Preliminary evaluation of accelerated microscopic diffusional kurtosis imaging (μDKI) in a rodent model of epilepsy.

Abstract:

PURPOSE:Our study aimed to develop accelerated microscopic diffusional kurtosis imaging (μDKI) and preliminarily evaluated it in a rodent model of chronic epilepsy. METHODS:We investigated two μDKI acceleration schemes of reduced sampling density and angular range in a phantom and wild-type rats, and further tested μDKI method in pilocarpine-induced epilepsy rats using a 4.7 Tesla MRI. Single slice average μDapp and μKapp maps were derived, and Nissl staining was obtained. RESULTS:The kurtosis maps from two accelerated μDKI sampling schemes (sampling density and range) are very similar to that using fully sampled data (SSIM > 0.95). For the epileptic models, μDKI showed noticeably different contrast from those obtained with conventional DKI. Specifically, the average μKapp was significantly less than that of the average of Kapp (0.15 ± 0.01 vs. 0.47 ± 0.02) in the ventricle. CONCLUSIONS:Our study demonstrated the feasibility of accelerated in vivo μDKI. Our work revealed that μDKI provides complementary information to conventional DKI method, suggesting that advanced DKI sequences are promising to elucidate tissue microstructure in neurological diseases.

journal_name

Magn Reson Imaging

authors

Ji Y,Lu D,Wu L,Qiu B,Song YQ,Sun PZ

doi

10.1016/j.mri.2018.10.009

subject

Has Abstract

pub_date

2019-02-01 00:00:00

pages

90-95

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(18)30366-7

journal_volume

56

pub_type

杂志文章
  • Flexible, phase-matched, linear receive arrays for high-field MRI in monkeys.

    abstract::High signal-to-noise ratios (SNR) are essential for high-resolution anatomical and functional MRI. Phased arrays are advantageous for this but have the drawback that they often have inflexible and bulky configurations. Particularly in experiments where functional MRI is combined with simultaneous electrophysiology, sp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.03.026

    authors: Goense J,Logothetis NK,Merkle H

    更新日期:2010-10-01 00:00:00

  • Tortuosity measurement and the effects of finite pulse widths on xenon gas diffusion NMR studies of porous media.

    abstract::We have extended the utility of NMR as a technique to probe porous media structure over length scales of approximately 100-2000 microm by using the spin 1/2 noble gas 129Xe imbibed into the system's pore space. Such length scales are much greater than can be probed with NMR diffusion studies of water-saturated porous ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00247-8

    authors: Mair RW,Hürlimann MD,Sen PN,Schwartz LM,Patz S,Walsworth RL

    更新日期:2001-04-01 00:00:00

  • In vivo field dependence of proton relaxation times in human brain, liver and skeletal muscle: a multicenter study.

    abstract::T1 and T2 relaxation times are fundamental parameters for signal contrast behaviour in MRI. A number of ex vivo relaxometry studies have dealt with the magnetic field dispersion of T1. By means of multicenter study within the frame of the COMAC BME Concerted Action on Tissue Characterization by MRI and MRS, the in viv...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,多中心研究

    doi:10.1016/0730-725x(93)90202-o

    authors: Henriksen O,de Certaines JD,Spisni A,Cortsen M,Muller RN,Ring PB

    更新日期:1993-01-01 00:00:00

  • Quantitative longitudinal fluid saturation profiles with a slice-selected CPMG sequence.

    abstract::A technique for obtaining quantitative longitudinal saturation/porosity profiles of rock cores which are longer than the NMR coil has been developed. The slice-selected experiment uses a prefocused pulse in conjunction with a magnetic field gradient for the localization and a CPMG sequence to sample the data. A variet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91547-4

    authors: Pierens GK,Peyron M,Lucas AJ,Carpenter TA,Hall LD,Potter GF,Stewart RC,Phelps DW

    更新日期:1994-01-01 00:00:00

  • In situ magnetic resonance measurement of conversion, hydrodynamics and mass transfer during single- and two-phase flow in fixed-bed reactors.

    abstract::In recent years there has been increasing interest in applying magnetic resonance (MR) techniques in areas of engineering and chemical technology. The science that underpins many of these applications is the physics and chemistry of transport and reaction processes in porous materials. Key to the exploitation of MR me...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00127-9

    authors: Gladden LF,Alexander P,Britton MM,Mantle MD,Sederman AJ,Yuen EH

    更新日期:2003-04-01 00:00:00

  • Abdominal aortic aneurysm evaluation: comparison of US, CT, MRI, and angiography.

