Severe anaphylactoid reaction after i.v. Gd-DTPA.

Abstract:

:Serious adverse reactions following the IV administration of Gd-DTPA (Magnevist, gadopenetate dimeglumine, Berlex Laboratories, Wayne, NJ), although extremely rare, can occur. As yet, there has been no published case of a severe anaphylactoid-type reaction to Gd-DTPA.

journal_name

Magn Reson Imaging

authors

Weiss KL

doi

10.1016/0730-725x(90)90019-x

subject

Has Abstract

pub_date

1990-01-01 00:00:00

pages

817-8

issue

6

eissn

0730-725X

issn

1873-5894

pii

0730-725X(90)90019-X

journal_volume

8

pub_type

杂志文章
  • Fast and exact flow measurements with the fast Fourier flow technique.

    abstract::The fast Fourier flow technique offers a convenient way for extremely exact flow measurements. In combination with ECG gating, arterial flow can be studied. The total acquisition time for a single measurement is about 10 s, an ECG-gated cine sequence can be acquired in about 4 min. Fast Fourier flow can, therefore, be...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90473-0

    authors: Hennig J,Mueri M,Brunner P,Friedburg H

    更新日期:1988-07-01 00:00:00

  • MR microscopy of micron scale structures.

    abstract::Magnetic resonance (MR) microscopy of up to 1-5-microm resolutions have been reported previously. The tested phantom structures, however, had widths one order of magnitude bigger than the reported resolutions, e.g., spherical beads or capillary tubes of tens-of-micron diameters or wall thicknesses have been imaged. In...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.01.002

    authors: Lee SC,Kim K,Kim J,Yi JH,Lee S,Cheong C

    更新日期:2009-07-01 00:00:00

  • SSFP fMRI at 3 tesla: Efficiency of polar acquisition-reconstruction technique.

    abstract::SSFP-based fMRI techniques, known for their high specificity and low geometrical distortion, look promising for high-resolution brain mapping. Nevertheless, they suffer from lack of speed and sensitivity, leading them to be exploited mostly in high-field scanners. Radial acquisition can help with these inefficiencies ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.09.005

    authors: Malekian V,Rastegar F,Shafieizargar B,Nasiraei-Moghaddam A

    更新日期:2020-12-01 00:00:00

  • Dual-acquisition phase-sensitive fat-water separation using balanced steady-state free precession.

    abstract::Balanced steady-state free precession (SSFP) sequences use fully re-focussed gradient waveforms to achieve a high signal and useful image contrast in short scan times. Despite these strengths, the clinical feasibility of balanced SSFP is still limited both by bright fat signal and by the signal voids that result from ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.013

    authors: Hargreaves BA,Bangerter NK,Shimakawa A,Vasanawala SS,Brittain JH,Nishimura DG

    更新日期:2006-02-01 00:00:00

  • Biodistribution of GdCl3 and Gd-DTPA and their influence on proton magnetic relaxation in rat tissues.

    abstract::The biodistribution and relative molar effectiveness of the ionic (GdCl3) and chelated (Gd-DTPA) forms of gadolinium (Gd) to enhance proton relaxation rates in rat kidney, liver and spleen were evaluated. Rats were given intravenous injections of either GdCl3 (100 mumol/kg) or Gd-DTPA (178 mumol/kg). Gd-DTPA was prima...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90023-3

    authors: Barnhart JL,Kuhnert N,Bakan DA,Berk RN

    更新日期:1987-01-01 00:00:00

  • Simultaneous optimization of power and duration of radio-frequency pulse in PARACEST MRI.

    abstract::Chemical exchange saturation transfer (CEST) MRI is increasingly used to probe mobile proteins and microenvironment properties, and shows great promise for tumor and stroke diagnosis. The CEST effect is complex and depends not only on the CEST agent concentration, exchange rates, the characteristic of the magnetizatio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.02.001

    authors: Rezaeian MR,Hossein-Zadeh GA,Soltanian-Zadeh H

    更新日期:2016-07-01 00:00:00

  • Computerized MRS voxel registration and partial volume effects in single voxel 1H-MRS.

    abstract::Partial volume effects in proton magnetic resonance spectroscopy in the brain have been studied previously in terms of proper water concentration calculations, but there is a lack of disclosure in terms of voxel placement techniques that would affect the calculations. The purpose of this study is to facilitate a fully...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.04.001

    authors: Lee H,Caparelli E,Li H,Mandal A,Smith SD,Zhang S,Bilfinger TV,Benveniste H

