Explicit treatment of mutual inductance in eight-column birdcage resonators.

Abstract:

:A formulation has been developed for the determination of self and mutual inductances in unloaded, eight-column symmetric birdcage coils using their expected resonant mode current patterns and well-known inductance formulas. The average frequency differences between theory and experiment for mode one resonances for nine low-pass coils were 0.66 (+/- 0.57) MHz and 2.14 (+/- 2.08) MHz using effective (self plus mutual) and self inductances, respectively, and similarly, for three high-pass coils, 1.19 (+/- 0.56) MHz and 2.79 (+/- 2.20) MHz. These frequency differences were more pronounced for the higher modes; for mode four, the differences neglecting mutual inductance were 14.30 (+/- 11.10) MHz and 10.42 (+/- 4.60) MHz for the low- and high-pass coils, respectively. This analysis provides the first explicit evaluation of the total end-ring and column inductances L1 and L2 within each birdcage section at resonance with resulting excellent agreement in resonant frequencies between theory and experiment.

journal_name

Magn Reson Imaging

authors

Pascone R,Vullo T,Farrelly J,Cahill PT

doi

10.1016/0730-725x(92)90511-w

subject

Has Abstract

pub_date

1992-01-01 00:00:00

pages

401-10

issue

3

eissn

0730-725X

issn

1873-5894

pii

0730-725X(92)90511-W

journal_volume

10

pub_type

杂志文章
  • A simple way to acquire T(1)-weighted MR images of rat liver with respiratory triggering.

    abstract::To acquire high-resolution T(1)-weighted images of the liver in rats, for which breath-holding cannot be ensured, respiratory triggering is essential. At the respiratory rate of 30-60 times/min in rats, however, T(1)-weighted images cannot be obtained with simple triggering. As a simple solution to this, we applied mu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.10.005

    authors: Morikawa S,Murayama H,Fujimoto S,Shiino A,Inubushi T

    更新日期:2012-04-01 00:00:00

  • Resolution and uncertainty of Laplace inversion spectrum.

    abstract::Laplace inversion has been widely used in analyzing nuclear magnetic resonance data to obtain a spectrum of decay time constant, such as the T(2) spectrum. However, due to the ill-conditioned nature of such inversion, it is difficult to determine the reliability and error of the resulting spectrum. This article descri...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2006.11.023

    authors: Song YQ

    更新日期:2007-05-01 00:00:00

  • MRI appearance of disseminated osseous tuberculosis.

    abstract::Disseminated osseous tuberculosis is a rare disease. This is a report of two cases of disseminated osseous tuberculosis imaged with MRI at 1.5-T, CT, plain radiography and bone scintigraphy. CT and plain radiography demonstrated either highly destructive or cystic lesions with sclerotic margins. Bone scintigraphy and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90384-5

    authors: Quinn SF,Murray W,Prochaska J,Cochran C,Clark R

    更新日期:1987-01-01 00:00:00

  • Reducing SAR in parallel excitation using variable-density spirals: a simulation-based study.

    abstract::Parallel excitation using multiple transmit channels has emerged as an effective method to shorten multidimensional spatially selective radiofrequency (RF) pulses, which have a number of important applications, including B1 field inhomogeneity correction in high-field MRI. The specific absorption rate (SAR) is a prima...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.02.003

    authors: Liu Y,Feng K,McDougall MP,Wright SM,Ji J

    更新日期:2008-10-01 00:00:00

  • Application of magnetic resonance imaging to the measurement of neurodegeneration in rat brain: MRI data correlate strongly with histology and enzymatic analysis.

    abstract::Focal brain ischemia was induced by middle cerebral artery occlusion in the rat. The volume of cerebral damage was determined 2 days later by MRI in vivo and in the same animals histologically. The edema volume as measured by MRI and the histologically determined infarction was highly correlated. As a consequence, the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90411-r

    authors: Allegrini PR,Sauer D

    更新日期:1992-01-01 00:00:00

  • Non-Gaussian diffusion MRI assessment of brain microstructure in mild cognitive impairment and Alzheimer's disease.

    abstract::We report the first application of a novel diffusion-based MRI method, called diffusional kurtosis imaging (DKI), to investigate changes in brain tissue microstructure in patients with mild cognitive impairment (MCI) and AD and in cognitively intact controls. The subject groups were characterized and compared in terms...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.02.008

    authors: Falangola MF,Jensen JH,Tabesh A,Hu C,Deardorff RL,Babb JS,Ferris S,Helpern JA

