Magnetic resonance cholangiopancreatography (MRCP) of intraductal papillary-mucinous neoplasm (IPMN) of the pancreas: case report.

Abstract:

:The intraductal papillary-mucinous neoplasm (IPMN) is the rarest of the cystic pancreatic tumors. Endoscopic retrograde cholangiopancreatography (ERCP) is currently the gold standard for evaluating IPMN's and can demonstrate dilatation of the main duct or side branches, mural nodules, filling defects, and communication between the tumor and the main pancreatic duct. Recent literature has shown that MRCP may be more sensitive and specific in the diagnosis of IPMN In this case report, we present a patient with IPMN of the pancreas where MRCP was superior to ERCP in characterizing the tumor.

journal_name

Magn Reson Imaging

authors

Peters HE,Vitellas KM

doi

10.1016/s0730-725x(01)00440-4

subject

Has Abstract

pub_date

2001-10-01 00:00:00

pages

1139-43

issue

8

eissn

0730-725X

issn

1873-5894

pii

S0730725X01004404

journal_volume

19

pub_type

杂志文章
  • Reaction of gadolinium chelates with endogenously available ions.

    abstract::The extent of reaction of 153Gd-radiolabeled Gd(L) chelates with 25 mM CO23- (25 mF), PO34-, Zn2+ and Cu2+ at pH 7 was determined for L = EDTA, DTPA, DOTA, HP-DO3A, and DO3A. Gd(EDTA)- and Gd(DTPA)2- reacted (greater than 20% in 10 min) with Cu2+ and Zn2+ in the presence of PO34-. These double replacement reactions yi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90429-p

    authors: Tweedle MF,Hagan JJ,Kumar K,Mantha S,Chang CA

    更新日期:1991-01-01 00:00:00

  • Balanced multi-image demons for non-rigid registration of magnetic resonance images.

    abstract::A new approach is introduced for non-rigid registration of a pair of magnetic resonance images (MRI). It is a generalization of the demons algorithm with low computational cost, based on local information augmentation (by integrating multiple images) and balanced implementation. Specifically, a single deformation that...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.09.013

    authors: Mesin L

    更新日期:2020-12-01 00:00:00

  • Single-sided mobile NMR with a Halbach magnet.

    abstract::A single-sided mobile NMR apparatus with a small Halbach magnet was constructed for the first time. It is lightweight, compact and exhibits good sensitivity. The weight of the device is only 2 kg, and the NMR signal of the pencil eraser block can be detected in one shot using the device. This study describes the chara...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.04.005

    authors: Chang WH,Chen JH,Hwang LP

    更新日期:2006-10-01 00:00:00

  • Automated measurement of fat infiltration in the hip abductors from Dixon magnetic resonance imaging.

    abstract:PURPOSE:Intramuscular fat infiltration is a dynamic process, in response to exercise and muscle health, which can be quantified by estimating fat fraction (FF) from Dixon MRI. Healthy hip abductor muscles are a good indicator of a healthy hip and an active lifestyle as they have a fundamental role in walking. The autom...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.06.019

    authors: Belzunce MA,Henckel J,Fotiadou A,Di Laura A,Hart A

    更新日期:2020-10-01 00:00:00

  • The comparison of the performance of 3 T and 7 T T2 mapping for untreated low-grade cartilage lesions.

    abstract:OBJECTIVE:To investigate T2 mapping as a possible marker for low-grade human articular cartilage lesions during a one-year follow-up, possible changes during the follow-up and compare the reliability and sensitivity of these measurements on high-field (3 T) and ultra-high-field (7 T) MRI scanners. DESIGN:Twenty-one pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.09.021

    authors: Juras V,Schreiner M,Laurent D,Zbýň Š,Mlynarik V,Szomolanyi P,Hager B,Scotti C,Goldhahn J,Heule R,Bieri O,Trattnig S

    更新日期:2019-01-01 00:00:00

  • Velocity distribution of slow fluid flows in Bentheimer sandstone: an NMRI and propagator study.

    abstract::This work addresses the special problems of measuring flow velocity distributions in rock by NMR methods. Specifically, these problems are to measure very slow flows as well as flows in the presence of background magnetic field gradients caused by heterogeneities of the rock. We modify a stimulated echo sequence for u...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00110-5

    authors: Waggoner RA,Fukushima E

    更新日期:1996-01-01 00:00:00

  • Equivalent cross relaxation rate image for decreasing a false negative case of sentinel lymph node biopsy.

