Single-shot-double-echo EPI.

Abstract:

:Echo planar imaging (EPI) was extended for the acquisition of both, the spin-echo (SE) and the stimulated echo in a stimulated echo sequence after one excitation from thermal equilibrium. The two independent EPI images reflect different states of the transverse magnetization excited and measured almost simultaneously. This single-shot-double-echo EPI approach offers a variety of useful applications such as varying image contrast, obtaining flow or diffusion information, improving image resolution or circumventing T*2 requirements in single shot EPI. Benefits and limits of this technique are discussed.

journal_name

Magn Reson Imaging

authors

Börnert P,Jensen D

doi

10.1016/0730-725x(94)91234-n

subject

Has Abstract

pub_date

1994-01-01 00:00:00

pages

1033-8

issue

7

eissn

0730-725X

issn

1873-5894

pii

0730-725X(94)91234-N

journal_volume

12

pub_type

杂志文章
  • Abdominal imaging studies: comparison of diagnostic accuracies resulting from ultrasound, computed tomography, and magnetic resonance imaging in the same individual.

    abstract::We retrospectively compared the diagnostic accuracy of abdominal ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI) studies performed on the same individual to determine the relative performance of these modalities in the evaluation of disease processes, arising from different intra-abdomi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.01.001

    authors: Noone TC,Semelka RC,Chaney DM,Reinhold C

    更新日期:2004-01-01 00:00:00

  • In vivo MR evaluation of Gd-DTPA conjugated to dextran in normal rabbits.

    abstract::A dextran-Gd-DTPA compound has been recently synthesized utilizing 70,800 Da molecular weight dextran. This polymeric contrast agent for magnetic resonance imaging has been found chemically to be very stable and to demonstrate in vitro improved relaxivities of 1.5 to 2.3 times that of monomeric Gd-DTPA at 100 MHz. Thi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90515-2

    authors: Li KC,Quisling RG,Armitage FE,Richardson D,Mladinich C

    更新日期:1992-01-01 00:00:00

  • Dixon-based fat-free MR-angiography compared to first pass and steady-state high-resolution MR-angiography using a blood pool contrast agent.

    abstract:INTRODUCTION:Compared to standard arterial-only first-pass MR-angiography (FPMRA), imaging during the equilibrium phase of a blood pool contrast agent (steady state) has been shown to provide higher image quality and better stenosis grading. Homogenous Dixon fat-suppression promises to increase contrast by suppression ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.07.005

    authors: Homsi R,Gieseke J,Kukuk GM,Träber F,Willinek WA,Schild HH,Hadizadeh DR

    更新日期:2015-11-01 00:00:00

  • Balanced multi-image demons for non-rigid registration of magnetic resonance images.

    abstract::A new approach is introduced for non-rigid registration of a pair of magnetic resonance images (MRI). It is a generalization of the demons algorithm with low computational cost, based on local information augmentation (by integrating multiple images) and balanced implementation. Specifically, a single deformation that...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.09.013

    authors: Mesin L

    更新日期:2020-12-01 00:00:00

  • Evaluation of intracranial stenoses and aneurysms with accelerated 4D flow.

    abstract::The aim of this study was to evaluate intracranial arterial stenoses and aneurysms with accelerated time-resolved three-dimensional (3D) phase-contrast MRI or 4D flow. The 4D flow technique was utilized to image four normal volunteers, two patients with intracranial stenoses and two patients with intracranial aneurysm...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.042

    authors: Hope TA,Hope MD,Purcell DD,von Morze C,Vigneron DB,Alley MT,Dillon WP

    更新日期:2010-01-01 00:00:00

  • Finite element aided tracking of signal intensity changes in deforming intervertebral disc tissue.

    abstract::Tracking of signal intensity changes in soft tissue over time is often hampered by deformation of the tissue. In this study a method is described that uses finite element modeling to compensate for tissue deformation. The method is applied to the quantification of fluid redistribution in an intervertebral disc that de...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00251-8

    authors: Kingma I,Weinans H,van Dieën JH,de Boer RW

    更新日期:1998-01-01 00:00:00

  • In vivo31P-MRS of muscle bioenergetics in marine invertebrates: Future ocean limits scallops' performance.

