Area of paradoxical signal drop after the administration of superparamagnetic iron oxide on the T2-weighted image of a patient with lymphangitic metastasis of the liver.

Abstract:

:We report a geographic area of prominent hypointensity in T2-weighted images vs. normal adjacent liver parenchyma in a patient with cholangiocarcinoma and lymphangitic metastasis of the liver after superparamagnetic iron oxide (SPIO) administration. The area showing this prominent signal drop showed Kupffer cell proliferation and lymphangitic metastasis during a pathologic examination.

journal_name

Magn Reson Imaging

authors

Lee Y,Lee JS,Kim CM,Jeong JY,Choi JI,Kim MJ

doi

10.1016/j.mri.2007.10.012

subject

Has Abstract

pub_date

2008-05-01 00:00:00

pages

577-82

issue

4

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(07)00439-0

journal_volume

26

pub_type

杂志文章
  • In vivo mapping of functional domains and axonal connectivity in cat visual cortex using magnetic resonance imaging.

    abstract::Noninvasive cognitive neuroimaging studies based on functional magnetic resonance imaging (fMRI) are of ever-increasing importance for basic and clinical neurosciences. The explanatory power of fMRI could be greatly expanded, however, if the pattern of the neuronal circuitry underlying functional activation could be m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.08.014

    authors: Kim DS,Kim M,Ronen I,Formisano E,Kim KH,Ugurbil K,Mori S,Goebel R

    更新日期:2003-12-01 00:00:00

  • Chemical exchange magnetic resonance imaging (CHEMI).

    abstract::Systems investigated with NMR spectroscopy are sometimes heterogeneous with respect to chemical composition, rates of chemical exchange, and other properties influencing magnetic resonance parameters. A method was developed to spatially encode reaction kinetic information and produce NMR images sensitive to chemical e...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90125-7

    authors: McFarland EW,Neuringer LJ,Kushmerick MJ

    更新日期:1988-09-01 00:00:00

  • Evidence for left-right asymmetries in the proton MRS of brain in normal volunteers.

    abstract::Although there is ample evidence in the literature for structural, functional and physiological asymmetries in the two hemispheres of human brain, direct evidence of a similar asymmetry in the in vivo distribution of brain metabolites has been lacking. In this study, the existence of chemical asymmetries in six differ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00342-6

    authors: Jayasundar R,Raghunathan P

    更新日期:1997-01-01 00:00:00

  • Quantitative magnetic resonance imaging of 'Fuyu' persimmon fruit during development and ripening.

    abstract::Qualitative and quantitative proton magnetic resonance imaging techniques were applied to persimmon (Diospyros kaki cv 'Fuyu') fruit during development and post-harvest ripening. Spin-lattice (T(1)) relaxation times in mesocarp parenchyma and vascular tissue exhibited a sigmoidal pattern of increase leading to commerc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00082-1

    authors: Clark CJ,MacFall JS

    更新日期:2003-07-01 00:00:00

  • A simple way to acquire T(1)-weighted MR images of rat liver with respiratory triggering.

    abstract::To acquire high-resolution T(1)-weighted images of the liver in rats, for which breath-holding cannot be ensured, respiratory triggering is essential. At the respiratory rate of 30-60 times/min in rats, however, T(1)-weighted images cannot be obtained with simple triggering. As a simple solution to this, we applied mu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.10.005

    authors: Morikawa S,Murayama H,Fujimoto S,Shiino A,Inubushi T

    更新日期:2012-04-01 00:00:00

  • Correlations and dissociations between BOLD signal and P300 amplitude in an auditory oddball task: a parametric approach to combining fMRI and ERP.

    abstract::A parametric method is proposed to examine the relationship between neuronal activity, measured with event related potentials (ERPs), and the hemodynamic response, observed with functional magnetic resonance imaging (fMRI), during an auditory oddball paradigm. After verifying that the amplitude of the evoked response ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00496-4

    authors: Horovitz SG,Skudlarski P,Gore JC

    更新日期:2002-05-01 00:00:00

  • Evaluation of pancreatic exocrine insufficiency by cine-dynamic MRCP using spatially selective inversion-recovery (IR) pulse: Correlation with severity of chronic pancreatitis based on morphological changes of pancreatic duct.

