Three-dimensional adiabatic inversion recovery prepared ultrashort echo time cones (3D IR-UTE-Cones) imaging of cortical bone in the hip.

Abstract:

PURPOSE:We present three-dimensional adiabatic inversion recovery prepared ultrashort echo time Cones (3D IR-UTE-Cones) imaging of cortical bone in the hip of healthy volunteers using a clinical 3T scanner. METHODS:A 3D IR-UTE-Cones sequence, based on a short pulse excitation followed by a 3D Cones trajectory, with a nominal TE of 32μs, was employed for high contrast morphological imaging of cortical bone in the hip of heathy volunteers. Signals from soft tissues such as muscle and marrow fat were suppressed via adiabatic inversion and signal nulling. T2⁎ value of the cortical bone was also calculated based on 3D IR-UTE-Cones acquisitions with a series of TEs ranging from 0.032 to 0.8ms. A total of four healthy volunteers were recruited for this study. Average T2⁎ values and the standard deviation for four regions of interests (ROIs) at the greater trochanter, the femoral neck, the femoral head and the lesser trochanter were calculated. RESULTS:The 3D IR-UTE-Cones sequence provided efficient suppression of soft tissues with excellent image contrast for cortical bone visualization in all volunteer hips. Exponential single component decay was observed for all ROIs, with averaged T2⁎ values ranging from 0.33 to 0.45ms, largely consistent with previously reported T2⁎ values of cortical bone in the tibial midshaft. CONCLUSIONS:The 3D IR-UTE-Cones sequence allows in vivo volumetric imaging and quantitative T2⁎ measurement of cortical bone in the hip using a clinical 3T scanner.

journal_name

Magn Reson Imaging

authors

Nazaran A,Carl M,Ma Y,Jerban S,Zhu Y,Lu X,Du J,Chang EY

doi

10.1016/j.mri.2017.07.012

subject

Has Abstract

pub_date

2017-12-01 00:00:00

pages

60-64

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(17)30128-5

journal_volume

44

pub_type

杂志文章
  • "Molecular" MR imaging at high fields.

    abstract::Magnetic resonance imaging (MRI) and spectroscopy (MRS) have contributed considerably to clinical radiology, and a variety of MR techniques have been developed to evaluate pathological processes as well as normal tissue biology at the cellular and molecular level. However, in comparison to nuclear imaging, MRI has rel...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.12.008

    authors: Gore JC,Zu Z,Wang P,Li H,Xu J,Dortch R,Gochberg DF

    更新日期:2017-05-01 00:00:00

  • Usefulness of cervical magnetic resonance imaging for detecting type A acute aortic dissection with acute stroke symptoms.

    abstract::Type A acute aortic dissection (TAAAD) sometimes presents with acute stroke-like symptoms. When intravenous tissue plasminogen activator (IV-tPA) therapy is considered for acute ischemic stroke, TAAAD must be excluded. Painless TAAAD presenting with acute stroke may be easily missed. Two cases of painless TAAAD presen...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.04.021

    authors: Matsumoto H,Yoshida Y,Hirata Y

    更新日期:2016-09-01 00:00:00

  • Effect of anesthesia on the signal intensity in tumors using BOLD-MRI: comparison with flow measurements by Laser Doppler flowmetry and oxygen measurements by luminescence-based probes.

    abstract::BOLD-contrast functional magnetic resonance imaging (MRI) was used to assess the evolution of tumor oxygenation and blood flow after administration of four different anesthetics: pentobarbital (60 mg/kg), ketamine/xylazine (80/8 mg/kg), fentanyl/droperidol (0.078/3.9 mg/kg), and isoflurane (1.5%). Gradient echo sequen...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.02.005

    authors: Baudelet C,Gallez B

    更新日期:2004-09-01 00:00:00

  • Computer-assisted design of surface coils used in magnetic resonance imaging. I. The calculation of the magnetic field.

    abstract::For a number of reasons, it is desirable to fabricate coils which, for a known current, shall produce predetermined values of the magnetic field intensity at a number of points within a nuclear magnetic resonance imager. The calculation of the magnetic field intensity at a set of points involves the integration of the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90524-9

    authors: Letcher JH

    更新日期:1989-11-01 00:00:00

  • Off-resonance binomial preparatory pulse technique for high sensitivity MRI of H2O17.

    abstract::H2O17 is a freely diffusible tracer and naturally occurring isotope of O16 detectable by MRI and has been shown to be useful for assessing cerebral perfusion in animal studies using direct and indirect MR detection techniques. However, earlier MR techniques are either not sensitive to changes in small concentrations o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.09.005

    authors: Sood R

    更新日期:2004-02-01 00:00:00

  • Free-running simultaneous myocardial T1/T2 mapping and cine imaging with 3D whole-heart coverage and isotropic spatial resolution.

