In vivo field dependence of proton relaxation times in human brain, liver and skeletal muscle: a multicenter study.

Abstract:

:T1 and T2 relaxation times are fundamental parameters for signal contrast behaviour in MRI. A number of ex vivo relaxometry studies have dealt with the magnetic field dispersion of T1. By means of multicenter study within the frame of the COMAC BME Concerted Action on Tissue Characterization by MRI and MRS, the in vivo field dispersion of T1 and T2 has been measured in order to evaluate whether ex vivo data are representative for the in vivo situation. Brain, skeletal muscle, and liver of healthy human volunteers were studied. Fifteen MR units with a field strength ranging from 0.08 T to 1.5 T took part in the trial, which comprised 218 volunteers. All the MR systems were tested for measurement accuracy using the Eurospin TO5 test object. The measured relaxation data were subsequently corrected according to the obtained calibration curves. The results showed a clear field dispersion of T1, whereas no significant variations were seen for T2. Our in vivo data were generally in reasonable agreement with proposed models based on ex vivo measurements.

journal_name

Magn Reson Imaging

authors

Henriksen O,de Certaines JD,Spisni A,Cortsen M,Muller RN,Ring PB

doi

10.1016/0730-725x(93)90202-o

subject

Has Abstract

pub_date

1993-01-01 00:00:00

pages

851-6

issue

6

eissn

0730-725X

issn

1873-5894

pii

0730-725X(93)90202-O

journal_volume

11

pub_type

杂志文章,多中心研究
  • Intramuscular adipose tissue determined by T1-weighted MRI at 3T primarily reflects extramyocellular lipids.

    abstract:PURPOSE:The purpose of this study was to assess relationships between intramuscular adipose tissue (IntraMAT) content determined by MRI and intramyocellular lipids (IMCL) and extramyocellular lipids (EMCL) determined by (1)H magnetic resonance spectroscopy ((1)H MRS) or echo intensity determined by B-mode ultrasonograp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.038

    authors: Akima H,Hioki M,Yoshiko A,Koike T,Sakakibara H,Takahashi H,Oshida Y

    更新日期:2016-05-01 00:00:00

  • A simple method for MR elastography: a gradient-echo type multi-echo sequence.

    abstract::To demonstrate the feasibility of a novel MR elastography (MRE) technique based on a conventional gradient-echo type multi-echo MR sequence which does not need additional bipolar magnetic field gradients (motion encoding gradient: MEG), yet is sensitive to vibration. In a gradient-echo type multi-echo MR sequence, sev...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.10.002

    authors: Numano T,Mizuhara K,Hata J,Washio T,Homma K

    更新日期:2015-01-01 00:00:00

  • Off-resonance binomial preparatory pulse technique for high sensitivity MRI of H2O17.

    abstract::H2O17 is a freely diffusible tracer and naturally occurring isotope of O16 detectable by MRI and has been shown to be useful for assessing cerebral perfusion in animal studies using direct and indirect MR detection techniques. However, earlier MR techniques are either not sensitive to changes in small concentrations o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.09.005

    authors: Sood R

    更新日期:2004-02-01 00:00:00

  • Improved sensitivity of MRI in multiple sclerosis by use of extensive standardized procedures.

    abstract::The relative value of two different MRI procedures for the assessment of infratentorial extension in multiple sclerosis (MS) was studied. Multislice spin-echo techniques were used overall. Procedure A consisted of parasagittal T1-weighted images (500/30) and axial T2-weighted images (2500/30, 2500/120). Procedure B co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90547-x

    authors: Van de Vyver FL,Truyen L,Gheuens J,Degryse HR,Peersman GV,Martin JJ

    更新日期:1989-05-01 00:00:00

  • COmplex-Model-Based Estimation of thermal noise for fMRI data in the presence of artifacts.

    abstract::Due to the presence of artifacts induced by fast-imaging acquisition in functional magnetic resonance imaging (fMRI) studies, it is very difficult to estimate the variance of thermal noise by traditional methods in magnitude images. Moreover, the existence of incidental phase fluctuations impairs the validity of curre...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.12.007

    authors: Xu Y,Wu G,Rowe DB,Ma Y,Zhang R,Xu G,Li SJ

    更新日期:2007-09-01 00:00:00

  • Sampling time effects on signal-to-noise and contrast-to-noise ratios in spin-echo MRI.

