Semi-automatic lung segmentation of DCE-MRI data sets of 2-year old children after congenital diaphragmatic hernia repair: Initial results.

Abstract:

:In congenital diaphragmatic hernia (CDH), lung hypoplasia and secondary pulmonary hypertension are the major causes of death and severe disability. Based on new therapeutic strategies survival rates could be improved to up to 80%. However, after surgical repair of CDH, long-term follow-up of these pediatric patients is necessary. In this, dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides insights into the pulmonary microcirculation and might become a tool within the routine follow-up program of CDH patients. However, whole lung segmentation from DCE-MRI scans is tedious and automated procedures are warranted. Therefore, in this study, an approach to semi-automated lung segmentation is presented. Segmentation of the lung is obtained by calculating the cross correlation and the area under curve between all voxels in the data set and a reference region-of-interest (ROI), here the arterial input function (AIF). By applying an upper and lower threshold to the obtained maps and intersecting these, a final segmentation is reached. This approach was tested on twelve DCE-MRI data sets of 2-year old children after CDH repair. Segmentation accuracy was evaluated by comparing obtained automatic segmentations to manual delineations using the Dice overlap measure. Optimal thresholds for the cross correlation were 0.5/0.95 and 0.1/0.5 for the area under curve, respectively. The ipsilateral (left) lung showed reduced segmentation accuracy compared to the contralateral (right) lung. Average processing time was about 1.4s per data set. Average Dice score was 0.7±0.1 for the whole lung. In conclusion, initial results are promising. By our approach, whole lung segmentation is possible and a rapid evaluation of whole lung perfusion becomes possible. This might allow for a more detailed analysis of lung hypoplasia of children after CDH.

journal_name

Magn Reson Imaging

authors

Zöllner FG,Daab M,Weidner M,Sommer V,Zahn K,Schaible T,Weisser G,Schoenberg SO,Neff KW,Schad LR

doi

10.1016/j.mri.2015.08.003

subject

Has Abstract

pub_date

2015-12-01 00:00:00

pages

1345-1349

issue

10

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(15)00196-4

journal_volume

33

pub_type

杂志文章
  • Identification of an optimal threshold for detecting human brown adipose tissue using receiver operating characteristic analysis of IDEAL MRI fat fraction maps.

    abstract:PURPOSE:Lower fat fraction (FF) in brown adipose tissue (BAT) than white adipose tissue (WAT) has been exploited using Dixon-based Magnetic Resonance Imaging (MRI) to differentiate these tissues in rodents, human infants and adults. We aimed to determine whether an optimal FF threshold could be determined to differenti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.04.013

    authors: Jones TA,Wayte SC,Reddy NL,Adesanya O,Dimitriadis GK,Barber TM,Hutchinson CE

    更新日期:2018-09-01 00:00:00

  • Quantitative computer-assisted analysis vs. visual estimation of MR imaging response of brain metastases to radiotherapy.

    abstract::Using both quantitative computer-assisted analysis and visual estimation the MR imaging response of brain metastases to whole-brain radiotherapy (WBRT) was prospectively studied in 49 patients. Compared to the computer-assisted analysis, the precision of the visual estimation (by two readers in conference) of tumor re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00024-0

    authors: Taphoorn MJ,Potman RA,Barkhof F,Weerts JG,Valk J,Karim AB,Heimans JJ

    更新日期:1997-01-01 00:00:00

  • Theoretical considerations in measurement of time discrepancies between input and myocardial time-signal intensity curves in estimates of regional myocardial perfusion with first-pass contrast-enhanced MRI.

    abstract::The purpose of this study was to develop a method to determine time discrepancies between input and myocardial time-signal intensity (TSI) curves for accurate estimation of myocardial perfusion with first-pass contrast-enhanced MRI. Estimation of myocardial perfusion with contrast-enhanced MRI using kinetic models req...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.06.015

    authors: Natsume T,Ishida M,Kitagawa K,Nagata M,Sakuma H,Ichihara T

    更新日期:2015-11-01 00:00:00

  • Utility of magnetization prepared GRE MRI for the detection of focal liver lesions.