    abstract::We studied 26 cases of abdominal aortic aneurysm with magnetic resonance imaging (MRI), computed tomography (CT), ultrasonography (US), and angiography. Data acquired were compared to those obtained at surgery. Diameter of the aneurysm was correctly defined in all cases by CT and MRI, while angiography underestimated ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90089-k

    authors: Pavone P,Di Cesare E,Di Renzi P,Marsili L,Ventura M,Spartera C,Passariello R

    更新日期:1990-01-01 00:00:00

  • Fast multi-contrast MRI reconstruction.

    abstract::Multi-contrast magnetic resonance imaging (MRI) is a useful technique to aid clinical diagnosis. This paper proposes an efficient algorithm to jointly reconstruct multiple T1/T2-weighted images of the same anatomical cross section from partially sampled k-space data. The joint reconstruction problem is formulated as m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.025

    authors: Huang J,Chen C,Axel L

    更新日期:2014-12-01 00:00:00

  • MR visible localization device for radiographic-pathologic correlation of surgical specimens.

    abstract:PURPOSE:The detection of small parenchymal hepatic lesions identified by preoperative imaging remains a challenge for traditional pathologic methods in large specimens. We developed a magnetic resonance imaging (MRI) compatible localization device for imaging of surgical specimens aimed to improve identification and lo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.11.021

    authors: Kinner S,Schubert TB,Nocerino EA,Hynes S,Colgan TJ,Loeffler AG,Brace C,Reeder SB,Winslow E

    更新日期:2017-04-01 00:00:00

  • Single-shot-double-echo EPI.

    abstract::Echo planar imaging (EPI) was extended for the acquisition of both, the spin-echo (SE) and the stimulated echo in a stimulated echo sequence after one excitation from thermal equilibrium. The two independent EPI images reflect different states of the transverse magnetization excited and measured almost simultaneously....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91234-n

    authors: Börnert P,Jensen D

    更新日期:1994-01-01 00:00:00

  • Application of machine learning methods to describe the effects of conjugated equine estrogens therapy on region-specific brain volumes.

    abstract::Use of conjugated equine estrogens (CEE) has been linked to smaller regional brain volumes in women aged ≥65 years; however, it is unknown whether this results in a broad-based characteristic pattern of effects. Structural magnetic resonance imaging was used to assess regional volumes of normal tissue and ischemic les...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.mri.2010.12.001

    authors: Casanova R,Espeland MA,Goveas JS,Davatzikos C,Gaussoin SA,Maldjian JA,Brunner RL,Kuller LH,Johnson KC,Mysiw WJ,Wagner B,Resnick SM,Women's Health Initiative Memory Study.

    更新日期:2011-05-01 00:00:00

  • Magnetization transfer and T2 quantitation in normal appearing cortical gray matter and white matter adjacent to focal abnormality in patients with traumatic brain injury.

    abstract::Traumatic brain injury (TBI) is one of the commonest causes of morbidity and mortality in the developed countries with posttraumatic epilepsy and functional disability being its major sequelae. The purpose of this study was to test the hypothesis whether the normal appearing adjacent gray and white matter regions on T...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00189-9

    authors: Kumar R,Gupta RK,Rao SB,Chawla S,Husain M,Rathore RK

    更新日期:2003-10-01 00:00:00

  • Phase detection and contrast loss in magnetic resonance imaging.

    abstract::Several recent articles have assessed the relative efficiency of nuclear magnetic resonance (NMR) pulse sequences. One consideration that has received little attention is the effect on image contrast of displaying images without information on the sign of the reconstructed signals. The radiofrequency receivers current...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(84)90193-0

    authors: Hendrick RE,Nelson TR,Hendee WR

    更新日期:1984-01-01 00:00:00

  • Differentiation of hepatic cavernous hemangioma from metastases by rare sequence MR imaging.

    abstract::In this study, in order to differentiate cavernous hemangioma and hepatic metastases, rapid acquisition relaxation enhanced (RARE) sequence was used. First, in vivo measurements of T1, T2 relaxation times and proton density were obtained using T1, T2 calculation protocol (TOMIKON S50, 0.5T) and multipoint techniques. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00008-9

    authors: Jafari F,Nayeri N,Tahsini M,Khodadoust AA

    更新日期:1999-06-01 00:00:00

  • Fast T2-mapping with snapshot flash imaging.