    abstract::This work discusses the effect of sampling time on noise, signal-to-noise and contrast-to-noise ratios in magnetic resonance imaging. A simple imaging experiment is performed to demonstrate the effect of sampling time on noise, confirming theoretical expectations that doubling the sampling time while decreasing the re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90481-4

    authors: Hendrick RE

    更新日期:1987-01-01 00:00:00

  • In vitro experiments on ICOSA6 4D flow MRI measurement for the quantification of velocity and turbulence parameters.

    abstract:PURPOSE:To perform comprehensive in vitro experiments using six-directional icosahedral flow encoding (ICOSA6) 4D flow magnetic resonance imaging (MRI) under various scan conditions to analyze the robustness of velocity and turbulence quantification. MATERIALS AND METHODS:In vitro flow phantoms with steady flow rates ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.06.020

    authors: Ha H,Park KJ,Dyverfeldt P,Ebbers T,Yang DH

    更新日期:2020-10-01 00:00:00

  • Application of spherical harmonics derived space rotation invariant indices to the analysis of multiple sclerosis lesions' geometry by MRI.

    abstract::In the longitudinal study of multiple sclerosis (MS) lesions, varying position of the patient inside the MRI scanner is one of the major sources of assessment errors. We propose to use analytical indices that are invariant to spatial orientation to describe the lesions, rather than focus on patient repositioning or im...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.053

    authors: Goldberg-Zimring D,Achiron A,Warfield SK,Guttmann CR,Azhari H

    更新日期:2004-07-01 00:00:00

  • Neuroprotective effect of agmatine in rats with transient cerebral ischemia using MR imaging and histopathologic evaluation.

    abstract:PURPOSE:This study aimed to further investigate the effects of agmatine on brain edema in the rats with middle cerebral artery occlusion (MCAO) injury using magnetic resonance imaging (MRI) monitoring and biochemical and histopathologic evaluation. MATERIALS AND METHODS:Following surgical induction of MCAO for 90min, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.03.026

    authors: Huang YC,Tzeng WS,Wang CC,Cheng BC,Chang YK,Chen HH,Lin PC,Huang TY,Chuang TJ,Lin JW,Chang CP

    更新日期:2013-09-01 00:00:00

  • Removal of extracerebral tissues in dual-echo magnetic resonance images via linear scale-space features.

    abstract::The location and masking of the brain and surrounding cerebrospinal fluid (CSF) in two-dimensional (2D) dual-echo fast spin-echo (FSE) magnetic resonance (MR) images of the head is achieved by an automated procedure with a voxel-based computational algorithm. Linear scale-space features are derived from the short-echo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00099-x

    authors: Suckling J,Brammer MJ,Lingford-Hughes A,Bullmore ET

    更新日期:1999-02-01 00:00:00

  • Artifacts in chemical shift selective imaging.

    abstract::The role of susceptibility effects in the production of artifacts in chemical shift images generated by the selective excitation technique is discussed. The effects are demonstrated in images of phantom samples of agarose gels containing small air bubbles. The artifacts can lead to erroneous interpretations, in which ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90022-r

    authors: Pope JM,Walker RR,Kron T

    更新日期:1992-01-01 00:00:00

  • Spectral pattern of total creatine and trimethyl ammonium in multiple sclerosis.

    abstract::Fatigue and impairment mobility are frequent problems in multiple sclerosis (MS). Despite its enormous potential, in vivo (1)H MRS of skeletal muscles for MS patients is a largely unexplored field. One fundamental question remains unanswered: whether MS can cause observable proton metabolite changes. High quality two-...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.005

    authors: Hu J,Xu Y,Jiang Q,Sehgal V,Shen Y,Xuan Y,Xia Y

    更新日期:2004-04-01 00:00:00

  • A 32-channel coil system for MR vessel wall imaging of intracranial and extracranial arteries at 3T.

    abstract:PURPOSE:To develop a RF coil system for joint imaging of intracranial and extracranial arterial vessel wall at 3T. MATERIALS AND METHOD:The coil system consists of a 24-channel head coil combined with an 8-channel carotid coil. It is compared with a standard coil configuration (12-channel head coil+4-channel neck coil...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.018

    authors: Hu X,Li Y,Zhang L,Zhang X,Liu X,Chung YC

    更新日期:2017-02-01 00:00:00

  • Evaluation of intracranial stenoses and aneurysms with accelerated 4D flow.

