An intravascular loopless monopole antenna for vessel wall MR imaging at 3.0 T.

Abstract:

:The purpose of this study was to develop a novel intravascular loopless monopole antenna (ILMA) design specifically for imaging of small vessel walls. The ILMA consisted of an unshielded, low-friction guide wire and a tuning/matching box. The material of the guide wire was nitinol and it was coated with polyurethane. Because the guide wire was unshielded, it could be made thinner than the coaxial cable-based loopless intravascular antenna design. The material of the box was aluminum. In this study, the diameter of the guide wire was 0.5 mm and the length was 58.7 mm. The ILMA was used as a receiving antenna and body coil for transmission. To verify the feasibility of the ILMA, in vitro and in vivo experiments were performed on a 3.0-T magnetic resonance (MR) scanner. In vitro tests using the ILMA indicated that the proposed design could be used to image target vessel walls with a spatial resolution of 313 μm at the frequency coding direction and more than 100 mm of longitudinal coverage. In vivo tests demonstrated that the images showed the vessel walls clearly by using the ILMA and also indicated that the ILMA could be used for small vessels. The proposed antenna may therefore be utilized to promote MR-based diagnoses and therapeutic solutions for cardiovascular atherosclerotic diseases.

journal_name

Magn Reson Imaging

authors

Yuan H,Lv X,Ma X,Zhang R,Fu Y,Yang X,Wang X,Zhang Z,Zhang J,Fang J

doi

10.1016/j.mri.2012.06.032

subject

Has Abstract

pub_date

2013-01-01 00:00:00

pages

150-5

issue

1

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(12)00242-1

journal_volume

31

pub_type

杂志文章
  • Segmented diffusion-weighted imaging of the prostate: Application to transperineal in-bore 3T MR image-guided targeted biopsy.

    abstract:OBJECTIVE:This study aims to evaluate the applicability of using single-shot and multi-shot segmented diffusion-weighted imaging (DWI) techniques to support biopsy target localization in a cohort of targeted MRI-guided prostate biopsy patients. MATERIALS AND METHODS:Single-shot echo-planar diffusion-weighted imaging (...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.05.012

    authors: Fedorov A,Tuncali K,Panych LP,Fairhurst J,Hassanzadeh E,Seethamraju RT,Tempany CM,Maier SE

    更新日期:2016-10-01 00:00:00

  • A nonlinear regularization strategy for GRAPPA calibration.

    abstract::A regularization strategy is described for generalized autocalibrating partially parallel acquisition (GRAPPA) that allows successful calibration using a small number of autocalibration signals (ACS). The approach requires certain nonlinear relationships between the GRAPPA coefficients to be satisfied, which increases...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.05.005

    authors: Bydder M,Jung Y

    更新日期:2009-01-01 00:00:00

  • A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI. Part 1: Development of a computational method.

    abstract::Articular cartilage thickness is of relevance in various fields in diagnostics and biomedical research. In view of recent improvements of MR cartilage imaging a computational method has been developed for three-dimensional determination of cartilage thickness from tomographic datasets. A correction algorithm that comp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00012-x

    authors: Lösch A,Eckstein F,Haubner M,Englmeier KH

    更新日期:1997-01-01 00:00:00

  • Diffusion MRI detects longitudinal white matter changes in the 3xTg-AD mouse model of Alzheimer's disease.

    abstract::The sensitivity of multiple diffusion MRI (dMRI) parameters to longitudinal changes in white matter microstructure was investigated for the 3xTg-AD transgenic mouse model of Alzheimer's disease, which manifests both amyloid beta plaques and neurofibrillary tangles. By employing a specific dMRI method known as diffusio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.12.003

    authors: Nie X,Falangola MF,Ward R,McKinnon ET,Helpern JA,Nietert PJ,Jensen JH

    更新日期:2019-04-01 00:00:00

  • Fast Field Echo imaging: an overview and contrast calculations.

    abstract::Current fast imaging techniques are based on gradient echo sequences with reduced flip angle excitation pulses and very short repetition times TR. Practical T2 values may be of the order of TR or longer. In this situation, a different image contrast can be obtained, depending on details of the sequence. Four essential...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(88)90472-9

    authors: van der Meulen P,Groen JP,Tinus AM,Bruntink G

    更新日期:1988-07-01 00:00:00

  • Magic angle effect in magnetic resonance imaging of the Achilles tendon and enthesis.

