Diagnosis of discoid lateral meniscus of the knee on MR imaging.

Abstract:

:To establish the quantitative MR diagnostic criteria for discoid lateral meniscus, MR imaging of 60 knees with arthroscopically confirmed discoid lateral menisci and 134 knees with semilunar lateral menisci were analyzed. Following four quantitative parameters were measured. (1) Meniscal width (MW): The minimum meniscal width on the coronal slice. (2) Ratio of the meniscus to the tibia (RMT): The ratio of minimum meniscal width to maximum tibial width on the coronal slice. (3) Percent coverage of the meniscus (PCM): The ratio of the sum of the width of the anterior and posterior horns to the meniscal diameter on the sagittal slice showing the maximum meniscal diameter. (4) Continuity of the anterior and posterior horns (CAPH): The number of consecutive sagittal slices showing continuity between the anterior and posterior horns of the meniscus on the sagittal slice. The cut-off values of each parameter to discriminate between the discoid and semilunar meniscus were calculated based on a univariate logistic regression analysis. The sensitivity and specificity were also calculated for each of 4 parameters and combinations of these parameters. The cut-off value was 15 mm for the MW, 20% for the RMT, 75% for the PCM, and 3 slices for the CAPH. The sensitivity and specificity of the four parameters ranged between 87% and 50% and between 99% and 92%, respectively. The most accurate diagnostic criterion was either the RMT > or = 20% or the PCM > or = 75%, and the sensitivity and specificity were 95% and 97%, respectively, even when torn menisci were included.

journal_name

Magn Reson Imaging

authors

Samoto N,Kozuma M,Tokuhisa T,Kobayashi K

doi

10.1016/s0730-725x(02)00473-3

subject

Has Abstract

pub_date

2002-01-01 00:00:00

pages

59-64

issue

1

eissn

0730-725X

issn

1873-5894

pii

S0730725X02004733

journal_volume

20

pub_type

杂志文章
  • A volume resolution phantom for MRI.

    abstract::Multisite quantitative magnetic resonance imaging (qMRI) of volume requires a small isotropic point spread-function (PSF) that is spatially, temporarily, and platform invariant. A phantom which will allow rapid assessment of this metric throughout the imaged volume without repositioning will assist certification of im...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.07.002

    authors: Moon SY,Hornak JP

    更新日期:2010-02-01 00:00:00

  • Quantitative longitudinal fluid saturation profiles with a slice-selected CPMG sequence.

    abstract::A technique for obtaining quantitative longitudinal saturation/porosity profiles of rock cores which are longer than the NMR coil has been developed. The slice-selected experiment uses a prefocused pulse in conjunction with a magnetic field gradient for the localization and a CPMG sequence to sample the data. A variet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91547-4

    authors: Pierens GK,Peyron M,Lucas AJ,Carpenter TA,Hall LD,Potter GF,Stewart RC,Phelps DW

    更新日期:1994-01-01 00:00:00

  • Perfusion MR imaging and proton MR spectroscopic imaging in differentiating necrotizing cerebritis from glioblastoma multiforme.

    abstract::We describe a lesion with the magnetic resonance imaging (MRI) characteristics of a glioblastoma mutiforme and demonstrate how perfusion MRI and proton MR spectroscopic imaging can be used to differentiate necrotizing cerebritis from what appeared to be a high-grade glioma. A 43-year-old woman presented to her physici...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.09.028

    authors: Pivawer G,Law M,Zagzag D

    更新日期:2007-02-01 00:00:00

  • MR imaging of late onset orbital rhabdomyosarcoma with intracranial extension.

    abstract::Today, patients with alveolar rhabdomyosarcoma have a favorable prognosis with a survival rate of more than 80%, due to modern radiotherapy. However, those patients with secondary meningeal involvement are still afflicted with a mortality rate of 90% unless a different therapeutic approach is taken. We report a case o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90035-c

    authors: Judmaier W,Birbamer G,Buchberger W,Mihatsch T,Lener M,Felber S

    更新日期:1993-01-01 00:00:00

  • Reducing SAR in parallel excitation using variable-density spirals: a simulation-based study.

    abstract::Parallel excitation using multiple transmit channels has emerged as an effective method to shorten multidimensional spatially selective radiofrequency (RF) pulses, which have a number of important applications, including B1 field inhomogeneity correction in high-field MRI. The specific absorption rate (SAR) is a prima...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.02.003

    authors: Liu Y,Feng K,McDougall MP,Wright SM,Ji J

    更新日期:2008-10-01 00:00:00

  • Quantitation of non-Einstein diffusion behavior of water in biological tissues by proton MR diffusion imaging: synthetic image calculations.

