    authors: Hajishamsaei M,Pishevar A,Bavi O,Soltani M

    更新日期:2020-05-01 00:00:00

  • Influence of attention focus on neural activity in the human spinal cord during thermal sensory stimulation.

    abstract::Perceptions of sensation and pain in healthy people are believed to be the net result of sensory input and descending modulation from brainstem and cortical regions depending on emotional and cognitive factors. Here, the influence of attention on neural activity in the spinal cord during thermal sensory stimulation of...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.07.012

    authors: Stroman PW,Coe BC,Munoz DP

    更新日期:2011-01-01 00:00:00

  • Impact of baseline CO2 on Blood-Oxygenation-Level-Dependent MRI measurements of cerebrovascular reactivity and task-evoked signal activation.

    abstract::Neurovascular coupling describes the cascade between neuronal activity and subsequent Blood-Oxygenation-Level-Dependent (BOLD) signal increase. Based on this premise, the correlation of this BOLD signal increase with a particular task, such as finger-tapping, is used to map neuronal activation. This signal increase ma...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.02.002

    authors: van Niftrik CHB,Piccirelli M,Bozinov O,Maldaner N,Strittmatter C,Pangalu A,Valavanis A,Regli L,Fierstra J

    更新日期:2018-06-01 00:00:00

  • Pretibial cyst formation after anterior cruciate ligament reconstruction using auto hamstring grafts: two case reports in a prospective study of 89 cases.

    abstract::Eighty-nine cases after anterior cruciate ligaments (ACL) reconstruction were followed prospectively with magnetic resonance imaging (MRI). The patients were examined using axial and sagittal MRI at least twice during the postoperative evaluation of reconstructed ACL. Two cases of pretibial cyst formation were observe...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00207-1

    authors: Deie M,Sumen Y,Ochi M,Murakami Y,Fujimoto E,Ikuta Y

    更新日期:2000-10-01 00:00:00

  • Topographical and zonal patterns of T2 relaxation in osteoarthritic tibial cartilage by low- and high-resolution MRI.

    abstract:PURPOSE:This study aimed to establish the topographical and zonal T2 patterns of multi-resolution MRI in medial tibial cartilage in a canine model of osteoarthritis (OA), initiated by the anterior cruciate ligament (ACL) transection surgery, and studied after 8-weeks and 12-weeks post-surgery. METHODS:Articular cartil...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2021.01.002

    authors: Badar F,Lee J,Qu X,Xia Y

    更新日期:2021-01-22 00:00:00

  • Magnetic resonance imaging of female pelvic masses and local recurrent tumors at an ultra low (0.02 T) magnetic field: correlation with computed tomography.

    abstract::Pelvic MR (41 patients) and CT (36 patients) examinations were performed on 14 females with a primary pelvic complaint, and on 28 females with a suspicion of local recurrent disease of gynecologic malignant tumor. Benign cystic tumors were found in eight patients, five patients had endometriomas, one had a lymphoma, a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90409-7

    authors: Varpula M

    更新日期:1993-01-01 00:00:00

  • Phase contrast and time-of-flight magnetic resonance angiography of the intracerebral arteries at 1.5, 3 and 7 T.

    abstract:PURPOSE:Time-of-flight (ToF) and phase contrast (PC) magnetic resonance angiographies (MRAs) are noninvasive applications to depict the cerebral arteries. Both approaches can image the cerebral vasculature without the administration of intravenous contrast. Therefore, it is used in routine clinical evaluation of cerebr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.10.023

    authors: Stamm AC,Wright CL,Knopp MV,Schmalbrock P,Heverhagen JT

    更新日期:2013-05-01 00:00:00

  • Severe anaphylactoid reaction after i.v. Gd-DTPA.

    abstract::Serious adverse reactions following the IV administration of Gd-DTPA (Magnevist, gadopenetate dimeglumine, Berlex Laboratories, Wayne, NJ), although extremely rare, can occur. As yet, there has been no published case of a severe anaphylactoid-type reaction to Gd-DTPA. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90019-x

    authors: Weiss KL

    更新日期:1990-01-01 00:00:00

  • Quantitation of non-Einstein diffusion behavior of water in biological tissues by proton MR diffusion imaging: synthetic image calculations.

    abstract::The non-Einstein diffusion behavior of water in a model biological tissue system, intact duck embryos, has been investigated by the use of an in vivo proton pulsed-gradient spin-echo (PGSE) MR imaging technique. Multiple-frame MR images of the intact duck embryos and control solution (0.5 mM CuSO4 doped water) were ac...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90476-t

    authors: Cheng KH

    更新日期:1993-01-01 00:00:00

  • Undifferentiated (embryonal) sarcoma of the liver (USL): MRI findings including dynamic gadolinium enhancement.