    abstract::Collagen fibers in tendons and entheses are highly ordered. The protons within the bound water are subject to dipolar interactions whose strength depends on the orientation of the fibers to the static magnetic field B(0). Clinical pulse sequences have been employed to investigate this magic angle effect of the Achille...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.09.003

    authors: Du J,Pak BC,Znamirowski R,Statum S,Takahashi A,Chung CB,Bydder GM

    更新日期:2009-05-01 00:00:00

  • The effects of respiratory CO2 fluctuations in the resting-state BOLD signal differ between eyes open and eyes closed.

    abstract::Resting fluctuations in arterial CO2 (a cerebral vasodilator) are believed to be an important source of low-frequency blood oxygenation level dependent (BOLD) signal fluctuations. In this study we focus on the two commonly used resting-states in functional magnetic resonance imaging experiments, eyes open and eyes clo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.013

    authors: Peng T,Niazy R,Payne SJ,Wise RG

    更新日期:2013-04-01 00:00:00

  • Carotid plaque high-resolution MRI at 3 T: evaluation of a new imaging score for symptomatic plaque assessment.

    abstract:PURPOSE:To assess the sensitivity and specificity of intra-plaque hemorrhage (IPH), large lipid-rich necrotic core (LR-NC) and ulceration or cap rupture (UCR) for symptomatic carotid plaque characterization and to evaluate a new imaging score [Hemorrhage, Ulceration or cap rupture, Lipid-rich necrotic Core (HULC) score...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.04.024

    authors: Gury-Paquet L,Millon A,Salami F,Cernicanu A,Scoazec JY,Douek P,Boussel L

    更新日期:2012-12-01 00:00:00

  • Fast and high-resolution quantitative mapping of tissue water content with full brain coverage for clinically-driven studies.

    abstract::An efficient method for obtaining longitudinal relaxation time (T1) maps is based on acquiring two spoiled gradient recalled echo (SPGR) images in steady states with different flip angles, which has also been extended, with additional acquisitions, to obtain a tissue water content (M0) map. Several factors, including ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.08.001

    authors: Sabati M,Maudsley AA

    更新日期:2013-12-01 00:00:00

  • Reducing SAR in parallel excitation using variable-density spirals: a simulation-based study.

    abstract::Parallel excitation using multiple transmit channels has emerged as an effective method to shorten multidimensional spatially selective radiofrequency (RF) pulses, which have a number of important applications, including B1 field inhomogeneity correction in high-field MRI. The specific absorption rate (SAR) is a prima...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.02.003

    authors: Liu Y,Feng K,McDougall MP,Wright SM,Ji J

    更新日期:2008-10-01 00:00:00

  • Non-Gaussian diffusion MRI assessment of brain microstructure in mild cognitive impairment and Alzheimer's disease.

    abstract::We report the first application of a novel diffusion-based MRI method, called diffusional kurtosis imaging (DKI), to investigate changes in brain tissue microstructure in patients with mild cognitive impairment (MCI) and AD and in cognitively intact controls. The subject groups were characterized and compared in terms...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.02.008

    authors: Falangola MF,Jensen JH,Tabesh A,Hu C,Deardorff RL,Babb JS,Ferris S,Helpern JA

    更新日期:2013-07-01 00:00:00

  • Internal derangement of the temporomandibular joint: radiologic staging with clinical, surgical, and pathologic correlation.

    abstract::The radiologic findings from 60 patients with 86 internally deranged temporomandibular joints (TMJ) upon whom sequential imaging procedures had been performed over a period of two months to ten years were analyzed and correlated with clinical, surgical (72 joints), and pathological observations. Internal derangement o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90404-9

    authors: Schellhas KP

    更新日期:1989-09-01 00:00:00

  • Investigations of polymer dynamics in nanoporous media by field cycling NMR relaxometry and the dipolar correlation effect.

    abstract::The chain dynamics of short-chain perfluoropolyether melts confined in Vycor nanoporous media has been characterized by field cycling nuclear magnetic resonance relaxometry and the dipolar correlation effect. The slowdown of motions under confinement, leading to larger residual dipolar couplings, has been probed by lo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.11.018

    authors: Kausik R,Fatkullin N,Hüsing N,Kimmich R

    更新日期:2007-05-01 00:00:00

  • In vivo MR evaluation of Gd-DTPA conjugated to dextran in normal rabbits.

