Abstract:
:A single-sided mobile NMR apparatus with a small Halbach magnet was constructed for the first time. It is lightweight, compact and exhibits good sensitivity. The weight of the device is only 2 kg, and the NMR signal of the pencil eraser block can be detected in one shot using the device. This study describes the characteristics of this instrument, including the profile of static magnetic flux density, B0, the sensitivity in the depth direction and its effectiveness in one-dimensional profiling. Its usefulness in differentiating soft materials and evaluating the extent of damage of a material is demonstrated based on T2 relaxation data. The moisture absorbance also can be observed from the increase of the echo amplitude of the NMR spin echo signal.
journal_name
Magn Reson Imagingjournal_title
Magnetic resonance imagingauthors
Chang WH,Chen JH,Hwang LPdoi
10.1016/j.mri.2006.04.005subject
Has Abstractpub_date
2006-10-01 00:00:00pages
1095-102issue
8eissn
0730-725Xissn
1873-5894pii
S0730-725X(06)00130-5journal_volume
24pub_type
杂志文章abstract::Cells labeled by super paramagnetic iron-oxide (SPIO) nanoparticles are more easily seen in gradient echo MR images, but it has not been shown that the amount of nanoparticles or the number of cells can be directly quantified from MR images. This work utilizes a previously developed and improved Complex Image Summatio...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.08.003
更新日期:2017-01-01 00:00:00
abstract::Surfactant adsorption layers on polystyrene latex particles are investigated concerning their equilibrium exchange dynamics with surfactant molecules in solution. Pulsed field gradient (PFG) nuclear magnetic resonance (NMR) self-diffusion measurements of the nonionic surfactant C12(EO)5 are performed, making use of th...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00023-x
更新日期:1998-06-01 00:00:00
abstract::More than a dozen Nuclear Magnetic Resonance (NMR) imaging methods have been described using different radio-frequency pulse sequences, magnetic field gradient variations, and data processing. In order to have a theoretical understanding in the most general case, we have conceived a computer program for the simulation...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(84)90065-1
更新日期:1984-01-01 00:00:00
abstract::The phase difference method of phase contrast MR angiography provides a means of measuring the average velocity in each voxel of an MR scan. When static tissue is present in a voxel containing flow, the measured velocity is not the average velocity of the flow alone, but is lower due to the partial volume effect of th...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)91245-r
更新日期:1994-01-01 00:00:00
abstract::In this retrospective study we tested the hypothesis that the net effect of impaired electrical conduction and therefore increased heat dissipation in multiple sclerosis (MS) results in elevated lateral ventricular (LV) cerebrospinal fluid (CSF) diffusivity as a measure of brain temperature estimated in vivo using dif...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.11.002
更新日期:2015-04-01 00:00:00
abstract:OBJECT:Dynamic in vivo31P-NMR spectroscopy in combination with Magnetic Resonance Imaging (MRI) was used to study muscle bioenergetics of boreal and Arctic scallops (Pecten maximus and Chlamys islandica) to test the hypothesis that future Ocean Warming and Acidification (OWA) will impair the performance of marine inver...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.06.003
更新日期:2019-09-01 00:00:00
abstract::We report initial NMR studies of continuous flow laser-polarized xenon gas, both in unrestricted tubing, and in a model porous media. The study uses Pulsed Gradient Spin Echo-based techniques in the gas-phase, with the aim of obtaining more sophisticated information than just translational self-diffusion coefficients....
