Abstract:
:The anticancer effect of thiacarpine, a synthetic analogue of the known cytotoxic alkaloid polycarpine isolated from the Pacific ascidian Polycarpa aurata, was investigated in vivo in experiments using mouse solid Ehrlich carcinoma tumor as the target. A high-resolution magnetic resonance imaging (MRI) technique using a MR tomograph "PharmaScan" US70/16 (Bruker, Ettlingen, Germany) was used for visualization and quantification of tumor size. Fluorescence microscopy and image analysis were applied to determine Ehrlich carcinoma cell chromatin condensing (apoptosis) and necrosis in Ehrlich carcinoma cells at the action of thiacarpine in in vitro experiments. The scan and size calculations of the tumor and some mouse organs were carried out during the experiments. Thiacarpine in a total dose of 100 mg/kg was found to exhibit the delay in growth of the mouse tumor. The antineoplastic effect of this compound was accompanied by an increase in the lifetime of experimental mice in comparison with the control group of animals. Our data show that the ability of thiacarpine to induce apoptosis in carcinoma cells may contribute to thiacarpine anticancer effects against mice solid Ehrlich carcinoma in vivo detected by MRI.
journal_name
Magn Reson Imagingjournal_title
Magnetic resonance imagingauthors
Agafonova IG,Radchenko OS,Novikov VL,Aminin DL,Stonik VAdoi
10.1016/j.mri.2008.01.014subject
Has Abstractpub_date
2008-07-01 00:00:00pages
763-9issue
6eissn
0730-725Xissn
1873-5894pii
S0730-725X(08)00064-7journal_volume
26pub_type
杂志文章abstract::Acetaminophen (APAP) toxicity is responsible for approximately half of all cases of acute liver failure in the United States. The mouse model of APAP toxicity is widely used to examine mechanisms of APAP toxicity. Noninvasive approaches would allow for serial measurements in a single animal to study the effects of exp...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2011.09.023
更新日期:2012-02-01 00:00:00
abstract::The effects of motion in two-dimensional Fourier transform imaging (2DFT) are considered. Specific calculations describing the case of periodic motion are presented. The results predict the commonly seen artifact of image replication, sometimes referred to as ghosting. Expressions for both position and amplitude of th...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(86)91046-5
更新日期:1986-01-01 00:00:00
abstract::The objective of this study was to analyze regional variations of magnetic resonance (MR) relaxation times (T1ρ and T2) in hip joint cartilage of healthy volunteers and subjects with femoral acetabular impingement (FAI). Morphological and quantitative images of the hip joints of 12 healthy volunteers and 9 FAI patient...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.01.009
更新日期:2013-09-01 00:00:00
abstract::Liver fibrosis determines the functional liver reserve. Several studies have reported that the apparent diffusion coefficient (ADC) values of diffusion-weighted magnetic resonance imaging (DW-MRI) can assess liver fibrosis. We investigated whether DW-MRI predicts postoperative hepatic insufficiency and liver fibrosis ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2010.03.018
更新日期:2010-07-01 00:00:00
abstract::Arterial spin labeling (ASL) perfusion fMRI data differ in important respects from the more familiar blood oxygen level-dependent (BOLD) fMRI data and require specific processing strategies. In this paper, we examined several factors that may influence ASL data analysis, including data storage bit resolution, motion c...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.07.003
更新日期:2008-02-01 00:00:00
abstract::Serious adverse reactions following the IV administration of Gd-DTPA (Magnevist, gadopenetate dimeglumine, Berlex Laboratories, Wayne, NJ), although extremely rare, can occur. As yet, there has been no published case of a severe anaphylactoid-type reaction to Gd-DTPA. ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(90)90019-x
更新日期:1990-01-01 00:00:00
abstract::Prostate MRI is an important tool to diagnose and characterize cancer. High local sensitivity and good parallel imaging performance are of paramount importance for diagnostic quality and efficiency. The purpose of this work was to evaluate stacked resonators as part of a surface receiver array for prostate MRI at 3 Te...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2018.07.010
更新日期:2018-11-01 00:00:00
abstract::The effects of bone on marrow relaxation in the trabecular volume of the most proximal 3 cm in the left tibia were studied with a RF-spoiled gradient echo MRI protocol on a 1.0 T MR unit. The MR measurements were performed on six healthy volunteers, and repeated within one month in order to assess the precision of the...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00159-3
