Abstract:
PURPOSE:In this study we proposed a fully automated method for localizing and segmenting the ascending aortic lumen with phase-contrast magnetic resonance imaging (PC-MRI). MATERIAL AND METHODS:Twenty-five phase-contrast series were randomly selected out of a large population dataset of patients whose cardiac MRI examination, performed from September 2008 to October 2013, was unremarkable. The local Ethical Committee approved this retrospective study. The ascending aorta was automatically identified on each phase of the cardiac cycle using a priori knowledge of aortic geometry. The frame that maximized the area, eccentricity, and solidity parameters was chosen for unsupervised initialization. Aortic segmentation was performed on each frame using active contouring without edges techniques. The entire algorithm was developed using Matlab R2016b. To validate the proposed method, the manual segmentation performed by a highly experienced operator was used. Dice similarity coefficient, Bland-Altman analysis, and Pearson's correlation coefficient were used as performance metrics. RESULTS:Comparing automated and manual segmentation of the aortic lumen on 714 images, Bland-Altman analysis showed a bias of -6.68mm2, a coefficient of repeatability of 91.22mm2, a mean area measurement of 581.40mm2, and a reproducibility of 85%. Automated and manual segmentation were highly correlated (R=0.98). The Dice similarity coefficient versus the manual reference standard was 94.6±2.1% (mean±standard deviation). CONCLUSION:A fully automated and robust method for identification and segmentation of ascending aorta on PC-MRI was developed. Its application on patients with a variety of pathologic conditions is advisable.
journal_name
Magn Reson Imagingjournal_title
Magnetic resonance imagingauthors
Codari M,Scarabello M,Secchi F,Sforza C,Baselli G,Sardanelli Fdoi
10.1016/j.mri.2017.11.010subject
Has Abstractpub_date
2018-04-01 00:00:00pages
77-82eissn
0730-725Xissn
1873-5894pii
S0730-725X(17)30267-9journal_volume
47pub_type
杂志文章abstract::Currently, the North American symptomatic carotid endarterectomy trial, European carotid surgery trial, and common carotid method are used to measure the carotid stenosis for determining candidates for carotid endarterectomy using the projection angiography from different modalities such as digital subtraction angiogr...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2004.01.007
更新日期:2004-04-01 00:00:00
abstract:OBJECTIVE:Equivalent cross-relaxation rate imaging (ECRI) is an MRI technique used to evaluate qualitative changes in protein-water interactions. We aimed to prospectively evaluate the utility of ECRI for classification of adipocytic tumors. MATERIALS AND METHODS:Institutional Review Board approval was obtained and al...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.12.004
更新日期:2014-04-01 00:00:00
abstract::Contrast-enhanced 3D MR voiding urethrography (CE 3D MRVU) was performed on 5 healthy volunteers and 18 patients with urethral disease. After intravenous injection of 0.3 ml/kg gadolinium, the images of the three consecutive acquisitions of the 3D MRVU technique were obtained during voiding. The raw data were reconstr...
