A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI. Part 1: Development of a computational method.

Abstract:

:Articular cartilage thickness is of relevance in various fields in diagnostics and biomedical research. In view of recent improvements of MR cartilage imaging a computational method has been developed for three-dimensional determination of cartilage thickness from tomographic datasets. A correction algorithm that compensates for the error implied in the voxel based distance measurements is implemented. Four different thickness definitions have been applied to two numerical test structures in order to judge their usability in the medical realm. The results for each of the thickness measurement methods are shown as color-coded thickness maps wrapped round the test objects. An algorithm determining at each point the minimal distance from the articular surface to the bone-cartilage interface is suggested to give the most suitable demonstration of articular cartilage. This algorithm is successfully applied to a 3-dimensional data set of human knee joint cartilage obtained with a fat-suppressed gradient-echo sequence from a healthy volunteer. A non-invasive method for determining cartilage thickness could become a very valuable tool in diagnostic radiology, orthopaedic practice and biomechanics.

journal_name

Magn Reson Imaging

authors

Lösch A,Eckstein F,Haubner M,Englmeier KH

doi

10.1016/s0730-725x(97)00012-x

subject

Has Abstract

pub_date

1997-01-01 00:00:00

pages

795-804

issue

7

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(97)00012-X

journal_volume

15

pub_type

杂志文章
  • Spectroscopic imaging of the brain with phased-array coils at 3.0 T.

    abstract::The goal of this study was to develop and evaluate high-resolution magnetic resonance spectroscopic imaging (MRSI) utilizing the gains in signal-to-noise ratio (SNR) provided by combining higher magnetic field with high-sensitivity phased-array (PA) coils. We investigated the maximum improvement in spatial resolution ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.019

    authors: Xu D,Chen AP,Cunningham C,Osorio JA,Nelson SJ,Vigneron DB

    更新日期:2006-01-01 00:00:00

  • Magnetization transfer and T2 quantitation in normal appearing cortical gray matter and white matter adjacent to focal abnormality in patients with traumatic brain injury.

    abstract::Traumatic brain injury (TBI) is one of the commonest causes of morbidity and mortality in the developed countries with posttraumatic epilepsy and functional disability being its major sequelae. The purpose of this study was to test the hypothesis whether the normal appearing adjacent gray and white matter regions on T...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00189-9

    authors: Kumar R,Gupta RK,Rao SB,Chawla S,Husain M,Rathore RK

    更新日期:2003-10-01 00:00:00

  • Acoustic-integrated dynamic MR imaging for a patient with obstructive sleep apnea.

    abstract::Obstructive sleep apnea syndrome (OSAS) is caused by multi-level upper airway obstruction. Anatomic changes at the sites of obstruction may modify the physical or acoustic properties of snores. The surgical success of OSA depends upon precise localization of obstructed levels. We present a case of OSAS who received si...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.08.004

    authors: Chen YJ,Shih TT,Chang YC,Hsu YC,Huon LK,Lo MT,Pham VT,Lin C,Wang PC

    更新日期:2015-12-01 00:00:00

  • Undifferentiated (embryonal) sarcoma of the liver (USL): MRI findings including dynamic gadolinium enhancement.

    abstract::We report the MR appearance of undifferentiated (embryonal) sarcoma of the liver (USL) in a 13-year-old female who presented with a 1-year history of intermittent abdominal pain, weight loss, and fatigue. The tumor was a large, solitary, well-defined focal mass lesion with multiple cystic spaces, septations, and subst...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.02.003

    authors: Psatha EA,Semelka RC,Fordham L,Firat Z,Woosley JT

    更新日期:2004-07-01 00:00:00

  • Short TI short TR inversion recovery imaging using reduced flip angles.

    abstract::In this paper the effects of reducing the flip angle of the 90-degree observation pulse in inversion recovery imaging are described and analyzed. When incorporated in an IR sequence with a short inversion time (STIR), reduction to the 90-degree pulse allows a significant shortening of the repetition time without loss ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90418-l

    authors: Bakker CJ,Witkamp TD,Janssen WM

    更新日期:1991-01-01 00:00:00

  • Early assessment of breast cancer response to neoadjuvant chemotherapy by semi-quantitative analysis of high-temporal resolution DCE-MRI: preliminary results.