    abstract::We report the MR appearance of undifferentiated (embryonal) sarcoma of the liver (USL) in a 13-year-old female who presented with a 1-year history of intermittent abdominal pain, weight loss, and fatigue. The tumor was a large, solitary, well-defined focal mass lesion with multiple cystic spaces, septations, and subst...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.02.003

    authors: Psatha EA,Semelka RC,Fordham L,Firat Z,Woosley JT

    更新日期:2004-07-01 00:00:00

  • The lever-coil: a simple, inexpensive sensor for respiratory and cardiac motion in MRI experiments.

    abstract::Thoracic and abdominal magnetic resonance imaging studies generally require some type of compensation for respiratory and cardiac motions in order to yield artifact-free images with good signal-to-noise ratio. Most techniques for respiratory compensation require the use of a non-NMR sensing device to monitor the subje...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00403-9

    authors: Fishbein KW,McConville P,Spencer RG

    更新日期:2001-07-01 00:00:00

  • Non-invasive temperature mapping using MRI: comparison of two methods based on chemical shift and T1-relaxation.

    abstract:PURPOSE:To implement and evaluate the accuracy of non-invasive temperature mapping using MRI methods based on the chemical shift (CS) and T1 relaxation in media of various heterogeneity during focal (laser) and external thermal energy deposition. MATERIALS AND METHODS:All measurements were performed on a 1.5 T superco...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00311-1

    authors: Bertsch F,Mattner J,Stehling MK,Müller-Lisse U,Peller M,Loeffler R,Weber J,Messmer K,Wilmanns W,Issels R,Reiser M

    更新日期:1998-05-01 00:00:00

  • Prolonged T1 in patients with liver cirrhosis: an in vivo MRI study.

    abstract::Fifteen patients with liver cirrhosis and two control groups were examined. The first control group consisted of 7 healthy volunteers, and the second group of 17 patients with nonfocal liver diseases. The T1 and T2 relaxation times were calculated from signal intensities read out from a region of interest centrally lo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(90)90137-q

    authors: Thomsen C,Christoffersen P,Henriksen O,Juhl E

    更新日期:1990-01-01 00:00:00

  • In vitro experiments on ICOSA6 4D flow MRI measurement for the quantification of velocity and turbulence parameters.

    abstract:PURPOSE:To perform comprehensive in vitro experiments using six-directional icosahedral flow encoding (ICOSA6) 4D flow magnetic resonance imaging (MRI) under various scan conditions to analyze the robustness of velocity and turbulence quantification. MATERIALS AND METHODS:In vitro flow phantoms with steady flow rates ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.06.020

    authors: Ha H,Park KJ,Dyverfeldt P,Ebbers T,Yang DH

    更新日期:2020-10-01 00:00:00

  • Short TI short TR inversion recovery imaging using reduced flip angles.

    abstract::In this paper the effects of reducing the flip angle of the 90-degree observation pulse in inversion recovery imaging are described and analyzed. When incorporated in an IR sequence with a short inversion time (STIR), reduction to the 90-degree pulse allows a significant shortening of the repetition time without loss ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90418-l

    authors: Bakker CJ,Witkamp TD,Janssen WM

    更新日期:1991-01-01 00:00:00

  • Accuracy and precision of quantitative DCE-MRI parameters: How should one estimate contrast concentration?

    abstract:INTRODUCTION:Pharmacokinetic parameters derived from dynamic contrast-enhanced MRI (DCE-MRI) data are sensitive to acquisition and post-processing techniques, which makes it difficult to compare results obtained using different methods. In particular, one of the most important factors affecting estimation of model para...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.05.007

    authors: Wake N,Chandarana H,Rusinek H,Fujimoto K,Moy L,Sodickson DK,Kim SG

    更新日期:2018-10-01 00:00:00

  • A new NOE-mediated MT signal at around -1.6ppm for detecting ischemic stroke in rat brain.

    abstract::In the present work, we reported a new nuclear Overhauser enhancement (NOE)-mediated magnetization transfer (MT) signal at around -1.6ppm (NOE(-1.6)) in rat brain and investigated its application in the detection of acute ischemic stroke in rodent model. Using continuous wave (CW) MT sequence, the NOE(-1.6) is reliabl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.05.002

    authors: Zhang XY,Wang F,Afzal A,Xu J,Gore JC,Gochberg DF,Zu Z

    更新日期:2016-10-01 00:00:00

  • A new RF transmit coil for foot and ankle imaging at 7T MRI.

    abstract::A four-channel Tic-Tac-Toe (TTT) transmit RF coil was designed and constructed for foot and ankle imaging at 7T MRI. Numerical simulations using an in-house developed FDTD package and experimental analyses using a homogenous phantom show an excellent agreement in terms of B1+ field distribution and s-parameters. Simul...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.09.005

    authors: Santini T,Kim J,Wood S,Krishnamurthy N,Farhat N,Maciel C,Raval SB,Zhao T,Ibrahim TS