    更新日期:2013-07-01 00:00:00

  • Evaluation of preprocessing steps to compensate for magnetic field distortions due to body movements in BOLD fMRI.

    abstract::Blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) is currently the dominant technique for non-invasive investigation of brain functions. One of the challenges with BOLD fMRI, particularly at high fields, is compensation for the effects of spatiotemporally varying magnetic field inho...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.07.005

    authors: Barry RL,Williams JM,Klassen LM,Gallivan JP,Culham JC,Menon RS

    更新日期:2010-02-01 00:00:00

  • Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain.

    abstract::Deep brain stimulation (DBS) is used increasingly in the field of movement disorders. The implanted electrodes create not only a prior risk to patient safety during MRI, but also a unique opportunity in the collection of functional MRI data conditioned by direct neural stimulation. We evaluated MRI-related heating for...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.02.007

    authors: Bhidayasiri R,Bronstein JM,Sinha S,Krahl SE,Ahn S,Behnke EJ,Cohen MS,Frysinger R,Shellock FG

    更新日期:2005-05-01 00:00:00

  • Lesion load measurements in multiple sclerosis: the effect of incorporating magnetization transfer contrast in fast-FLAIR sequence.

    abstract::We compared the ability and reproducibility of a fast fluid-attenuated inversion recovery (fast-FLAIR) sequence with and without a magnetization transfer (MT) pulse for detecting and measuring multiple sclerosis (MS)-related abnormalities on magnetic resonance imaging (MRI) scans from 20 patients. The Contrast-to-Nois...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00182-9

    authors: Filippi M,Rocca MA,Mastronardo G,Comi G

    更新日期:1999-04-01 00:00:00

  • Accuracy and reproducibility of automated white matter hyperintensities segmentation with lesion segmentation tool: A European multi-site 3T study.

    abstract::Brain vascular damage accumulate in aging and often manifest as white matter hyperintensities (WMHs) on MRI. Despite increased interest in automated methods to segment WMHs, a gold standard has not been achieved and their longitudinal reproducibility has been poorly investigated. The aim of present work is to evaluate...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.11.008

    authors: Ribaldi F,Altomare D,Jovicich J,Ferrari C,Picco A,Pizzini FB,Soricelli A,Mega A,Ferretti A,Drevelegas A,Bosch B,Müller BW,Marra C,Cavaliere C,Bartrés-Faz D,Nobili F,Alessandrini F,Barkhof F,Gros-Dagnac H,Ranjeva JP

    更新日期:2021-02-01 00:00:00

  • Multicontrast multiecho FLASH MRI for targeting the subthalamic nucleus.

    abstract::The subthalamic nucleus (STN) is one of the most common stimulation targets for treating Parkinson's disease using deep brain stimulation (DBS). This procedure requires precise placement of the stimulating electrode. Common practice of DBS implantation utilizes microelectrode recording to locate the sites with the cor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.02.006

    authors: Xiao Y,Beriault S,Pike GB,Collins DL

    更新日期:2012-06-01 00:00:00

  • Optimized 3D bright blood MRI of aortic plaque at 3 T.

    abstract:PURPOSE:To evaluate the feasibility of an optimized bright blood MRI protocol at 3 T in combination with contrast agent administration for the detection and characterization of aortic high-risk plaques for the improved workup of acute stroke patients. MATERIALS AND METHODS:ECG synchronized T1-weighted 3D gradient echo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.08.010

    authors: Markl M,Dudler P,Fydrychowicz A,Strecker C,Weiller C,Hennig J,Harloff A

    更新日期:2008-04-01 00:00:00

  • The Langerhans' cell histiocytosis (eosinophilic granuloma) of the cervical spine: a rare diagnosis of cervical pain.

    abstract::We present the case of a 44-year-old man who complained of cervical pain. He was treated with physiotherapy and analgetics. Because of persistent pain, computed tomography (CT) scan and MRI were performed. They revealed an osteolytic destruction of the fourth cervical vertebra. The patient was treated surgically for r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.01.006

    authors: Simanski C,Bouillon B,Brockmann M,Tiling T

    更新日期:2004-05-01 00:00:00

  • Effects of 3D sampling in (k, t)-space on temporal qualities of dynamic MRI.

    abstract::3D (kx, ky, t)-space analysis is invoked to provide insights into dynamic magnetic resonance imaging (DMRI) with arbitrary k-space sampling trajectories. The effects of 3D sampling in (kx, ky, t) are analyzed theoretically and verified with computer simulation. The analyses show that a 3D sampling pattern that is more...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.04.009

    authors: Park JB,Nishimura DG

    更新日期:2006-10-01 00:00:00

  • Lee-Goldburg solid-state imaging.