    abstract:PURPOSE:To evaluate the correlation between the pancreatic exocrine insufficiency estimated by cine-dynamic MRCP using spatially selective IR pulse and the severity stages (modified Cambridge classification) based on morphological changes of the pancreatic duct in patients with suspected chronic pancreatitis. MATERIAL...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.12.007

    authors: Yasokawa K,Ito K,Kanki A,Yamamoto A,Torigoe T,Sato T,Tamada T

    更新日期:2018-05-01 00:00:00

  • High resolution simultaneous imaging of intracranial and extracranial arterial wall with improved cerebrospinal fluid suppression.

    abstract:PURPOSE:To develop a technique for three dimensional (3D) high resolution joint imaging of intracranial and extracranial arterial walls with improved cerebrospinal fluid (CSF) suppression and good blood suppression based on T1 weighted sampling perfection with application optimized contrast using different angle evolut...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.08.004

    authors: Zhang L,Zhang N,Wu J,Liu X,Chung YC

    更新日期:2017-12-01 00:00:00

  • Intensity dependence of flow signal in slice selective velocity measurements.

    abstract::The quantitative determination of flow velocities using inflow-outflow techniques require slice selective excitation pulses. The intensity-velocity relationship for such methods is shown to be such that flow velocities estimated using techniques which rely on an absolute calibration of the measured intensity are sensi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90325-1

    authors: Saloner D

    更新日期:1989-01-01 00:00:00

  • Effect of ovariectomy on contrast agent diffusion into lumbar intervertebral disc: a dynamic contrast-enhanced MRI study in female rats.

    abstract:PURPOSE:The purpose was to study the effect of estrogen deficiency on contrast agent diffusion into intervertebral disc in a rat model. MATERIALS AND METHODS:Seven-month-old female Sprague-Dawley rats were used. Fourteen rats had ovariectomy, and nine rats had sham surgery. Magnetic resonance imaging (MRI) of sagittal...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.01.001

    authors: Deng M,Griffith JF,Zhu XM,Poon WS,Ahuja AT,Wang YX

    更新日期:2012-06-01 00:00:00

  • Self-navigated 3D whole-heart MRA for non-enhanced surveillance of thoracic aortic dilation: A comparison to CTA.

    abstract:PURPOSE:To prospectively compare image quality and reliability of a non-contrast, self-navigated 3D whole-heart magnetic resonance angiography (MRA) sequence with contrast-enhanced computed tomography angiography (CTA) for sizing of thoracic aortic aneurysm (TAA). METHODS:Self-navigated 3D whole-heart 1.5 T MRA was pe...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.12.003

    authors: Poskaite P,Pamminger M,Kranewitter C,Kremser C,Reindl M,Reiter G,Piccini D,Dumfarth J,Henninger B,Tiller C,Holzknecht M,Reinstadler SJ,Klug G,Metzler B,Mayr A

    更新日期:2021-02-01 00:00:00

  • Increased confidence of diagnosis of Ewing sarcoma using T2-weighted MR images.

    abstract::To assess whether magnetic resonance imaging could assist in diagnosing Ewing sarcoma, we retrospectively analyzed T1- and T2-weighted images of 24 consecutive solitary lytic bone lesions, including 18 cases of histologically proven Ewing sarcoma, and six aggressive-appearing benign lesions including eosinophilic gran...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92450-3

    authors: Hanna SL,Fletcher BD,Kaste SC,Fairclough DL,Parham DM

    更新日期:1994-01-01 00:00:00

  • Two-point method for T1 estimation with optimized gradient-echo sequence.

    abstract::Relaxation times estimation methods play a central role in various problems, such as magnetic resonance (MR) hardware calibration, tissue characterization, or temperature measurement. Previous studies have proposed optimization criteria to estimate the relaxation time T1 faster than with a multipoint method leading to...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00092-2

    authors: Imran J,Langevin F,Saint-Jalmes H

    更新日期:1999-11-01 00:00:00

  • Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain.

    abstract::Deep brain stimulation (DBS) is used increasingly in the field of movement disorders. The implanted electrodes create not only a prior risk to patient safety during MRI, but also a unique opportunity in the collection of functional MRI data conditioned by direct neural stimulation. We evaluated MRI-related heating for...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.02.007

    authors: Bhidayasiri R,Bronstein JM,Sinha S,Krahl SE,Ahn S,Behnke EJ,Cohen MS,Frysinger R,Shellock FG

