The prospects for high resolution optical brain imaging: the magnetic resonance perspective.

Abstract:

:Various analogs of NMR and MRI are now technically possible in optics; specifically, high-resolution laser-pulse shaping and complex pulse sequence generation with well-defined phase shifts has been demonstrated. Here we summarize this technology and discuss the potential for these methods to enhance optical functional imaging, competing with (and surpassing?) what is possible by functional MRI.

journal_name

Magn Reson Imaging

authors

Warren WS,Wagner W,Ye T

doi

10.1016/j.mri.2003.08.024

subject

Has Abstract

pub_date

2003-12-01 00:00:00

pages

1225-33

issue

10

eissn

0730-725X

issn

1873-5894

pii

S0730725X03003345

journal_volume

21

pub_type

杂志文章
  • Spine MR images in patients with pedicle screw fixation: Comparison of conventional and SEMAC-VAT sequences at 1.5 T.

    abstract:BACKGROUND AND PURPOSE:Slice-encoding metal artifact corrections (SEMAC)-view-angle tilting (VAT) sequences have recently been used in clinical protocols to reduce metal artifacts in MR scans of patients with spinal instrumentation. The objective of this study was to compare the SEMAC-VAT sequence with the conventional...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.08.002

    authors: Park C,Lee E,Yeo Y,Kang Y,Lee JW,Ahn JM,Kang HS

    更新日期:2018-12-01 00:00:00

  • Error propagation model for microscopic magnetic resonance elastography shear-wave images.

    abstract::Microscopic magnetic resonance elastography is a high-resolution method for visualizing shear waves and assessing the biomechanical viscoelastic properties of small biological samples. In this work, we used error propagation to develop a simple analytical model that relates the signal-to-noise ratio of MR magnitude im...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.09.040

    authors: Othman SF,Zhou XJ,Xu H,Royston TJ,Magin RL

    更新日期:2007-01-01 00:00:00

  • A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI. Part 1: Development of a computational method.

    abstract::Articular cartilage thickness is of relevance in various fields in diagnostics and biomedical research. In view of recent improvements of MR cartilage imaging a computational method has been developed for three-dimensional determination of cartilage thickness from tomographic datasets. A correction algorithm that comp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00012-x

    authors: Lösch A,Eckstein F,Haubner M,Englmeier KH

    更新日期:1997-01-01 00:00:00

  • Evaluation of preprocessing steps to compensate for magnetic field distortions due to body movements in BOLD fMRI.

    abstract::Blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) is currently the dominant technique for non-invasive investigation of brain functions. One of the challenges with BOLD fMRI, particularly at high fields, is compensation for the effects of spatiotemporally varying magnetic field inho...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.07.005

    authors: Barry RL,Williams JM,Klassen LM,Gallivan JP,Culham JC,Menon RS

    更新日期:2010-02-01 00:00:00

  • Neurophysiological and functional MRI evidence of reorganization of cortical motor areas in cerebral arteriovenous malformation.

    abstract::Functional magnetic resonance imaging (fMRI) research has shown that brain arteriovenous malformations (AVMs) lead to reorganization of cortical motor areas. Since it is known that blood oxygenation level-dependent signal in fMRI may be influenced by the hemodynamic perturbation associated with the presence of the AVM...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.029

    authors: Caramia F,Francia A,Mainero C,Tinelli E,Palmieri MG,Colonnese C,Bozzao L,Caramia MD

    更新日期:2009-12-01 00:00:00

  • Segmented diffusion-weighted imaging of the prostate: Application to transperineal in-bore 3T MR image-guided targeted biopsy.

    abstract:OBJECTIVE:This study aims to evaluate the applicability of using single-shot and multi-shot segmented diffusion-weighted imaging (DWI) techniques to support biopsy target localization in a cohort of targeted MRI-guided prostate biopsy patients. MATERIALS AND METHODS:Single-shot echo-planar diffusion-weighted imaging (...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.05.012

    authors: Fedorov A,Tuncali K,Panych LP,Fairhurst J,Hassanzadeh E,Seethamraju RT,Tempany CM,Maier SE

    更新日期:2016-10-01 00:00:00

  • In situ magnetic resonance measurement of conversion, hydrodynamics and mass transfer during single- and two-phase flow in fixed-bed reactors.