    abstract::A dextran-Gd-DTPA compound has been recently synthesized utilizing 70,800 Da molecular weight dextran. This polymeric contrast agent for magnetic resonance imaging has been found chemically to be very stable and to demonstrate in vitro improved relaxivities of 1.5 to 2.3 times that of monomeric Gd-DTPA at 100 MHz. Thi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90515-2

    authors: Li KC,Quisling RG,Armitage FE,Richardson D,Mladinich C

    更新日期:1992-01-01 00:00:00

  • Isotropically weighted intravoxel incoherent motion brain imaging at 7T.

    abstract::Perfusion magnetic resonance imaging (MRI) is a promising non-invasive technique providing insights regarding the brain's microvascular architecture in vivo. The scalar perfusion metrics can be used for quantitative diagnostics of various brain abnormalities, in particular, in the stroke cases and tumours. However, co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.11.007

    authors: Maximov II,Vellmer S

    更新日期:2019-04-01 00:00:00

  • Truncation artifact reduction in spectroscopic imaging using a dual-density spiral k-space trajectory.

    abstract::Truncation artifacts arise in magnetic resonance spectroscopic imaging (MRSI) of the human brain due to limited coverage of k-space necessitated by low SNR of metabolite signal and limited scanning time. In proton MRSI of the head, intense extra-cranial lipid signals "bleed" into brain regions, thereby contaminating s...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00608-2

    authors: Sarkar S,Heberlein K,Hu X

    更新日期:2002-12-01 00:00:00

  • Exchange dynamics of surfactants in adsorption layers investigated by PFG NMR diffusion.

    abstract::Surfactant adsorption layers on polystyrene latex particles are investigated concerning their equilibrium exchange dynamics with surfactant molecules in solution. Pulsed field gradient (PFG) nuclear magnetic resonance (NMR) self-diffusion measurements of the nonionic surfactant C12(EO)5 are performed, making use of th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00023-x

    authors: Schönhoff M,Söderman O

    更新日期:1998-06-01 00:00:00

  • Functional MR imaging of visual and motor cortex stimulation at high temporal resolution using a FLASH technique on a standard 1.5 Tesla scanner.

    abstract::Functional magnetic resonance imaging (fMRI) was performed on a conventional 1.5 T scanner by means of a modified FLASH-technique at temporal resolutions of 80 and 320 ms. The method's stability was assessed by phantom measurements and by investigation of three volunteers resulting in a low amplitude (3%) periodic (4 ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(96)00021-5

    authors: Wiener E,Schad LR,Baudendistel KT,Essig M,Müller E,Lorenz WJ

    更新日期:1996-01-01 00:00:00

  • Equivalent cross-relaxation rate imaging positively correlates with pathological grade and cell density of adipocytic tumors.

    abstract:OBJECTIVE:Equivalent cross-relaxation rate imaging (ECRI) is an MRI technique used to evaluate qualitative changes in protein-water interactions. We aimed to prospectively evaluate the utility of ECRI for classification of adipocytic tumors. MATERIALS AND METHODS:Institutional Review Board approval was obtained and al...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.12.004

    authors: Okuda H,Matsushima S,Sugiura H,Yamada K,Hamada S,Nishida Y,Ishiguro N

    更新日期:2014-04-01 00:00:00

  • MRI of the normal hippocampus.

    abstract::Before it is possible to use MR imaging to investigate changes in the hippocampus in disease processes such as epilepsy and memory disorders, it is imperative that normal variations are defined. Using specific anatomic locations, we evaluated the hippocampi of 29 normal volunteers with coronal MR studies. Mild variati...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90035-k

    authors: Bronen RA,Cheung G

    更新日期:1991-01-01 00:00:00

  • White matter abnormalities in children and adolescents with temporal lobe epilepsy.

    abstract:BACKGROUND AND PURPOSE:The widespread propagation of synchronized neuronal firing in seizure disorders may affect cortical and subcortical brain regions. Diffusion tensor imaging (DTI) can noninvasively quantify white matter integrity. The purpose of this study was to investigate the abnormal changes of white matter in...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.03.046

    authors: Meng L,Xiang J,Kotecha R,Rose D,Zhao H,Zhao D,Yang J,Degrauw T

    更新日期:2010-11-01 00:00:00

  • Correlations and dissociations between BOLD signal and P300 amplitude in an auditory oddball task: a parametric approach to combining fMRI and ERP.

    abstract::A parametric method is proposed to examine the relationship between neuronal activity, measured with event related potentials (ERPs), and the hemodynamic response, observed with functional magnetic resonance imaging (fMRI), during an auditory oddball paradigm. After verifying that the amplitude of the evoked response ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00496-4

    authors: Horovitz SG,Skudlarski P,Gore JC

    更新日期:2002-05-01 00:00:00

  • COmplex-Model-Based Estimation of thermal noise for fMRI data in the presence of artifacts.