    更新日期:2005-05-01 00:00:00

  • MR imaging of cervical spine motion with HASTE.

    abstract::The HASTE (half-Fourier acquisition single-shot turbo spin-echo) technique delivers images with T2-weighting in about half a second and could be ideal for fast dynamic studies when T2-weighting is needed. We evaluated cardiac-triggered HASTE to study cervical spine flexion/extension. The cervical spines of ten asympto...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00176-3

    authors: Duerinckx AJ,Yu WD,El-Saden S,Kim D,Wang JC,Sandhu HS

    更新日期:1999-04-01 00:00:00

  • Preliminary evaluation of accelerated microscopic diffusional kurtosis imaging (μDKI) in a rodent model of epilepsy.

    abstract:PURPOSE:Our study aimed to develop accelerated microscopic diffusional kurtosis imaging (μDKI) and preliminarily evaluated it in a rodent model of chronic epilepsy. METHODS:We investigated two μDKI acceleration schemes of reduced sampling density and angular range in a phantom and wild-type rats, and further tested μD...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.10.009

    authors: Ji Y,Lu D,Wu L,Qiu B,Song YQ,Sun PZ

    更新日期:2019-02-01 00:00:00

  • Cardiovascular applications of magnetic resonance imaging.

    abstract::Magnetic resonance imaging (MRI) is a completely noninvasive modality that has shown significant promise for the evaluation of the cardiovascular system. Our imaging technique employed electrocardiographic (ECG) gating, which resulted in well-resolved images of the cardiac structures. Patients and animals with a varie...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(84)90002-x

    authors: McNamara MT,Higgins CB

    更新日期:1984-01-01 00:00:00

  • Fully automated contour detection of the ascending aorta in cardiac 2D phase-contrast MRI.

    abstract:PURPOSE:In this study we proposed a fully automated method for localizing and segmenting the ascending aortic lumen with phase-contrast magnetic resonance imaging (PC-MRI). MATERIAL AND METHODS:Twenty-five phase-contrast series were randomly selected out of a large population dataset of patients whose cardiac MRI exam...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.11.010

    authors: Codari M,Scarabello M,Secchi F,Sforza C,Baselli G,Sardanelli F

    更新日期:2018-04-01 00:00:00

  • Determination of relaxation characteristics during preacute stage of lysophosphatidyl choline-induced demyelinating lesion in rat brain: an animal model of multiple sclerosis.

    abstract::Relaxation time measurements were carried out during the preacute stage of lesion progression in an animal model of demyelination created in the internal capsule (ic) area of the rat brain using lysophosphatidyl choline (LPC). T1 and T2 were determined both before and after 36 h of lesion creation. Histology carried o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.11.010

    authors: Degaonkar MN,Raghunathan P,Jayasundar R,Jagannathan NR

    更新日期:2005-01-01 00:00:00

  • Electrophoretic NMR studies of electrical transport in fluid-filled porous systems.

    abstract::An NMR technique is described which allows the observation of ionic charge carriers moving in the electric field within a porous system saturated with electrolyte solution. This method, which was recently developed in our laboratory, gives experimental access to the study of electric transport in disordered media on a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00267-3

    authors: Holz M,Heil SR,Schwab IA

    更新日期:2001-04-01 00:00:00

  • CPMG relaxation rate dispersion in dipole fields around capillaries.

    abstract::Transverse relaxation rates for Carr-Purcell-Meiboom-Gill (CPMG) sequences increase with inter-echo time in presence of microscopic magnetic field inhomogeneities due to nuclear spin diffusion. For a weak field approximation that includes diffusion effects, the CPMG relaxation rate shift for proton diffusion around ca...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.03.016

    authors: Kurz FT,Kampf T,Buschle LR,Heiland S,Schlemmer HP,Bendszus M,Ziener CH

    更新日期:2016-09-01 00:00:00

  • Clinical implementation of a multislice high spectral and spatial resolution-based MRI sequence to achieve unilateral full-breast coverage.

    abstract::High-resolution, single-slice, high spatial and spectral resolution (HiSS) breast magnetic resonance imaging (MRI) provides improved lesion conspicuity, margin definition and internal definition, as compared to conventional clinical MRI - and thus may provide better lesion characterization and increase breast MRI spec...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.022

    authors: Medved M,Newstead GM,Abe H,Olopade OI,Shimauchi A,Zamora MA,Karczmar GS

    更新日期:2010-01-01 00:00:00

  • Diffusion-weighted imaging versus superparamagnetic iron oxide (SPIO)-enhanced MRI: exclusive and combined values in the assessment of hepatic metastases.