更新日期:1999-01-01 00:00:00
abstract:PURPOSE:The purpose of this study was to determine the pre- and postpubertal 1H magnetic resonance spectroscopic characteristics of the normal testis to establish baseline values for further clinical studies. MATERIALS AND METHODS:The subjects consisted of male volunteers, of whom 19 were prepubertal with ages between...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.06.008
更新日期:2008-02-01 00:00:00
abstract::Fast magnetic resonance (MR) imaging provides a consistent and predictable appearance of vascular abnormalities as shown by four patients with thrombi, dissection and aneurysm. Fast MR images are obtained during breath-holding, resulting in an absence of respiratory motion artifacts. The time of MR study is much less ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(88)90483-3
更新日期:1988-07-01 00:00:00
abstract::Quantitative longitudinal brain magnetic resonance (MR) studies may be confounded by scanner-related drifts in voxel sizes. Total intracranial volume (TIV) normalisation is commonly used to correct serial cerebral volumetric measurements for these drifts. We hypothesised that automated rigid-body registration of whole...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2004.01.057
更新日期:2004-09-01 00:00:00
abstract::The purpose of this study was to evaluate the diagnostic potential of a high-resolution magnetic resonance (MR) venography technique in patients with cerebral arteriovenous malformations (AVMs). A high-resolution 3D gradient echo sequence was used with a long echo time TE to obtain venous information down to sub-pixel...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(99)00084-3
更新日期:1999-12-01 00:00:00
abstract::In this retrospective study we tested the hypothesis that the net effect of impaired electrical conduction and therefore increased heat dissipation in multiple sclerosis (MS) results in elevated lateral ventricular (LV) cerebrospinal fluid (CSF) diffusivity as a measure of brain temperature estimated in vivo using dif...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.11.002
更新日期:2015-04-01 00:00:00
abstract::It has been shown recently that quantitative T2-maps may be measured by acquisition of a series of at least eight T2-weighted SNAPSHOT FLASH images. These measurements require a relaxation delay of 10-15 s after each T2-weighted image for the complete relaxation of the spin system. This results in long measuring times...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(95)00004-z
更新日期:1995-01-01 00:00:00
abstract::We compared the ability of magnetic resonance imaging (MRI) using a 0.064 T permanent magnet, three-phase bone scanning, and indium-labeled white blood cell (111In-WBC) scanning, to diagnose osteomyelitis. Twenty-three patients underwent biopsy. All patients were examined at presentation with all three modalities. Sen...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(91)90540-3
更新日期:1991-01-01 00:00:00
abstract:OBJECTIVE:To perform non-enhanced (NE) magnetic resonance imaging (MRI) of the small bowel at 7 Tesla (7T) and to compare it with 1.5 Tesla (1.5T). MATERIAL AND METHODS:Twelve healthy subjects were prospectively examined using a 1.5T and 7T MRI system. Coronal and axial true fast imaging with steady-state precession (...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2015.11.012
更新日期:2016-06-01 00:00:00
abstract::Dynamic and static gadolinium-diethylenetriaminepentaacetic acid(Gd-DTPA)-enhanced magnetic resonance imaging (MRI) were evaluated as measures of joint inflammation in arthritis, by a comparison with macroscopic and microscopic signs of synovitis. Furthermore, the importance of the size of the evaluated synovial areas...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00008-3
更新日期:1998-09-01 00:00:00
abstract::In independent component analysis (ICA), principal component analysis (PCA) is generally used to reduce the raw data to a few principal components (PCs) through eigenvector decomposition (EVD) on the data covariance matrix. Although this works for spatial ICA (sICA) on moderately sized fMRI data, it is intractable for...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2005.12.013
更新日期:2006-06-01 00:00:00
abstract::The CNS involvement is frequently found in human immunodeficiency virus (HIV) infection. The purpose of our study was to determine whether proton magnetic resonance spectroscopy (MRS) could detect early brain involvement in neurologically asymptomatic HIV-infected patients with normal MR imagings and to find the corre...