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(03)00156-5
更新日期:2003-04-01 00:00:00
abstract:PURPOSE:To present preliminary, in vivo temperature measurements during MRI of a pig implanted with a deep brain stimulation (DBS) system. MATERIALS AND METHODS:DBS system (Medtronic Inc., Minneapolis, MN) was implanted in the brain of an anesthetized pig. 3.0-T MRI was performed with a T/R head coil using the low-SAR...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.11.005
更新日期:2013-06-01 00:00:00
abstract:AIM:Matrix metalloproteases (MMPs) expression and their inhibitors (TIMPs) play an important role in tumor physiopathology, so we investigated the relationship between the magnetic resonance (MR) and MMPs/TIMPs expression by breast carcinomas. MATERIALS AND METHODS:MRI parameters of 64 breast carcinomas were investiga...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.04.005
更新日期:2016-10-01 00:00:00
abstract::The performance evaluation of a semi-supervised fuzzy c-means (SFCM) clustering method for monitoring brain tumor volume changes during the course of routine clinical radiation-therapeutic and chemo-therapeutic regimens is presented. The tumor volume determined using the SFCM method was compared with the volume estima...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(96)00386-4
更新日期:1997-01-01 00:00:00
abstract::The goal of this study was to determine whether presurgical metabolite levels measured by 3D MR Spectroscopic Imaging (MRSI) can accurately detect viable cancer within human brain tumor masses. A total of 31 patients (33 exams, 39 pathology correlations) with brain tumors were studied prior to surgical biopsy and/or r...
journal_title:Magnetic resonance imaging
pub_type: 临床试验,杂志文章
doi:10.1016/s0730-725x(01)00225-9
更新日期:2001-01-01 00:00:00
abstract::To investigate whether diffusion-related compartmentalization could be observed in skeletal muscle and whether this compartmentalization was affected by exercising, attenuation curves of signal against diffusion weighting were obtained in skeletal muscle of nine healthy volunteers at rest and after an exercise. Fiftee...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)00096-l
更新日期:1995-01-01 00:00:00
abstract:OBJECTIVE:To develop and validate a large field of view phantom and quality assurance software tool for the assessment and characterization of geometric distortion in MRI scanners commissioned for radiation therapy planning. MATERIALS AND METHODS:A purpose built phantom was developed consisting of 357 rods (6mm in dia...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章,评审
doi:10.1016/j.mri.2015.04.003
更新日期:2015-09-01 00:00:00
abstract:PURPOSE:Investigation of the feasibility of the R2⁎ mapping techniques by using latest theoretical models corrected for confounding factors and optimized for signal to noise ratio. THEORY AND METHODS:The improvement of the performance of state of the art magnetic resonance imaging (MRI) relaxometry algorithms is chall...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.08.006
更新日期:2017-01-01 00:00:00
abstract::Manganese-dipyridoxal diphosphate (Mn-DPDP) is a liver-selective contrast agent selectively taken up by the hepatocytes. Because of the analogy of structure with pyridoxine (vitamin B6), it was previously suggested that this compound can be selectively taken up by the facilitated transport of vitamers B6. To understan...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(96)00140-3
更新日期:1996-01-01 00:00:00
abstract::In vivo spin-lattice relaxation times, T1, of water and lipid protons of normal and atrophic muscles were measured, using the spatially resolved spectroscopy (SPARS) sequence, in a genetic avian model of myopathy. These T1 values were compared with those of the hypertrophic muscles. Although the water T1 values of mus...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(89)90550-x
更新日期:1989-05-01 00:00:00
abstract::Systems investigated with NMR spectroscopy are sometimes heterogeneous with respect to chemical composition, rates of chemical exchange, and other properties influencing magnetic resonance parameters. A method was developed to spatially encode reaction kinetic information and produce NMR images sensitive to chemical e...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(88)90125-7
更新日期:1988-09-01 00:00:00
abstract::In-plane flow quantification in MRI offers the potential for assessing vessel patency, and both volume flow rate and flow velocity. These techniques will have definite future impact on MR angiography. The method used in this paper employs motion artifact suppression technique (MAST) gradients to refocus spins travelli...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(88)90409-2
更新日期:1988-05-01 00:00:00
abstract::The purpose of this study is to report the significant differences found in the identification of lesions in cervical spinal cord of two patients with multiple sclerosis when using the BLADE T2-TSE and BLADE T2-TIRM sequences as opposed to the conventional T2-TSE and T2-TIRM sequences for sagittal acquisition at 1.5T....