    abstract::In recent years there has been increasing interest in applying magnetic resonance (MR) techniques in areas of engineering and chemical technology. The science that underpins many of these applications is the physics and chemistry of transport and reaction processes in porous materials. Key to the exploitation of MR me...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00127-9

    authors: Gladden LF,Alexander P,Britton MM,Mantle MD,Sederman AJ,Yuen EH

    更新日期:2003-04-01 00:00:00

  • Alterations in diffusion properties of white matter in Williams syndrome.

    abstract::Diffusion tensor imaging (DTI) was used to investigate the involvement of brain white matter in Williams syndrome (WS), a genetic neurodevelopmental disorder. Whole-brain DTIs were obtained from 16 young adults with WS and 16 normal controls. A voxel-based analysis was performed to compare fractional anisotropy (FA) v...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.07.012

    authors: Arlinghaus LR,Thornton-Wells TA,Dykens EM,Anderson AW

    更新日期:2011-11-01 00:00:00

  • Controlled delivery of Gd-containing liposomes to lymph nodes: surface modification may enhance MRI contrast properties.

    abstract::Surface modification of liposomes containing Gd-diethylenetriaminepentaacetyl-phosphatidylethanolamine (Gd-DTPA-PE) as an amphiphilic paramagnetic label influences their contrast properties as MRI agents. Liposomes with the mean diameter ca. 220 nm and 10% mol content of Gd-DTPA-PE were modified with dextran (molecula...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)00083-f

    authors: Trubetskoy VS,Cannillo JA,Milshtein A,Wolf GL,Torchilin VP

    更新日期:1995-01-01 00:00:00

  • Inherent spatial structure in myelin water fraction maps.

    abstract::Myelin water fraction (MWF) images in brain tend to be spatially noisy with unknown or no apparent spatial patterns structure, so values are therefore typically averaged over large white matter (WM) volumes. We investigated the existence of an inherent spatial structure in MWF maps and explored the benefits of examini...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.09.012

    authors: Baumeister TR,Kolind SH,MacKay AL,McKeown MJ

    更新日期:2020-04-01 00:00:00

  • Electric stimulation fMRI of the perforant pathway to the rat hippocampus.

    abstract::The hippocampal formation is a brain system that is implicated in learning and memory. The major input to the hippocampus arrives from the entorhinal cortex (EC) to the dentate gyrus (DG) through the perforant path. In the present work, we have investigated the functional properties of this connection by concomitantly...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.02.018

    authors: Canals S,Beyerlein M,Murayama Y,Logothetis NK

    更新日期:2008-09-01 00:00:00

  • Fast acceleration of ASL-based time-resolved magnetic resonance angiography by acquisition of control and labeled images in the same shot (fast ACTRESS): An optimization study.

    abstract:PURPOSE:To establish an optimized sequence design for fast acceleration of arterial spin labeling (ASL)-based time-resolved magnetic resonance angiography (MRA) by acquisition of control and labeled images in the same shot (fast ACTRESS) and a scan time of <1min, for the evaluation of intracranial vessels. MATERIALS A...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.07.026

    authors: Sugimori H,Fujima N,Suzuki Y,Hamaguchi H,Ishizaka K,Kudo K

    更新日期:2017-11-01 00:00:00

  • Quantitative 1H MRS in the evaluation of mesial temporal lobe epilepsy in vivo.

    abstract::Hippocampal metabolite concentrations were determined by localized in vivo proton magnetic resonance spectroscopy (1H MRS) in eleven patients suffering from refractory mesial temporal lobe epilepsy (MTLE), as well as in eleven age-matched healthy volunteers, and compared with patient history, postoperative outcome and...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00123-4

    authors: Duc CO,Trabesinger AH,Weber OM,Meier D,Walder M,Wieser HG,Boesiger P

    更新日期:1998-10-01 00:00:00

  • The comparison of the performance of 3 T and 7 T T2 mapping for untreated low-grade cartilage lesions.

    abstract:OBJECTIVE:To investigate T2 mapping as a possible marker for low-grade human articular cartilage lesions during a one-year follow-up, possible changes during the follow-up and compare the reliability and sensitivity of these measurements on high-field (3 T) and ultra-high-field (7 T) MRI scanners. DESIGN:Twenty-one pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.09.021

    authors: Juras V,Schreiner M,Laurent D,Zbýň Š,Mlynarik V,Szomolanyi P,Hager B,Scotti C,Goldhahn J,Heule R,Bieri O,Trattnig S

