A proposal for a semiquantitative scoring system for lymphedema using Non-contrast Magnetic Resonance Lymphography (NMRL): Reproducibility among readers and correlation with clinical grading.

Abstract:

PURPOSE:To assess the ability and reproducibility of Non-contrast Magnetic Resonance Lymphography (NMRL) in detecting and quantify lymphedema, using a semiquantitative scoring system. METHODS AND MATERIAL:This is a monocentric retrospective study of 134 consecutive patients with a clinical diagnosis of limb lymphedema who performed a Non-contrast Magnetic Resonance Lymphography (NMRL) at our Institution between November 2014 and February 2017. Lymphedema was classified based both on clinical and radiologic evaluation. An NMRL total score was obtained for each limb's segment and compared to the clinical grade, used as reference standard. NMRL intra-observer, inter-observer variability and intraclass correlation were calculated. NMRL sensitivity, specificity, and accuracy in identifying lymphedema were provided. Based on score distribution an NMRL four-stage system was developed. RESULTS:NMRL showed 92% sensitivity, 77% specificity and 82% accuracy in identifying lymphedema. An almost perfect agreement was obtained by expert operators, while substantial agreement was obtained by non-expert operators. Substantial agreement resulted also for the inter-observer variability (Cohen's Kappa K = 0.73, CI 95% [0.69-0.78]). The intra-class correlation showed an almost perfect relationship both by expert and non-expert operators. Excellent correlation between clinical grade and NMRL score and between clinical grade and NMRL stage were found for each segment. CONCLUSIONS:NMRL is a confident and reproducible exam with high sensitivity, good specificity and high accuracy in lymphedema detection; the semiquantitative NMRL score resulted a reliable and reproducible tool able to quantify lymphedema severity.

journal_name

Magn Reson Imaging

authors

Franconeri A,Ballati F,Panzuto F,Raciti MV,Smedile A,Maggi A,Asteggiano C,Esposito M,Stoppa D,Lungarotti L,Bortolotto C,Giardini D,De Silvestri A,Calliada F

doi

10.1016/j.mri.2020.02.004

subject

Has Abstract

pub_date

2020-05-01 00:00:00

pages

158-166

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(19)30582-X

journal_volume

68

pub_type

杂志文章
  • Pure uterine lipoma.

    abstract::Lipomatous tumors of the uterus are unusual, benign neoplasms seen in postmenopausal women. Although many of the mixed-type cases such as lipoleiomyoma and fibrolipoma have been reported, pure uterine lipomas are extremely rare. In the literature, a few cases with pure uterine lipoma have been reported. We first prese...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.01.116

    authors: Erdem G,Celik O,Karakas HM,Alkan A,Hascalik S

    更新日期:2007-10-01 00:00:00

  • Multi-parametric MRI of the physiology and optics of the in-vivo mouse lens.

    abstract::The optics of the ocular lens are determined by its geometry (shape and volume) and its inherent gradient of refractive index (water to protein ratio), which are in turn maintained by unique cellular physiology known as the lens internal microcirculation system. Previously, magnetic resonance imaging (MRI) has been us...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.04.015

    authors: Muir ER,Pan X,Donaldson PJ,Vaghefi E,Jiang Z,Sellitto C,White TW

    更新日期:2020-07-01 00:00:00

  • Truncation artifact reduction in spectroscopic imaging using a dual-density spiral k-space trajectory.

    abstract::Truncation artifacts arise in magnetic resonance spectroscopic imaging (MRSI) of the human brain due to limited coverage of k-space necessitated by low SNR of metabolite signal and limited scanning time. In proton MRSI of the head, intense extra-cranial lipid signals "bleed" into brain regions, thereby contaminating s...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00608-2

    authors: Sarkar S,Heberlein K,Hu X

    更新日期:2002-12-01 00:00:00

  • High-resolution in vivo diffusion tensor imaging of the injured cat spinal cord using self-navigated, interleaved, variable-density spiral acquisition (SNAILS-DTI).

    abstract::Diffusion tensor magnetic resonance imaging (DTI) is useful for studying the microstructural changes in the spinal cord following traumatic injury; however, image quality is generally poor due to the small size of the spinal cord, physiological motion and susceptibility artifacts. Self-navigated, interleaved, variable...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.06.006

    authors: Ellingson BM,Sulaiman O,Kurpad SN

    更新日期:2010-11-01 00:00:00

  • Controlled delivery of Gd-containing liposomes to lymph nodes: surface modification may enhance MRI contrast properties.

    abstract::Surface modification of liposomes containing Gd-diethylenetriaminepentaacetyl-phosphatidylethanolamine (Gd-DTPA-PE) as an amphiphilic paramagnetic label influences their contrast properties as MRI agents. Liposomes with the mean diameter ca. 220 nm and 10% mol content of Gd-DTPA-PE were modified with dextran (molecula...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)00083-f

    authors: Trubetskoy VS,Cannillo JA,Milshtein A,Wolf GL,Torchilin VP

    更新日期:1995-01-01 00:00:00

  • Comparison of different methods for combining phase-contrast images obtained with multiple coils.

