Abstract:
:We studied 26 cases of abdominal aortic aneurysm with magnetic resonance imaging (MRI), computed tomography (CT), ultrasonography (US), and angiography. Data acquired were compared to those obtained at surgery. Diameter of the aneurysm was correctly defined in all cases by CT and MRI, while angiography underestimated the diameter of lesions without peripheral calcifications. Involvement of renal arteries was present in four cases and correctly diagnosed with MRI and angiography in all of them. CT did provide this information in three cases and US were not useful. Also, iliac arteries involvement was depicted by CT, MRI, and angiography in 10 out of 10 patients. Coronal sections of MRI provided comparable images to those of angiography. By comparing these different techniques we verified the good reliability of MRI as investigation tool for an accurate evaluation of aneurysms; its only limit lying in the poor capability of detecting calcifications.
journal_name
Magn Reson Imagingjournal_title
Magnetic resonance imagingauthors
Pavone P,Di Cesare E,Di Renzi P,Marsili L,Ventura M,Spartera C,Passariello Rdoi
10.1016/0730-725x(90)90089-ksubject
Has Abstractpub_date
1990-01-01 00:00:00pages
199-204issue
3eissn
0730-725Xissn
1873-5894pii
0730-725X(90)90089-Kjournal_volume
8pub_type
杂志文章abstract::Truncation artifacts arise in magnetic resonance spectroscopic imaging (MRSI) of the human brain due to limited coverage of k-space necessitated by low SNR of metabolite signal and limited scanning time. In proton MRSI of the head, intense extra-cranial lipid signals "bleed" into brain regions, thereby contaminating s...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(02)00608-2
更新日期:2002-12-01 00:00:00
abstract:OBJECTIVE:To test if three-dimensional (3D) cine spatial frequency-temporal frequency Broad-use Linear Acquisition Speed-up Technique (k-t BLAST) is suitable for rapid evaluation of global and regional left ventricular (LV) functional parameters and to evaluate the influence of gadolinium administration. MATERIALS AND...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2008.01.027
更新日期:2008-07-01 00:00:00
abstract:OBJECTIVES:The objectives of this study were to develop protocols that measure abdominal fat and calf muscle lipids with magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), respectively, at 3 T and to examine the correlation between these parameters and insulin sensitivity. MATERIALS AND METHOD...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.06.006
更新日期:2008-02-01 00:00:00
abstract:AIM:To assess imaging findings and characteristics of the lymphatic system in patients affected by lipedema and lipolymphedema of the lower extremities on Non-Contrast MR Lymphography (NCMRL). MATERIALS AND METHODS:44 lower extremities in 11 consecutive female patients affected by lipedema, and 11 patients with lipoly...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2020.06.010
更新日期:2020-09-01 00:00:00
abstract::A series of direct shear and nuclear magnetic resonance (NMR) tests were performed on a compacted weakly expansive clay saturated by sodium chloride (NaCl) solutions with different concentrations to study the effect of NaCl solution on the shear strength and its mechanism. Results from the direct shear tests show that...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.01.002
更新日期:2019-05-01 00:00:00
abstract::The presence of metallic compounds in facial cosmetics and permanent tattoos may affect the quality of magnetic resonance imaging. We report a case study describing a signal artifact due to the use of a leave-on powdered hair dye. On reviewing the ingredients of the product, it was found to contain several metallic co...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.08.023
更新日期:2017-01-01 00:00:00
abstract:PURPOSE:To evaluate the use of the double-echo steady-state (DESS) sequence for acquiring high-resolution breast images with diffusion and T2 weighting. MATERIALS AND METHODS:Phantom scans were used to verify the T2 and diffusion weighting of the DESS sequence. Image distortion was evaluated in volunteers by comparing...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.12.014
更新日期:2014-05-01 00:00:00
abstract::A quantitative analysis of the dependence of water proton relaxation on water content in randomly packed beds of Sephadex is undertaken. A combination of Osmotic and Capillary theory is used to describe the morphological changes occurring in the packed beds as the water content is lowered. At each water content the wa...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)92032-x
更新日期:1994-01-01 00:00:00