    更新日期:2013-09-01 00:00:00

  • Tissue sodium concentration and sodium T1 mapping of the human brain at 3 T using a Variable Flip Angle method.

    abstract:PURPOSE:The state-of-the-art method to quantify sodium concentrations in vivo consists in a fully relaxed 3D spin-density (SD) weighted acquisition. Nevertheless, most sodium MRI clinical studies use short-TR SD acquisitions to reduce acquisition durations. We present a clinically viable implementation of the Variable ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.01.015

    authors: Coste A,Boumezbeur F,Vignaud A,Madelin G,Reetz K,Le Bihan D,Rabrait-Lerman C,Romanzetti S

    更新日期:2019-05-01 00:00:00

  • Multicontrast multiecho FLASH MRI for targeting the subthalamic nucleus.

    abstract::The subthalamic nucleus (STN) is one of the most common stimulation targets for treating Parkinson's disease using deep brain stimulation (DBS). This procedure requires precise placement of the stimulating electrode. Common practice of DBS implantation utilizes microelectrode recording to locate the sites with the cor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.02.006

    authors: Xiao Y,Beriault S,Pike GB,Collins DL

    更新日期:2012-06-01 00:00:00

  • Effect of off-frequency sampling in magnetic resonance elastography.

    abstract::In magnetic resonance elastography (MRE), shear waves at a certain frequency are encoded through bipolar gradients that switch polarity at a controlled encoding frequency and are offset in time to capture wave propagation using a controlled sampling frequency. In brain MRE, there is a possibility that the mechanical a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.09.017

    authors: Johnson CL,Chen DD,Olivero WC,Sutton BP,Georgiadis JG

    更新日期:2012-02-01 00:00:00

  • High density barium sulphate as an MRI oral contrast.

    abstract::High density barium sulphate suspension was investigated as an oral contrast on MRI. On 30 consecutive subjects, the stomach (in all cases) and the two first portions of the duodenum (in 21 cases) were filled with the suspension. This oral contrast behaved as a negative contrast, being hypointense on all pulse sequenc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90019-i

    authors: Marti-Bonmati L,Vilar J,Paniagua JC,Talens A

    更新日期:1991-01-01 00:00:00

  • Spine MR images in patients with pedicle screw fixation: Comparison of conventional and SEMAC-VAT sequences at 1.5 T.

    abstract:BACKGROUND AND PURPOSE:Slice-encoding metal artifact corrections (SEMAC)-view-angle tilting (VAT) sequences have recently been used in clinical protocols to reduce metal artifacts in MR scans of patients with spinal instrumentation. The objective of this study was to compare the SEMAC-VAT sequence with the conventional...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.08.002

    authors: Park C,Lee E,Yeo Y,Kang Y,Lee JW,Ahn JM,Kang HS

    更新日期:2018-12-01 00:00:00

  • Magnetic resonance in the era of molecular imaging of cancer.

    abstract::Magnetic resonance imaging (MRI) has played an important role in the diagnosis and management of cancer since it was first developed, but other modalities also continue to advance and provide complementary information on the status of tumors. In the future, there will be a major continuing role for noninvasive imaging...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2011.02.003

    authors: Gore JC,Manning HC,Quarles CC,Waddell KW,Yankeelov TE

    更新日期:2011-06-01 00:00:00

  • The prospects for high resolution optical brain imaging: the magnetic resonance perspective.

    abstract::Various analogs of NMR and MRI are now technically possible in optics; specifically, high-resolution laser-pulse shaping and complex pulse sequence generation with well-defined phase shifts has been demonstrated. Here we summarize this technology and discuss the potential for these methods to enhance optical functiona...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.08.024

    authors: Warren WS,Wagner W,Ye T

    更新日期:2003-12-01 00:00:00

  • Cardiac magnetic resonance tissue tracking in right ventricle: Feasibility and normal values.

    abstract:PURPOSE:To investigate right ventricular (RV) strain in patients without identified cardiac pathology using cardiac magnetic resonance tissue tracking (CMR TT). METHODS:A total of 50 consecutive patients with no identified cardiac pathology were analyzed. RV longitudinal and circumferential strain was assessed by CMR ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.01.007

    authors: Truong VT,Safdar KS,Kalra DK,Gao X,Ambach S,Taylor MD,Moore R,Taylor RJ,Germann J,Toro-Salazar O,Jefferies JL,Bartone C,Raman SV,Ngo T,Mazur W