    abstract::The aim of this study was to evaluate intracranial arterial stenoses and aneurysms with accelerated time-resolved three-dimensional (3D) phase-contrast MRI or 4D flow. The 4D flow technique was utilized to image four normal volunteers, two patients with intracranial stenoses and two patients with intracranial aneurysm...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.042

    authors: Hope TA,Hope MD,Purcell DD,von Morze C,Vigneron DB,Alley MT,Dillon WP

    更新日期:2010-01-01 00:00:00

  • Flexible, phase-matched, linear receive arrays for high-field MRI in monkeys.

    abstract::High signal-to-noise ratios (SNR) are essential for high-resolution anatomical and functional MRI. Phased arrays are advantageous for this but have the drawback that they often have inflexible and bulky configurations. Particularly in experiments where functional MRI is combined with simultaneous electrophysiology, sp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.03.026

    authors: Goense J,Logothetis NK,Merkle H

    更新日期:2010-10-01 00:00:00

  • Quantitative multi-modal functional MRI with blood oxygenation level dependent exponential decays adjusted for flow attenuated inversion recovery (BOLDED AFFAIR).

    abstract::A magnetic resonance imaging (MRI) method is described that allows interleaved measurements of transverse (R(2)(*) and R(2)) and longitudinal (R(1)) relaxation rates of tissue water in conjunction with spin labeling. The image-contrasts are intrinsically blood oxygenation level dependent (BOLD) and cerebral blood flow...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00125-9

    authors: Hyder F,Renken R,Kennan RP,Rothman DL

    更新日期:2000-04-01 00:00:00

  • The use of power images to perform quantitative analysis on low SNR MR images.

    abstract::Zero-mean noise introduced into quadrature detected MRI signals is generally rectified by the reconstruction algorithm to give a nonzero background intensity in the displayed image. In low signal-to-noise ratio (SNR) images, this background will inflate region of interest (ROI) signal measurements, leading to improper...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90225-3

    authors: Miller AJ,Joseph PM

    更新日期:1993-01-01 00:00:00

  • Effects of gadoxetic acid on liver elasticity measurement by using magnetic resonance elastography.

    abstract::The purpose of this study was to evaluate the effect of gadoxetic acid (Gd-EOB-DTPA) on measurements of liver stiffness by using magnetic resonance elastography (MRE). In this study, 104 consecutive patients (mean age, 67.7±9.4 years) underwent MRE using a 1.5-T MR scanner equipped with a cylindrical passive driver th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.08.005

    authors: Motosugi U,Ichikawa T,Sou H,Sano K,Muhi A,Ehman RL,Araki T

    更新日期:2012-01-01 00:00:00

  • Delayed myelination in a rhizomelic chondrodysplasia punctata case: MR spectroscopy findings.

    abstract::Rhizomelic chondrodysplasia punctata is a member of genetic peroxisomal disorders. Delayed myelination, which is probably related to the inadequacy of plasmalogens biosynthesis, is an important feature of this disorder. Direct assessment of neuropathologic aspects of RCDP syndrome such as neuronal degeneration and del...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00625-2

    authors: Alkan A,Kutlu R,Yakinci C,Sigirci A,Aslan M,Sarac K

    更新日期:2003-01-01 00:00:00

  • Lesion load measurements in multiple sclerosis: the effect of incorporating magnetization transfer contrast in fast-FLAIR sequence.

    abstract::We compared the ability and reproducibility of a fast fluid-attenuated inversion recovery (fast-FLAIR) sequence with and without a magnetization transfer (MT) pulse for detecting and measuring multiple sclerosis (MS)-related abnormalities on magnetic resonance imaging (MRI) scans from 20 patients. The Contrast-to-Nois...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00182-9

    authors: Filippi M,Rocca MA,Mastronardo G,Comi G

    更新日期:1999-04-01 00:00:00

  • Noncontrast MRI with diffusion-weighted imaging as the sole imaging modality for detecting liver malignancy in patients with high risk for hepatocellular carcinoma.

    abstract:PURPOSE:To compare the diagnostic performance of the noncontrast MRI including DWI to the standard MRI for detecting hepatic malignancies in patients with chronic liver disease. MATERIALS AND METHODS:We included 135 patients with 136 histologically-confirmed hepatocellular carcinomas (HCCs), 12 cholangiocarcinomas, an...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.12.021

    authors: Kim YK,Kim YK,Park HJ,Park MJ,Lee WJ,Choi D

    更新日期:2014-07-01 00:00:00

  • Truncation artifact reduction in spectroscopic imaging using a dual-density spiral k-space trajectory.