    更新日期:2019-01-01 00:00:00

  • Summary of special issue on gadolinium bioeffects and toxicity with a look to the future.

    abstract::This summary attempts to provide forward-looking concepts regarding gadolinium related toxicity, as discussed in further detail in this issue. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2016.09.002

    authors: Semelka RC,Ramalho M,Jay M

    更新日期:2016-12-01 00:00:00

  • Assessment of extravascular extracellular space fraction in human melanoma xenografts by DCE-MRI and kinetic modeling.

    abstract::Tumor aggressiveness and response to therapy are influenced by the extravascular extracellular space fraction (EESF) of the malignant tissue. The EESF may, therefore, be an important prognostic parameter for cancer patients. The aim of this study was to investigate whether gadopentetate dimeglumine (Gd-DTPA)-based dyn...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.06.003

    authors: Benjaminsen IC,Brurberg KG,Ruud EB,Rofstad EK

    更新日期:2008-02-01 00:00:00

  • In vivo nuclear magnetic resonance imaging and spectroscopy of aquatic organisms.

    abstract::NMR imaging and localized 1H spectroscopy of a variety of aquatic organisms in vivo is described for the first time. The practical consideration of life support, water volume, salinity, and anesthesia are discussed and solutions presented. Such animal studies shape our understanding of physiology, biochemistry, and bi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90253-x

    authors: Blackband SJ,Stoskopf MK

    更新日期:1990-01-01 00:00:00

  • Combination of integrated dynamic shimming and readout-segmented echo planar imaging for diffusion weighted MRI of the head and neck region at 3Tesla.

    abstract:PURPOSE:To evaluate the performance of combined integrated slice-by-slice shimming and readout-segmented EPI (irsEPI) for diffusion-weighted MR imaging (DWI) of the neck at 3Tesla. METHODS:This study was approved by the local ethics committee. An anthropometric phantom of the head/neck region incorporating compartment...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.05.004

    authors: Walter SS,Liu W,Stemmer A,Martirosian P,Nikolaou K,Notohamiprodjo M,Gatidis S

    更新日期:2017-10-01 00:00:00

  • MRI of the anal canal: correlation with histologic examination.

    abstract::The purpose of this study was to correlate the MRI features of the anal canal with histologic findings. T1- and T2-weighted MR images of nine anal canals were obtained after fixation in 10% formalin. In three specimens, imaging was repeated after removal of histologic layers with a dissecting microscope. Corresponding...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02056-y

    authors: Van Beers BE,Kartheuser A,Delos MA,Grandin C,Detry R,Jamart J,Pringot J

    更新日期:1996-01-01 00:00:00

  • Functional MR imaging in the awake monkey: effects of motion on dynamic off-resonance and processing strategies.

    abstract::Functional MR imaging of the alert, behaving monkey is being used more and more often to detect activation patterns and guide electrophysiological research investigating the neural basis of behavior. Several labs have reported fMRI data from the awake monkey, but none of them has studied and systematically corrected t...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.002

    authors: Pfeuffer J,Shmuel A,Keliris GA,Steudel T,Merkle H,Logothetis NK

    更新日期:2007-07-01 00:00:00

  • Influence of excess ligand on Nephrogenic Systemic Fibrosis associated with nonionic, linear gadolinium-based contrast agents.

    abstract:BACKGROUND:The molecular structure, charge, thermodynamic and kinetic stability are approximately the same for gadodiamide and gadoversetamide, the main substantive difference is that gadodiamide is manufactured with 5% free ligand to form Omniscan® and gadoversetamide with 10% free ligand to form OptiMARK®. PURPOSE:T...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.11.015

    authors: Semelka RC,Prybylski JP,Ramalho M

    更新日期:2019-05-01 00:00:00

  • Ultrashort echo (UTE) versus pointwise encoding time reduction with radial acquisition (PETRA) sequences at 3 Tesla for knee meniscus: A comparative study.