    abstract::The non-Einstein diffusion behavior of water in a model biological tissue system, intact duck embryos, has been investigated by the use of an in vivo proton pulsed-gradient spin-echo (PGSE) MR imaging technique. Multiple-frame MR images of the intact duck embryos and control solution (0.5 mM CuSO4 doped water) were ac...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90476-t

    authors: Cheng KH

    更新日期:1993-01-01 00:00:00

  • Abdominal aortic aneurysm evaluation: comparison of US, CT, MRI, and angiography.

    abstract::We studied 26 cases of abdominal aortic aneurysm with magnetic resonance imaging (MRI), computed tomography (CT), ultrasonography (US), and angiography. Data acquired were compared to those obtained at surgery. Diameter of the aneurysm was correctly defined in all cases by CT and MRI, while angiography underestimated ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90089-k

    authors: Pavone P,Di Cesare E,Di Renzi P,Marsili L,Ventura M,Spartera C,Passariello R

    更新日期:1990-01-01 00:00:00

  • Effects of 3D sampling in (k, t)-space on temporal qualities of dynamic MRI.

    abstract::3D (kx, ky, t)-space analysis is invoked to provide insights into dynamic magnetic resonance imaging (DMRI) with arbitrary k-space sampling trajectories. The effects of 3D sampling in (kx, ky, t) are analyzed theoretically and verified with computer simulation. The analyses show that a 3D sampling pattern that is more...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.04.009

    authors: Park JB,Nishimura DG

    更新日期:2006-10-01 00:00:00

  • Magnetic resonance cholangiopancreatography (MRCP) of intraductal papillary-mucinous neoplasm (IPMN) of the pancreas: case report.

    abstract::The intraductal papillary-mucinous neoplasm (IPMN) is the rarest of the cystic pancreatic tumors. Endoscopic retrograde cholangiopancreatography (ERCP) is currently the gold standard for evaluating IPMN's and can demonstrate dilatation of the main duct or side branches, mural nodules, filling defects, and communicatio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00440-4

    authors: Peters HE,Vitellas KM

    更新日期:2001-10-01 00:00:00

  • Magnetic resonance imaging of mouse Ehrlich carcinoma growth inhibition by thiacarpine, an analogue of cytotoxic marine alkaloid polycarpine.

    abstract::The anticancer effect of thiacarpine, a synthetic analogue of the known cytotoxic alkaloid polycarpine isolated from the Pacific ascidian Polycarpa aurata, was investigated in vivo in experiments using mouse solid Ehrlich carcinoma tumor as the target. A high-resolution magnetic resonance imaging (MRI) technique using...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.01.014

    authors: Agafonova IG,Radchenko OS,Novikov VL,Aminin DL,Stonik VA

    更新日期:2008-07-01 00:00:00

  • Using nine degrees-of-freedom registration to correct for changes in voxel size in serial MRI studies.

    abstract::Quantitative longitudinal brain magnetic resonance (MR) studies may be confounded by scanner-related drifts in voxel sizes. Total intracranial volume (TIV) normalisation is commonly used to correct serial cerebral volumetric measurements for these drifts. We hypothesised that automated rigid-body registration of whole...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.057

    authors: Whitwell JL,Schott JM,Lewis EB,MacManus DG,Fox NC

    更新日期:2004-09-01 00:00:00

  • Effects of trabecular bone on marrow relaxation in the tibia.

    abstract::The effects of bone on marrow relaxation in the trabecular volume of the most proximal 3 cm in the left tibia were studied with a RF-spoiled gradient echo MRI protocol on a 1.0 T MR unit. The MR measurements were performed on six healthy volunteers, and repeated within one month in order to assess the precision of the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00159-3

    authors: Fransson A,Grampp S,Imhof H

    更新日期:1999-01-01 00:00:00

  • MRI inter-slice reconstruction using super-resolution.

    abstract::MRI reconstruction using super-resolution is presented and shown to improve spatial resolution in cases when spatially-selective RF pulses are used for localization. In 2-D multislice MRI, the resolution in the slice direction is often lower than the in-plane resolution. For certain diagnostic imaging applications, is...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00511-8

    authors: Greenspan H,Oz G,Kiryati N,Peled S

    更新日期:2002-06-01 00:00:00

  • 4D MR phase and magnitude segmentations with GPU parallel computing.

