Quantitative longitudinal fluid saturation profiles with a slice-selected CPMG sequence.

Abstract:

:A technique for obtaining quantitative longitudinal saturation/porosity profiles of rock cores which are longer than the NMR coil has been developed. The slice-selected experiment uses a prefocused pulse in conjunction with a magnetic field gradient for the localization and a CPMG sequence to sample the data. A variety of rock core samples has been studied ranging from limestones to shaly sandstones. Comparison of the relaxation decay curves obtained from these experiments and the bulk experiments show that reliable localized relaxation data are obtained.

journal_name

Magn Reson Imaging

authors

Pierens GK,Peyron M,Lucas AJ,Carpenter TA,Hall LD,Potter GF,Stewart RC,Phelps DW

doi

10.1016/0730-725x(94)91547-4

subject

Has Abstract

pub_date

1994-01-01 00:00:00

pages

323-4

issue

2

eissn

0730-725X

issn

1873-5894

pii

0730-725X(94)91547-4

journal_volume

12

pub_type

杂志文章
  • A preliminary study of blood-oxygen-level-dependent MRI in patients with chronic kidney disease.

    abstract:BACKGROUND:Blood-oxygen-level-dependent (BOLD) magnetic resonance imaging (MRI) can provide regional measurements of oxygen content using deoxyhemoglobin paramagnetic characteristics. The apparent relaxation rate or R2*(=1/T2*) can be determined from the slope of log (intensity) versus echo time and is directly proport...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.10.003

    authors: Xin-Long P,Jing-Xia X,Jian-Yu L,Song W,Xin-Kui T

    更新日期:2012-04-01 00:00:00

  • Analysis of time reduction methods for magnetic resonance elastography of the brain.

    abstract::Magnetic resonance elastography (MRE) uses a phase-contrast MRI technique to image shear wave propagation in tissue followed by the mathematical inversion of the equations of motion governing tissue mechanics to noninvasively image tissue stiffness. This work investigates the impact of various MR sampling strategies d...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.06.016

    authors: Murphy MC,Glaser KJ,Manduca A,Felmlee JP,Huston J 3rd,Ehman RL

    更新日期:2010-12-01 00:00:00

  • Computerized MRS voxel registration and partial volume effects in single voxel 1H-MRS.

    abstract::Partial volume effects in proton magnetic resonance spectroscopy in the brain have been studied previously in terms of proper water concentration calculations, but there is a lack of disclosure in terms of voxel placement techniques that would affect the calculations. The purpose of this study is to facilitate a fully...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.04.001

    authors: Lee H,Caparelli E,Li H,Mandal A,Smith SD,Zhang S,Bilfinger TV,Benveniste H

    更新日期:2013-09-01 00:00:00

  • Isotropically weighted intravoxel incoherent motion brain imaging at 7T.

    abstract::Perfusion magnetic resonance imaging (MRI) is a promising non-invasive technique providing insights regarding the brain's microvascular architecture in vivo. The scalar perfusion metrics can be used for quantitative diagnostics of various brain abnormalities, in particular, in the stroke cases and tumours. However, co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.11.007

    authors: Maximov II,Vellmer S

    更新日期:2019-04-01 00:00:00

  • A fast spin echo two-point Dixon technique and its combination with sensitivity encoding for efficient T2-weighted imaging.

    abstract::A fast spin echo two-point Dixon (fast 2PD) technique was developed for efficient T2-weighted imaging with uniform water and fat separation. The technique acquires two interleaved fast spin echo images with water and fat in-phase and 180 degrees out-of-phase, respectively, and generates automatically separate water an...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.005

    authors: Ma J,Son JB,Bankson JA,Stafford RJ,Choi H,Ragan D

    更新日期:2005-12-01 00:00:00

  • Lee-Goldburg solid-state imaging.

    abstract::A new approach to solid-state imaging (SSI) is presented. The method relies on narrowing the resonance line using the Lee-Goldburg sequence. The technique is easy to implement in practice and may find widespread applications in materials science. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90409-s

    authors: De Luca F,Lugeri N,De Simone BC,Maraviglia B

    更新日期:1992-01-01 00:00:00

  • Ovarian Brenner tumors: MR imaging characteristics.