journal_title:Magnetic resonance imaging
pub_type: 临床试验,杂志文章
doi:10.1016/j.mri.2004.09.008
更新日期:2004-11-01 00:00:00
abstract::We have extended the utility of NMR as a technique to probe porous media structure over length scales of approximately 100-2000 microm by using the spin 1/2 noble gas 129Xe imbibed into the system's pore space. Such length scales are much greater than can be probed with NMR diffusion studies of water-saturated porous ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(01)00247-8
更新日期:2001-04-01 00:00:00
abstract::Biexponential T(2) relaxation of the localized water signal can be used for segmentation of spectroscopic volumes. To assess the specificity of the components an iterative relaxation measurement of the localized water signal (STEAM, 12 echo times, geometric spacing from 30 ms to 2000 ms) was combined with magnetizatio...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(01)00396-4
更新日期:2001-07-01 00:00:00
abstract::The advantages of event-related functional Magnetic Resonance Imaging (fMRI) and the increasing use of fMRI in cognitive experiments are both driving the development of techniques that allow images sensitive to the blood oxygen level-dependent effect to be acquired at ever-higher temporal resolution. Here, we present ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2005.12.030
更新日期:2006-05-01 00:00:00
abstract:OBJECTIVE:The purpose of this study is to investigate the correlation between the liver kinetics of gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) and liver histopathology in a mouse model of NASH by using dynamic contrast-enhanced MRI. MATERIALS AND METHODS:Twenty male C57/BL6 mice aged 8we...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.03.009
更新日期:2016-07-01 00:00:00
abstract::Functional MR (fMR) imaging techniques based on blood oxygenation level dependent (BOLD) effects were developed and applied to a rat brain tumor model to evaluate the potential utility of the method for characterizing tumor growth and regression following treatment. Rats bearing 9L brain tumors in situ were imaged dur...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00208-2
更新日期:1999-05-01 00:00:00
abstract::Spiral acquisition schemes offer unique advantages such as flow compensation, efficient k-space sampling and robustness against motion that make this option a viable choice among other non-Cartesian sampling schemes. For this reason, the main applications of spiral imaging lie in dynamic magnetic resonance imaging suc...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章,评审
doi:10.1016/j.mri.2010.03.036
更新日期:2010-07-01 00:00:00
abstract::A single-sided mobile NMR apparatus with a small Halbach magnet was constructed for the first time. It is lightweight, compact and exhibits good sensitivity. The weight of the device is only 2 kg, and the NMR signal of the pencil eraser block can be detected in one shot using the device. This study describes the chara...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2006.04.005
更新日期:2006-10-01 00:00:00
abstract::The radiologic findings from 60 patients with 86 internally deranged temporomandibular joints (TMJ) upon whom sequential imaging procedures had been performed over a period of two months to ten years were analyzed and correlated with clinical, surgical (72 joints), and pathological observations. Internal derangement o...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(89)90404-9
更新日期:1989-09-01 00:00:00
abstract::We retrospectively compared the diagnostic accuracy of abdominal ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI) studies performed on the same individual to determine the relative performance of these modalities in the evaluation of disease processes, arising from different intra-abdomi...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2003.01.001
更新日期:2004-01-01 00:00:00
abstract::MRI is applied to the visualisation of wetting heterogeneities evidenced by water proton T1 contrast at 0.1 T. Water saturated Fontainebleau sandstone samples were examined either in their original water-wet condition, or after silanation. T1, T2Hahn, and T2CPMG were measured for several porosities. T1 and T2CPMG of h...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)91557-1
更新日期:1994-01-01 00:00:00
abstract::Signal fluctuations in functional magnetic resonance imaging (fMRI) can result from a number of sources that may have a neuronal, physiologic or instrumental origin. To determine the relative contribution of these sources, we recorded physiological (respiration and cardiac) signals simultaneously with fMRI in human vo...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2009.02.004
更新日期:2009-10-01 00:00:00
abstract::1H Magnetic resonance imaging and 31P magnetic resonance spectroscopy (MRS) have been carried out in experimental rodent filariasis, i.e., Acanthocheilonema viteae infection in the rodent host, Mastomys coucha. The T2-weighted image of the infected host shows fine hyperintense thread like structures of adult filariid ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(97)00180-x
更新日期:1997-01-01 00:00:00
abstract::To assess whether magnetic resonance imaging could assist in diagnosing Ewing sarcoma, we retrospectively analyzed T1- and T2-weighted images of 24 consecutive solitary lytic bone lesions, including 18 cases of histologically proven Ewing sarcoma, and six aggressive-appearing benign lesions including eosinophilic gran...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)92450-3
更新日期:1994-01-01 00:00:00