    abstract::The increasing size and number of data sets of large four dimensional (three spatial, one temporal) magnetic resonance (MR) cardiac images necessitates efficient segmentation algorithms. Analysis of phase-contrast MR images yields cardiac flow information which can be manipulated to produce accurate segmentations of t...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.019

    authors: Bergen RV,Lin HY,Alexander ME,Bidinosti CP

    更新日期:2015-01-01 00:00:00

  • MRI-guided breast vacuum biopsy: Localization of the lesion without contrast-agent application using diffusion-weighted imaging.

    abstract:OBJECTIVE:In magnetic resonance-guided breast vacuum biopsies, the contrast agent for targeting suspicious lesions can typically be applied only once during an intervention, due to the slow elimination of the gadolinium chelate from the extracellular fluid space. This study evaluated the feasibility of diffusion-weight...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.12.006

    authors: Berger N,Varga Z,Frauenfelder T,Boss A

    更新日期:2017-05-01 00:00:00

  • 23Na magnetic resonance imaging: distribution of brine in muscle.

    abstract::Magnetic resonance imaging (MRI) has been used to characterize tissues in morphological studies. Here, 23Na NMR imaging was used to study the distribution in muscle of brine (5 M NaCl), injected before onset of rigor mortis. First, the distribution of brine was monitored in excised muscle from rabbits for 6 hr followi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92360-4

    authors: Renou JP,Benderbous S,Bielicki G,Foucat L,Donnat JP

    更新日期:1994-01-01 00:00:00

  • Explicit treatment of mutual inductance in eight-column birdcage resonators.

    abstract::A formulation has been developed for the determination of self and mutual inductances in unloaded, eight-column symmetric birdcage coils using their expected resonant mode current patterns and well-known inductance formulas. The average frequency differences between theory and experiment for mode one resonances for ni...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90511-w

    authors: Pascone R,Vullo T,Farrelly J,Cahill PT

    更新日期:1992-01-01 00:00:00

  • On the R2⁎ relaxometry in complex multi-peak multi-Echo chemical shift-based water-fat quantification: Applications to the neuromuscular diseases.

    abstract:PURPOSE:Investigation of the feasibility of the R2⁎ mapping techniques by using latest theoretical models corrected for confounding factors and optimized for signal to noise ratio. THEORY AND METHODS:The improvement of the performance of state of the art magnetic resonance imaging (MRI) relaxometry algorithms is chall...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.08.006

    authors: Siracusano G,La Corte A,Milazzo C,Anastasi GP,Finocchio G,Gaeta M

    更新日期:2017-01-01 00:00:00

  • Evaluation of preprocessing steps to compensate for magnetic field distortions due to body movements in BOLD fMRI.

    abstract::Blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) is currently the dominant technique for non-invasive investigation of brain functions. One of the challenges with BOLD fMRI, particularly at high fields, is compensation for the effects of spatiotemporally varying magnetic field inho...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.07.005

    authors: Barry RL,Williams JM,Klassen LM,Gallivan JP,Culham JC,Menon RS

    更新日期:2010-02-01 00:00:00

  • DUSTER: dynamic contrast enhance up-sampled temporal resolution analysis method.

    abstract::Dynamic contrast enhanced (DCE) MRI using Tofts' model for estimating vascular permeability is widely accepted, yet inter-tissue differences in bolus arrival time (BAT) are generally ignored. In this work we propose a method, incorporating the BAT in the analysis, demonstrating its applicability and advantages in heal...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.014

    authors: Liberman G,Louzoun Y,Artzi M,Nadav G,Ewing JR,Ben Bashat D

    更新日期:2016-05-01 00:00:00

  • A rapid method for the measurement and estimation of CO2 diffusivity in liquid hydrocarbon-saturated porous media using MRI.

    abstract::In this study, magnetic resonance imaging (MRI) was used to dynamically visualize the diffusion process of CO2 in porous media saturated with liquid hydrocarbon. Based on the assumption of semi-infinite media, effective CO2 diffusivity was obtained directly by the nonlinear fitting of one MR profile during the diffusi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.024

    authors: Zhao Y,Chen J,Yang M,Liu Y,Song Y

    更新日期:2016-05-01 00:00:00

  • Neuroprotective effect of agmatine in rats with transient cerebral ischemia using MR imaging and histopathologic evaluation.

    abstract:PURPOSE:This study aimed to further investigate the effects of agmatine on brain edema in the rats with middle cerebral artery occlusion (MCAO) injury using magnetic resonance imaging (MRI) monitoring and biochemical and histopathologic evaluation. MATERIALS AND METHODS:Following surgical induction of MCAO for 90min, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.03.026

    authors: Huang YC,Tzeng WS,Wang CC,Cheng BC,Chang YK,Chen HH,Lin PC,Huang TY,Chuang TJ,Lin JW,Chang CP