    abstract:OBJECT:Dynamic in vivo31P-NMR spectroscopy in combination with Magnetic Resonance Imaging (MRI) was used to study muscle bioenergetics of boreal and Arctic scallops (Pecten maximus and Chlamys islandica) to test the hypothesis that future Ocean Warming and Acidification (OWA) will impair the performance of marine inver...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.06.003

    authors: Bock C,Wermter FC,Schalkhausser B,Blicher ME,Pörtner HO,Lannig G,Sejr MK

    更新日期:2019-09-01 00:00:00

  • Magnetic nanoparticle-induced hyperthermia treatment under magnetic resonance imaging.

    abstract::Super paramagnetic iron oxide Fe(3)O(4) nanoparticles prepared via photochemical reaction in pure form were used for inducing hyperthermia to treat subcutaneous Ehrlich carcinoma implanted in female mice. Our results indicate that the mean temperature profiles at the rectum, periphery of the tumor surface and at the c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.08.010

    authors: Elsherbini AA,Saber M,Aggag M,El-Shahawy A,Shokier HA

    更新日期:2011-02-01 00:00:00

  • Fast Field Echo imaging: an overview and contrast calculations.

    abstract::Current fast imaging techniques are based on gradient echo sequences with reduced flip angle excitation pulses and very short repetition times TR. Practical T2 values may be of the order of TR or longer. In this situation, a different image contrast can be obtained, depending on details of the sequence. Four essential...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(88)90472-9

    authors: van der Meulen P,Groen JP,Tinus AM,Bruntink G

    更新日期:1988-07-01 00:00:00

  • In vitro experiments on ICOSA6 4D flow MRI measurement for the quantification of velocity and turbulence parameters.

    abstract:PURPOSE:To perform comprehensive in vitro experiments using six-directional icosahedral flow encoding (ICOSA6) 4D flow magnetic resonance imaging (MRI) under various scan conditions to analyze the robustness of velocity and turbulence quantification. MATERIALS AND METHODS:In vitro flow phantoms with steady flow rates ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.06.020

    authors: Ha H,Park KJ,Dyverfeldt P,Ebbers T,Yang DH

    更新日期:2020-10-01 00:00:00

  • A new diagnostic approach to vascular rings and pulmonary slings: the role of MRI.

    abstract:UNLABELLED:The conventional diagnostic work-up of a patient suspected of having a vascular cause for stridor, or dysphagia, includes esophagography and bronchoscopy to delineate the abnormal structure without imaging the structure itself. Cine-angiography is regarded as the golden standard, but is not routinely perform...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00245-2

    authors: Beekman RP,Hazekamp MG,Sobotka MA,Meijboom EJ,de Roos A,Staalman CR,Beek FJ,Ottenkamp J

    更新日期:1998-01-01 00:00:00

  • In-plane flow velocity quantification along the phase encoding axis in MRI.

    abstract::In-plane flow quantification in MRI offers the potential for assessing vessel patency, and both volume flow rate and flow velocity. These techniques will have definite future impact on MR angiography. The method used in this paper employs motion artifact suppression technique (MAST) gradients to refocus spins travelli...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90409-2

    authors: Duerk JL,Pattany PM

    更新日期:1988-05-01 00:00:00

  • Artificial intelligence in medical imaging.

    abstract::The medical specialty radiology has experienced a number of extremely important and influential technical developments in the past that have affected how medical imaging is deployed. Artificial intelligence (AI) is potentially another such development that will introduce fundamental changes into the practice of radiol...

    journal_title:Magnetic resonance imaging

    pub_type: 社论

    doi:10.1016/j.mri.2019.12.006

    authors: Gore JC

    更新日期:2020-05-01 00:00:00

  • 1H magnetic resonance spectroscopy of the normal testis: preliminary findings.

    abstract:PURPOSE:The purpose of this study was to determine the pre- and postpubertal 1H magnetic resonance spectroscopic characteristics of the normal testis to establish baseline values for further clinical studies. MATERIALS AND METHODS:The subjects consisted of male volunteers, of whom 19 were prepubertal with ages between...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.06.008

    authors: Firat AK,Uğraş M,Karakaş HM,Erdem G,Kurus M,Ugras M,Celik T,Kahraman B,Doğanay S

    更新日期:2008-02-01 00:00:00

  • Tsallis-Entropy Segmentation through MRF and Alzheimer anatomic reference for Brain Magnetic Resonance Parcellation.