    abstract::Due to the presence of artifacts induced by fast-imaging acquisition in functional magnetic resonance imaging (fMRI) studies, it is very difficult to estimate the variance of thermal noise by traditional methods in magnitude images. Moreover, the existence of incidental phase fluctuations impairs the validity of curre...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.12.007

    authors: Xu Y,Wu G,Rowe DB,Ma Y,Zhang R,Xu G,Li SJ

    更新日期:2007-09-01 00:00:00

  • Monitoring of task performance during functional magnetic resonance imaging of sensorimotor cortex at 1.5 T.

    abstract::Functional magnetic resonance imaging (fMRI) has found widespread clinical interest. Difficulties in clinical use of the fMRI technique arise, considering the lack of knowledge about activation task performance. This accounts especially for sensorimotor activation studies, in which performance of the sensorimotor acti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02052-u

    authors: Baudendistel K,Schad LR,Wenz F,Essig M,Schröder J,Jahn T,Knopp MV,Lorenz WJ

    更新日期:1996-01-01 00:00:00

  • A functionalized superparamagnetic iron oxide colloid as a receptor directed MR contrast agent.

    abstract::We have synthesized a surface functionalized superparamagnetic iron oxide colloid whose clearance from the vascular compartment was inhibited by asialofetuin but not fetuin. Unlike other particulate or colloidal magnetic resonance (MR) contrast agents, the agent of the current communication is not withdrawn from the v...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90143-p

    authors: Josephson L,Groman EV,Menz E,Lewis JM,Bengele H

    更新日期:1990-01-01 00:00:00

  • Assessment of cardiac iron by MRI susceptometry and R2* in patients with thalassemia.

    abstract::A magnetic resonance imaging cardiac magnetic susceptometry (MRI-CS) technique for assessing cardiac tissue iron concentration based on phase mapping was developed. Normal control subjects (n=9) and thalassemia patients (n=13) receiving long-term blood transfusion therapy underwent MRI-CS and MRI measurements of the c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.12.001

    authors: Wang ZJ,Fischer R,Chu Z,Mahoney DH Jr,Mueller BU,Muthupillai R,James EB,Krishnamurthy R,Chung T,Padua E,Vichinsky E,Harmatz P

    更新日期:2010-04-01 00:00:00

  • Arterial input functions (AIFs) measured directly from arteries with low and standard doses of contrast agent, and AIFs derived from reference tissues.

    abstract::Measurements of arterial input function (AIF) can have large systematic errors at standard contrast agent doses in dynamic contrast enhanced MRI (DCE-MRI). We compared measured AIFs from low dose (AIFLD) and standard dose (AIFSD) contrast agent injections, as well as the AIF derived from a muscle reference tissue and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.10.025

    authors: Wang S,Fan X,Medved M,Pineda FD,Yousuf A,Oto A,Karczmar GS

    更新日期:2016-02-01 00:00:00

  • A new RF transmit coil for foot and ankle imaging at 7T MRI.

    abstract::A four-channel Tic-Tac-Toe (TTT) transmit RF coil was designed and constructed for foot and ankle imaging at 7T MRI. Numerical simulations using an in-house developed FDTD package and experimental analyses using a homogenous phantom show an excellent agreement in terms of B1+ field distribution and s-parameters. Simul...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.09.005

    authors: Santini T,Kim J,Wood S,Krishnamurthy N,Farhat N,Maciel C,Raval SB,Zhao T,Ibrahim TS

    更新日期:2018-01-01 00:00:00

  • Mri measurements of T1, T2 and D for gels undergoing volume phase transition.

    abstract::Gels consist of crosslinked polymer network swollen in solvent. The network of flexible long-chain molecules traps the liquid medium they are immersed in. Some gels undergo abrupt volume change, a phase transition process, by swelling-shrinking in response to external stimuli changes in solvent composition, temperatur...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00639-2

    authors: Yung KT

    更新日期:2003-02-01 00:00:00

  • SmartPhantom--an fMRI simulator.

    abstract::Many informatics tools have emerged to process the voluminous and complex data generated by functional magnetic resonance imaging (fMRI). The interpretation of fMRI exams is largely determined by these tools. However, their performance is hard to evaluate because there is no independent means of calibration. A novel f...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.012

    authors: Cheng H,Zhao Q,Duensing GR,Edelstein WA,Spencer D,Browne N,Saylor C,Limkeman M

    更新日期:2006-04-01 00:00:00