Accuracy and reproducibility of automated white matter hyperintensities segmentation with lesion segmentation tool: A European multi-site 3T study.

Abstract:

:Brain vascular damage accumulate in aging and often manifest as white matter hyperintensities (WMHs) on MRI. Despite increased interest in automated methods to segment WMHs, a gold standard has not been achieved and their longitudinal reproducibility has been poorly investigated. The aim of present work is to evaluate accuracy and reproducibility of two freely available segmentation algorithms. A harmonized MRI protocol was implemented in 3T-scanners across 13 European sites, each scanning five volunteers twice (test-retest) using 2D-FLAIR. Automated segmentation was performed using Lesion segmentation tool algorithms (LST): the Lesion growth algorithm (LGA) in SPM8 and 12 and the Lesion prediction algorithm (LPA). To assess reproducibility, we applied the LST longitudinal pipeline to the LGA and LPA outputs for both the test and retest scans. We evaluated volumetric and spatial accuracy comparing LGA and LPA with manual tracing, and for reproducibility the test versus retest. Median volume difference between automated WMH and manual segmentations (mL) was -0.22[IQR = 0.50] for LGA-SPM8, -0.12[0.57] for LGA-SPM12, -0.09[0.53] for LPA, while the spatial accuracy (Dice Coefficient) was 0.29[0.31], 0.33[0.26] and 0.41[0.23], respectively. The reproducibility analysis showed a median reproducibility error of 20%[IQR = 41] for LGA-SPM8, 14% [31] for LGA-SPM12 and 10% [27] with the LPA cross-sectional pipeline. Applying the LST longitudinal pipeline, the reproducibility errors were considerably reduced (LGA: 0%[IQR = 0], p < 0.001; LPA: 0% [3], p < 0.001) compared to those derived using the cross-sectional algorithms. The DC using the longitudinal pipeline was excellent (median = 1) for LGA [IQR = 0] and LPA [0.02]. LST algorithms showed moderate accuracy and good reproducibility. Therefore, it can be used as a reliable cross-sectional and longitudinal tool in multi-site studies.

journal_name

Magn Reson Imaging

authors

Ribaldi F,Altomare D,Jovicich J,Ferrari C,Picco A,Pizzini FB,Soricelli A,Mega A,Ferretti A,Drevelegas A,Bosch B,Müller BW,Marra C,Cavaliere C,Bartrés-Faz D,Nobili F,Alessandrini F,Barkhof F,Gros-Dagnac H,Ranjeva JP

doi

10.1016/j.mri.2020.11.008

subject

Has Abstract

pub_date

2021-02-01 00:00:00

pages

108-115

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(20)30643-3

journal_volume

76

pub_type

杂志文章
  • Spatial normalization, bulk motion correction and coregistration for functional magnetic resonance imaging of the human cervical spinal cord and brainstem.

    abstract::Functional magnetic resonance imaging (fMRI) of the cortex is a powerful tool for neuroscience research, and its use has been extended into the brainstem and spinal cord as well. However, there are significant technical challenges with extrapolating the developments that have been achieved in the cortex to their use i...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.01.038

    authors: Stroman PW,Figley CR,Cahill CM

    更新日期:2008-07-01 00:00:00

  • Proton MR properties of lyophilized urine samples from normal and stone former individuals.

    abstract::Proton MR measurements were performed in lyophilized urine samples collected from 5 normals (N) and 5 idiopathic hypercalciuric recurrent stone formers (SF). T1 and T2 relaxation times were measured with a Bruker PC Multispec at 20 MHz and 37 degrees C in the lyophilized samples and in samples gradually rehydrated. Si...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90522-x

    authors: Azoury R,Abrashkin S,Weininger J,Iaina A

    更新日期:1988-01-01 00:00:00

  • In vivo MR evaluation of Gd-DTPA conjugated to dextran in normal rabbits.