    abstract::In the breast carcinamas, sentinel lymph node biopsy (SLNB) attracts attention as technique to be settled by axillary lymph node metastasis, but existence of a false negative case is a problem. Equivalent cross relaxation rate image (ECRI) is the measurement method that we can evaluate a change of organization structu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00208-x

    authors: Matsushima S,Sasaki F,Sarumaru S,Ohta D,Era S,Sogami M,Inaba T,Kinosada Y

    更新日期:2003-11-01 00:00:00

  • Detection of viable myocardium in segments with fixed defects on thallium-201 scintigraphy: usefulness of magnetic resonance imaging early after acute myocardial infarction.

    abstract::To determine if magnetic resonance imaging (MRI) can be used to detect tissue viability in segments with persistent 201T1 defects early following acute myocardial infarction, 24 patients underwent MRI and adenosine 201T1 single photon emission computed tomography (SPECT) imaging at approximately 6 days. Infarction was...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90214-x

    authors: Johnston DL,Gupta VK,Wendt RE,Mahmarian JJ,Verani MS

    更新日期:1993-01-01 00:00:00

  • Effect of ovariectomy on contrast agent diffusion into lumbar intervertebral disc: a dynamic contrast-enhanced MRI study in female rats.

    abstract:PURPOSE:The purpose was to study the effect of estrogen deficiency on contrast agent diffusion into intervertebral disc in a rat model. MATERIALS AND METHODS:Seven-month-old female Sprague-Dawley rats were used. Fourteen rats had ovariectomy, and nine rats had sham surgery. Magnetic resonance imaging (MRI) of sagittal...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.01.001

    authors: Deng M,Griffith JF,Zhu XM,Poon WS,Ahuja AT,Wang YX

    更新日期:2012-06-01 00:00:00

  • Multicontrast multiecho FLASH MRI for targeting the subthalamic nucleus.

    abstract::The subthalamic nucleus (STN) is one of the most common stimulation targets for treating Parkinson's disease using deep brain stimulation (DBS). This procedure requires precise placement of the stimulating electrode. Common practice of DBS implantation utilizes microelectrode recording to locate the sites with the cor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.02.006

    authors: Xiao Y,Beriault S,Pike GB,Collins DL

    更新日期:2012-06-01 00:00:00

  • Functional evaluation of normal and ischemic kidney by means of gadolinium-DOTA enhanced TurboFLASH MR imaging: a preliminary comparison with 99Tc-MAG3 dynamic scintigraphy.

    abstract::The functional value of TurboFLASH MR imaging in the assessment of dynamic contrast enhancement and renal perfusion anomalies was evaluated in seven patients, who also underwent renal scintigraphy in baseline conditions. The basal renograms obtained from MAG-3 scintigraphy (mercapto acetyl triglycine, MAG3-S) and from...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92534-8

    authors: Laissy JP,Faraggi M,Lebtahi R,Soyer P,Brillet G,Méry JP,Menu Y,Le Guludec D

    更新日期:1994-01-01 00:00:00

  • Drug monitoring of 5-fluorouracil: in vivo 19F NMR study during 5-FU chemotherapy in patients with metastases of colorectal adenocarcinoma.

    abstract::The metabolism of 5-fluorouracil (5-FU) is complex and the reason for the low response rate of tumor patients to 5-FU is currently unknown. The aim of this study was to evaluate whether spectral parameters obtained noninvasively by in vivo 19F nuclear magnetic resonance (NMR) spectroscopy can be used to assess individ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92544-5

    authors: Schlemmer HP,Bachert P,Semmler W,Hohenberger P,Schlag P,Lorenz WJ,van Kaick G

    更新日期:1994-01-01 00:00:00

  • Explicit treatment of mutual inductance in eight-column birdcage resonators.

    abstract::A formulation has been developed for the determination of self and mutual inductances in unloaded, eight-column symmetric birdcage coils using their expected resonant mode current patterns and well-known inductance formulas. The average frequency differences between theory and experiment for mode one resonances for ni...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90511-w

    authors: Pascone R,Vullo T,Farrelly J,Cahill PT

    更新日期:1992-01-01 00:00:00

  • Electrocardiograph-triggered two-dimensional time-of-flight versus optimized contrast-enhanced three-dimensional MR angiography of the peripheral arteries.