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.07.008
更新日期:2013-12-01 00:00:00
abstract::To acquire high-resolution T(1)-weighted images of the liver in rats, for which breath-holding cannot be ensured, respiratory triggering is essential. At the respiratory rate of 30-60 times/min in rats, however, T(1)-weighted images cannot be obtained with simple triggering. As a simple solution to this, we applied mu...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2011.10.005
更新日期:2012-04-01 00:00:00
abstract::The adiabatic Shinnar-Le Roux (SLR) algorithm for radiofrequency (RF) pulse design enables systematic control of pulse parameters such as bandwidth, RF energy distribution and duration. Some applications, such as diffusion-weighted imaging (DWI) at high magnetic fields, would benefit from RF pulses that can provide gr...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.04.003
更新日期:2014-09-01 00:00:00
abstract::Magnetic resonance imaging (MRI) and localized proton MR spectroscopy (MRS) techniques have been applied for studying different maturation processes in the histochemistry of coconut (Cocos nucifera). Images of the tender and mature coconut are characterized by protons of the aqueous solution present in the cavity and ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(95)00033-d
更新日期:1995-01-01 00:00:00
abstract::Diffusion tensor imaging (DTI) is potentially sensitive to collagen degeneration in cartilage. In this study, DTI was measured on human cartilage samples with interventions of trypsin and collagenase. The measured preferred diffusion direction was consistent with the zonal structure of collagen network. The glycosamin...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2006.10.015
更新日期:2007-02-01 00:00:00
abstract::The chain dynamics of short-chain perfluoropolyether melts confined in Vycor nanoporous media has been characterized by field cycling nuclear magnetic resonance relaxometry and the dipolar correlation effect. The slowdown of motions under confinement, leading to larger residual dipolar couplings, has been probed by lo...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2006.11.018
更新日期:2007-05-01 00:00:00
abstract::The quantitative determination of flow velocities using inflow-outflow techniques require slice selective excitation pulses. The intensity-velocity relationship for such methods is shown to be such that flow velocities estimated using techniques which rely on an absolute calibration of the measured intensity are sensi...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(89)90325-1
更新日期:1989-01-01 00:00:00
abstract::For a number of reasons, it is desirable to fabricate coils which, for a known current, shall produce predetermined values of the magnetic field intensity at a number of points within a nuclear magnetic resonance imager. The calculation of the magnetic field intensity at a set of points involves the integration of the...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(89)90524-9
更新日期:1989-11-01 00:00:00
abstract::Spiral acquisition schemes offer unique advantages such as flow compensation, efficient k-space sampling and robustness against motion that make this option a viable choice among other non-Cartesian sampling schemes. For this reason, the main applications of spiral imaging lie in dynamic magnetic resonance imaging suc...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章,评审
doi:10.1016/j.mri.2010.03.036
更新日期:2010-07-01 00:00:00
abstract::The functional value of TurboFLASH MR imaging in the assessment of dynamic contrast enhancement and renal perfusion anomalies was evaluated in seven patients, who also underwent renal scintigraphy in baseline conditions. The basal renograms obtained from MAG-3 scintigraphy (mercapto acetyl triglycine, MAG3-S) and from...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)92534-8
更新日期:1994-01-01 00:00:00
abstract:PURPOSE:To develop a free-running framework for 3D isotropic simultaneous myocardial T1/T2 mapping and cine imaging. METHODS:Continuous data acquisition with 3D golden angle radial trajectory is used in conjunction with T2 preparation of varying echo times and inversion recovery (IR) pulses to enable simultaneous myoc...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.08.008
更新日期:2019-11-01 00:00:00
abstract:OBJECTIVE:3D Time-of-flight (TOF) magnetic resonance angiography is commonly used for vascular analyses. A quantification of longitudinal morphological changes usually requires the registration of TOF image sequences acquired at different time points. The aim of this study was to evaluate the precision of different 3D ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.08.011
更新日期:2014-12-01 00:00:00