    abstract::This study describes the appearance of Brenner tumors on MR imaging and compares quantitative signal intensity measurements of Brenner tumors with that of other ovarian tumors. A search of pathologic and MR records disclosed patients who had MRIs showing Brenner tumors prior to surgical excision. Patients (21) with ot...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0730-725x(98)00136-2

    authors: Outwater EK,Siegelman ES,Kim B,Chiowanich P,Blasbalg R,Kilger A

    更新日期:1998-12-01 00:00:00

  • Free-running simultaneous myocardial T1/T2 mapping and cine imaging with 3D whole-heart coverage and isotropic spatial resolution.

    abstract:PURPOSE:To develop a free-running framework for 3D isotropic simultaneous myocardial T1/T2 mapping and cine imaging. METHODS:Continuous data acquisition with 3D golden angle radial trajectory is used in conjunction with T2 preparation of varying echo times and inversion recovery (IR) pulses to enable simultaneous myoc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.08.008

    authors: Qi H,Bustin A,Cruz G,Jaubert O,Chen H,Botnar RM,Prieto C

    更新日期:2019-11-01 00:00:00

  • Effect of anesthesia on the signal intensity in tumors using BOLD-MRI: comparison with flow measurements by Laser Doppler flowmetry and oxygen measurements by luminescence-based probes.

    abstract::BOLD-contrast functional magnetic resonance imaging (MRI) was used to assess the evolution of tumor oxygenation and blood flow after administration of four different anesthetics: pentobarbital (60 mg/kg), ketamine/xylazine (80/8 mg/kg), fentanyl/droperidol (0.078/3.9 mg/kg), and isoflurane (1.5%). Gradient echo sequen...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.02.005

    authors: Baudelet C,Gallez B

    更新日期:2004-09-01 00:00:00

  • Biodistribution of GdCl3 and Gd-DTPA and their influence on proton magnetic relaxation in rat tissues.

    abstract::The biodistribution and relative molar effectiveness of the ionic (GdCl3) and chelated (Gd-DTPA) forms of gadolinium (Gd) to enhance proton relaxation rates in rat kidney, liver and spleen were evaluated. Rats were given intravenous injections of either GdCl3 (100 mumol/kg) or Gd-DTPA (178 mumol/kg). Gd-DTPA was prima...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90023-3

    authors: Barnhart JL,Kuhnert N,Bakan DA,Berk RN

    更新日期:1987-01-01 00:00:00

  • Multicontrast multiecho FLASH MRI for targeting the subthalamic nucleus.

    abstract::The subthalamic nucleus (STN) is one of the most common stimulation targets for treating Parkinson's disease using deep brain stimulation (DBS). This procedure requires precise placement of the stimulating electrode. Common practice of DBS implantation utilizes microelectrode recording to locate the sites with the cor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.02.006

    authors: Xiao Y,Beriault S,Pike GB,Collins DL

    更新日期:2012-06-01 00:00:00

  • Development and validation of a novel large field of view phantom and a software module for the quality assurance of geometric distortion in magnetic resonance imaging.

    abstract:OBJECTIVE:To develop and validate a large field of view phantom and quality assurance software tool for the assessment and characterization of geometric distortion in MRI scanners commissioned for radiation therapy planning. MATERIALS AND METHODS:A purpose built phantom was developed consisting of 357 rods (6mm in dia...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2015.04.003

    authors: Torfeh T,Hammoud R,McGarry M,Al-Hammadi N,Perkins G

    更新日期:2015-09-01 00:00:00

  • Prolonged T1 in patients with liver cirrhosis: an in vivo MRI study.

    abstract::Fifteen patients with liver cirrhosis and two control groups were examined. The first control group consisted of 7 healthy volunteers, and the second group of 17 patients with nonfocal liver diseases. The T1 and T2 relaxation times were calculated from signal intensities read out from a region of interest centrally lo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(90)90137-q

    authors: Thomsen C,Christoffersen P,Henriksen O,Juhl E

    更新日期:1990-01-01 00:00:00

  • Summary of special issue on gadolinium bioeffects and toxicity with a look to the future.

    abstract::This summary attempts to provide forward-looking concepts regarding gadolinium related toxicity, as discussed in further detail in this issue. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2016.09.002

    authors: Semelka RC,Ramalho M,Jay M

    更新日期:2016-12-01 00:00:00

  • In vivo T1 characterization of genetically induced muscle atrophy.