journal_title:Magnetic resonance imaging
pub_type: 临床试验,杂志文章
doi:10.1016/s0730-725x(00)00173-9
更新日期:2000-09-01 00:00:00
abstract:OBJECTIVE:In magnetic resonance-guided breast vacuum biopsies, the contrast agent for targeting suspicious lesions can typically be applied only once during an intervention, due to the slow elimination of the gadolinium chelate from the extracellular fluid space. This study evaluated the feasibility of diffusion-weight...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.12.006
更新日期:2017-05-01 00:00:00
abstract::White matter loss, ventricular enlargement and white matter lesions are common findings on brain scans of older subjects. Accurate assessment of these different features is therefore essential for normal aging research. Recently, we developed a novel unsupervised classification method, named 'Multispectral Coloring Mo...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2011.09.016
更新日期:2012-02-01 00:00:00
abstract::We implemented pseudo-continuous ASL (pCASL) with 2D and 3D balanced steady state free precession (bSSFP) readout for mapping blood flow in the human brain, retina, and kidney, free of distortion and signal dropout, which are typically observed in the most commonly used echo-planar imaging acquisition. High resolution...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.03.024
更新日期:2013-09-01 00:00:00
abstract::Hippocampal metabolite concentrations were determined by localized in vivo proton magnetic resonance spectroscopy (1H MRS) in eleven patients suffering from refractory mesial temporal lobe epilepsy (MTLE), as well as in eleven age-matched healthy volunteers, and compared with patient history, postoperative outcome and...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00123-4
更新日期:1998-10-01 00:00:00
abstract:PURPOSE:The purpose was to validate diffusion-weighted imaging (DWI) in the assessment of hepatic metastases compared with superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance imaging. MATERIALS AND METHODS:For 21 consecutive patients with 160 metastases from extrahepatic malignancy and 25 benign focal lesi...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2011.12.007
更新日期:2012-05-01 00:00:00
abstract::Various analogs of NMR and MRI are now technically possible in optics; specifically, high-resolution laser-pulse shaping and complex pulse sequence generation with well-defined phase shifts has been demonstrated. Here we summarize this technology and discuss the potential for these methods to enhance optical functiona...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2003.08.024
更新日期:2003-12-01 00:00:00
abstract::The advantages of event-related functional Magnetic Resonance Imaging (fMRI) and the increasing use of fMRI in cognitive experiments are both driving the development of techniques that allow images sensitive to the blood oxygen level-dependent effect to be acquired at ever-higher temporal resolution. Here, we present ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2005.12.030
更新日期:2006-05-01 00:00:00
abstract::Surface magnetic relaxation in porous media is usually attributed to hindered rotation or to paramagnetic impurities on the surface. In cement pastes, however, it seems reasonable to attribute surface relaxation to dipole interactions in water adsorbed as water of hydration on grain surfaces. The rate limiting factor ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)91517-2
更新日期:1994-01-01 00:00:00
abstract::Merkel cell carcinoma (MCC) is a rare malignant tumor of the skin and often is diagnosed histologically as lymphoma, melanoma and even metastatic small cell carcinoma of the lung (SCCL). Classified as a neuroendocrine tumor, clinically it originates in the head and neck region and may present with metastatic disease a...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(00)00176-4
更新日期:2000-10-01 00:00:00
abstract::The purpose of this study was to demonstrate the initial results of the dynamic contrast-enhanced MRA in under four seconds in the assessment of anomalous pulmonary circulation. We performed dynamic contrast enhanced MRA on ten patients with a temporal resolution of 2-3 sec for each phase. Five patients had pulmonary ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(02)00634-3
更新日期:2003-01-01 00:00:00
abstract::NMR spectroscopy is applied to study microstructure of calcium silicate hydrates present in cement and concrete. It is shown that 29Si NMR gives information on the siliceous skeleton of the hydrates. 1H NMR, using CRAMPS techniques, allows to discriminate between protons linked to silicon atoms or to calcium atoms. A ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(96)00211-1
更新日期:1996-01-01 00:00:00