    abstract::Quantifying the intracranial tissue volume changes in magnetic resonance imaging (MRI) assists specialists to analyze the effects of natural or pathological changes. Since these changes can be subtle, the accuracy of the automatic compartmentalization method is always criticized by specialists. We propose and then eva...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.11.002

    authors: Azimbagirad M,Simozo FH,Senra Filho ACS,Murta Junior LO

    更新日期:2020-01-01 00:00:00

  • Considerations in applying 3D PRESS H-1 brain MRSI with an eight-channel phased-array coil at 3 T.

    abstract::The purpose of this study was to assess the benefits of a 3 T scanner and an eight-channel phased-array head coil for acquiring three-dimensional PRESS (Point REsolved Spectral Selection) proton (H-1) magnetic resonance spectroscopic imaging (MRSI) data from the brains of volunteers and patients with brain tumors rela...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.07.012

    authors: Li Y,Osorio JA,Ozturk-Isik E,Chen AP,Xu D,Crane JC,Cha S,Chang S,Berger MS,Vigneron DB,Nelson SJ

    更新日期:2006-12-01 00:00:00

  • A robust electrical conductivity imaging method with total variation and wavelet regularization.

    abstract:PURPOSE:This study aims to develop and evaluate a robust conductivity imaging method that combines total variation and wavelet regularization to enhance the accuracy of conductivity maps. THEORY AND METHODS:The proposed approach is based on a gradient-based method. The central equation is derived from Maxwell's equati...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.02.015

    authors: Sun X,Lu L,Qi L,Mei Y,Liu X,Chen W

    更新日期:2020-06-01 00:00:00

  • An intravascular loopless monopole antenna for vessel wall MR imaging at 3.0 T.

    abstract::The purpose of this study was to develop a novel intravascular loopless monopole antenna (ILMA) design specifically for imaging of small vessel walls. The ILMA consisted of an unshielded, low-friction guide wire and a tuning/matching box. The material of the guide wire was nitinol and it was coated with polyurethane. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.032

    authors: Yuan H,Lv X,Ma X,Zhang R,Fu Y,Yang X,Wang X,Zhang Z,Zhang J,Fang J

    更新日期:2013-01-01 00:00:00

  • Evaluation of a contraceptive device with MR imaging.

    abstract::The purpose of this investigation is to evaluate the positioning and to confirm the volume concept of the Lea's Shield diaphragm utilizing MR imaging. We evaluated the device in two women, one nulliparous and one multiparous. We were able to comprehensively evaluate the device in both patients and answer all questions...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00385-x

    authors: Maldjian C,Pelosi MA 2nd,Pelosi MA 3rd,Adam R

    更新日期:2001-06-01 00:00:00

  • Quantitative radial imaging of porous particles beds with varying water contents.

    abstract::Radial imaging protocols suitable for monitoring water transport in biopolymer and food materials during processes such as drying and rehydration are developed and tested on a well-characterized model sample. This model consisted of a randomly packed bed of Sephadex beads with varying water content. The results are in...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91238-r

    authors: Hills BP,Babonneau F

    更新日期:1994-01-01 00:00:00

  • Detection of viable myocardium in segments with fixed defects on thallium-201 scintigraphy: usefulness of magnetic resonance imaging early after acute myocardial infarction.

    abstract::To determine if magnetic resonance imaging (MRI) can be used to detect tissue viability in segments with persistent 201T1 defects early following acute myocardial infarction, 24 patients underwent MRI and adenosine 201T1 single photon emission computed tomography (SPECT) imaging at approximately 6 days. Infarction was...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90214-x

    authors: Johnston DL,Gupta VK,Wendt RE,Mahmarian JJ,Verani MS

    更新日期:1993-01-01 00:00:00

  • Quantitative multi-modal functional MRI with blood oxygenation level dependent exponential decays adjusted for flow attenuated inversion recovery (BOLDED AFFAIR).

    abstract::A magnetic resonance imaging (MRI) method is described that allows interleaved measurements of transverse (R(2)(*) and R(2)) and longitudinal (R(1)) relaxation rates of tissue water in conjunction with spin labeling. The image-contrasts are intrinsically blood oxygenation level dependent (BOLD) and cerebral blood flow...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00125-9

    authors: Hyder F,Renken R,Kennan RP,Rothman DL

    更新日期:2000-04-01 00:00:00

  • A new NOE-mediated MT signal at around -1.6ppm for detecting ischemic stroke in rat brain.