    abstract::In vivo spin-lattice relaxation times, T1, of water and lipid protons of normal and atrophic muscles were measured, using the spatially resolved spectroscopy (SPARS) sequence, in a genetic avian model of myopathy. These T1 values were compared with those of the hypertrophic muscles. Although the water T1 values of mus...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90550-x

    authors: Misra LK,Narayana PA

    更新日期:1989-05-01 00:00:00

  • Artifacts in chemical shift selective imaging.

    abstract::The role of susceptibility effects in the production of artifacts in chemical shift images generated by the selective excitation technique is discussed. The effects are demonstrated in images of phantom samples of agarose gels containing small air bubbles. The artifacts can lead to erroneous interpretations, in which ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90022-r

    authors: Pope JM,Walker RR,Kron T

    更新日期:1992-01-01 00:00:00

  • Trajectory correction for free-breathing radial cine MRI.

    abstract::Radial acquisitions can suffer from trajectory errors leading to reduced image quality. Here we present a new method of trajectory correction that uses all spokes of a radial acquisition and compare it to an existing method that uses a two-spoke pre-scan calibration. For both methods, estimates of the necessary shifts...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.04.006

    authors: Buonincontri G,Methner C,Krieg T,Carpenter TA,Sawiak SJ

    更新日期:2014-09-01 00:00:00

  • Empirical optimization of ASL data analysis using an ASL data processing toolbox: ASLtbx.

    abstract::Arterial spin labeling (ASL) perfusion fMRI data differ in important respects from the more familiar blood oxygen level-dependent (BOLD) fMRI data and require specific processing strategies. In this paper, we examined several factors that may influence ASL data analysis, including data storage bit resolution, motion c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.07.003

    authors: Wang Z,Aguirre GK,Rao H,Wang J,Fernández-Seara MA,Childress AR,Detre JA

    更新日期:2008-02-01 00:00:00

  • Abdominal imaging studies: comparison of diagnostic accuracies resulting from ultrasound, computed tomography, and magnetic resonance imaging in the same individual.

    abstract::We retrospectively compared the diagnostic accuracy of abdominal ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI) studies performed on the same individual to determine the relative performance of these modalities in the evaluation of disease processes, arising from different intra-abdomi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.01.001

    authors: Noone TC,Semelka RC,Chaney DM,Reinhold C

    更新日期:2004-01-01 00:00:00

  • Effect of slice orientation on reproducibility of fMRI motor activation at 3 Tesla.

    abstract::The effect of slice orientation on reproducibility and sensitivity of 3T fMRI activation using a motor task has been investigated in six normal volunteers. Four slice orientations were used; axial, oblique axial, coronal and sagittal. We applied analysis of variance (ANOVA) to suprathreshold voxel statistics to quanti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00399-x

    authors: Gustard S,Fadili J,Williams EJ,Hall LD,Carpenter TA,Brett M,Bullmore ET

    更新日期:2001-12-01 00:00:00

  • Analysis of microporosity and setting of reactive powder concrete by proton nuclear relaxation.

    abstract::The proton spin-lattice relaxation measured at several frequencies leads to a resolved distribution of four Tli for reactive powder concrete (RPC). The typical Tli frequency dependences are quantitatively interpreted by a biphasic fast exchange model and a proton nuclear relaxation of hydrated paramagnetic ions at the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00063-0

    authors: Philippot S,Korb JP,Petit D,Zanni H

    更新日期:1998-06-01 00:00:00

  • "MR conditional" respiratory ventilator system incident in a 3-T MRI environment.

    abstract::The misunderstanding of the labeling for an "MR conditional" respiratory ventilator system resulted in the placement of this device, which had substantial ferromagnetic components, too close to a 3-T magnetic resonance (MR) system, causing a projectile incident. Magnetic resonance imaging health care professionals sho...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.07.002

    authors: Greenberg KL,Weinreb J,Shellock FG

    更新日期:2011-10-01 00:00:00

  • Dixon-based fat-free MR-angiography compared to first pass and steady-state high-resolution MR-angiography using a blood pool contrast agent.