    abstract::A new approach to solid-state imaging (SSI) is presented. The method relies on narrowing the resonance line using the Lee-Goldburg sequence. The technique is easy to implement in practice and may find widespread applications in materials science. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90409-s

    authors: De Luca F,Lugeri N,De Simone BC,Maraviglia B

    更新日期:1992-01-01 00:00:00

  • MRI of polysplenia syndrome.

    abstract::The polysplenia syndrome is the association of multiple spleens, situs inversus, congenital heart disease, and azygous continuation of the inferior vena cava. Magnetic resonance (MR) is a noninvasive imaging modality which can easily confirm the multiplicity of spleens, situs inversus, and identify complex congenital ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90538-9

    authors: Jelinek JS,Stuart PL,Done SL,Ghaed N,Rudd SA

    更新日期:1989-11-01 00:00:00

  • Quantification of synovistis by MRI: correlation between dynamic and static gadolinium-enhanced magnetic resonance imaging and microscopic and macroscopic signs of synovial inflammation.

    abstract::Dynamic and static gadolinium-diethylenetriaminepentaacetic acid(Gd-DTPA)-enhanced magnetic resonance imaging (MRI) were evaluated as measures of joint inflammation in arthritis, by a comparison with macroscopic and microscopic signs of synovitis. Furthermore, the importance of the size of the evaluated synovial areas...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00008-3

    authors: Ostergaard M,Stoltenberg M,Løvgreen-Nielsen P,Volck B,Sonne-Holm S,Lorenzen I

    更新日期:1998-09-01 00:00:00

  • High-resolution, three-dimensional diffusion-weighted breast imaging using DESS.

    abstract:PURPOSE:To evaluate the use of the double-echo steady-state (DESS) sequence for acquiring high-resolution breast images with diffusion and T2 weighting. MATERIALS AND METHODS:Phantom scans were used to verify the T2 and diffusion weighting of the DESS sequence. Image distortion was evaluated in volunteers by comparing...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.12.014

    authors: Granlund KL,Staroswiecki E,Alley MT,Daniel BL,Hargreaves BA

    更新日期:2014-05-01 00:00:00

  • Anisotropic diffusion in etched particle tracks studied by field gradient NMR.

    abstract::Etched particle tracks produced after heavy ion irradiation of polymer foils are used as model systems to test the performance of NMR in a newly developed ultrahigh magnetic field gradient system. The stimulated NMR echo decay of molecules diffusing in the channels, formulated in terms of the self part of the intermed...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91527-x

    authors: Fujara F,Ilyina E,Nienstaedt H,Sillescu H,Spohr R,Trautmann C

    更新日期:1994-01-01 00:00:00

  • Quantitative longitudinal fluid saturation profiles with a slice-selected CPMG sequence.

    abstract::A technique for obtaining quantitative longitudinal saturation/porosity profiles of rock cores which are longer than the NMR coil has been developed. The slice-selected experiment uses a prefocused pulse in conjunction with a magnetic field gradient for the localization and a CPMG sequence to sample the data. A variet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91547-4

    authors: Pierens GK,Peyron M,Lucas AJ,Carpenter TA,Hall LD,Potter GF,Stewart RC,Phelps DW

    更新日期:1994-01-01 00:00:00

  • The reliability of routine clinical post-processing software in assessing potential diffusion-weighted MRI "biomarkers" in brain metastases.

    abstract:BACKGROUND AND PURPOSE:Diffusion MRI characteristics have been used as biomarkers to guide prognosis in cerebral pathologies including brain metastases. The measurement of ADC is often described poorly in clinical and research studies with little detail given to the practical considerations of where to place ROIs, whic...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.12.010

    authors: Zakaria R,Das K,Bhojak M,Radon M,Sluming V,Walker C,Jenkinson MD

    更新日期:2014-04-01 00:00:00

  • Background parenchymal enhancement in the contralateral normal breast of patients undergoing neoadjuvant chemotherapy measured by DCE-MRI.

    abstract::The purpose of this study was to analyze background parenchymal enhancement (BPE) in the contralateral normal breast of cancer patients during the course of neoadjuvant chemotherapy (NAC). Forty-five subjects were analyzed. Each patient had three MRIs, one baseline (B/L) and two follow-up (F/U) studies. The fibrogland...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.014

    authors: Chen JH,Yu H,Lin M,Mehta RS,Su MY

    更新日期:2013-11-01 00:00:00

  • Preliminary evaluation of accelerated microscopic diffusional kurtosis imaging (μDKI) in a rodent model of epilepsy.