    更新日期:2017-05-01 00:00:00

  • A comparison of readout segmented EPI and interleaved EPI in high-resolution diffusion weighted imaging.

    abstract:PURPOSE:To provide a comprehensive understanding of multi-shot EPI diffusion imaging methods by comparing Readout segmented EPI (RS-EPI) and interleaved EPI (iEPI). MATERIALS AND METHODS:RS-EPI and iEPI were compared on the same 3T scanner. A 2D navigator was used for both RS-EPI and iEPI for phase correction. Signal ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.11.011

    authors: Wang Y,Ma X,Zhang Z,Dai E,Jeong HK,Xie B,Yuan C,Guo H

    更新日期:2018-04-01 00:00:00

  • Off-resonance binomial preparatory pulse technique for high sensitivity MRI of H2O17.

    abstract::H2O17 is a freely diffusible tracer and naturally occurring isotope of O16 detectable by MRI and has been shown to be useful for assessing cerebral perfusion in animal studies using direct and indirect MR detection techniques. However, earlier MR techniques are either not sensitive to changes in small concentrations o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.09.005

    authors: Sood R

    更新日期:2004-02-01 00:00:00

  • Quantitative susceptibility mapping of prostate with separate calculations for water and fat regions for reducing shading artifacts.

    abstract::We propose a novel processing method for reducing shading artifacts in quantitative susceptibility mapping (QSM) for prostate imaging. In the conventional method, calculation errors in the boundary regions between water and fat cause shading artifacts that degrade the image quality for QSM. In the proposed method, wat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.11.006

    authors: Sato R,Shirai T,Soutome Y,Bito Y,Ochi H

    更新日期:2020-02-01 00:00:00

  • The use of Gd-DOTA in magnetic resonance imaging of experimentally induced mammary tumors.

    abstract::Gd-DOTA contrast enhancement of MR images was evaluated on induced mammary tumors in female rats. A single intravenous injection of the carcinogenic N-nitrosourea ENU was administered to Wistar rats; this simple treatment led to a high percentage of mammary tumors without causing death. All the induced tumors were ade...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90215-n

    authors: Bonnet PA,Michel A,Fernandez JP,Cyteval C,Rifai A,Boucard M,Chapat JP,Lamarque JL

    更新日期:1990-01-01 00:00:00

  • Frequency-specific SSFP for hyperpolarized ¹³C metabolic imaging at 14.1 T.

    abstract::Metabolic imaging of hyperpolarized [1-(13)C] pyruvate co-polarized with [(13)C]urea by dynamic nuclear polarization with rapid dissolution is a promising new method for assessing tumor metabolism and perfusion simultaneously in vivo. Novel pulse sequences are required to enable dynamic imaging of multiple (13)C spect...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.037

    authors: von Morze C,Sukumar S,Reed GD,Larson PE,Bok RA,Kurhanewicz J,Vigneron DB

    更新日期:2013-02-01 00:00:00

  • Three dimensional texture analysis in MRI: a preliminary evaluation in gliomas.

    abstract::The discrimination of tumor boundaries from normal tissue, as well as the evaluation of tissue heterogeneity and tumor grading often continue to pose a challenge in MRI. Although yielding promising results in various fields of medical imaging, two- dimensional (2D) texture analysis in MRI has, until now, demonstrated ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00201-7

    authors: Mahmoud-Ghoneim D,Toussaint G,Constans JM,de Certaines JD

    更新日期:2003-11-01 00:00:00

  • Simple phase method for measurement of magnetic field gradient waveforms.

    abstract::Magnetic field gradients play a fundamental role in MR imaging and localized spectroscopy. The MRI experiment, in particular fast MRI, relies on precise gradient switching, which has become more demanding with the constantly growing number of fast imaging techniques. Here we present a simple MR method to measure the b...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.02.002

    authors: Latta P,Gruwel ML,Volotovskyy V,Weber MH,Tomanek B

    更新日期:2007-11-01 00:00:00

  • Assessment of cardiac iron by MRI susceptometry and R2* in patients with thalassemia.

    abstract::A magnetic resonance imaging cardiac magnetic susceptometry (MRI-CS) technique for assessing cardiac tissue iron concentration based on phase mapping was developed. Normal control subjects (n=9) and thalassemia patients (n=13) receiving long-term blood transfusion therapy underwent MRI-CS and MRI measurements of the c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.12.001

    authors: Wang ZJ,Fischer R,Chu Z,Mahoney DH Jr,Mueller BU,Muthupillai R,James EB,Krishnamurthy R,Chung T,Padua E,Vichinsky E,Harmatz P