    abstract:PURPOSE:To evaluate whether semi-quantitative analysis of high temporal resolution dynamic contrast-enhanced MRI (DCE-MRI) acquired early in treatment can predict the response of locally advanced breast cancer (LABC) to neoadjuvant chemotherapy (NAC). MATERIALS AND METHODS:As part of an IRB-approved prospective study,...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.mri.2013.07.002

    authors: Abramson RG,Li X,Hoyt TL,Su PF,Arlinghaus LR,Wilson KJ,Abramson VG,Chakravarthy AB,Yankeelov TE

    更新日期:2013-11-01 00:00:00

  • Analysis of time reduction methods for magnetic resonance elastography of the brain.

    abstract::Magnetic resonance elastography (MRE) uses a phase-contrast MRI technique to image shear wave propagation in tissue followed by the mathematical inversion of the equations of motion governing tissue mechanics to noninvasively image tissue stiffness. This work investigates the impact of various MR sampling strategies d...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.06.016

    authors: Murphy MC,Glaser KJ,Manduca A,Felmlee JP,Huston J 3rd,Ehman RL

    更新日期:2010-12-01 00:00:00

  • Accuracy and precision of quantitative DCE-MRI parameters: How should one estimate contrast concentration?

    abstract:INTRODUCTION:Pharmacokinetic parameters derived from dynamic contrast-enhanced MRI (DCE-MRI) data are sensitive to acquisition and post-processing techniques, which makes it difficult to compare results obtained using different methods. In particular, one of the most important factors affecting estimation of model para...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.05.007

    authors: Wake N,Chandarana H,Rusinek H,Fujimoto K,Moy L,Sodickson DK,Kim SG

    更新日期:2018-10-01 00:00:00

  • Surface coil imaging of rat spine at 7.0 T.

    abstract::An inductively coupled surface coil for imaging the rat spine at 7 T is described. This planar circular probe was made from microwave substrate to limit the size of the coil and to minimize the magnetic susceptibility. The surface coil was used as a single transmit/receive coil and as a receive-only coil with a birdca...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90447-8

    authors: Banson ML,Cofer GP,Hedlund LW,Johnson GA

    更新日期:1992-01-01 00:00:00

  • MR Imaging of total hip arthroplasty: comparison among sequences to study the sciatic nerve at 1.5 T.

    abstract:PURPOSE:This study was done to test a series of MR sequences for evaluating the sciatic nerve after total hip arthroplasty (THA). MATERIAL AND METHODS:The study protocol was approved by the institutional review board. Informed consent was obtained from all patients. Twenty-five patients (11 men and 14 women mean age: ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.06.009

    authors: Tagliafico A,Podestà A,Assini A,Boccacini L,Serafini G,Calabrese M,Martinoli C

    更新日期:2010-11-01 00:00:00

  • MRI observation of heavy metal transport in aquifer matrices down to sub-mg quantities.

    abstract::In this contribution, we report results from MRI studies of the propagation of heavy metal ions through columns packed with sandy aquifer materials. Both sorption of low concentrations of heavy metal ions from water flowing through the column and the formation of sorption traces produced from initially localized highe...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00166-8

    authors: Nestle N,Baumann T,Wunderlich A,Niessner R

    更新日期:2003-04-01 00:00:00

  • The comparison of the performance of 3 T and 7 T T2 mapping for untreated low-grade cartilage lesions.

    abstract:OBJECTIVE:To investigate T2 mapping as a possible marker for low-grade human articular cartilage lesions during a one-year follow-up, possible changes during the follow-up and compare the reliability and sensitivity of these measurements on high-field (3 T) and ultra-high-field (7 T) MRI scanners. DESIGN:Twenty-one pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.09.021

    authors: Juras V,Schreiner M,Laurent D,Zbýň Š,Mlynarik V,Szomolanyi P,Hager B,Scotti C,Goldhahn J,Heule R,Bieri O,Trattnig S

    更新日期:2019-01-01 00:00:00

  • Fast multi-contrast MRI reconstruction.

    abstract::Multi-contrast magnetic resonance imaging (MRI) is a useful technique to aid clinical diagnosis. This paper proposes an efficient algorithm to jointly reconstruct multiple T1/T2-weighted images of the same anatomical cross section from partially sampled k-space data. The joint reconstruction problem is formulated as m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.025

    authors: Huang J,Chen C,Axel L

    更新日期:2014-12-01 00:00:00

  • Improved sensitivity of MRI in multiple sclerosis by use of extensive standardized procedures.