    更新日期:2013-09-01 00:00:00

  • Rapid assessment of regional and global left ventricular function using three-dimensional k-t BLAST imaging.

    abstract:OBJECTIVE:To test if three-dimensional (3D) cine spatial frequency-temporal frequency Broad-use Linear Acquisition Speed-up Technique (k-t BLAST) is suitable for rapid evaluation of global and regional left ventricular (LV) functional parameters and to evaluate the influence of gadolinium administration. MATERIALS AND...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.01.027

    authors: Huber S,Muthupillai R,Mojibian H,Cheong B,Kouwenhoven M,Flamm SD

    更新日期:2008-07-01 00:00:00

  • Localization of ischemia in canine hearts using tagged rotated long axis MR images, endocardial surface stretch and wall thickening.

    abstract::Tagged magnetic resonance imaging allows the noninvasive measurement of regional systolic myocardial deformations and helps localize ischemic regions in the left ventricle (LV). The objective of this study was to evaluate the potential accuracy of localizing ischemic regions in the LV using endocardial and epicardial ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00161-6

    authors: Denisova O,Shapiro EP,Weiss JL,Azhari H

    更新日期:1997-01-01 00:00:00

  • Intramuscular adipose tissue determined by T1-weighted MRI at 3T primarily reflects extramyocellular lipids.

    abstract:PURPOSE:The purpose of this study was to assess relationships between intramuscular adipose tissue (IntraMAT) content determined by MRI and intramyocellular lipids (IMCL) and extramyocellular lipids (EMCL) determined by (1)H magnetic resonance spectroscopy ((1)H MRS) or echo intensity determined by B-mode ultrasonograp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.038

    authors: Akima H,Hioki M,Yoshiko A,Koike T,Sakakibara H,Takahashi H,Oshida Y

    更新日期:2016-05-01 00:00:00

  • Complimentary aspects of diffusion imaging and fMRI: II. Elucidating contributions to the fMRI signal with diffusion sensitization.

    abstract::Tissue water molecules reside in different biophysical compartments. For example, water molecules in the vasculature reside for variable periods of time within arteries, arterioles, capillaries, venuoles and veins, and may be within blood cells or blood plasma. Water molecules outside of the vasculature, in the extrav...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2007.02.006

    authors: Mulkern RV,Haker SJ,Maier SE

    更新日期:2007-07-01 00:00:00

  • Liposomal Gd-DTPA: effect of encapsulation on enhancement of hepatoma model by MRI.

    abstract::Liposomes entrapping gadolinium-DTPA (Gd-DTPA) were synthesized from 60 mole percent egg phosphatidylcholine (EPC) and 40 mole percent cholesterol or EPC alone entrapping Gd-DTPA in diameters of 100 and 200 nm. Rats bearing Morris hepatoma in their flanks were imaged by MR pre- and post-contrast with free Gd-DTPA and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90491-8

    authors: Unger EC,MacDougall P,Cullis P,Tilcock C

    更新日期:1989-07-01 00:00:00

  • Three-dimensional magnetic resonance imaging after ultrasonography for assessment of fetal gastroschisis.

    abstract::A 24-year-old woman (Gravida I, Para I) at estimated 32 weeks of pregnancy was referred to our department for evaluation of a suspected fetal gastroschisis. Ultrasound scan revealed multiple loops of dilated bowel outside the fetal abdomen and absence of membrane surrounding the herniated loops of the intestines. Thre...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.006

    authors: Sasaki Y,Miyamoto T,Hidaka Y,Satoh H,Takuma N,Sengoku K,Sugimori H,Inaoka T,Aburano T

    更新日期:2006-02-01 00:00:00

  • Inherent spatial structure in myelin water fraction maps.

    abstract::Myelin water fraction (MWF) images in brain tend to be spatially noisy with unknown or no apparent spatial patterns structure, so values are therefore typically averaged over large white matter (WM) volumes. We investigated the existence of an inherent spatial structure in MWF maps and explored the benefits of examini...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.09.012

    authors: Baumeister TR,Kolind SH,MacKay AL,McKeown MJ

    更新日期:2020-04-01 00:00:00

  • Fast and high-resolution quantitative mapping of tissue water content with full brain coverage for clinically-driven studies.

    abstract::An efficient method for obtaining longitudinal relaxation time (T1) maps is based on acquiring two spoiled gradient recalled echo (SPGR) images in steady states with different flip angles, which has also been extended, with additional acquisitions, to obtain a tissue water content (M0) map. Several factors, including ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.08.001

    authors: Sabati M,Maudsley AA

    更新日期:2013-12-01 00:00:00