    abstract::We compared the efficacy of rapidly acquired magnetization prepared gradient-echo (MP-GRE) sequences with CT and standard MRI pulse sequences for the detection of focal liver lesions. Fourteen patients with 28 focal liver lesions were scanned. TI times of 300, 450, and 600 ms were used. MP-GRE lesion conspicuity was c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92198-9

    authors: Winter TC 3rd,Freeny PC,Nghiem HV,Thomas CR Jr

    更新日期:1994-01-01 00:00:00

  • Chemical exchange saturation transfer MR imaging of articular cartilage glycosaminoglycans at 3 T: Accuracy of B0 Field Inhomogeneity corrections with gradient echo method.

    abstract::Glycosaminoglycan Chemical Exchange Saturation Transfer (gagCEST) is an important molecular MRI methodology developed to assess changes in cartilage GAG concentrations. The correction for B0 field inhomogeneity is technically crucial in gagCEST imaging. This study evaluates the accuracy of the B0 estimation determined...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.009

    authors: Wei W,Jia G,Flanigan D,Zhou J,Knopp MV

    更新日期:2014-01-01 00:00:00

  • Three-dimensional magnetic resonance spectroscopic imaging of histologically confirmed brain tumors.

    abstract::The goal of this study was to determine whether presurgical metabolite levels measured by 3D MR Spectroscopic Imaging (MRSI) can accurately detect viable cancer within human brain tumor masses. A total of 31 patients (33 exams, 39 pathology correlations) with brain tumors were studied prior to surgical biopsy and/or r...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0730-725x(01)00225-9

    authors: Vigneron D,Bollen A,McDermott M,Wald L,Day M,Moyher-Noworolski S,Henry R,Chang S,Berger M,Dillon W,Nelson S

    更新日期:2001-01-01 00:00:00

  • Simple phase method for measurement of magnetic field gradient waveforms.

    abstract::Magnetic field gradients play a fundamental role in MR imaging and localized spectroscopy. The MRI experiment, in particular fast MRI, relies on precise gradient switching, which has become more demanding with the constantly growing number of fast imaging techniques. Here we present a simple MR method to measure the b...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.02.002

    authors: Latta P,Gruwel ML,Volotovskyy V,Weber MH,Tomanek B

    更新日期:2007-11-01 00:00:00

  • Idiopathic dilatation of the pulmonary artery: report of four cases.

    abstract::Idiopathic dilatation of the pulmonary artery (IDPA) is a rare congenital disease which is usually detected fortuitously on chest x-ray, thus radiologists must be aware of this clinical entity. This report describes four cases to which Magnetic Resonance Imaging (MRI) played a major role in diagnosing IDPA and in dete...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00013-2

    authors: Ugolini P,Mousseaux E,Sadou Y,Sidi D,Mercier LA,Paquet E,Gaux JC

    更新日期:1999-07-01 00:00:00

  • Radiofrequency magnetic field gradient echoes have reduced sensitivity to susceptibility gradients.

    abstract::The amplitudes of gradient-echoes produced using static field gradients are sensitive to diffusion of tissue water during the echo evolution time. Gradient-echoes have been used to produce MR images in which image intensity is proportional to the self-diffusion coefficient of water. However, such measurements are subj...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00051-h

    authors: Karczmar G,River J,Koretsky AP

    更新日期:1995-01-01 00:00:00

  • Diffusional kurtosis imaging of cingulate fibers in Parkinson disease: comparison with conventional diffusion tensor imaging.

    abstract:OBJECTIVE:The pathological changes in Parkinson disease begin in the brainstem; reach the limbic system and ultimately spread to the cerebral cortex. In Parkinson disease (PD) patients, we evaluated the alteration of cingulate fibers, which comprise part of the limbic system, by using diffusional kurtosis imaging (DKI)...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.06.009

    authors: Kamagata K,Tomiyama H,Motoi Y,Kano M,Abe O,Ito K,Shimoji K,Suzuki M,Hori M,Nakanishi A,Kuwatsuru R,Sasai K,Aoki S,Hattori N