abstract::Brain vascular damage accumulate in aging and often manifest as white matter hyperintensities (WMHs) on MRI. Despite increased interest in automated methods to segment WMHs, a gold standard has not been achieved and their longitudinal reproducibility has been poorly investigated. The aim of present work is to evaluate...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2020.11.008
更新日期:2021-02-01 00:00:00
abstract:PURPOSE:To present preliminary, in vivo temperature measurements during MRI of a pig implanted with a deep brain stimulation (DBS) system. MATERIALS AND METHODS:DBS system (Medtronic Inc., Minneapolis, MN) was implanted in the brain of an anesthetized pig. 3.0-T MRI was performed with a T/R head coil using the low-SAR...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.11.005
更新日期:2013-06-01 00:00:00
abstract::Resting fluctuations in arterial CO2 (a cerebral vasodilator) are believed to be an important source of low-frequency blood oxygenation level dependent (BOLD) signal fluctuations. In this study we focus on the two commonly used resting-states in functional magnetic resonance imaging experiments, eyes open and eyes clo...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.06.013
更新日期:2013-04-01 00:00:00
abstract::A parametric method is proposed to examine the relationship between neuronal activity, measured with event related potentials (ERPs), and the hemodynamic response, observed with functional magnetic resonance imaging (fMRI), during an auditory oddball paradigm. After verifying that the amplitude of the evoked response ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(02)00496-4
更新日期:2002-05-01 00:00:00
abstract::Myelin water fraction (MWF) images in brain tend to be spatially noisy with unknown or no apparent spatial patterns structure, so values are therefore typically averaged over large white matter (WM) volumes. We investigated the existence of an inherent spatial structure in MWF maps and explored the benefits of examini...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.09.012
更新日期:2020-04-01 00:00:00
abstract::Selective inversion recovery (SIR) is a quantitative magnetization transfer (qMT) method that provides estimates of parameters related to myelin content in white matter, namely the macromolecular pool-size-ratio (PSR) and the spin-lattice relaxation rate of the free pool (R1f), without the need for independent estimat...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2020.01.014
更新日期:2020-05-01 00:00:00
abstract::Multiparametric MRI is a remarkable imaging method for the assessment of patho-physiological processes. In particular, brain tumor characterization has taken advantage of the development of advanced techniques such as Diffusion- (DWI) and Perfusion- (PWI) Weighted Imaging, but a thorough analysis of meningiomas is sti...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.12.003
更新日期:2020-04-01 00:00:00
abstract::Quantification of magnetic resonance (MR)-based relaxation parameters of tendons and ligaments is challenging due to their very short transverse relaxation times, requiring application of ultra-short echo-time (UTE) imaging sequences. We quantify both T1 and T2* in the quadriceps and patellar tendons of healthy volunt...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.07.015
更新日期:2019-11-01 00:00:00
abstract:BACKGROUND:Ultra-high spatial resolution imaging of whole, ex vivo brains provides new opportunities to understand neurological disease. Recent work has demonstrated that 100 μm isotropic resolution can reveal anatomical details that are otherwise difficult to appreciate, but relied on fabrication facilities, fabricati...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2020.11.002
更新日期:2021-02-01 00:00:00
abstract::Using both quantitative computer-assisted analysis and visual estimation the MR imaging response of brain metastases to whole-brain radiotherapy (WBRT) was prospectively studied in 49 patients. Compared to the computer-assisted analysis, the precision of the visual estimation (by two readers in conference) of tumor re...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(96)00024-0
更新日期:1997-01-01 00:00:00
abstract::Retained sponges after laparotomy may cause a broad spectrum of clinical symptoms and present a difficult diagnostic problem. We report a case of retained surgical sponge in a dog to illustrate the MRI findings of this infrequent but important cause of postoperative complications. ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(85)90358-3
更新日期:1985-01-01 00:00:00
abstract:PURPOSE:To describe the MR appearances of hepatic sarcoidosis in patients with chronic liver disease and correlate the results with clinical stage of disease as measured with the Mayo end-stage liver disease (MELD) score. MATERIALS AND METHODS:Twenty patients with chronic liver disease and histopathological diagnosis ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.08.005
更新日期:2013-04-01 00:00:00
abstract::Magnetic resonance (MR) microscopy of up to 1-5-microm resolutions have been reported previously. The tested phantom structures, however, had widths one order of magnitude bigger than the reported resolutions, e.g., spherical beads or capillary tubes of tens-of-micron diameters or wall thicknesses have been imaged. In...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2009.01.002
更新日期:2009-07-01 00:00:00
abstract::Budd-Chiari syndrome (BCS) is a rare disorder caused by the obstruction of hepatic venous outflow, leading to sinusoidal congestion, ischemic injury to liver cells and portal hypertension. Long-term survival largely depends on whether hepatocellular carcinoma occurs. A recently available liver-specific contrast medium...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2010.10.013
更新日期:2011-05-01 00:00:00