    abstract:PURPOSE:To develop a free-running framework for 3D isotropic simultaneous myocardial T1/T2 mapping and cine imaging. METHODS:Continuous data acquisition with 3D golden angle radial trajectory is used in conjunction with T2 preparation of varying echo times and inversion recovery (IR) pulses to enable simultaneous myoc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.08.008

    authors: Qi H,Bustin A,Cruz G,Jaubert O,Chen H,Botnar RM,Prieto C

    更新日期:2019-11-01 00:00:00

  • Analysis of microporosity and setting of reactive powder concrete by proton nuclear relaxation.

    abstract::The proton spin-lattice relaxation measured at several frequencies leads to a resolved distribution of four Tli for reactive powder concrete (RPC). The typical Tli frequency dependences are quantitatively interpreted by a biphasic fast exchange model and a proton nuclear relaxation of hydrated paramagnetic ions at the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00063-0

    authors: Philippot S,Korb JP,Petit D,Zanni H

    更新日期:1998-06-01 00:00:00

  • Accuracy and precision of quantitative DCE-MRI parameters: How should one estimate contrast concentration?

    abstract:INTRODUCTION:Pharmacokinetic parameters derived from dynamic contrast-enhanced MRI (DCE-MRI) data are sensitive to acquisition and post-processing techniques, which makes it difficult to compare results obtained using different methods. In particular, one of the most important factors affecting estimation of model para...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.05.007

    authors: Wake N,Chandarana H,Rusinek H,Fujimoto K,Moy L,Sodickson DK,Kim SG

    更新日期:2018-10-01 00:00:00

  • Fractional amplitude of low-frequency fluctuation changes in monkeys with spinal cord injury: a resting-state fMRI study.

    abstract:PURPOSE:Although functional magnetic resonance imaging (fMRI) has revealed that spinal cord injury (SCI) causes anomalous changes in task-induced brain activation, its effect during the resting state remains unclear. The aim of this study is to explore the changes of the brain resting-state function in non-human primat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.02.001

    authors: Rao JS,Ma M,Zhao C,Zhang AF,Yang ZY,Liu Z,Li XG

    更新日期:2014-06-01 00:00:00

  • The application of NMR imaging to the studies of enhanced oil recovery in China.

    abstract::The advantages of the application of NMR imaging to the studies of enhanced oil recovery methods that include polymer slug flooding, combination slug flooding, and thermal soaking are described. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00192-0

    authors: Weimin W,Dongjiang L,Wei L

    更新日期:1996-01-01 00:00:00

  • Probe efficiency improvement with remote and transmission line tuning and matching.

    abstract::In certain nuclear magnetic resonance (NMR) applications in which accessibility to the gantry is limited, performing optimal tuning and matching represents a major problem. Here, we discuss a method of tuning NMR probe circuits and matching their impedances which uses cables with different impedance values. This simpl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00051-x

    authors: Villa P,Vaquero JJ,Chesnick S,Ruiz-Cabello J

    更新日期:1999-09-01 00:00:00

  • MRI appearance of disseminated osseous tuberculosis.

    abstract::Disseminated osseous tuberculosis is a rare disease. This is a report of two cases of disseminated osseous tuberculosis imaged with MRI at 1.5-T, CT, plain radiography and bone scintigraphy. CT and plain radiography demonstrated either highly destructive or cystic lesions with sclerotic margins. Bone scintigraphy and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90384-5

    authors: Quinn SF,Murray W,Prochaska J,Cochran C,Clark R

    更新日期:1987-01-01 00:00:00

  • Reproducibility of simultaneous imaging of intracranial and extracranial arterial vessel walls using an improved T1-weighted DANTE-SPACE sequence on a 3 T MR system.

    abstract:PURPOSE:To systematically investigate the scan-rescan, intra-observer, and inter-observer reproducibility of an improved DANTE-SPACE sequence for the simultaneous assessment of intra- and extracranial arterial vessel wall morphology. MATERIALS AND METHODS:Thirty-five healthy volunteers and 10 patients with atheroscler...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.04.016

    authors: Wan L,Zhang N,Zhang L,Long X,Jia S,Li Y,Liang D,Zheng H,Liu X

    更新日期:2019-10-01 00:00:00

  • Issues about the fMRI of the human spinal cord.