    abstract::The relative value of two different MRI procedures for the assessment of infratentorial extension in multiple sclerosis (MS) was studied. Multislice spin-echo techniques were used overall. Procedure A consisted of parasagittal T1-weighted images (500/30) and axial T2-weighted images (2500/30, 2500/120). Procedure B co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90547-x

    authors: Van de Vyver FL,Truyen L,Gheuens J,Degryse HR,Peersman GV,Martin JJ

    更新日期:1989-05-01 00:00:00

  • Neurophysiological and functional MRI evidence of reorganization of cortical motor areas in cerebral arteriovenous malformation.

    abstract::Functional magnetic resonance imaging (fMRI) research has shown that brain arteriovenous malformations (AVMs) lead to reorganization of cortical motor areas. Since it is known that blood oxygenation level-dependent signal in fMRI may be influenced by the hemodynamic perturbation associated with the presence of the AVM...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.029

    authors: Caramia F,Francia A,Mainero C,Tinelli E,Palmieri MG,Colonnese C,Bozzao L,Caramia MD

    更新日期:2009-12-01 00:00:00

  • T2* measurements in human brain at 1.5, 3 and 7 T.

    abstract::Measurements have been carried out in six subjects at magnetic fields of 1.5, 3 and 7 T, with the aim of characterizing the variation of T2* with field strength in human brain. Accurate measurement of T2* in the presence of macroscopic magnetic field inhomogeneity is problematic due to signal decay resulting from thro...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.02.014

    authors: Peters AM,Brookes MJ,Hoogenraad FG,Gowland PA,Francis ST,Morris PG,Bowtell R

    更新日期:2007-07-01 00:00:00

  • Localization of ischemia in canine hearts using tagged rotated long axis MR images, endocardial surface stretch and wall thickening.

    abstract::Tagged magnetic resonance imaging allows the noninvasive measurement of regional systolic myocardial deformations and helps localize ischemic regions in the left ventricle (LV). The objective of this study was to evaluate the potential accuracy of localizing ischemic regions in the LV using endocardial and epicardial ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00161-6

    authors: Denisova O,Shapiro EP,Weiss JL,Azhari H

    更新日期:1997-01-01 00:00:00

  • Dixon-based fat-free MR-angiography compared to first pass and steady-state high-resolution MR-angiography using a blood pool contrast agent.

    abstract:INTRODUCTION:Compared to standard arterial-only first-pass MR-angiography (FPMRA), imaging during the equilibrium phase of a blood pool contrast agent (steady state) has been shown to provide higher image quality and better stenosis grading. Homogenous Dixon fat-suppression promises to increase contrast by suppression ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.07.005

    authors: Homsi R,Gieseke J,Kukuk GM,Träber F,Willinek WA,Schild HH,Hadizadeh DR

    更新日期:2015-11-01 00:00:00

  • Dynamic contrast-enhanced MRI to assess hepatocellular carcinoma response to Transarterial chemoembolization using LI-RADS criteria: A pilot study.

    abstract:PURPOSE:To identify quantitative dynamic contrast-enhanced (DCE)-MRI perfusion parameters indicating tumor response of hepatocellular carcinoma (HCC) to transarterial chemoembolization (TACE). MATERIALS AND METHODS:This prospective pilot study was approved by our institutional review board; written and informed consen...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.mri.2019.06.017

    authors: Thibodeau-Antonacci A,Petitclerc L,Gilbert G,Bilodeau L,Olivié D,Cerny M,Castel H,Turcotte S,Huet C,Perreault P,Soulez G,Chagnon M,Kadoury S,Tang A

    更新日期:2019-10-01 00:00:00

  • Acute pancreatic graft fistula and peripancreatic fluid collection: demonstration by secretin-stimulated MRI.

    abstract::Peripancreatic fluid collections are among the common post pancreas transplant complications, which are mainly due to leakage from the anastomosis site to bowel and graft pancreatitis. Differentiation between these two entities is important because they are treated differently. In this case, secretin stimulated magnet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.02.003

    authors: Alkaade S,Fattahi R,Balci NC,Akduman EI,Garvin PJ,Modanlou KA,Burton FR

    更新日期:2009-09-01 00:00:00

  • Quantification of synovistis by MRI: correlation between dynamic and static gadolinium-enhanced magnetic resonance imaging and microscopic and macroscopic signs of synovial inflammation.

    abstract::Dynamic and static gadolinium-diethylenetriaminepentaacetic acid(Gd-DTPA)-enhanced magnetic resonance imaging (MRI) were evaluated as measures of joint inflammation in arthritis, by a comparison with macroscopic and microscopic signs of synovitis. Furthermore, the importance of the size of the evaluated synovial areas...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00008-3

    authors: Ostergaard M,Stoltenberg M,Løvgreen-Nielsen P,Volck B,Sonne-Holm S,Lorenzen I