    abstract:PURPOSE:The purposes of this study were to (1) correlate the ultrashort echo time (TE) signal intensity of the pointwise encoding time reduction with radial acquisition (PETRA) sequence with that of the ultrashort echo (UTE) sequence using in vivo meniscal ultrashort TE imaging of the knee with a 3-Tesla (3T) clinical ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.09.003

    authors: Lee YH,Suh JS,Grodzki D

    更新日期:2016-02-01 00:00:00

  • Issues about the fMRI of the human spinal cord.

    abstract::Noninvasive functional studies on human spinal cord by means of magnetic resonance imaging (MRI) are gaining attention because of the promising applications in the study of healthy and injured central nervous system. The findings obtained are generally consistent with the anatomic knowledge based on invasive methods, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.10.015

    authors: Giove F,Garreffa G,Giulietti G,Mangia S,Colonnese C,Maraviglia B

    更新日期:2004-12-01 00:00:00

  • Complimentary aspects of diffusion imaging and fMRI: II. Elucidating contributions to the fMRI signal with diffusion sensitization.

    abstract::Tissue water molecules reside in different biophysical compartments. For example, water molecules in the vasculature reside for variable periods of time within arteries, arterioles, capillaries, venuoles and veins, and may be within blood cells or blood plasma. Water molecules outside of the vasculature, in the extrav...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2007.02.006

    authors: Mulkern RV,Haker SJ,Maier SE

    更新日期:2007-07-01 00:00:00

  • Reproducibility of MRI-derived measurements of right ventricular volumes and myocardial mass.

    abstract::Magnetic resonance (MR) imaging has been shown to provide accurate measurements of right ventricular (RV) volumes and myocardial mass. The purpose of this study was to evaluate the reproducibility of MR imaging, which in clinical practice may be as important as its absolute accuracy. The reproducibility of MR imaging ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)00076-f

    authors: Pattynama PM,Lamb HJ,Van der Velde EA,Van der Geest RJ,Van der Wall EE,De Roos A

    更新日期:1995-01-01 00:00:00

  • Simultaneous optimization of power and duration of radio-frequency pulse in PARACEST MRI.

    abstract::Chemical exchange saturation transfer (CEST) MRI is increasingly used to probe mobile proteins and microenvironment properties, and shows great promise for tumor and stroke diagnosis. The CEST effect is complex and depends not only on the CEST agent concentration, exchange rates, the characteristic of the magnetizatio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.02.001

    authors: Rezaeian MR,Hossein-Zadeh GA,Soltanian-Zadeh H

    更新日期:2016-07-01 00:00:00

  • Lee-Goldburg solid-state imaging.

    abstract::A new approach to solid-state imaging (SSI) is presented. The method relies on narrowing the resonance line using the Lee-Goldburg sequence. The technique is easy to implement in practice and may find widespread applications in materials science. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90409-s

    authors: De Luca F,Lugeri N,De Simone BC,Maraviglia B

    更新日期:1992-01-01 00:00:00

  • Optimal real-time estimation in diffusion tensor imaging.

    abstract::Diffusion tensor imaging (DTI) constitutes the most used paradigm among the diffusion-weighted magnetic resonance imaging (DW-MRI) techniques due to its simplicity and application potential. Recently, real-time estimation in DW-MRI has deserved special attention, with several proposals aiming at the estimation of mean...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.12.001

    authors: Casaseca-de-la-Higuera P,Tristán-Vega A,Aja-Fernández S,Alberola-López C,Westin CF,San José Estépar R

    更新日期:2012-05-01 00:00:00

  • Artificial intelligence in medical imaging.

    abstract::The medical specialty radiology has experienced a number of extremely important and influential technical developments in the past that have affected how medical imaging is deployed. Artificial intelligence (AI) is potentially another such development that will introduce fundamental changes into the practice of radiol...

    journal_title:Magnetic resonance imaging

    pub_type: 社论

    doi:10.1016/j.mri.2019.12.006

    authors: Gore JC

    更新日期:2020-05-01 00:00:00

  • Simultaneous recording of neuronal signals and functional NMR imaging.

    abstract::We recently directly examined the relationship between blood-oxygen-level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signals and neural activity by simultaneously acquiring electrophysiological and fMRI data from monkeys in a 4.7-T vertical scanner (Logothetis NK, Pauls J, Augath MA, Trinath T, Oelt...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.015

    authors: Oeltermann A,Augath MA,Logothetis NK

    更新日期:2007-07-01 00:00:00