    abstract::The ability to determine coil sensitivities implies that a method optimized in terms of maximized signal-to-noise ratio (SNR) can be applied to the combination of multiple coil images. An optimization of SNR subsequently results in a minimized variance in quantitative velocity measurements using phase-contrast imaging...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.06.002

    authors: Thunberg P,Karlsson M,Wigström L

    更新日期:2005-09-01 00:00:00

  • Glutamate quantification by PRESS or MEGA-PRESS: Validation, repeatability, and concordance.

    abstract:PURPOSE:While PRESS is often employed to measure glutamate concentrations, MEGA-PRESS enables simultaneous Glx (glutamate and glutamine) and GABA measurements. This study aimed to compare validation, repeatability, and concordance of different approaches for glutamate quantification at 3T to aid future studies in their...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.12.029

    authors: van Veenendaal TM,Backes WH,van Bussel FCG,Edden RAE,Puts NAJ,Aldenkamp AP,Jansen JFA

    更新日期:2018-05-01 00:00:00

  • A novel in silico platform for a fully automatic personalized brain tumor growth.

    abstract::Glioblastoma Multiforme is the most common and most aggressive type of brain tumors. Although accurate prediction of Glioblastoma borders and shape is absolutely essential for neurosurgeons, there are not many in silico platforms that can make such predictions. In the current study, an automatic patient-specific simul...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.12.012

    authors: Hajishamsaei M,Pishevar A,Bavi O,Soltani M

    更新日期:2020-05-01 00:00:00

  • 1H-MRS of the macaque monkey primary visual cortex at 7 T: strategies and pitfalls of shimming at the brain surface.

    abstract::Magnetic resonance spectroscopy (MRS) is ideally suited for physiology-neurochemistry experiments with the living brain and particularly for studies on the primary visual cortex (striate cortex or area V1). Yet, the highly convoluted form of the human V1 has thus far prevented the performance of MRS investigations tha...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.008

    authors: Juchem C,Logothetis NK,Pfeuffer J

    更新日期:2007-07-01 00:00:00

  • Magnetic resonance cholangiopancreatography: comparison between respiratory-triggered turbo spin echo and breath hold single-shot turbo spin echo sequences.

    abstract::The purpose of this study was to compare the relative conspicuity of the pancreaticobiliary tree on respiratory-triggered three-dimensional turbo spin echo (3D TSE RT) and breath hold single-shot turbo spin echo (SSTSE BH) acquisitions respectively in MRCP imaging. Both techniques were applied to 61 patients with clin...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00074-0

    authors: Papanikolaou N,Karantanas AH,Heracleous E,Costa JC,Gourtsoyiannis N

    更新日期:1999-11-01 00:00:00

  • Superparamagnetic iron oxide particles and positive enhancement for myocardial perfusion studies assessed by subsecond T1-weighted MRI.

    abstract::Superparamagnetic iron oxide particles (SPIOs) are usually referred to as T2 MR contrast agents, reducing signal intensity (SI) on T2-weighted MR images (negative enhancement). This study reports the original use of SPIOs as T1-enhancing contrast agents, primarily assessed in vitro, and then applied to an in vivo inve...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90241-5

    authors: Canet E,Revel D,Forrat R,Baldy-Porcher C,de Lorgeril M,Sebbag L,Vallee JP,Didier D,Amiel M

    更新日期:1993-01-01 00:00:00

  • Synovial sarcoma: MR imaging.

    abstract::Ten patients with biopsy-proved synovial sarcoma were evaluated by magnetic resonance (MR) imaging on a 1.5-T unit. The lesions showed intermediate signal intensity on T1-weighted images and heterogeneous high signal intensity on T2-weighted images. Tumors were well-demarcated from normal tissues. Additional informati...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90706-6

    authors: Mahajan H,Lorigan JG,Shirkhoda A

    更新日期:1989-03-01 00:00:00

  • Strategies for reducing large fMRI data sets for independent component analysis.

    abstract::In independent component analysis (ICA), principal component analysis (PCA) is generally used to reduce the raw data to a few principal components (PCs) through eigenvector decomposition (EVD) on the data covariance matrix. Although this works for spatial ICA (sICA) on moderately sized fMRI data, it is intractable for...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.013

    authors: Wang Z,Wang J,Calhoun V,Rao H,Detre JA,Childress AR

    更新日期:2006-06-01 00:00:00

  • Initial clinical evaluation of gadolinium DTPA for contrast-enhanced magnetic resonance imaging.