    abstract:PURPOSE:Our study aimed to develop accelerated microscopic diffusional kurtosis imaging (μDKI) and preliminarily evaluated it in a rodent model of chronic epilepsy. METHODS:We investigated two μDKI acceleration schemes of reduced sampling density and angular range in a phantom and wild-type rats, and further tested μD...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.10.009

    authors: Ji Y,Lu D,Wu L,Qiu B,Song YQ,Sun PZ

    更新日期:2019-02-01 00:00:00

  • Effect of off-frequency sampling in magnetic resonance elastography.

    abstract::In magnetic resonance elastography (MRE), shear waves at a certain frequency are encoded through bipolar gradients that switch polarity at a controlled encoding frequency and are offset in time to capture wave propagation using a controlled sampling frequency. In brain MRE, there is a possibility that the mechanical a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.09.017

    authors: Johnson CL,Chen DD,Olivero WC,Sutton BP,Georgiadis JG

    更新日期:2012-02-01 00:00:00

  • 1H magnetic resonance imaging and 31P magnetic resonance spectroscopy in experimental filariasis.

    abstract::1H Magnetic resonance imaging and 31P magnetic resonance spectroscopy (MRS) have been carried out in experimental rodent filariasis, i.e., Acanthocheilonema viteae infection in the rodent host, Mastomys coucha. The T2-weighted image of the infected host shows fine hyperintense thread like structures of adult filariid ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00180-x

    authors: Shukla-Dave A,Fatma N,Roy R,Srivastava S,Chatterjee RK,Govindaraju V,Viswanathan AK,Raghunathan P

    更新日期:1997-01-01 00:00:00

  • Segmented diffusion-weighted imaging of the prostate: Application to transperineal in-bore 3T MR image-guided targeted biopsy.

    abstract:OBJECTIVE:This study aims to evaluate the applicability of using single-shot and multi-shot segmented diffusion-weighted imaging (DWI) techniques to support biopsy target localization in a cohort of targeted MRI-guided prostate biopsy patients. MATERIALS AND METHODS:Single-shot echo-planar diffusion-weighted imaging (...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.05.012

    authors: Fedorov A,Tuncali K,Panych LP,Fairhurst J,Hassanzadeh E,Seethamraju RT,Tempany CM,Maier SE

    更新日期:2016-10-01 00:00:00

  • NMR study of the diffusion processes in gels.

    abstract::Stimulated spin-echo and Carr-Purcell pulse sequences, with pulsed magnetic field gradients, have been used to study the self-diffusion processes of the water in swollen and in supercoiled polyacrylamide gels and in polysaccharides agarose gels, for different polymer concentrations. Restricted diffusion effects are ev...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00202-0

    authors: Pavesi L,Balzarini M

    更新日期:1996-01-01 00:00:00

  • Evaluation of water content by spatially resolved transverse relaxation times of human articular cartilage.

    abstract::Non-invasive assessment of cartilage properties, specifically water content, could prove helpful in the diagnosis of early degenerative joint diseases. Transverse relaxation times T(2) of human articular cartilage (34 cartilage slices of three donors) were measured on a pixel-by-pixel basis in a clinical whole body MR...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00144-7

    authors: Lüsse S,Claassen H,Gehrke T,Hassenpflug J,Schünke M,Heller M,Glüer CC

    更新日期:2000-05-01 00:00:00

  • Reproducibility of simultaneous imaging of intracranial and extracranial arterial vessel walls using an improved T1-weighted DANTE-SPACE sequence on a 3 T MR system.

    abstract:PURPOSE:To systematically investigate the scan-rescan, intra-observer, and inter-observer reproducibility of an improved DANTE-SPACE sequence for the simultaneous assessment of intra- and extracranial arterial vessel wall morphology. MATERIALS AND METHODS:Thirty-five healthy volunteers and 10 patients with atheroscler...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.04.016

    authors: Wan L,Zhang N,Zhang L,Long X,Jia S,Li Y,Liang D,Zheng H,Liu X

    更新日期:2019-10-01 00:00:00

  • Fast Field Echo imaging: an overview and contrast calculations.

    abstract::Current fast imaging techniques are based on gradient echo sequences with reduced flip angle excitation pulses and very short repetition times TR. Practical T2 values may be of the order of TR or longer. In this situation, a different image contrast can be obtained, depending on details of the sequence. Four essential...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(88)90472-9

    authors: van der Meulen P,Groen JP,Tinus AM,Bruntink G

    更新日期:1988-07-01 00:00:00