    更新日期:2018-01-01 00:00:00

  • Can preoperative diffusion-weighted MRI predict postoperative hepatic insufficiency after curative resection of HBV-related hepatocellular carcinoma? A pilot study.

    abstract::Liver fibrosis determines the functional liver reserve. Several studies have reported that the apparent diffusion coefficient (ADC) values of diffusion-weighted magnetic resonance imaging (DW-MRI) can assess liver fibrosis. We investigated whether DW-MRI predicts postoperative hepatic insufficiency and liver fibrosis ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.03.018

    authors: Kim SU,Kim YC,Choi JS,Kim KS,Choi GH,Choi JS,Park JY,Kim DY,Ahn SH,Choi EH,Park YN,Chon CY,Han KH,Kim MJ

    更新日期:2010-07-01 00:00:00

  • Controlled delivery of Gd-containing liposomes to lymph nodes: surface modification may enhance MRI contrast properties.

    abstract::Surface modification of liposomes containing Gd-diethylenetriaminepentaacetyl-phosphatidylethanolamine (Gd-DTPA-PE) as an amphiphilic paramagnetic label influences their contrast properties as MRI agents. Liposomes with the mean diameter ca. 220 nm and 10% mol content of Gd-DTPA-PE were modified with dextran (molecula...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)00083-f

    authors: Trubetskoy VS,Cannillo JA,Milshtein A,Wolf GL,Torchilin VP

    更新日期:1995-01-01 00:00:00

  • Glutamate quantification by PRESS or MEGA-PRESS: Validation, repeatability, and concordance.

    abstract:PURPOSE:While PRESS is often employed to measure glutamate concentrations, MEGA-PRESS enables simultaneous Glx (glutamate and glutamine) and GABA measurements. This study aimed to compare validation, repeatability, and concordance of different approaches for glutamate quantification at 3T to aid future studies in their...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.12.029

    authors: van Veenendaal TM,Backes WH,van Bussel FCG,Edden RAE,Puts NAJ,Aldenkamp AP,Jansen JFA

    更新日期:2018-05-01 00:00:00

  • Fast T2-mapping with snapshot flash imaging.

    abstract::It has been shown recently that quantitative T2-maps may be measured by acquisition of a series of at least eight T2-weighted SNAPSHOT FLASH images. These measurements require a relaxation delay of 10-15 s after each T2-weighted image for the complete relaxation of the spin system. This results in long measuring times...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00004-z

    authors: Deichmann R,Adolf H,Nöth U,Morrissey S,Schwarzbauer C,Haase A

    更新日期:1995-01-01 00:00:00

  • Water diffusion in biological porous systems: a NMR approach.

    abstract::The spin-echo nuclear magnetic resonance (NMR) technique together with paramagnetic ion doping are used to study structural parameters of plant samples, such as restricted dimensions, and cell interconnection both through membranes and by cell contact by studying simultaneous restricted diffusion and intercellular wat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00053-8

    authors: Anisimov AV,Sorokina NY,Dautova NR

    更新日期:1998-06-01 00:00:00

  • Increased confidence of diagnosis of Ewing sarcoma using T2-weighted MR images.

    abstract::To assess whether magnetic resonance imaging could assist in diagnosing Ewing sarcoma, we retrospectively analyzed T1- and T2-weighted images of 24 consecutive solitary lytic bone lesions, including 18 cases of histologically proven Ewing sarcoma, and six aggressive-appearing benign lesions including eosinophilic gran...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92450-3

    authors: Hanna SL,Fletcher BD,Kaste SC,Fairclough DL,Parham DM

    更新日期:1994-01-01 00:00:00

  • Initial changes of non-traumatic osteonecrosis of femoral head in fat suppression images: bone marrow edema was not found before the appearance of band patterns.

    abstract::The present study examined initial changes in non-traumatic osteonecrosis of the femoral head (ONF) on T1- and T2-weighted MR images, and fat suppression images. The subjects were 57 renal transplant recipients (37 males and 20 females), whose median age at the time of transplantation was 31.5 years old (range, 10 to ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00424-6

    authors: Fujioka M,Kubo T,Nakamura F,Shibatani M,Ueshima K,Hamaguchi H,Inoue S,Sugano N,Sakai T,Torii Y,Hasegawa Y,Hirasawa Y

    更新日期:2001-09-01 00:00:00

  • MRI findings in pulmonary sarcoidosis.

    abstract::Postero-anterior radiographs and magnetic resonance imaging (MRI) of the chest were performed in nine biopsy proven cases of sarcoidosis. MRI was more sensitive than a postero-anterior chest roentgenogram in detecting hilar and mediastinal adenopathy but less informative in detecting pleural and parenchymal disease. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90131-2

    authors: Craig DA,Colletti PM,Ratto D,Gordonson JS,Raval JK,Sharma OP

    更新日期:1988-09-01 00:00:00