    abstract::It has been shown recently that quantitative T2-maps may be measured by acquisition of a series of at least eight T2-weighted SNAPSHOT FLASH images. These measurements require a relaxation delay of 10-15 s after each T2-weighted image for the complete relaxation of the spin system. This results in long measuring times...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00004-z

    authors: Deichmann R,Adolf H,Nöth U,Morrissey S,Schwarzbauer C,Haase A

    更新日期:1995-01-01 00:00:00

  • Accuracy and reproducibility of automated white matter hyperintensities segmentation with lesion segmentation tool: A European multi-site 3T study.

    abstract::Brain vascular damage accumulate in aging and often manifest as white matter hyperintensities (WMHs) on MRI. Despite increased interest in automated methods to segment WMHs, a gold standard has not been achieved and their longitudinal reproducibility has been poorly investigated. The aim of present work is to evaluate...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.11.008

    authors: Ribaldi F,Altomare D,Jovicich J,Ferrari C,Picco A,Pizzini FB,Soricelli A,Mega A,Ferretti A,Drevelegas A,Bosch B,Müller BW,Marra C,Cavaliere C,Bartrés-Faz D,Nobili F,Alessandrini F,Barkhof F,Gros-Dagnac H,Ranjeva JP

    更新日期:2021-02-01 00:00:00

  • Issues about the fMRI of the human spinal cord.

    abstract::Noninvasive functional studies on human spinal cord by means of magnetic resonance imaging (MRI) are gaining attention because of the promising applications in the study of healthy and injured central nervous system. The findings obtained are generally consistent with the anatomic knowledge based on invasive methods, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.10.015

    authors: Giove F,Garreffa G,Giulietti G,Mangia S,Colonnese C,Maraviglia B

    更新日期:2004-12-01 00:00:00

  • Noncontrast MRI with diffusion-weighted imaging as the sole imaging modality for detecting liver malignancy in patients with high risk for hepatocellular carcinoma.

    abstract:PURPOSE:To compare the diagnostic performance of the noncontrast MRI including DWI to the standard MRI for detecting hepatic malignancies in patients with chronic liver disease. MATERIALS AND METHODS:We included 135 patients with 136 histologically-confirmed hepatocellular carcinomas (HCCs), 12 cholangiocarcinomas, an...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.12.021

    authors: Kim YK,Kim YK,Park HJ,Park MJ,Lee WJ,Choi D

    更新日期:2014-07-01 00:00:00

  • NMR study of the diffusion processes in gels.

    abstract::Stimulated spin-echo and Carr-Purcell pulse sequences, with pulsed magnetic field gradients, have been used to study the self-diffusion processes of the water in swollen and in supercoiled polyacrylamide gels and in polysaccharides agarose gels, for different polymer concentrations. Restricted diffusion effects are ev...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00202-0

    authors: Pavesi L,Balzarini M

    更新日期:1996-01-01 00:00:00

  • Dynamic sequential 3D gadolinium-enhanced MRI of the whole breast.

    abstract::Dynamic contrast-enhanced 2D MR imaging of the breast has shown high sensitivity and specificity for the detection and characterization of breast lesions. We investigated the ability of a dynamic fast 3D MR imaging technique that repeatedly scans the whole breast in 44-s intervals without an interscan delay time to ob...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02112-7

    authors: Heiberg EV,Perman WH,Herrmann VM,Janney CG

    更新日期:1996-01-01 00:00:00

  • Magnetic resonance T2* measurements of the normal human lung in vivo with ultra-short echo times.

    abstract::The objective of this study was to measure T2* values of the normal human lung in vivo during breathhold using a rapid gradient-echo sequence with ultra-short echo times (TE). A sagittal slice of the right lung was imaged in six volunteers with various TE ranging from 0.5 ms to 5 ms using a clinical 1.5 Tesla MR scann...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00047-8

    authors: Stock KW,Chen Q,Hatabu H,Edelman RR

    更新日期:1999-09-01 00:00:00

  • Influence of baseline hematocrit on between-subject BOLD signal change using gradient echo and asymmetric spin echo EPI.

    abstract::The dependence of BOLD signal change (BSC) on baseline hematocrit is in the process of being characterized, primarily using conventional Gradient Echo (GE) echo planar imaging (EPI). We describe the first empiric exploration of this relationship using, in addition to GE, Spin Echo (SE) and two Asymmetric Spin Echo EPI...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00083-3

    authors: Gustard S,Williams EJ,Hall LD,Pickard JD,Carpenter TA

    更新日期:2003-07-01 00:00:00

  • Study of lipid metabolism by estimating the fat fraction in different breast tissues and in various breast tumor sub-types by in vivo 1H MR spectroscopy.