    abstract::A dextran-Gd-DTPA compound has been recently synthesized utilizing 70,800 Da molecular weight dextran. This polymeric contrast agent for magnetic resonance imaging has been found chemically to be very stable and to demonstrate in vitro improved relaxivities of 1.5 to 2.3 times that of monomeric Gd-DTPA at 100 MHz. Thi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90515-2

    authors: Li KC,Quisling RG,Armitage FE,Richardson D,Mladinich C

    更新日期:1992-01-01 00:00:00

  • Reduced distortion artifact whole brain CBF mapping using blip-reversed non-segmented 3D echo planar imaging with pseudo-continuous arterial spin labeling.

    abstract:PURPOSE:To implement and evaluate interleaved blip-up, blip-down, non-segmented 3D echo planar imaging (EPI) with pseudo-continuous arterial spin labeling (pCASL) and post-processing for reduced susceptibility artifact cerebral blood flow (CBF) maps. MATERIALS AND METHODS:3D EPI non-segmented acquisition with a pCASL ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.08.011

    authors: Gai ND,Chou YY,Pham D,Butman JA

    更新日期:2017-12-01 00:00:00

  • Equivalent cross-relaxation rate imaging positively correlates with pathological grade and cell density of adipocytic tumors.

    abstract:OBJECTIVE:Equivalent cross-relaxation rate imaging (ECRI) is an MRI technique used to evaluate qualitative changes in protein-water interactions. We aimed to prospectively evaluate the utility of ECRI for classification of adipocytic tumors. MATERIALS AND METHODS:Institutional Review Board approval was obtained and al...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.12.004

    authors: Okuda H,Matsushima S,Sugiura H,Yamada K,Hamada S,Nishida Y,Ishiguro N

    更新日期:2014-04-01 00:00:00

  • NMR-based analysis of shear strength of weakly expansive clay in sodium chloride solution.

    abstract::A series of direct shear and nuclear magnetic resonance (NMR) tests were performed on a compacted weakly expansive clay saturated by sodium chloride (NaCl) solutions with different concentrations to study the effect of NaCl solution on the shear strength and its mechanism. Results from the direct shear tests show that...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.01.002

    authors: Yu H,Sun D,Tian H

    更新日期:2019-05-01 00:00:00

  • Diffusion and spatially resolved NMR in Berea and Venezuelan oil reservoir rocks.

    abstract::Conventional and spatially resolved proton NMR and relaxation measurements are used in order to study the molecular motions and the equilibrium and nonequilibrium diffusion of oils in Berea sandstone and Venezuelan reservoir rocks. In the water-saturated Berea a single line with T*2 congruent to 150 microseconds is ob...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90420-5

    authors: Murgich J,Corti M,Pavesi L,Voltini F

    更新日期:1992-01-01 00:00:00

  • Quantitative diffusion MRI using reduced field-of-view and multi-shot acquisition techniques: Validation in phantoms and prostate imaging.

    abstract:PURPOSE:To evaluate the reproducibility of quantitative diffusion measurements obtained with reduced Field of View (rFOV) and Multi-shot EPI (msEPI) acquisitions, using single-shot EPI (ssEPI) as a reference. METHODS:Diffusion phantom experiments, and prostate diffusion-weighted imaging in healthy volunteers and patie...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.04.006

    authors: Zhang Y,Holmes J,Rabanillo I,Guidon A,Wells S,Hernando D

    更新日期:2018-09-01 00:00:00

  • Magnetic resonance imaging of soft-tissue tumors: comparison with computed tomography.

    abstract::Twenty-seven patients with soft-tissue tumors were examined with a Picker 0.15-tesla resistive magnet and by computed tomography (CT). In all but one patient, MRI was better than or equal to CT in defining the anatomic extent of the tumor. We could determine whether major vascular structures were engulfed by the tumor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90398-4

    authors: Weekes RG,Berquist TH,McLeod RA,Zimmer WD

    更新日期:1985-01-01 00:00:00

  • MRI studies of the neurotoxic effects of L-2-chloropropionic acid on rat brain.