    abstract::In the present work, we reported a new nuclear Overhauser enhancement (NOE)-mediated magnetization transfer (MT) signal at around -1.6ppm (NOE(-1.6)) in rat brain and investigated its application in the detection of acute ischemic stroke in rodent model. Using continuous wave (CW) MT sequence, the NOE(-1.6) is reliabl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.05.002

    authors: Zhang XY,Wang F,Afzal A,Xu J,Gore JC,Gochberg DF,Zu Z

    更新日期:2016-10-01 00:00:00

  • Quantifying and comparing region-of-interest activation patterns in functional brain MR imaging: methodology considerations.

    abstract::The general aims of functional brain magnetic resonance imaging (fMRI) studies are to ascertain which areas of the brain are activated during a specific task, the extent of this activation, whether different groups of subjects demonstrate different patterns of activation, and how these groups behave in different tasks...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00278-6

    authors: Constable RT,Skudlarski P,Mencl E,Pugh KR,Fulbright RK,Lacadie C,Shaywitz SE,Shaywitz BA

    更新日期:1998-04-01 00:00:00

  • Effect of ovariectomy on contrast agent diffusion into lumbar intervertebral disc: a dynamic contrast-enhanced MRI study in female rats.

    abstract:PURPOSE:The purpose was to study the effect of estrogen deficiency on contrast agent diffusion into intervertebral disc in a rat model. MATERIALS AND METHODS:Seven-month-old female Sprague-Dawley rats were used. Fourteen rats had ovariectomy, and nine rats had sham surgery. Magnetic resonance imaging (MRI) of sagittal...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.01.001

    authors: Deng M,Griffith JF,Zhu XM,Poon WS,Ahuja AT,Wang YX

    更新日期:2012-06-01 00:00:00

  • Voxel-Wise Logistic Regression and Leave-One-Source-Out Cross Validation for white matter hyperintensity segmentation.

    abstract::Many algorithms have been proposed for automated segmentation of white matter hyperintensities (WMH) in brain MRI. Yet, broad uptake of any particular algorithm has not been observed. In this work, we argue that this may be due to variable and suboptimal validation data and frameworks, precluding direct comparison of ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.06.009

    authors: Knight J,Taylor GW,Khademi A

    更新日期:2018-12-01 00:00:00

  • The lever-coil: a simple, inexpensive sensor for respiratory and cardiac motion in MRI experiments.

    abstract::Thoracic and abdominal magnetic resonance imaging studies generally require some type of compensation for respiratory and cardiac motions in order to yield artifact-free images with good signal-to-noise ratio. Most techniques for respiratory compensation require the use of a non-NMR sensing device to monitor the subje...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00403-9

    authors: Fishbein KW,McConville P,Spencer RG

    更新日期:2001-07-01 00:00:00

  • Diffusion MRI detects longitudinal white matter changes in the 3xTg-AD mouse model of Alzheimer's disease.

    abstract::The sensitivity of multiple diffusion MRI (dMRI) parameters to longitudinal changes in white matter microstructure was investigated for the 3xTg-AD transgenic mouse model of Alzheimer's disease, which manifests both amyloid beta plaques and neurofibrillary tangles. By employing a specific dMRI method known as diffusio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.12.003

    authors: Nie X,Falangola MF,Ward R,McKinnon ET,Helpern JA,Nietert PJ,Jensen JH

    更新日期:2019-04-01 00:00:00

  • Breath-hold T2-weighted sequences of the liver: a comparison of four techniques at 1.0 and 1.5 T.

    abstract::T2-weighted images are considered the most sensitive for lesion detection at high field; however, long imaging time is problematic. Accordingly, the authors compared four breath-hold T2 or T2* weighted sequences comprising T2*-weighted FLASH, T2*-weighted PSIF, T2-weighted rapid spin echo (RASE), and T2-weighted Turbo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90371-6

    authors: Simm FC,Semelka RC,Recht M,Deimling M,Lenz G,Laub GA

    更新日期:1992-01-01 00:00:00

  • High resolution simultaneous imaging of intracranial and extracranial arterial wall with improved cerebrospinal fluid suppression.

    abstract:PURPOSE:To develop a technique for three dimensional (3D) high resolution joint imaging of intracranial and extracranial arterial walls with improved cerebrospinal fluid (CSF) suppression and good blood suppression based on T1 weighted sampling perfection with application optimized contrast using different angle evolut...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.08.004

    authors: Zhang L,Zhang N,Wu J,Liu X,Chung YC

    更新日期:2017-12-01 00:00:00