    abstract::Gadolinium DTPA was evaluated as an intravenous contrast agent for magnetic resonance imaging in 15 patients with primary or secondary intracranial neoplastic disease. T1 and T2 weighted images were obtained prior to contrast administration. T1 weighted spin echo 35/800 (TE/TR) images were utilized to detect enhanceme...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90006-2

    authors: Runge VM,Schoerner W,Niendorf HP,Laniado M,Koehler D,Claussen C,Felix R,James AE Jr

    更新日期:1985-01-01 00:00:00

  • Evidence for left-right asymmetries in the proton MRS of brain in normal volunteers.

    abstract::Although there is ample evidence in the literature for structural, functional and physiological asymmetries in the two hemispheres of human brain, direct evidence of a similar asymmetry in the in vivo distribution of brain metabolites has been lacking. In this study, the existence of chemical asymmetries in six differ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00342-6

    authors: Jayasundar R,Raghunathan P

    更新日期:1997-01-01 00:00:00

  • A simulation-based comparison of two methods for determining relaxation rates from relaxometry images.

    abstract::When assessing liver iron content using relaxometry, an average relaxation rate (R1, R2 or R2*) is usually determined from a region of interest or the entire liver. This is commonly performed by fitting the signal decay in individual voxels to an appropriate relaxation function. The voxel-level parameters resulting fr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.11.005

    authors: Marro K,Otto R,Kolokythas O,Shimamura A,Sanders JE,McDonald GB,Friedman SD

    更新日期:2011-05-01 00:00:00

  • Quantitative magnetic resonance imaging of 'Fuyu' persimmon fruit during development and ripening.

    abstract::Qualitative and quantitative proton magnetic resonance imaging techniques were applied to persimmon (Diospyros kaki cv 'Fuyu') fruit during development and post-harvest ripening. Spin-lattice (T(1)) relaxation times in mesocarp parenchyma and vascular tissue exhibited a sigmoidal pattern of increase leading to commerc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00082-1

    authors: Clark CJ,MacFall JS

    更新日期:2003-07-01 00:00:00

  • NMR study of the diffusion processes in gels.

    abstract::Stimulated spin-echo and Carr-Purcell pulse sequences, with pulsed magnetic field gradients, have been used to study the self-diffusion processes of the water in swollen and in supercoiled polyacrylamide gels and in polysaccharides agarose gels, for different polymer concentrations. Restricted diffusion effects are ev...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00202-0

    authors: Pavesi L,Balzarini M

    更新日期:1996-01-01 00:00:00

  • Diagnosis of suspicious breast lesions using an empirical mathematical model for dynamic contrast-enhanced MRI.

    abstract::The purpose of this study was to test whether an empirical mathematical model (EMM) of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can distinguish between benign and malignant breast lesions. A modified clinical protocol was used to improve the sampling of contrast medium uptake and washout. T(1)-we...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.10.011

    authors: Fan X,Medved M,Karczmar GS,Yang C,Foxley S,Arkani S,Recant W,Zamora MA,Abe H,Newstead GM

    更新日期:2007-06-01 00:00:00

  • Non-enhanced magnetic resonance imaging of the small bowel at 7 Tesla in comparison to 1.5 Tesla: First steps towards clinical application.

    abstract:OBJECTIVE:To perform non-enhanced (NE) magnetic resonance imaging (MRI) of the small bowel at 7 Tesla (7T) and to compare it with 1.5 Tesla (1.5T). MATERIAL AND METHODS:Twelve healthy subjects were prospectively examined using a 1.5T and 7T MRI system. Coronal and axial true fast imaging with steady-state precession (...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.11.012

    authors: Hahnemann ML,Kraff O,Maderwald S,Johst S,Orzada S,Umutlu L,Ladd ME,Quick HH,Lauenstein TC

    更新日期:2016-06-01 00:00:00

  • A computer algorithm for the simulation of any nuclear magnetic resonance (NMR) imaging method.

    abstract::More than a dozen Nuclear Magnetic Resonance (NMR) imaging methods have been described using different radio-frequency pulse sequences, magnetic field gradient variations, and data processing. In order to have a theoretical understanding in the most general case, we have conceived a computer program for the simulation...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(84)90065-1

    authors: Bittoun J,Taquin J,Sauzade M

    更新日期:1984-01-01 00:00:00

  • Quality assessment of localization technique performance in small volume in vivo 1H MR spectroscopy.

    abstract::A new phantom and evaluation method for experimental evaluation of 1H-magnetic resonance spectroscopy single volume localization techniques regarding signal contamination (C), defined as the part of the signal originating outside the volume of interest, is presented. The quality assessment method is based on a spheric...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00076-4

    authors: Burtscher IM,Johansson E,Holtås S,Ståhlberg F

    更新日期:1999-12-01 00:00:00

  • Magnetic resonance spectroscopy of the brain in neurologically asymptomatic HIV-infected patients.