    更新日期:2010-04-01 00:00:00

  • Diffusion-weighted imaging versus superparamagnetic iron oxide (SPIO)-enhanced MRI: exclusive and combined values in the assessment of hepatic metastases.

    abstract:PURPOSE:The purpose was to validate diffusion-weighted imaging (DWI) in the assessment of hepatic metastases compared with superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance imaging. MATERIALS AND METHODS:For 21 consecutive patients with 160 metastases from extrahepatic malignancy and 25 benign focal lesi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.12.007

    authors: Kim H,Yu JS,Cho ES,Chung JJ,Kim JH,Kim DJ,Ahn JH,Kim KW

    更新日期:2012-05-01 00:00:00

  • Hepatic sarcoidosis: MR appearances in patients with chronic liver disease.

    abstract:PURPOSE:To describe the MR appearances of hepatic sarcoidosis in patients with chronic liver disease and correlate the results with clinical stage of disease as measured with the Mayo end-stage liver disease (MELD) score. MATERIALS AND METHODS:Twenty patients with chronic liver disease and histopathological diagnosis ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.08.005

    authors: Ferreira A,Ramalho M,de Campos RO,Heredia V,Roque A,Vaidean G,Semelka RC

    更新日期:2013-04-01 00:00:00

  • Chemical exchange saturation transfer MR imaging of articular cartilage glycosaminoglycans at 3 T: Accuracy of B0 Field Inhomogeneity corrections with gradient echo method.

    abstract::Glycosaminoglycan Chemical Exchange Saturation Transfer (gagCEST) is an important molecular MRI methodology developed to assess changes in cartilage GAG concentrations. The correction for B0 field inhomogeneity is technically crucial in gagCEST imaging. This study evaluates the accuracy of the B0 estimation determined...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.009

    authors: Wei W,Jia G,Flanigan D,Zhou J,Knopp MV

    更新日期:2014-01-01 00:00:00

  • Changes in the liver parenchyma after proton beam radiotherapy: evaluation with MR imaging.

    abstract::The objective of this study was to describe magnetic resonance (MR) findings with a 1.5T imager for hepatic parenchymal changes after proton beam radiotherapy. Thirty-two patients who received proton radiotherapy with doses of 50-87 Gy underwent MR imaging 1-75 months (mean 22 months) after the start of irradiation. A...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00152-1

    authors: Onaya H,Itai Y,Yoshioka H,Ahmadi T,Niitsu M,Okumura T,Akine Y,Matsuzaki Y,Doi M,Tsuji H,Tsujii H

    更新日期:2000-07-01 00:00:00

  • A spectroscopic NMR investigation of the calcium silicate hydrates present in cement and concrete.

    abstract::NMR spectroscopy is applied to study microstructure of calcium silicate hydrates present in cement and concrete. It is shown that 29Si NMR gives information on the siliceous skeleton of the hydrates. 1H NMR, using CRAMPS techniques, allows to discriminate between protons linked to silicon atoms or to calcium atoms. A ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00211-1

    authors: Zanni H,Rassem-Bertolo R,Masse S,Fernandez L,Nieto P,Bresson B

    更新日期:1996-01-01 00:00:00

  • Finite element aided tracking of signal intensity changes in deforming intervertebral disc tissue.

    abstract::Tracking of signal intensity changes in soft tissue over time is often hampered by deformation of the tissue. In this study a method is described that uses finite element modeling to compensate for tissue deformation. The method is applied to the quantification of fluid redistribution in an intervertebral disc that de...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00251-8

    authors: Kingma I,Weinans H,van Dieën JH,de Boer RW

    更新日期:1998-01-01 00:00:00

  • Utility of magnetization prepared GRE MRI for the detection of focal liver lesions.

    abstract::We compared the efficacy of rapidly acquired magnetization prepared gradient-echo (MP-GRE) sequences with CT and standard MRI pulse sequences for the detection of focal liver lesions. Fourteen patients with 28 focal liver lesions were scanned. TI times of 300, 450, and 600 ms were used. MP-GRE lesion conspicuity was c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92198-9

    authors: Winter TC 3rd,Freeny PC,Nghiem HV,Thomas CR Jr

    更新日期:1994-01-01 00:00:00