Complimentary aspects of diffusion imaging and fMRI: II. Elucidating contributions to the fMRI signal with diffusion sensitization.

Abstract:

:Tissue water molecules reside in different biophysical compartments. For example, water molecules in the vasculature reside for variable periods of time within arteries, arterioles, capillaries, venuoles and veins, and may be within blood cells or blood plasma. Water molecules outside of the vasculature, in the extravascular space, reside, for a time, either within cells or within the interstitial space between cells. Within these different compartments, different types of microscopic motion that water molecules may experience have been identified and discussed. These range from Brownian diffusion to more coherent flow over the time scales relevant to functional magnetic resonance imaging (fMRI) experiments, on the order of several 10s of milliseconds. How these different types of motion are reflected in magnetic resonance imaging (MRI) methods developed for "diffusion" imaging studies has been an ongoing and active area of research. Here we briefly review the ideas that have developed regarding these motions within the context of modern "diffusion" imaging techniques and, in particular, how they have been accessed in attempts to further our understanding of the various contributions to the fMRI signal changes sought in studies of human brain activation.

journal_name

Magn Reson Imaging

authors

Mulkern RV,Haker SJ,Maier SE

doi

10.1016/j.mri.2007.02.006

subject

Has Abstract

pub_date

2007-07-01 00:00:00

pages

939-52

issue

6

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(07)00197-X

journal_volume

25

pub_type

杂志文章,评审
  • Electrophoretic NMR studies of electrical transport in fluid-filled porous systems.

    abstract::An NMR technique is described which allows the observation of ionic charge carriers moving in the electric field within a porous system saturated with electrolyte solution. This method, which was recently developed in our laboratory, gives experimental access to the study of electric transport in disordered media on a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00267-3

    authors: Holz M,Heil SR,Schwab IA

    更新日期:2001-04-01 00:00:00

  • A data augmentation approach to train fully convolutional networks for left ventricle segmentation.

    abstract::Left ventricle (LV) segmentation plays an important role in the diagnosis of cardiovascular diseases. The cardiac contractile function can be quantified by measuring the segmentation results of LVs. Fully convolutional networks (FCNs) have been proven to be able to segment images. However, a large number of annotated ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.08.004

    authors: Lin A,Wu J,Yang X

    更新日期:2020-02-01 00:00:00

  • Study of normal breast tissue by in vivo volume localized proton MR spectroscopy: variation of water-fat ratio in relation to the heterogeneity of the breast and the menstrual cycle.

    abstract:PURPOSE:To investigate the alterations in water-fat (W-F) ratio of the normal breast tissue of female volunteers as a function of the histological phases of the menstrual cycle. METHODS:Image-guided volume localized in vivo proton ((1)H) magnetic resonance spectroscopy (MRS) at 1.5 T was carried out in the para-areola...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.01.004

    authors: Sharma U,Kumar M,Sah RG,Jagannathan NR

    更新日期:2009-07-01 00:00:00

  • Spectral pattern of total creatine and trimethyl ammonium in multiple sclerosis.

    abstract::Fatigue and impairment mobility are frequent problems in multiple sclerosis (MS). Despite its enormous potential, in vivo (1)H MRS of skeletal muscles for MS patients is a largely unexplored field. One fundamental question remains unanswered: whether MS can cause observable proton metabolite changes. High quality two-...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.005

    authors: Hu J,Xu Y,Jiang Q,Sehgal V,Shen Y,Xuan Y,Xia Y

    更新日期:2004-04-01 00:00:00

  • A simple noise correction scheme for diffusional kurtosis imaging.

    abstract:PURPOSE:Diffusional kurtosis imaging (DKI) is sensitive to the effects of signal noise due to strong diffusion weightings and higher order modeling of the diffusion weighted signal. A simple noise correction scheme is proposed to remove the majority of the noise bias in the estimated diffusional kurtosis. METHODS:Weig...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.028

    authors: Glenn GR,Tabesh A,Jensen JH

    更新日期:2015-01-01 00:00:00

  • Study on the variations of the apparent diffusion coefficient in areas of solid tumor in high grade gliomas.

    abstract::Present knowledge suggests that in glioblastoma multiforme the value of the apparent diffusion coefficient (ADC) is elevated in the solid part and hyperintense in T1, in spite of the elevated cellularity, and also in areas where peritumoral vasogenic edema is present. The purpose of our study has been to verify in viv...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00594-5

    authors: Muti M,Aprile I,Principi M,Italiani M,Guiducci A,Giulianelli G,Ottaviano P