    abstract::L-2-Chloropropionic acid (L-CPA) is selectively toxic to rat cerebellar granule cells; necrosis is first observed about 36 hours after administration of L-CPA (750 mg/kg p.o.) becoming more marked by 48 h. Parallel to the onset of cell death an increase in cerebellar water content and sodium concentration has been rep...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00231-4

    authors: Williams RE,Prior M,Bachelard HS,Waterton JC,Checkley D,Lock EA

    更新日期:2001-02-01 00:00:00

  • A novel in silico platform for a fully automatic personalized brain tumor growth.

    abstract::Glioblastoma Multiforme is the most common and most aggressive type of brain tumors. Although accurate prediction of Glioblastoma borders and shape is absolutely essential for neurosurgeons, there are not many in silico platforms that can make such predictions. In the current study, an automatic patient-specific simul...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.12.012

    authors: Hajishamsaei M,Pishevar A,Bavi O,Soltani M

    更新日期:2020-05-01 00:00:00

  • Three-dimensional magnetic resonance imaging after ultrasonography for assessment of fetal gastroschisis.

    abstract::A 24-year-old woman (Gravida I, Para I) at estimated 32 weeks of pregnancy was referred to our department for evaluation of a suspected fetal gastroschisis. Ultrasound scan revealed multiple loops of dilated bowel outside the fetal abdomen and absence of membrane surrounding the herniated loops of the intestines. Thre...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.006

    authors: Sasaki Y,Miyamoto T,Hidaka Y,Satoh H,Takuma N,Sengoku K,Sugimori H,Inaoka T,Aburano T

    更新日期:2006-02-01 00:00:00

  • Dose distribution of proton beams with NMR measurements of Fricke-agarose gels.

    abstract::Fricke-agarose gels have been irradiated with a proton beam. Then samples have been extracted at different depths with respect to the beam penetration distance, corresponding to different irradiation doses. Relaxation times T1 and T2, measured at 17 MHz, appear sensitive to this kind of radiation. In particular, T2 ex...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00380-3

    authors: Di Capua S,D'Errico F,Egger E,Guidoni L,Luciani AM,Rosi A,Viti V

    更新日期:1997-01-01 00:00:00

  • Chemical exchange magnetic resonance imaging (CHEMI).

    abstract::Systems investigated with NMR spectroscopy are sometimes heterogeneous with respect to chemical composition, rates of chemical exchange, and other properties influencing magnetic resonance parameters. A method was developed to spatially encode reaction kinetic information and produce NMR images sensitive to chemical e...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90125-7

    authors: McFarland EW,Neuringer LJ,Kushmerick MJ

    更新日期:1988-09-01 00:00:00

  • Short T2 contrast with three-dimensional ultrashort echo time imaging.

    abstract::There is increasing interest in imaging short T2 species which show little or no signal with conventional magnetic resonance (MR) pulse sequences. In this paper, we describe the use of three-dimensional ultrashort echo time (3D UTE) sequences with TEs down to 8 μs for imaging of these species. Image contrast was gener...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.11.003

    authors: Du J,Bydder M,Takahashi AM,Carl M,Chung CB,Bydder GM

    更新日期:2011-05-01 00:00:00

  • Dependence of BOLD signal change on tactile stimulus intensity in SI of primates.

    abstract::Recently, we have demonstrated that the fine-digit topography (millimeter sized) previously identified in the primary somatosensory cortex (SI), using electrophysiology and intrinsic signal optical imaging, can also be mapped with submillimeter resolution using blood-oxygenation-level-dependent (BOLD) functional magne...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.05.002

    authors: Zhang N,Gore JC,Chen LM,Avison MJ

    更新日期:2007-07-01 00:00:00

  • The relaxivity of Gd-EOB-DTPA and Gd-DTPA in liver and kidney of the Wistar rat.