    更新日期:2013-11-01 00:00:00

  • The lever-coil: a simple, inexpensive sensor for respiratory and cardiac motion in MRI experiments.

    abstract::Thoracic and abdominal magnetic resonance imaging studies generally require some type of compensation for respiratory and cardiac motions in order to yield artifact-free images with good signal-to-noise ratio. Most techniques for respiratory compensation require the use of a non-NMR sensing device to monitor the subje...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00403-9

    authors: Fishbein KW,McConville P,Spencer RG

    更新日期:2001-07-01 00:00:00

  • Segmented diffusion-weighted imaging of the prostate: Application to transperineal in-bore 3T MR image-guided targeted biopsy.

    abstract:OBJECTIVE:This study aims to evaluate the applicability of using single-shot and multi-shot segmented diffusion-weighted imaging (DWI) techniques to support biopsy target localization in a cohort of targeted MRI-guided prostate biopsy patients. MATERIALS AND METHODS:Single-shot echo-planar diffusion-weighted imaging (...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.05.012

    authors: Fedorov A,Tuncali K,Panych LP,Fairhurst J,Hassanzadeh E,Seethamraju RT,Tempany CM,Maier SE

    更新日期:2016-10-01 00:00:00

  • Multispectral analysis of bone lesions in the hands of patients with rheumatoid arthritis.

    abstract::Quantitative measures of rheumatoid arthritis (RA) disease progression can provide valuable tools for evaluation of new treatments during clinical trials. In this study, a novel multispectral (MS) MRI analysis method is presented to quantify changes in bone lesion volume (DeltaBLV) in the hands of RA patients. Image r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.013

    authors: Carano RA,Lynch JA,Redei J,Ostrowitzki S,Miaux Y,Zaim S,White DL,Peterfy CG,Genant HK

    更新日期:2004-05-01 00:00:00

  • Simultaneous PET-MRI in oncology: a solution looking for a problem?

    abstract::With the recent development of integrated positron emission tomography-magnetic resonance imaging (PET-MRI) scanners, new possibilities for quantitative molecular imaging of cancer are realized. However, the practical advantages and potential clinical benefits of the ability to record PET and MRI data simultaneously m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2012.06.001

    authors: Yankeelov TE,Peterson TE,Abramson RG,Izquierdo-Garcia D,Arlinghaus LR,Li X,Atuegwu NC,Catana C,Manning HC,Fayad ZA,Gore JC

    更新日期:2012-11-01 00:00:00

  • Reproducibility of simultaneous imaging of intracranial and extracranial arterial vessel walls using an improved T1-weighted DANTE-SPACE sequence on a 3 T MR system.

    abstract:PURPOSE:To systematically investigate the scan-rescan, intra-observer, and inter-observer reproducibility of an improved DANTE-SPACE sequence for the simultaneous assessment of intra- and extracranial arterial vessel wall morphology. MATERIALS AND METHODS:Thirty-five healthy volunteers and 10 patients with atheroscler...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.04.016

    authors: Wan L,Zhang N,Zhang L,Long X,Jia S,Li Y,Liang D,Zheng H,Liu X

    更新日期:2019-10-01 00:00:00

  • An intravascular loopless monopole antenna for vessel wall MR imaging at 3.0 T.

    abstract::The purpose of this study was to develop a novel intravascular loopless monopole antenna (ILMA) design specifically for imaging of small vessel walls. The ILMA consisted of an unshielded, low-friction guide wire and a tuning/matching box. The material of the guide wire was nitinol and it was coated with polyurethane. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.032

    authors: Yuan H,Lv X,Ma X,Zhang R,Fu Y,Yang X,Wang X,Zhang Z,Zhang J,Fang J

    更新日期:2013-01-01 00:00:00

  • Exchange dynamics of surfactants in adsorption layers investigated by PFG NMR diffusion.