    abstract::We determined whether the accuracy of magnetic resonance angiography (MRA) in the peripheral run-off vessels can be improved by using contrast-enhanced (CE) three-dimensional (3D) technique in comparison to electrocardiograph (ECG)-triggered two-dimensional (2D) time-of-flight (TOF) technique. In a prospective study 2...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00078-2

    authors: Vosshenrich R,Kopka L,Castillo E,Böttcher U,Graessner J,Grabbe E

    更新日期:1998-10-01 00:00:00

  • Investigations of polymer dynamics in nanoporous media by field cycling NMR relaxometry and the dipolar correlation effect.

    abstract::The chain dynamics of short-chain perfluoropolyether melts confined in Vycor nanoporous media has been characterized by field cycling nuclear magnetic resonance relaxometry and the dipolar correlation effect. The slowdown of motions under confinement, leading to larger residual dipolar couplings, has been probed by lo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.11.018

    authors: Kausik R,Fatkullin N,Hüsing N,Kimmich R

    更新日期:2007-05-01 00:00:00

  • Magnetic resonance T2* measurements of the normal human lung in vivo with ultra-short echo times.

    abstract::The objective of this study was to measure T2* values of the normal human lung in vivo during breathhold using a rapid gradient-echo sequence with ultra-short echo times (TE). A sagittal slice of the right lung was imaged in six volunteers with various TE ranging from 0.5 ms to 5 ms using a clinical 1.5 Tesla MR scann...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00047-8

    authors: Stock KW,Chen Q,Hatabu H,Edelman RR

    更新日期:1999-09-01 00:00:00

  • Hepatic sarcoidosis: MR appearances in patients with chronic liver disease.

    abstract:PURPOSE:To describe the MR appearances of hepatic sarcoidosis in patients with chronic liver disease and correlate the results with clinical stage of disease as measured with the Mayo end-stage liver disease (MELD) score. MATERIALS AND METHODS:Twenty patients with chronic liver disease and histopathological diagnosis ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.08.005

    authors: Ferreira A,Ramalho M,de Campos RO,Heredia V,Roque A,Vaidean G,Semelka RC

    更新日期:2013-04-01 00:00:00

  • A rapid method for the measurement and estimation of CO2 diffusivity in liquid hydrocarbon-saturated porous media using MRI.

    abstract::In this study, magnetic resonance imaging (MRI) was used to dynamically visualize the diffusion process of CO2 in porous media saturated with liquid hydrocarbon. Based on the assumption of semi-infinite media, effective CO2 diffusivity was obtained directly by the nonlinear fitting of one MR profile during the diffusi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.024

    authors: Zhao Y,Chen J,Yang M,Liu Y,Song Y

    更新日期:2016-05-01 00:00:00

  • Abdominal imaging studies: comparison of diagnostic accuracies resulting from ultrasound, computed tomography, and magnetic resonance imaging in the same individual.

    abstract::We retrospectively compared the diagnostic accuracy of abdominal ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI) studies performed on the same individual to determine the relative performance of these modalities in the evaluation of disease processes, arising from different intra-abdomi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.01.001

    authors: Noone TC,Semelka RC,Chaney DM,Reinhold C

    更新日期:2004-01-01 00:00:00

  • Data-driven curvilinear reconstructions of 3D MR images: application to cryptogenic extratemporal epilepsy.

    abstract::This paper presents a data-driven method for the reconstruction and visualisation of curvilinear slices from three-dimensional (3D) magnetic resonance (MR) scans of the head. Visualisation of curvilinear slices, rather than standard planar slices, produces symmetrical views of the cortex and allows small abnormalities...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00132-5

    authors: Musse O,Armspach JP,Namer IJ,Heitz F,Hennel F,Grucker D

    更新日期:1998-12-01 00:00:00

  • Fast magnetic resonance in vascular diseases of the abdomen.

    abstract::Fast magnetic resonance (MR) imaging provides a consistent and predictable appearance of vascular abnormalities as shown by four patients with thrombi, dissection and aneurysm. Fast MR images are obtained during breath-holding, resulting in an absence of respiratory motion artifacts. The time of MR study is much less ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90483-3

    authors: Raval B,Kulkarni M,Narayana P,Mehta S

    更新日期:1988-07-01 00:00:00

  • Correction of partial volume inaccuracies in quantitative phase contrast MR angiography.

    abstract::The phase difference method of phase contrast MR angiography provides a means of measuring the average velocity in each voxel of an MR scan. When static tissue is present in a voxel containing flow, the measured velocity is not the average velocity of the flow alone, but is lower due to the partial volume effect of th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91245-r

    authors: Hamilton CA

    更新日期:1994-01-01 00:00:00

  • A new RF transmit coil for foot and ankle imaging at 7T MRI.