    abstract::Noninvasive functional studies on human spinal cord by means of magnetic resonance imaging (MRI) are gaining attention because of the promising applications in the study of healthy and injured central nervous system. The findings obtained are generally consistent with the anatomic knowledge based on invasive methods, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.10.015

    authors: Giove F,Garreffa G,Giulietti G,Mangia S,Colonnese C,Maraviglia B

    更新日期:2004-12-01 00:00:00

  • Automated classification of multispectral MR images using unsupervised constrained energy minimization based on fuzzy logic.

    abstract::Constrained energy minimization (CEM) has proven highly effective for hyperspectral (or multispectral) target detection and classification. It requires a complete knowledge of the desired target signature in images. This work presents "Unsupervised CEM (UCEM)," a novel approach to automatically target detection and cl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.03.009

    authors: Lin GC,Wang CM,Wang WJ,Sun SY

    更新日期:2010-06-01 00:00:00

  • Lee-Goldburg solid-state imaging.

    abstract::A new approach to solid-state imaging (SSI) is presented. The method relies on narrowing the resonance line using the Lee-Goldburg sequence. The technique is easy to implement in practice and may find widespread applications in materials science. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90409-s

    authors: De Luca F,Lugeri N,De Simone BC,Maraviglia B

    更新日期:1992-01-01 00:00:00

  • COmplex-Model-Based Estimation of thermal noise for fMRI data in the presence of artifacts.

    abstract::Due to the presence of artifacts induced by fast-imaging acquisition in functional magnetic resonance imaging (fMRI) studies, it is very difficult to estimate the variance of thermal noise by traditional methods in magnitude images. Moreover, the existence of incidental phase fluctuations impairs the validity of curre...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.12.007

    authors: Xu Y,Wu G,Rowe DB,Ma Y,Zhang R,Xu G,Li SJ

    更新日期:2007-09-01 00:00:00

  • Detection of viable myocardium in segments with fixed defects on thallium-201 scintigraphy: usefulness of magnetic resonance imaging early after acute myocardial infarction.

    abstract::To determine if magnetic resonance imaging (MRI) can be used to detect tissue viability in segments with persistent 201T1 defects early following acute myocardial infarction, 24 patients underwent MRI and adenosine 201T1 single photon emission computed tomography (SPECT) imaging at approximately 6 days. Infarction was...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90214-x

    authors: Johnston DL,Gupta VK,Wendt RE,Mahmarian JJ,Verani MS

    更新日期:1993-01-01 00:00:00

  • Neural activity-induced modulation of BOLD poststimulus undershoot independent of the positive signal.

    abstract::Despite intense research on the blood oxygenation level-dependent (BOLD) signal underlying functional magnetic resonance imaging, our understanding of its physiological basis is far from complete. In this study, it was investigated whether the so-called poststimulus BOLD signal undershoot is solely a passive vascular ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.04.003

    authors: Sadaghiani S,Uğurbil K,Uludağ K

    更新日期:2009-10-01 00:00:00

  • CPMG relaxation rate dispersion in dipole fields around capillaries.

    abstract::Transverse relaxation rates for Carr-Purcell-Meiboom-Gill (CPMG) sequences increase with inter-echo time in presence of microscopic magnetic field inhomogeneities due to nuclear spin diffusion. For a weak field approximation that includes diffusion effects, the CPMG relaxation rate shift for proton diffusion around ca...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.03.016

    authors: Kurz FT,Kampf T,Buschle LR,Heiland S,Schlemmer HP,Bendszus M,Ziener CH

    更新日期:2016-09-01 00:00:00

  • The Elgin marvel: using magnetic resonance imaging to look at a moldic fossil from the Permian of Elgin, Scotland, UK.

    abstract::The successful use of magnetic resonance imaging (MRI) of a moldic fossil dicynodont from the Permian aeolian Hopeman Sandstone Formation of Elgin, Scotland, UK, provides paleontologists with a nondestructive technique for examining fossils preserved in this fashion. For large moldic fossils, medical scanners such as ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.09.006

    authors: Clark ND,Adams C,Lawton T,Cruickshank AR,Woods K

    更新日期:2004-02-01 00:00:00

  • Pulseq-Graphical Programming Interface: Open source visual environment for prototyping pulse sequences and integrated magnetic resonance imaging algorithm development.

    abstract:PURPOSE:To provide a single open-source platform for comprehensive MR algorithm development inclusive of simulations, pulse sequence design and deployment, reconstruction, and image analysis. METHODS:We integrated the "Pulseq" platform for vendor-independent pulse programming with Graphical Programming Interface (GPI)...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.03.008

    authors: Ravi KS,Potdar S,Poojar P,Reddy AK,Kroboth S,Nielsen JF,Zaitsev M,Venkatesan R,Geethanath S