    abstract::Surfactant adsorption layers on polystyrene latex particles are investigated concerning their equilibrium exchange dynamics with surfactant molecules in solution. Pulsed field gradient (PFG) nuclear magnetic resonance (NMR) self-diffusion measurements of the nonionic surfactant C12(EO)5 are performed, making use of th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00023-x

    authors: Schönhoff M,Söderman O

    更新日期:1998-06-01 00:00:00

  • Simultaneous recording of neuronal signals and functional NMR imaging.

    abstract::We recently directly examined the relationship between blood-oxygen-level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signals and neural activity by simultaneously acquiring electrophysiological and fMRI data from monkeys in a 4.7-T vertical scanner (Logothetis NK, Pauls J, Augath MA, Trinath T, Oelt...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.015

    authors: Oeltermann A,Augath MA,Logothetis NK

    更新日期:2007-07-01 00:00:00

  • Fast T2-mapping with snapshot flash imaging.

    abstract::It has been shown recently that quantitative T2-maps may be measured by acquisition of a series of at least eight T2-weighted SNAPSHOT FLASH images. These measurements require a relaxation delay of 10-15 s after each T2-weighted image for the complete relaxation of the spin system. This results in long measuring times...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00004-z

    authors: Deichmann R,Adolf H,Nöth U,Morrissey S,Schwarzbauer C,Haase A

    更新日期:1995-01-01 00:00:00

  • MRI-assisted radiation therapy planning of brain tumors--clinical experiences in 17 patients.

    abstract::A new and simple method for precise determination of lateral opposed treatment portals was developed and used in 17 patients. Compared to CT, MRI led to significant changes of portals in 59% (10/17) of cases. Individual shielding blocks could be precisely designed by use of our new method. MRI is the procedure of choi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90007-9

    authors: Just M,Rösler HP,Higer HP,Kutzner J,Thelen M

    更新日期:1991-01-01 00:00:00

  • Assessing the effect of football play on knee articular cartilage using delayed gadolinium-enhanced MRI of cartilage (dGEMRIC).

    abstract::The prevalence of cartilage lesions is much higher in football athletes than in the general population. Delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) has been shown to quantify regional variations of glycosaminoglycan (GAG) concentrations which is an indicator of early cartilage degeneration. The goal of this...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.01.008

    authors: Wei W,Lambach B,Jia G,Flanigan D,Chaudhari AMW,Wei L,Rogers A,Payne J,Siston RA,Knopp MV

    更新日期:2017-06-01 00:00:00

  • Electrophoretic NMR studies of electrical transport in fluid-filled porous systems.

    abstract::An NMR technique is described which allows the observation of ionic charge carriers moving in the electric field within a porous system saturated with electrolyte solution. This method, which was recently developed in our laboratory, gives experimental access to the study of electric transport in disordered media on a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00267-3

    authors: Holz M,Heil SR,Schwab IA

    更新日期:2001-04-01 00:00:00

  • Characteristics of geometric distortion correction with increasing field-of-view in open-configuration MRI.

    abstract::Open-configuration magnetic resonance imaging (MRI) systems are becoming increasingly desirable for musculoskeletal imaging and image-guided radiotherapy because of their non-claustrophobic configuration. However, geometric image distortion in large fields-of-view (FOV) due to field inhomogeneity and gradient nonlinea...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.02.007

    authors: Hong C,Lee DH,Han BS

    更新日期:2014-07-01 00:00:00

  • MR microscopy of micron scale structures.

    abstract::Magnetic resonance (MR) microscopy of up to 1-5-microm resolutions have been reported previously. The tested phantom structures, however, had widths one order of magnitude bigger than the reported resolutions, e.g., spherical beads or capillary tubes of tens-of-micron diameters or wall thicknesses have been imaged. In...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.01.002

    authors: Lee SC,Kim K,Kim J,Yi JH,Lee S,Cheong C

    更新日期:2009-07-01 00:00:00

  • The influence of stimulated echoes on contrast in fast spin-echo imaging.