    abstract::A four-channel Tic-Tac-Toe (TTT) transmit RF coil was designed and constructed for foot and ankle imaging at 7T MRI. Numerical simulations using an in-house developed FDTD package and experimental analyses using a homogenous phantom show an excellent agreement in terms of B1+ field distribution and s-parameters. Simul...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.09.005

    authors: Santini T,Kim J,Wood S,Krishnamurthy N,Farhat N,Maciel C,Raval SB,Zhao T,Ibrahim TS

    更新日期:2018-01-01 00:00:00

  • Hair product artifact in magnetic resonance imaging.

    abstract::The presence of metallic compounds in facial cosmetics and permanent tattoos may affect the quality of magnetic resonance imaging. We report a case study describing a signal artifact due to the use of a leave-on powdered hair dye. On reviewing the ingredients of the product, it was found to contain several metallic co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.08.023

    authors: Chenji S,Wilman AH,Mah D,Seres P,Genge A,Kalra S

    更新日期:2017-01-01 00:00:00

  • Cardiac magnetic resonance tissue tracking in right ventricle: Feasibility and normal values.

    abstract:PURPOSE:To investigate right ventricular (RV) strain in patients without identified cardiac pathology using cardiac magnetic resonance tissue tracking (CMR TT). METHODS:A total of 50 consecutive patients with no identified cardiac pathology were analyzed. RV longitudinal and circumferential strain was assessed by CMR ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.01.007

    authors: Truong VT,Safdar KS,Kalra DK,Gao X,Ambach S,Taylor MD,Moore R,Taylor RJ,Germann J,Toro-Salazar O,Jefferies JL,Bartone C,Raman SV,Ngo T,Mazur W

    更新日期:2017-05-01 00:00:00

  • Characteristics of geometric distortion correction with increasing field-of-view in open-configuration MRI.

    abstract::Open-configuration magnetic resonance imaging (MRI) systems are becoming increasingly desirable for musculoskeletal imaging and image-guided radiotherapy because of their non-claustrophobic configuration. However, geometric image distortion in large fields-of-view (FOV) due to field inhomogeneity and gradient nonlinea...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.02.007

    authors: Hong C,Lee DH,Han BS

    更新日期:2014-07-01 00:00:00

  • A highly accurate symmetric optical flow based high-dimensional nonlinear spatial normalization of brain images.

    abstract::Spatial normalization plays a key role in voxel-based analyses of brain images. We propose a highly accurate algorithm for high-dimensional spatial normalization of brain images based on the technique of symmetric optical flow. We first construct a three dimension optical model with the consistency assumption of inten...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.01.013

    authors: Wen Y,Hou L,He L,Peterson BS,Xu D

    更新日期:2015-05-01 00:00:00

  • Pure uterine lipoma.

    abstract::Lipomatous tumors of the uterus are unusual, benign neoplasms seen in postmenopausal women. Although many of the mixed-type cases such as lipoleiomyoma and fibrolipoma have been reported, pure uterine lipomas are extremely rare. In the literature, a few cases with pure uterine lipoma have been reported. We first prese...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.01.116

    authors: Erdem G,Celik O,Karakas HM,Alkan A,Hascalik S

    更新日期:2007-10-01 00:00:00

  • Assessment of myocardial perfusion using multisection first-pass MRI and color-coded parameter maps: a comparison to 99mTc Sesta MIBI SPECT and systolic myocardial wall thickening analysis.

    abstract::The most recently reported magnetic resonance first-pass myocardial perfusion studies were restricted to single slice imaging or a data analysis based on interactively placed regions of interest. This study was designed to investigate a new saturation recovery TurboFLASH sequence for multisection myocardial perfusion ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00166-0

    authors: Penzkofer H,Wintersperger BJ,Knez A,Weber J,Reiser M

    更新日期:1999-02-01 00:00:00

  • Resolution and uncertainty of Laplace inversion spectrum.

    abstract::Laplace inversion has been widely used in analyzing nuclear magnetic resonance data to obtain a spectrum of decay time constant, such as the T(2) spectrum. However, due to the ill-conditioned nature of such inversion, it is difficult to determine the reliability and error of the resulting spectrum. This article descri...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2006.11.023

    authors: Song YQ

    更新日期:2007-05-01 00:00:00