    abstract::The CNS involvement is frequently found in human immunodeficiency virus (HIV) infection. The purpose of our study was to determine whether proton magnetic resonance spectroscopy (MRS) could detect early brain involvement in neurologically asymptomatic HIV-infected patients with normal MR imagings and to find the corre...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0730-725x(00)00173-9

    authors: Suwanwelaa N,Phanuphak P,Phanthumchinda K,Suwanwela NC,Tantivatana J,Ruxrungtham K,Suttipan J,Wangsuphachart S,Hanvanich M

    更新日期:2000-09-01 00:00:00

  • Ultrashort echo (UTE) versus pointwise encoding time reduction with radial acquisition (PETRA) sequences at 3 Tesla for knee meniscus: A comparative study.

    abstract:PURPOSE:The purposes of this study were to (1) correlate the ultrashort echo time (TE) signal intensity of the pointwise encoding time reduction with radial acquisition (PETRA) sequence with that of the ultrashort echo (UTE) sequence using in vivo meniscal ultrashort TE imaging of the knee with a 3-Tesla (3T) clinical ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.09.003

    authors: Lee YH,Suh JS,Grodzki D

    更新日期:2016-02-01 00:00:00

  • High-resolution, three-dimensional diffusion-weighted breast imaging using DESS.

    abstract:PURPOSE:To evaluate the use of the double-echo steady-state (DESS) sequence for acquiring high-resolution breast images with diffusion and T2 weighting. MATERIALS AND METHODS:Phantom scans were used to verify the T2 and diffusion weighting of the DESS sequence. Image distortion was evaluated in volunteers by comparing...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.12.014

    authors: Granlund KL,Staroswiecki E,Alley MT,Daniel BL,Hargreaves BA

    更新日期:2014-05-01 00:00:00

  • MR visible localization device for radiographic-pathologic correlation of surgical specimens.

    abstract:PURPOSE:The detection of small parenchymal hepatic lesions identified by preoperative imaging remains a challenge for traditional pathologic methods in large specimens. We developed a magnetic resonance imaging (MRI) compatible localization device for imaging of surgical specimens aimed to improve identification and lo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.11.021

    authors: Kinner S,Schubert TB,Nocerino EA,Hynes S,Colgan TJ,Loeffler AG,Brace C,Reeder SB,Winslow E

    更新日期:2017-04-01 00:00:00

  • Fast multi-contrast MRI reconstruction.

    abstract::Multi-contrast magnetic resonance imaging (MRI) is a useful technique to aid clinical diagnosis. This paper proposes an efficient algorithm to jointly reconstruct multiple T1/T2-weighted images of the same anatomical cross section from partially sampled k-space data. The joint reconstruction problem is formulated as m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.025

    authors: Huang J,Chen C,Axel L

    更新日期:2014-12-01 00:00:00

  • Low-frequency signal changes reflect differences in functional connectivity between good readers and dyslexics during continuous phoneme mapping.

    abstract::The current fMRI study investigated correlations of low-frequency signal changes in the left inferior frontal gyrus, right inferior frontal gyrus and cerebellum in 13 adult dyslexic and 10 normal readers to examine functional networks associated with these regions. The extent of these networks to regions associated wi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.006

    authors: Stanberry LI,Richards TL,Berninger VW,Nandy RR,Aylward EH,Maravilla KR,Stock PS,Cordes D

    更新日期:2006-04-01 00:00:00

  • Early assessment of breast cancer response to neoadjuvant chemotherapy by semi-quantitative analysis of high-temporal resolution DCE-MRI: preliminary results.

    abstract:PURPOSE:To evaluate whether semi-quantitative analysis of high temporal resolution dynamic contrast-enhanced MRI (DCE-MRI) acquired early in treatment can predict the response of locally advanced breast cancer (LABC) to neoadjuvant chemotherapy (NAC). MATERIALS AND METHODS:As part of an IRB-approved prospective study,...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.mri.2013.07.002

    authors: Abramson RG,Li X,Hoyt TL,Su PF,Arlinghaus LR,Wilson KJ,Abramson VG,Chakravarthy AB,Yankeelov TE

    更新日期:2013-11-01 00:00:00

  • Non-contrast-enhanced MR angiography in the diagnosis of Budd-Chiari syndrome (BCS) compared with digital subtraction angiography (DSA): Preliminary results.

    abstract::Non-CE MRA techniques (true steady-state free-precession, SSFP) have been used effectively for the selective visualization of the portal venous system and inferior vena cava. Budd-Chiari Syndrome (BCS) encompasses a number of conditions that cause the obstruction of the hepatic outflow tract from the small hepatic vei...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.006

    authors: Yang C,Li C,Zeng M,Lu X,Li J,Wang J,Sami MU,Xu K

    更新日期:2017-02-01 00:00:00