    abstract::Truncation artifacts arise in magnetic resonance spectroscopic imaging (MRSI) of the human brain due to limited coverage of k-space necessitated by low SNR of metabolite signal and limited scanning time. In proton MRSI of the head, intense extra-cranial lipid signals "bleed" into brain regions, thereby contaminating s...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00608-2

    authors: Sarkar S,Heberlein K,Hu X

    更新日期:2002-12-01 00:00:00

  • Highly homogeneous circularly polarized RF field for whole body NMR imaging.

    abstract::Conditions for generation of polarized RF fields in cylindrical symmetry by high order coils are presented. Whole body NMR transmitters utilizing this principle would require a current control on a certain number of loops. In the present design this is obtained by feeding each loop by an appropriate linear combination...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90398-0

    authors: Sotgiu A,Gualtieri G,Passariello R

    更新日期:1988-05-01 00:00:00

  • NMR study of the diffusion processes in gels.

    abstract::Stimulated spin-echo and Carr-Purcell pulse sequences, with pulsed magnetic field gradients, have been used to study the self-diffusion processes of the water in swollen and in supercoiled polyacrylamide gels and in polysaccharides agarose gels, for different polymer concentrations. Restricted diffusion effects are ev...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00202-0

    authors: Pavesi L,Balzarini M

    更新日期:1996-01-01 00:00:00

  • Intracranial vascular feature changes in time of flight MR angiography in patients undergoing carotid revascularization surgery.

    abstract:PURPOSE:To characterize the intracranial vascular features extracted from time of flight (TOF) images and their changes from baseline to follow-up in patients undergoing carotid revascularization, using arterial spin labeling (ASL) cerebral blood flow (CBF) measurement as a reference. METHODS:In this retrospective stu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.10.004

    authors: Chen Z,Chen L,Shirakawa M,Liu W,Ortega D,Chen J,Balu N,Trouard T,Hatsukami TS,Zhou W,Yuan C

    更新日期:2021-01-01 00:00:00

  • Rapid and recoverable in vivo magnetic resonance imaging of the adult zebrafish at 7T.

    abstract::Increasing scientific interest in the zebrafish as a model organism across a range of biomedical and biological research areas raises the need for the development of in vivo imaging tools appropriate to this subject. Development of the embryonic and early stage forms of the subject can currently be assessed using opti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.013

    authors: Merrifield GD,Mullin J,Gallagher L,Tucker C,Jansen MA,Denvir M,Holmes WM

    更新日期:2017-04-01 00:00:00

  • Abdominal imaging studies: comparison of diagnostic accuracies resulting from ultrasound, computed tomography, and magnetic resonance imaging in the same individual.

    abstract::We retrospectively compared the diagnostic accuracy of abdominal ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI) studies performed on the same individual to determine the relative performance of these modalities in the evaluation of disease processes, arising from different intra-abdomi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.01.001

    authors: Noone TC,Semelka RC,Chaney DM,Reinhold C

    更新日期:2004-01-01 00:00:00

  • Hair product artifact in magnetic resonance imaging.

    abstract::The presence of metallic compounds in facial cosmetics and permanent tattoos may affect the quality of magnetic resonance imaging. We report a case study describing a signal artifact due to the use of a leave-on powdered hair dye. On reviewing the ingredients of the product, it was found to contain several metallic co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.08.023

    authors: Chenji S,Wilman AH,Mah D,Seres P,Genge A,Kalra S

    更新日期:2017-01-01 00:00:00

  • Fast and exact flow measurements with the fast Fourier flow technique.

    abstract::The fast Fourier flow technique offers a convenient way for extremely exact flow measurements. In combination with ECG gating, arterial flow can be studied. The total acquisition time for a single measurement is about 10 s, an ECG-gated cine sequence can be acquired in about 4 min. Fast Fourier flow can, therefore, be...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90473-0

    authors: Hennig J,Mueri M,Brunner P,Friedburg H

    更新日期:1988-07-01 00:00:00

  • GPU-accelerated nonparametric kinetic analysis of DCE-MRI data from glioblastoma patients treated with bevacizumab.

    abstract::Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is often used to examine vascular function in malignant tumors and noninvasively monitor drug efficacy of antivascular therapies in clinical studies. However, complex numerical methods used to derive tumor physiological properties from DCE-MRI images can b...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.09.007

    authors: Hsu YH,Ferl GZ,Ng CM

    更新日期:2013-05-01 00:00:00