    abstract:PURPOSE:The purpose was to validate diffusion-weighted imaging (DWI) in the assessment of hepatic metastases compared with superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance imaging. MATERIALS AND METHODS:For 21 consecutive patients with 160 metastases from extrahepatic malignancy and 25 benign focal lesi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.12.007

    authors: Kim H,Yu JS,Cho ES,Chung JJ,Kim JH,Kim DJ,Ahn JH,Kim KW

    更新日期:2012-05-01 00:00:00

  • GPU-accelerated nonparametric kinetic analysis of DCE-MRI data from glioblastoma patients treated with bevacizumab.

    abstract::Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is often used to examine vascular function in malignant tumors and noninvasively monitor drug efficacy of antivascular therapies in clinical studies. However, complex numerical methods used to derive tumor physiological properties from DCE-MRI images can b...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.09.007

    authors: Hsu YH,Ferl GZ,Ng CM

    更新日期:2013-05-01 00:00:00

  • Frequency-specific SSFP for hyperpolarized ¹³C metabolic imaging at 14.1 T.

    abstract::Metabolic imaging of hyperpolarized [1-(13)C] pyruvate co-polarized with [(13)C]urea by dynamic nuclear polarization with rapid dissolution is a promising new method for assessing tumor metabolism and perfusion simultaneously in vivo. Novel pulse sequences are required to enable dynamic imaging of multiple (13)C spect...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.037

    authors: von Morze C,Sukumar S,Reed GD,Larson PE,Bok RA,Kurhanewicz J,Vigneron DB

    更新日期:2013-02-01 00:00:00

  • Radiofrequency magnetic field gradient echoes have reduced sensitivity to susceptibility gradients.

    abstract::The amplitudes of gradient-echoes produced using static field gradients are sensitive to diffusion of tissue water during the echo evolution time. Gradient-echoes have been used to produce MR images in which image intensity is proportional to the self-diffusion coefficient of water. However, such measurements are subj...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00051-h

    authors: Karczmar G,River J,Koretsky AP

    更新日期:1995-01-01 00:00:00

  • Analysis of microporosity and setting of reactive powder concrete by proton nuclear relaxation.

    abstract::The proton spin-lattice relaxation measured at several frequencies leads to a resolved distribution of four Tli for reactive powder concrete (RPC). The typical Tli frequency dependences are quantitatively interpreted by a biphasic fast exchange model and a proton nuclear relaxation of hydrated paramagnetic ions at the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00063-0

    authors: Philippot S,Korb JP,Petit D,Zanni H

    更新日期:1998-06-01 00:00:00

  • Susceptibility-matched envelope for the correction of EPI artifacts.

    abstract::Fast gradient echo sequences, such as echo planer imaging (EPI) and spiral imaging, are vulnerable to artifacts resulting from B(0) inhomogeneities. A major contribution to these artifacts is the susceptibility variation across the head, which is most severe in regions adjacent to air-tissue interfaces, such as the mo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.07.011

    authors: Neufeld A,Assaf Y,Graif M,Hendler T,Navon G

    更新日期:2005-11-01 00:00:00

  • MRI of a retained sponge in a dog.

    abstract::Retained sponges after laparotomy may cause a broad spectrum of clinical symptoms and present a difficult diagnostic problem. We report a case of retained surgical sponge in a dog to illustrate the MRI findings of this infrequent but important cause of postoperative complications. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90358-3

    authors: Terrier F,Revel D,Hricak H,Feduska N

    更新日期:1985-01-01 00:00:00

  • Liposomal Gd-DTPA: effect of encapsulation on enhancement of hepatoma model by MRI.

    abstract::Liposomes entrapping gadolinium-DTPA (Gd-DTPA) were synthesized from 60 mole percent egg phosphatidylcholine (EPC) and 40 mole percent cholesterol or EPC alone entrapping Gd-DTPA in diameters of 100 and 200 nm. Rats bearing Morris hepatoma in their flanks were imaged by MR pre- and post-contrast with free Gd-DTPA and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90491-8

    authors: Unger EC,MacDougall P,Cullis P,Tilcock C

    更新日期:1989-07-01 00:00:00