    更新日期:2002-11-01 00:00:00

  • NMR imaging, NMR diffraction and applications of pulsed gradient spin echoes in porous media.

    abstract::Diffraction ideas were first introduced to NMR by Mansfield and Grannell. Here we compare "Mansfield (k-space) diffraction" with the "diffusive (q-space) diffraction," noting their similarities and differences. The diffusive-diffraction concept is extremely helpful in elucidating the Pulsed Gradient Spin Echo NMR expe...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00152-x

    authors: Callaghan PT

    更新日期:1996-01-01 00:00:00

  • Determination of blood circulation times of superparamagnetic iron oxide nanoparticles by T2* relaxometry using ultrashort echo time (UTE) MRI.

    abstract::Blood circulation is an important determinant of the biodistribution of superparamagnetic iron oxide nanoparticles. Here we present a magnetic resonance imaging (MRI) technique based on the use of ultrafast echo times (UTE) for the noninvasive determination of blood half-lives at high particle concentrations, when con...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.06.017

    authors: Scharlach C,Warmuth C,Schellenberger E

    更新日期:2015-11-01 00:00:00

  • Fat ViP MRI: Virtual Phantom Magnetic Resonance Imaging of water-fat systems.

    abstract:OBJECT:Virtual Phantom Magnetic Resonance Imaging (ViP MRI) is a method to generate reference signals on MR images, using external radiofrequency (RF) signals. The aim of this study was to assess the feasibility of ViP MRI to generate complex-data images of phantoms mimicking water-fat systems. MATERIALS AND METHODS:V...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.002

    authors: Salvati R,Hitti E,Bellanger JJ,Saint-Jalmes H,Gambarota G

    更新日期:2016-06-01 00:00:00

  • Dose distribution of proton beams with NMR measurements of Fricke-agarose gels.

    abstract::Fricke-agarose gels have been irradiated with a proton beam. Then samples have been extracted at different depths with respect to the beam penetration distance, corresponding to different irradiation doses. Relaxation times T1 and T2, measured at 17 MHz, appear sensitive to this kind of radiation. In particular, T2 ex...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00380-3

    authors: Di Capua S,D'Errico F,Egger E,Guidoni L,Luciani AM,Rosi A,Viti V

    更新日期:1997-01-01 00:00:00

  • NMR-based analysis of shear strength of weakly expansive clay in sodium chloride solution.

    abstract::A series of direct shear and nuclear magnetic resonance (NMR) tests were performed on a compacted weakly expansive clay saturated by sodium chloride (NaCl) solutions with different concentrations to study the effect of NaCl solution on the shear strength and its mechanism. Results from the direct shear tests show that...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.01.002

    authors: Yu H,Sun D,Tian H

    更新日期:2019-05-01 00:00:00

  • In vitro experiments on ICOSA6 4D flow MRI measurement for the quantification of velocity and turbulence parameters.

    abstract:PURPOSE:To perform comprehensive in vitro experiments using six-directional icosahedral flow encoding (ICOSA6) 4D flow magnetic resonance imaging (MRI) under various scan conditions to analyze the robustness of velocity and turbulence quantification. MATERIALS AND METHODS:In vitro flow phantoms with steady flow rates ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.06.020

    authors: Ha H,Park KJ,Dyverfeldt P,Ebbers T,Yang DH

    更新日期:2020-10-01 00:00:00

  • Astrocytic energy metabolism and glutamate formation--relevance for 13C-NMR spectroscopy and importance of cytosolic/mitochondrial trafficking.

    abstract::Glutamate plays a double role in (13)C-nuclear magnetic resonance (NMR) spectroscopic determination of glucose metabolism in the brain. Bidirectional exchange between initially unlabeled glutamate and labeled α-ketoglutarate, formed from pyruvate via pyruvate dehydrogenase (PDH), indicates the rate of energy metabolis...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.04.013

    authors: Hertz L

    更新日期:2011-12-01 00:00:00

  • PERFIDI: parametrically enabled relaxation filters with double and multiple inversion.

    abstract::We present a novel approach to the nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) analysis of complex samples with nontrivial distribution of longitudinal relaxation rate R(1). Parametrically enabled relaxation filters with double and multiple inversion (PERFIDI) aim to separate signals arising ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.12.001

    authors: Sykora S,Bortollotti V,Fantazzini P

    更新日期:2007-05-01 00:00:00

  • Diffusion and spatially resolved NMR in Berea and Venezuelan oil reservoir rocks.