    abstract::The NMR relaxivities of Gd-EOB-DTPA and Gd-DTPA were determined in the kidney and liver of intact male Wistar rats immediately following sacrifice and in vitro in solutions and gels, at 1.5 T using a clinical MR scanner, T1 and T2 values of tissue samples were derived from spin-echo image sequences. Tissue gadolinium ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02097-d

    authors: Shuter B,Tofts PS,Wang SC,Pope JM

    更新日期:1996-01-01 00:00:00

  • Rapid and recoverable in vivo magnetic resonance imaging of the adult zebrafish at 7T.

    abstract::Increasing scientific interest in the zebrafish as a model organism across a range of biomedical and biological research areas raises the need for the development of in vivo imaging tools appropriate to this subject. Development of the embryonic and early stage forms of the subject can currently be assessed using opti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.013

    authors: Merrifield GD,Mullin J,Gallagher L,Tucker C,Jansen MA,Denvir M,Holmes WM

    更新日期:2017-04-01 00:00:00

  • Resolution and uncertainty of Laplace inversion spectrum.

    abstract::Laplace inversion has been widely used in analyzing nuclear magnetic resonance data to obtain a spectrum of decay time constant, such as the T(2) spectrum. However, due to the ill-conditioned nature of such inversion, it is difficult to determine the reliability and error of the resulting spectrum. This article descri...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2006.11.023

    authors: Song YQ

    更新日期:2007-05-01 00:00:00

  • Noninvasive evaluation of radiation-enhanced glioma cells invasiveness by ultra-high-field (1)H-MRS in vitro.

    abstract:INTRODUCTION:Glioma is the most common type of the primary CNS tumor. Radiotherapy is an important treatment measure after surgery. However, its highly invasive character is the main reason of postoperative recurrence. The aim of the study was to probe the correlation between the invasion ability and the metabolite cha...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.05.009

    authors: Xu YJ,Cui Y,Li HX,Shi WQ,Li FY,Wang JZ,Zeng QS

    更新日期:2016-10-01 00:00:00

  • Ferumoxide-enhanced MRI in patients with colorectal cancer and rising CEA: surgical correlation in early recurrence.

    abstract::The purpose of this study was to evaluate the value of Ferumoxide-enhanced magnetic resonance (MR) imaging in the detection of hepatic metastases in high-risk patients treated for colorectal cancer that have rising CEA. We used 19 patients treated previously for colorectal cancer with rising CEA levels underwent an un...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0730-725x(99)00134-4

    authors: Said B,McCart JA,Libutti SK,Choyke PL

    更新日期:2000-04-01 00:00:00

  • A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI. Part 1: Development of a computational method.

    abstract::Articular cartilage thickness is of relevance in various fields in diagnostics and biomedical research. In view of recent improvements of MR cartilage imaging a computational method has been developed for three-dimensional determination of cartilage thickness from tomographic datasets. A correction algorithm that comp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00012-x

    authors: Lösch A,Eckstein F,Haubner M,Englmeier KH

    更新日期:1997-01-01 00:00:00

  • Effect of physiological heart rate variability on quantitative T2 measurement with ECG-gated Fast Spin Echo (FSE) sequence and its retrospective correction.

    abstract:OBJECT:Quantitative T2 measurement is applied in cardiac Magnetic Resonance Imaging (MRI) for the diagnosis and follow-up of myocardial pathologies. Standard Electrocardiogram (ECG)-gated fast spin echo pulse sequences can be used clinically for T2 assessment, with multiple breath-holds. However, heart rate is subject ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.06.006

    authors: de Roquefeuil M,Vuissoz PA,Escanyé JM,Felblinger J

    更新日期:2013-11-01 00:00:00

  • Non-invasive temperature mapping using MRI: comparison of two methods based on chemical shift and T1-relaxation.