    abstract::Tissue contrast obtained using fast spin-echo (FSE) and conventional spin-echo (SE) sequences is not identical and a number of mechanisms are thought to contribute to these contrast differences. The effect of stimulated echoes has previously been apparently ruled out as a contributing mechanism. Signal-to-noise ratios...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02110-f

    authors: Williams CF,Redpath TW,Smith FW

    更新日期:1996-01-01 00:00:00

  • The comparison of the performance of 3 T and 7 T T2 mapping for untreated low-grade cartilage lesions.

    abstract:OBJECTIVE:To investigate T2 mapping as a possible marker for low-grade human articular cartilage lesions during a one-year follow-up, possible changes during the follow-up and compare the reliability and sensitivity of these measurements on high-field (3 T) and ultra-high-field (7 T) MRI scanners. DESIGN:Twenty-one pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.09.021

    authors: Juras V,Schreiner M,Laurent D,Zbýň Š,Mlynarik V,Szomolanyi P,Hager B,Scotti C,Goldhahn J,Heule R,Bieri O,Trattnig S

    更新日期:2019-01-01 00:00:00

  • The precision of DCE-MRI using the tissue homogeneity model with continuous formulation of the perfusion parameters.

    abstract::The present trend in dynamic contrast-enhanced MRI is to increase the number of estimated perfusion parameters using complex pharmacokinetic models. However, less attention is given to the precision analysis of the parameter estimates. In this paper, the distributed capillary adiabatic tissue homogeneity pharmacokinet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.02.003

    authors: Bartoš M,Jiřík R,Kratochvíla J,Standara M,Starčuk Z Jr,Taxt T

    更新日期:2014-06-01 00:00:00

  • Three-dimensional adiabatic inversion recovery prepared ultrashort echo time cones (3D IR-UTE-Cones) imaging of cortical bone in the hip.

    abstract:PURPOSE:We present three-dimensional adiabatic inversion recovery prepared ultrashort echo time Cones (3D IR-UTE-Cones) imaging of cortical bone in the hip of healthy volunteers using a clinical 3T scanner. METHODS:A 3D IR-UTE-Cones sequence, based on a short pulse excitation followed by a 3D Cones trajectory, with a ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.07.012

    authors: Nazaran A,Carl M,Ma Y,Jerban S,Zhu Y,Lu X,Du J,Chang EY

    更新日期:2017-12-01 00:00:00

  • Diffusion MRI with Semi-Automated Segmentation Can Serve as a Restricted Predictive Biomarker of the Therapeutic Response of Liver Metastasis.

    abstract:PURPOSE:To assess the value of semi-automated segmentation applied to diffusion MRI for predicting the therapeutic response of liver metastasis. METHODS:Conventional diffusion weighted magnetic resonance imaging (MRI) was performed using b-values of 0, 150, 300 and 450s/mm(2) at baseline and days 4, 11 and 39 followin...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.08.006

    authors: Stephen RM,Jha AK,Roe DJ,Trouard TP,Galons JP,Kupinski MA,Frey G,Cui H,Squire S,Pagel MD,Rodriguez JJ,Gillies RJ,Stopeck AT

    更新日期:2015-12-01 00:00:00

  • Rapid assessment of regional and global left ventricular function using three-dimensional k-t BLAST imaging.

    abstract:OBJECTIVE:To test if three-dimensional (3D) cine spatial frequency-temporal frequency Broad-use Linear Acquisition Speed-up Technique (k-t BLAST) is suitable for rapid evaluation of global and regional left ventricular (LV) functional parameters and to evaluate the influence of gadolinium administration. MATERIALS AND...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.01.027

    authors: Huber S,Muthupillai R,Mojibian H,Cheong B,Kouwenhoven M,Flamm SD

    更新日期:2008-07-01 00:00:00