    abstract::Conventional and spatially resolved proton NMR and relaxation measurements are used in order to study the molecular motions and the equilibrium and nonequilibrium diffusion of oils in Berea sandstone and Venezuelan reservoir rocks. In the water-saturated Berea a single line with T*2 congruent to 150 microseconds is ob...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90420-5

    authors: Murgich J,Corti M,Pavesi L,Voltini F

    更新日期:1992-01-01 00:00:00

  • Accurate and sensitive measurements of magnetic susceptibility using echo planar imaging.

    abstract::Susceptibility differences are common causes for artifacts in magnetic resonance (MR); therefore, it is important to choose phantom materials in a way that these artifacts are kept at a minimum. In this study, a previously proposed MR imaging (MRI) method [Beuf O, Briguet A, Lissac M, Davis R. Magnetic resonance imagi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.07.005

    authors: Carlsson A,Starck G,Ljungberg M,Ekholm S,Forssell-Aronsson E

    更新日期:2006-11-01 00:00:00

  • Internal derangement of the temporomandibular joint: radiologic staging with clinical, surgical, and pathologic correlation.

    abstract::The radiologic findings from 60 patients with 86 internally deranged temporomandibular joints (TMJ) upon whom sequential imaging procedures had been performed over a period of two months to ten years were analyzed and correlated with clinical, surgical (72 joints), and pathological observations. Internal derangement o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90404-9

    authors: Schellhas KP

    更新日期:1989-09-01 00:00:00

  • Three-dimensional magnetic resonance spectroscopic imaging of histologically confirmed brain tumors.

    abstract::The goal of this study was to determine whether presurgical metabolite levels measured by 3D MR Spectroscopic Imaging (MRSI) can accurately detect viable cancer within human brain tumor masses. A total of 31 patients (33 exams, 39 pathology correlations) with brain tumors were studied prior to surgical biopsy and/or r...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0730-725x(01)00225-9

    authors: Vigneron D,Bollen A,McDermott M,Wald L,Day M,Moyher-Noworolski S,Henry R,Chang S,Berger M,Dillon W,Nelson S

    更新日期:2001-01-01 00:00:00

  • Noninvasive evaluation of the regional variations of GABA using magnetic resonance spectroscopy at 3 Tesla.

    abstract:PURPOSE:Rapid regional fluctuations in GABA may result in inhomogeneous concentrations throughout the brain parenchyma. The goal of this study is to provide further insight into the natural distribution of GABA throughout the brain and thus determine if a surrogate site may be used for spectroscopy when evaluating moto...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.02.015

    authors: Durst CR,Michael N,Tustison NJ,Patrie JT,Raghavan P,Wintermark M,Sendhil Velan S

    更新日期:2015-06-01 00:00:00

  • Short T2 contrast with three-dimensional ultrashort echo time imaging.

    abstract::There is increasing interest in imaging short T2 species which show little or no signal with conventional magnetic resonance (MR) pulse sequences. In this paper, we describe the use of three-dimensional ultrashort echo time (3D UTE) sequences with TEs down to 8 μs for imaging of these species. Image contrast was gener...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.11.003

    authors: Du J,Bydder M,Takahashi AM,Carl M,Chung CB,Bydder GM

    更新日期:2011-05-01 00:00:00

  • A method for imaging of chemical shift or magnetic field distributions.

    abstract::A phase encoding method for imaging of chemical shift or magnetic field distributions is described. The method utilizes the spin-echo principle and the time period between signal collection and excitation is constant but the time period between excitation and the 180 degrees pulse is varied by constant steps. The meth...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90253-x

    authors: Sepponen RE

    更新日期:1985-01-01 00:00:00

  • The reliability of routine clinical post-processing software in assessing potential diffusion-weighted MRI "biomarkers" in brain metastases.

    abstract:BACKGROUND AND PURPOSE:Diffusion MRI characteristics have been used as biomarkers to guide prognosis in cerebral pathologies including brain metastases. The measurement of ADC is often described poorly in clinical and research studies with little detail given to the practical considerations of where to place ROIs, whic...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.12.010

    authors: Zakaria R,Das K,Bhojak M,Radon M,Sluming V,Walker C,Jenkinson MD

    更新日期:2014-04-01 00:00:00

  • Paradoxical parasellar high signals resembling shunt diseases on routine 3D time-of-flight MR angiography of the brain: mechanism for the signals and differential diagnosis from shunt diseases.