    abstract:PURPOSE:To evaluate the utility of fat fraction (FF) for the differentiation of different breast tissues and in various breast tumor subtypes using in vivo proton (1H) magnetic resonance spectroscopy (MRS). METHODS:1H MRS was performed on 68 malignant, 35 benign, and 30 healthy volunteers at 1.5 T. Malignant breast ti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.02.004

    authors: Agarwal K,Sharma U,Mathur S,Seenu V,Parshad R,Jagannathan NR

    更新日期:2018-06-01 00:00:00

  • Free-running simultaneous myocardial T1/T2 mapping and cine imaging with 3D whole-heart coverage and isotropic spatial resolution.

    abstract:PURPOSE:To develop a free-running framework for 3D isotropic simultaneous myocardial T1/T2 mapping and cine imaging. METHODS:Continuous data acquisition with 3D golden angle radial trajectory is used in conjunction with T2 preparation of varying echo times and inversion recovery (IR) pulses to enable simultaneous myoc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.08.008

    authors: Qi H,Bustin A,Cruz G,Jaubert O,Chen H,Botnar RM,Prieto C

    更新日期:2019-11-01 00:00:00

  • Resolution and uncertainty of Laplace inversion spectrum.

    abstract::Laplace inversion has been widely used in analyzing nuclear magnetic resonance data to obtain a spectrum of decay time constant, such as the T(2) spectrum. However, due to the ill-conditioned nature of such inversion, it is difficult to determine the reliability and error of the resulting spectrum. This article descri...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2006.11.023

    authors: Song YQ

    更新日期:2007-05-01 00:00:00

  • Evaluation of algorithms for analysis of NMR relaxation decay curves.

    abstract::Quantitative processing of NMR relaxation images depends on the characteristics of the used fitting algorithm. Therefore several common fitting algorithms are compared for decay curves with low signal-to-noise ratios. The use of magnitude data yields a non-zero base line, and is shown to result in an overestimation of...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00200-9

    authors: van der Weerd L,Vergeldt FJ,Adrie de Jager P,Van As H

    更新日期:2000-11-01 00:00:00

  • Spectroscopic imaging of the brain with phased-array coils at 3.0 T.

    abstract::The goal of this study was to develop and evaluate high-resolution magnetic resonance spectroscopic imaging (MRSI) utilizing the gains in signal-to-noise ratio (SNR) provided by combining higher magnetic field with high-sensitivity phased-array (PA) coils. We investigated the maximum improvement in spatial resolution ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.019

    authors: Xu D,Chen AP,Cunningham C,Osorio JA,Nelson SJ,Vigneron DB

    更新日期:2006-01-01 00:00:00

  • A comparison of readout segmented EPI and interleaved EPI in high-resolution diffusion weighted imaging.

    abstract:PURPOSE:To provide a comprehensive understanding of multi-shot EPI diffusion imaging methods by comparing Readout segmented EPI (RS-EPI) and interleaved EPI (iEPI). MATERIALS AND METHODS:RS-EPI and iEPI were compared on the same 3T scanner. A 2D navigator was used for both RS-EPI and iEPI for phase correction. Signal ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.11.011

    authors: Wang Y,Ma X,Zhang Z,Dai E,Jeong HK,Xie B,Yuan C,Guo H

    更新日期:2018-04-01 00:00:00

  • Temporal sampling requirements for the tracer kinetics modeling of breast disease.

    abstract::The physiological parameters measured in the tracer kinetics modeling of data from a dynamic contrast-enhanced magnetic resonance (MR) breast exam (blood flow-extraction fraction product [FE], volume of the extracellular extravascular space [Ve], and blood volume [Vb]) may enable non-invasive diagnosis of breast cance...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00130-1

    authors: Henderson E,Rutt BK,Lee TY

    更新日期:1998-11-01 00:00:00

  • Three dimensional k-space trajectory design using genetic algorithms.

    abstract::Image quality and total scan time in MRI are determined in large part by the trajectory employed to sample the Fourier space. Each trajectory has different properties like coverage of k-space, scan time, sensitivity to off-resonance conditions, etc. These properties are often contradictory, therefore a universal optim...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00174-7

    authors: Sabat S,Mir R,Guarini M,Guesalaga A,Irarrazaval P

    更新日期:2003-09-01 00:00:00

  • MRI inter-slice reconstruction using super-resolution.

    abstract::MRI reconstruction using super-resolution is presented and shown to improve spatial resolution in cases when spatially-selective RF pulses are used for localization. In 2-D multislice MRI, the resolution in the slice direction is often lower than the in-plane resolution. For certain diagnostic imaging applications, is...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00511-8

    authors: Greenspan H,Oz G,Kiryati N,Peled S

    更新日期:2002-06-01 00:00:00