    更新日期:2018-10-01 00:00:00

  • Complimentary aspects of diffusion imaging and fMRI: II. Elucidating contributions to the fMRI signal with diffusion sensitization.

    abstract::Tissue water molecules reside in different biophysical compartments. For example, water molecules in the vasculature reside for variable periods of time within arteries, arterioles, capillaries, venuoles and veins, and may be within blood cells or blood plasma. Water molecules outside of the vasculature, in the extrav...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2007.02.006

    authors: Mulkern RV,Haker SJ,Maier SE

    更新日期:2007-07-01 00:00:00

  • NMR-contrast enhancement of experimental brain tumors with MnTPPS: qualitative evaluation by in vivo relaxometry.

    abstract::The applicability of the synthetic manganese porphyrin MnTPPS as tumor-selective MRI-contrast agent for brain tumors was investigated quantitatively by in vivo relaxometry. To exclude toxic effects of side products, the purification method for MnTPPS was improved. As a result, MnTPPS+Cl- (free acid) with a purity of m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90007-z

    authors: Bockhorst K,Hoehn-Berlage M,Ernestus RI,Tolxdorf T,Hossmann KA

    更新日期:1993-01-01 00:00:00

  • Diffusion tensor imaging of native and degenerated human articular cartilage.

    abstract::Diffusion tensor imaging (DTI) is potentially sensitive to collagen degeneration in cartilage. In this study, DTI was measured on human cartilage samples with interventions of trypsin and collagenase. The measured preferred diffusion direction was consistent with the zonal structure of collagen network. The glycosamin...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.10.015

    authors: Deng X,Farley M,Nieminen MT,Gray M,Burstein D

    更新日期:2007-02-01 00:00:00

  • A new RF transmit coil for foot and ankle imaging at 7T MRI.

    abstract::A four-channel Tic-Tac-Toe (TTT) transmit RF coil was designed and constructed for foot and ankle imaging at 7T MRI. Numerical simulations using an in-house developed FDTD package and experimental analyses using a homogenous phantom show an excellent agreement in terms of B1+ field distribution and s-parameters. Simul...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.09.005

    authors: Santini T,Kim J,Wood S,Krishnamurthy N,Farhat N,Maciel C,Raval SB,Zhao T,Ibrahim TS

    更新日期:2018-01-01 00:00:00

  • Quantitative MRI using T1ρ and T2 in human osteoarthritic cartilage specimens: correlation with biochemical measurements and histology.

    abstract:PURPOSE:A direct correlation between T(1ρ), T(2) and quantified proteoglycan and collagen contents in human osteoarthritic cartilage has yet to be documented. We aimed to investigate the orientation effect on T(1ρ) and T(2) values in human osteoarthritic cartilage and to quantify the correlation between T(1ρ), T(2) vs....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.09.004

    authors: Li X,Cheng J,Lin K,Saadat E,Bolbos RI,Jobke B,Ries MD,Horvai A,Link TM,Majumdar S

    更新日期:2011-04-01 00:00:00

  • Factors influencing contrast in fast spin-echo MR imaging.

    abstract::Multi-echo pulse sequences for producing T2-weighted images in much reduced imaging times have recently been developed for routine clinical use. A number of recent articles have described the contrast obtained with fast spin-echo (FSE) sequences and have generally indicated that they depict tissues very similarly to c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(92)90001-g

    authors: Constable RT,Anderson AW,Zhong J,Gore JC

    更新日期:1992-01-01 00:00:00

  • Reducing motion artifacts in two-dimensional Fourier transform imaging.

    abstract::The effects of motion in two-dimensional Fourier transform imaging (2DFT) are considered. Specific calculations describing the case of periodic motion are presented. The results predict the commonly seen artifact of image replication, sometimes referred to as ghosting. Expressions for both position and amplitude of th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(86)91046-5

    authors: Haacke EM,Patrick JL

    更新日期:1986-01-01 00:00:00

  • A highly accurate symmetric optical flow based high-dimensional nonlinear spatial normalization of brain images.

    abstract::Spatial normalization plays a key role in voxel-based analyses of brain images. We propose a highly accurate algorithm for high-dimensional spatial normalization of brain images based on the technique of symmetric optical flow. We first construct a three dimension optical model with the consistency assumption of inten...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.01.013

    authors: Wen Y,Hou L,He L,Peterson BS,Xu D

    更新日期:2015-05-01 00:00:00