    abstract:BACKGROUND AND PURPOSE:We occasionally encounter phenomena in which venous flow signals of the cavernous sinus (CS) and/or inferior petrosal sinus (IPS) are visualized paradoxically in patients without arteriovenous shunt in 3D time-of-flight magnetic resonance angiography (3D-TOF MRA) of the brain. The aims of this st...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.08.004

    authors: Sakamoto M,Taoka T,Iwasaki S,Nakagawa H,Fukusumi A,Takayama K,Wada T,Kichikawa K

    更新日期:2004-11-01 00:00:00

  • MRI of the normal hippocampus.

    abstract::Before it is possible to use MR imaging to investigate changes in the hippocampus in disease processes such as epilepsy and memory disorders, it is imperative that normal variations are defined. Using specific anatomic locations, we evaluated the hippocampi of 29 normal volunteers with coronal MR studies. Mild variati...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90035-k

    authors: Bronen RA,Cheung G

    更新日期:1991-01-01 00:00:00

  • High-resolution in vivo diffusion tensor imaging of the injured cat spinal cord using self-navigated, interleaved, variable-density spiral acquisition (SNAILS-DTI).

    abstract::Diffusion tensor magnetic resonance imaging (DTI) is useful for studying the microstructural changes in the spinal cord following traumatic injury; however, image quality is generally poor due to the small size of the spinal cord, physiological motion and susceptibility artifacts. Self-navigated, interleaved, variable...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.06.006

    authors: Ellingson BM,Sulaiman O,Kurpad SN

    更新日期:2010-11-01 00:00:00

  • SSFP fMRI at 3 tesla: Efficiency of polar acquisition-reconstruction technique.

    abstract::SSFP-based fMRI techniques, known for their high specificity and low geometrical distortion, look promising for high-resolution brain mapping. Nevertheless, they suffer from lack of speed and sensitivity, leading them to be exploited mostly in high-field scanners. Radial acquisition can help with these inefficiencies ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.09.005

    authors: Malekian V,Rastegar F,Shafieizargar B,Nasiraei-Moghaddam A

    更新日期:2020-12-01 00:00:00

  • Intramuscular adipose tissue determined by T1-weighted MRI at 3T primarily reflects extramyocellular lipids.

    abstract:PURPOSE:The purpose of this study was to assess relationships between intramuscular adipose tissue (IntraMAT) content determined by MRI and intramyocellular lipids (IMCL) and extramyocellular lipids (EMCL) determined by (1)H magnetic resonance spectroscopy ((1)H MRS) or echo intensity determined by B-mode ultrasonograp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.038

    authors: Akima H,Hioki M,Yoshiko A,Koike T,Sakakibara H,Takahashi H,Oshida Y

    更新日期:2016-05-01 00:00:00

  • A NMR characterisation of a banded sandstone.

    abstract::1H-nuclear magnetic resonance (NMR) measurements have been carried out on a banded sandstone to investigate the effects of structural inhomogeneities on the fluid dynamics of the sample as a whole. The results obtained from average propagator measurements (the probability of a displacement z in a time delta or P delta...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00043-5

    authors: Bolam AC,Packer KJ

    更新日期:1998-06-01 00:00:00

  • The Langerhans' cell histiocytosis (eosinophilic granuloma) of the cervical spine: a rare diagnosis of cervical pain.

    abstract::We present the case of a 44-year-old man who complained of cervical pain. He was treated with physiotherapy and analgetics. Because of persistent pain, computed tomography (CT) scan and MRI were performed. They revealed an osteolytic destruction of the fourth cervical vertebra. The patient was treated surgically for r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.01.006

    authors: Simanski C,Bouillon B,Brockmann M,Tiling T

    更新日期:2004-05-01 00:00:00

  • Phase detection and contrast loss in magnetic resonance imaging.

    abstract::Several recent articles have assessed the relative efficiency of nuclear magnetic resonance (NMR) pulse sequences. One consideration that has received little attention is the effect on image contrast of displaying images without information on the sign of the reconstructed signals. The radiofrequency receivers current...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(84)90193-0

    authors: Hendrick RE,Nelson TR,Hendee WR

    更新日期:1984-01-01 00:00:00