abstract::Fast magnetic resonance (MR) imaging provides a consistent and predictable appearance of vascular abnormalities as shown by four patients with thrombi, dissection and aneurysm. Fast MR images are obtained during breath-holding, resulting in an absence of respiratory motion artifacts. The time of MR study is much less ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(88)90483-3
更新日期:1988-07-01 00:00:00
abstract::In-plane flow quantification in MRI offers the potential for assessing vessel patency, and both volume flow rate and flow velocity. These techniques will have definite future impact on MR angiography. The method used in this paper employs motion artifact suppression technique (MAST) gradients to refocus spins travelli...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(88)90409-2
更新日期:1988-05-01 00:00:00
abstract::White matter loss, ventricular enlargement and white matter lesions are common findings on brain scans of older subjects. Accurate assessment of these different features is therefore essential for normal aging research. Recently, we developed a novel unsupervised classification method, named 'Multispectral Coloring Mo...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2011.09.016
更新日期:2012-02-01 00:00:00
abstract:OBJECTIVE:To characterize capillary perfusion and tissue diffusion changes in transplant renal artery stenosis (TRAS) with diffusion-weighted imaging (DWI). MATERIALS & METHODS:We retrospectively identified 30 patients with non-contrast enhanced magnetic resonance angiography-proven TRAS. Another 20 kidney transplant ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.05.007
更新日期:2019-07-01 00:00:00
abstract:INTRODUCTION:Recent animal and human epidemiological studies suggest that early childhood exposure to anesthesia may have adverse effects on brain development. As more than 50% of pregnant women in the United States and one-third in the United Kingdom receive regional anesthesia during labor and delivery, understanding...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.08.033
更新日期:2015-02-01 00:00:00
abstract::The functional value of TurboFLASH MR imaging in the assessment of dynamic contrast enhancement and renal perfusion anomalies was evaluated in seven patients, who also underwent renal scintigraphy in baseline conditions. The basal renograms obtained from MAG-3 scintigraphy (mercapto acetyl triglycine, MAG3-S) and from...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)92534-8
更新日期:1994-01-01 00:00:00
abstract::Collagen fibers in tendons and entheses are highly ordered. The protons within the bound water are subject to dipolar interactions whose strength depends on the orientation of the fibers to the static magnetic field B(0). Clinical pulse sequences have been employed to investigate this magic angle effect of the Achille...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2008.09.003
更新日期:2009-05-01 00:00:00
abstract::The proton spin-lattice relaxation measured at several frequencies leads to a resolved distribution of four Tli for reactive powder concrete (RPC). The typical Tli frequency dependences are quantitatively interpreted by a biphasic fast exchange model and a proton nuclear relaxation of hydrated paramagnetic ions at the...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00063-0
更新日期:1998-06-01 00:00:00
abstract::In congenital diaphragmatic hernia (CDH), lung hypoplasia and secondary pulmonary hypertension are the major causes of death and severe disability. Based on new therapeutic strategies survival rates could be improved to up to 80%. However, after surgical repair of CDH, long-term follow-up of these pediatric patients i...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2015.08.003
更新日期:2015-12-01 00:00:00
abstract::Dynamic and static gadolinium-diethylenetriaminepentaacetic acid(Gd-DTPA)-enhanced magnetic resonance imaging (MRI) were evaluated as measures of joint inflammation in arthritis, by a comparison with macroscopic and microscopic signs of synovitis. Furthermore, the importance of the size of the evaluated synovial areas...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00008-3
更新日期:1998-09-01 00:00:00
abstract:PURPOSE:Our study aimed to develop accelerated microscopic diffusional kurtosis imaging (μDKI) and preliminarily evaluated it in a rodent model of chronic epilepsy. METHODS:We investigated two μDKI acceleration schemes of reduced sampling density and angular range in a phantom and wild-type rats, and further tested μD...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2018.10.009
更新日期:2019-02-01 00:00:00