    abstract:PURPOSE:To implement and evaluate the accuracy of non-invasive temperature mapping using MRI methods based on the chemical shift (CS) and T1 relaxation in media of various heterogeneity during focal (laser) and external thermal energy deposition. MATERIALS AND METHODS:All measurements were performed on a 1.5 T superco...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00311-1

    authors: Bertsch F,Mattner J,Stehling MK,Müller-Lisse U,Peller M,Loeffler R,Weber J,Messmer K,Wilmanns W,Issels R,Reiser M

    更新日期:1998-05-01 00:00:00

  • Quantification of blood flow velocity in stenosed arteries by the use of finite elements: an observer-independent noninvasive method.

    abstract::Interventions for peripheral arterial disease should be designed to treat a physiological rather than an anatomic defect. Thus, for vascular surgeons, functional information about stenoses is as important as the anatomic one. In case of finding a stenosis by the use of magnetic resonance angiography, it would be a mat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.01.013

    authors: Mühlthaler H,Quatember B,Fraedrich G,Mühlthaler M,Pfeifer B,Greiner A,Schocke MF

    更新日期:2008-10-01 00:00:00

  • Influence of cholecystectomy on the flow dynamic pattern of bile in the extrahepatic bile duct: Assessment by cine-dynamic MRCP with spatially-selective IR pulse.

    abstract:PURPOSE:To evaluate the influence of cholecystectomy on the flow dynamic pattern of bile in the extrahepatic bile duct by using cine-dynamic MRCP with spatially-selective inversion-recovery (IR) pulse non-invasively. MATERIALS AND METHODS:56 patients with cholecystectomy and 48 control subjects without cholecystectomy...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.08.016

    authors: Sotozono H,Tamada T,Kanki A,Yasokawa K,Fukunaga T,Yamamoto A,Ito K

    更新日期:2020-12-01 00:00:00

  • A method for MR quantification of flow velocities in blood and CSF using interleaved gradient-echo pulse sequences.

    abstract::The aim of this study was to establish a rapid method for in vivo quantification of a large range of flow velocities using phase information. A basic gradient-echo sequence was constructed, in which flow was encoded along the slice selection direction by variation of the amplitude of a bipolar gradient without changes...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90535-3

    authors: Ståhlberg F,Mogelvang J,Thomsen C,Nordell B,Stubgaard M,Ericsson A,Sperber G,Greitz D,Larsson H,Henriksen O

    更新日期:1989-11-01 00:00:00

  • Diagnosis of discoid lateral meniscus of the knee on MR imaging.

    abstract::To establish the quantitative MR diagnostic criteria for discoid lateral meniscus, MR imaging of 60 knees with arthroscopically confirmed discoid lateral menisci and 134 knees with semilunar lateral menisci were analyzed. Following four quantitative parameters were measured. (1) Meniscal width (MW): The minimum menisc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00473-3

    authors: Samoto N,Kozuma M,Tokuhisa T,Kobayashi K

    更新日期:2002-01-01 00:00:00

  • Magnetic nanoparticle-induced hyperthermia treatment under magnetic resonance imaging.

    abstract::Super paramagnetic iron oxide Fe(3)O(4) nanoparticles prepared via photochemical reaction in pure form were used for inducing hyperthermia to treat subcutaneous Ehrlich carcinoma implanted in female mice. Our results indicate that the mean temperature profiles at the rectum, periphery of the tumor surface and at the c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.08.010

    authors: Elsherbini AA,Saber M,Aggag M,El-Shahawy A,Shokier HA

    更新日期:2011-02-01 00:00:00

  • Summary of special issue on gadolinium bioeffects and toxicity with a look to the future.

    abstract::This summary attempts to provide forward-looking concepts regarding gadolinium related toxicity, as discussed in further detail in this issue. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2016.09.002

    authors: Semelka RC,Ramalho M,Jay M

    更新日期:2016-12-01 00:00:00