    更新日期:1998-09-01 00:00:00

  • Off-resonance binomial preparatory pulse technique for high sensitivity MRI of H2O17.

    abstract::H2O17 is a freely diffusible tracer and naturally occurring isotope of O16 detectable by MRI and has been shown to be useful for assessing cerebral perfusion in animal studies using direct and indirect MR detection techniques. However, earlier MR techniques are either not sensitive to changes in small concentrations o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.09.005

    authors: Sood R

    更新日期:2004-02-01 00:00:00

  • Automatic motion correction of Musculoskeletal MRI using DSLR camera.

    abstract::The purpose of this study is to illustrate motion correction in Musculoskeletal (MSK) Magnetic Resonance Imaging (MRI) through utilization of information from an optical tracker to capture the extent and instant of motion. A Digital Single Lens Reflexive camera is employed as the optical tracker to capture the extent ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.12.031

    authors: Chikop SA,Anchan ABS,Koulagi G,Honnedevasthana AA,Imam S,Geethanath S

    更新日期:2018-05-01 00:00:00

  • Issues about the fMRI of the human spinal cord.

    abstract::Noninvasive functional studies on human spinal cord by means of magnetic resonance imaging (MRI) are gaining attention because of the promising applications in the study of healthy and injured central nervous system. The findings obtained are generally consistent with the anatomic knowledge based on invasive methods, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.10.015

    authors: Giove F,Garreffa G,Giulietti G,Mangia S,Colonnese C,Maraviglia B

    更新日期:2004-12-01 00:00:00

  • MRI of the normal hippocampus.

    abstract::Before it is possible to use MR imaging to investigate changes in the hippocampus in disease processes such as epilepsy and memory disorders, it is imperative that normal variations are defined. Using specific anatomic locations, we evaluated the hippocampi of 29 normal volunteers with coronal MR studies. Mild variati...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90035-k

    authors: Bronen RA,Cheung G

    更新日期:1991-01-01 00:00:00

  • Comparison between end-tidal CO₂ and respiration volume per time for detecting BOLD signal fluctuations during paced hyperventilation.

    abstract::Respiratory motion and capnometry monitoring were performed during blood oxygen level-dependent (BOLD) functional magnetic resonance imaging (fMRI) of the brain while a series of paced hyperventilation tasks were performed that caused significant hypocapnia. Respiration volume per time (RVT) and end-tidal carbon dioxi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.07.011

    authors: Vogt KM,Ibinson JW,Schmalbrock P,Small RH

    更新日期:2011-11-01 00:00:00

  • Localized high-resolution DTI of the human midbrain using single-shot EPI, parallel imaging, and outer-volume suppression at 7T.

    abstract::Localized high-resolution diffusion tensor images (DTI) from the midbrain were obtained using reduced field-of-view (rFOV) methods combined with SENSE parallel imaging and single-shot echo planar (EPI) acquisitions at 7T. This combination aimed to diminish sensitivities of DTI to motion, susceptibility variations, and...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.01.013

    authors: Wargo CJ,Gore JC

    更新日期:2013-07-01 00:00:00

  • Dynamic contrast-enhanced 3D breath hold MRA using a multiple variable orientation slab acquisition.

    abstract::With the conventional 3D MR angiographic sequences, it is difficult to prescribe multiple phases in different orientations, though multiple phases may be prescribed in the same orientation as the initial scan. Magnetic resonance angiography (MRA) was performed in which three slabs were prescribed in different orientat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00003-x

    authors: Shetty AN,Bis KG

    更新日期:1999-07-01 00:00:00

  • The application of NMR imaging to the studies of enhanced oil recovery in China.

    abstract::The advantages of the application of NMR imaging to the studies of enhanced oil recovery methods that include polymer slug flooding, combination slug flooding, and thermal soaking are described. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00192-0

    authors: Weimin W,Dongjiang L,Wei L

    更新日期:1996-01-01 00:00:00

  • Quantitative computer-assisted analysis vs. visual estimation of MR imaging response of brain metastases to radiotherapy.

    abstract::Using both quantitative computer-assisted analysis and visual estimation the MR imaging response of brain metastases to whole-brain radiotherapy (WBRT) was prospectively studied in 49 patients. Compared to the computer-assisted analysis, the precision of the visual estimation (by two readers in conference) of tumor re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00024-0

    authors: Taphoorn MJ,Potman RA,Barkhof F,Weerts JG,Valk J,Karim AB,Heimans JJ

    更新日期:1997-01-01 00:00:00