abstract:OBJECTIVE:Our purpose was to evaluate imaging findings of breast cancers according to the dominant stroma type by using kinetic curve analysis and model-based perfusion parameters from dynamic contrast-enhanced magnetic resonance imaging. METHODS:From March 2011 to September 2011, 64 cancers in 64 patients were includ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2015.07.010
更新日期:2016-01-01 00:00:00
abstract::Using both quantitative computer-assisted analysis and visual estimation the MR imaging response of brain metastases to whole-brain radiotherapy (WBRT) was prospectively studied in 49 patients. Compared to the computer-assisted analysis, the precision of the visual estimation (by two readers in conference) of tumor re...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(96)00024-0
更新日期:1997-01-01 00:00:00
abstract:PURPOSE:To assess the ability and reproducibility of Non-contrast Magnetic Resonance Lymphography (NMRL) in detecting and quantify lymphedema, using a semiquantitative scoring system. METHODS AND MATERIAL:This is a monocentric retrospective study of 134 consecutive patients with a clinical diagnosis of limb lymphedema...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2020.02.004
更新日期:2020-05-01 00:00:00
abstract::Contrast-enhanced 3D MR voiding urethrography (CE 3D MRVU) was performed on 5 healthy volunteers and 18 patients with urethral disease. After intravenous injection of 0.3 ml/kg gadolinium, the images of the three consecutive acquisitions of the 3D MRVU technique were obtained during voiding. The raw data were reconstr...
journal_title:Magnetic resonance imaging
pub_type: 临床试验,杂志文章
doi:10.1016/j.mri.2004.09.008
更新日期:2004-11-01 00:00:00
abstract::Tumor aggressiveness and response to therapy are influenced by the extravascular extracellular space fraction (EESF) of the malignant tissue. The EESF may, therefore, be an important prognostic parameter for cancer patients. The aim of this study was to investigate whether gadopentetate dimeglumine (Gd-DTPA)-based dyn...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.06.003
更新日期:2008-02-01 00:00:00
abstract::The non-Einstein diffusion behavior of water in a model biological tissue system, intact duck embryos, has been investigated by the use of an in vivo proton pulsed-gradient spin-echo (PGSE) MR imaging technique. Multiple-frame MR images of the intact duck embryos and control solution (0.5 mM CuSO4 doped water) were ac...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(93)90476-t
更新日期:1993-01-01 00:00:00
abstract::In vivo spin-lattice relaxation times, T1, of water and lipid protons of normal and atrophic muscles were measured, using the spatially resolved spectroscopy (SPARS) sequence, in a genetic avian model of myopathy. These T1 values were compared with those of the hypertrophic muscles. Although the water T1 values of mus...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(89)90550-x
更新日期:1989-05-01 00:00:00
abstract::Mycotic pseudoaneurysms of the ascending aorta are rare cardiovascular lesions that carry the risk of potentially disastrous complications such as aortic rupture or widespread sepsis. Regardless of its location in the arterial system, this lesion carries a high mortality rate. Early diagnosis of mycotic pseudoaneurysm...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(93)90251-8
更新日期:1993-01-01 00:00:00
abstract::Phantoms for evaluation of nuclear magnetic resonance (NMR) imaging systems were made from water-based agarose gels, according to a standard procedure herein described. Copper sulfate (CuSO4) was included in the gels to further affect their proton relaxation characteristics. The proton relaxation rates of each batch o...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(86)91068-4
更新日期:1986-01-01 00:00:00
abstract::Twenty-seven patients with soft-tissue tumors were examined with a Picker 0.15-tesla resistive magnet and by computed tomography (CT). In all but one patient, MRI was better than or equal to CT in defining the anatomic extent of the tumor. We could determine whether major vascular structures were engulfed by the tumor...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(85)90398-4
更新日期:1985-01-01 00:00:00
abstract::Laplace inversion has been widely used in analyzing nuclear magnetic resonance data to obtain a spectrum of decay time constant, such as the T(2) spectrum. However, due to the ill-conditioned nature of such inversion, it is difficult to determine the reliability and error of the resulting spectrum. This article descri...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章,评审
doi:10.1016/j.mri.2006.11.023
更新日期:2007-05-01 00:00:00