    abstract:INTRODUCTION:Compared to standard arterial-only first-pass MR-angiography (FPMRA), imaging during the equilibrium phase of a blood pool contrast agent (steady state) has been shown to provide higher image quality and better stenosis grading. Homogenous Dixon fat-suppression promises to increase contrast by suppression ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.07.005

    authors: Homsi R,Gieseke J,Kukuk GM,Träber F,Willinek WA,Schild HH,Hadizadeh DR

    更新日期:2015-11-01 00:00:00

  • Changes in the liver parenchyma after proton beam radiotherapy: evaluation with MR imaging.

    abstract::The objective of this study was to describe magnetic resonance (MR) findings with a 1.5T imager for hepatic parenchymal changes after proton beam radiotherapy. Thirty-two patients who received proton radiotherapy with doses of 50-87 Gy underwent MR imaging 1-75 months (mean 22 months) after the start of irradiation. A...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00152-1

    authors: Onaya H,Itai Y,Yoshioka H,Ahmadi T,Niitsu M,Okumura T,Akine Y,Matsuzaki Y,Doi M,Tsuji H,Tsujii H

    更新日期:2000-07-01 00:00:00

  • Susceptibility-matched envelope for the correction of EPI artifacts.

    abstract::Fast gradient echo sequences, such as echo planer imaging (EPI) and spiral imaging, are vulnerable to artifacts resulting from B(0) inhomogeneities. A major contribution to these artifacts is the susceptibility variation across the head, which is most severe in regions adjacent to air-tissue interfaces, such as the mo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.07.011

    authors: Neufeld A,Assaf Y,Graif M,Hendler T,Navon G

    更新日期:2005-11-01 00:00:00

  • Fast reconstruction of highly undersampled MR images using one and two dimensional principal component analysis.

    abstract::Recent compressed sensing techniques allow signal acquisition with less sampling than required by the Nyquist-Shannon theorem which reduces the data acquisition time in magnetic resonance imaging (MRI). However, prior knowledge becomes essential to reconstruct detailed features when the sampling rate is exceedingly lo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.10.009

    authors: Zong F,d'Eurydice MN,Galvosas P

    更新日期:2016-02-01 00:00:00

  • Quantifications of in vivo labeled stem cells based on measurements of magnetic moments.

    abstract::Cells labeled by super paramagnetic iron-oxide (SPIO) nanoparticles are more easily seen in gradient echo MR images, but it has not been shown that the amount of nanoparticles or the number of cells can be directly quantified from MR images. This work utilizes a previously developed and improved Complex Image Summatio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.08.003

    authors: Kokeny P,Cheng YN,Liu S,Xie H,Jiang Q

    更新日期:2017-01-01 00:00:00

  • Fast acceleration of ASL-based time-resolved magnetic resonance angiography by acquisition of control and labeled images in the same shot (fast ACTRESS): An optimization study.

    abstract:PURPOSE:To establish an optimized sequence design for fast acceleration of arterial spin labeling (ASL)-based time-resolved magnetic resonance angiography (MRA) by acquisition of control and labeled images in the same shot (fast ACTRESS) and a scan time of <1min, for the evaluation of intracranial vessels. MATERIALS A...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.07.026

    authors: Sugimori H,Fujima N,Suzuki Y,Hamaguchi H,Ishizaka K,Kudo K

    更新日期:2017-11-01 00:00:00

  • Functional magnetic resonance (fMR) imaging of a rat brain tumor model: implications for evaluation of tumor microvasculature and therapeutic response.

    abstract::Functional MR (fMR) imaging techniques based on blood oxygenation level dependent (BOLD) effects were developed and applied to a rat brain tumor model to evaluate the potential utility of the method for characterizing tumor growth and regression following treatment. Rats bearing 9L brain tumors in situ were imaged dur...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00208-2

    authors: Mazurchuk R,Zhou R,Straubinger RM,Chau RI,Grossman Z

    更新日期:1999-05-01 00:00:00

  • Three-dimensional magnetic resonance spectroscopic imaging of histologically confirmed brain tumors.

    abstract::The goal of this study was to determine whether presurgical metabolite levels measured by 3D MR Spectroscopic Imaging (MRSI) can accurately detect viable cancer within human brain tumor masses. A total of 31 patients (33 exams, 39 pathology correlations) with brain tumors were studied prior to surgical biopsy and/or r...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0730-725x(01)00225-9

    authors: Vigneron D,Bollen A,McDermott M,Wald L,Day M,Moyher-Noworolski S,Henry R,Chang S,Berger M,Dillon W,Nelson S

    更新日期:2001-01-01 00:00:00