T1 and T2* mapping of the human quadriceps and patellar tendons using ultra-short echo-time (UTE) imaging and bivariate relaxation parameter-based volumetric visualization.

Abstract:

:Quantification of magnetic resonance (MR)-based relaxation parameters of tendons and ligaments is challenging due to their very short transverse relaxation times, requiring application of ultra-short echo-time (UTE) imaging sequences. We quantify both T1 and T2* in the quadriceps and patellar tendons of healthy volunteers at a field strength of 3 T and visualize the results based on 3D segmentation by using bivariate histogram analysis. We applied a 3D ultra-short echo-time imaging sequence with either variable repetition times (VTR) or variable flip angles (VFA) for T1 quantification in combination with multi-echo acquisition for extracting T2*. The values of both relaxation parameters were subsequently binned for bivariate histogram analysis and corresponding cluster identification, which were subsequently visualized. Based on manually-drawn regions of interest in the tendons on the relaxation parameter maps, T1 and T2* boundaries were selected in the bivariate histogram to segment the quadriceps and patellar tendons and visualize the relaxation times by 3D volumetric rendering. Segmentation of bone marrow, fat, muscle and tendons was successfully performed based on the bivariate histogram analysis. Based on the segmentation results mean T2* relaxation times, over the entire tendon volumes averaged over all subjects, were 1.8 ms ± 0.1 ms and 1.4 ms ± 0.2 ms for the patellar and quadriceps tendons, respectively. The mean T1 value of the patellar tendon, averaged over all subjects, was 527 ms ± 42 ms and 476 ms ± 40 ms for the VFA and VTR acquisitions, respectively. The quadriceps tendon had higher mean T1 values of 662 ms ± 97 ms (VFA method) and 637 ms ± 40 ms (VTR method) compared to the patellar tendon. 3D volumetric visualization of the relaxation times revealed that T1 values are not constant over the volume of both tendons, but vary locally. This work provided additional data to build upon the scarce literature available on relaxation times in the quadriceps and patellar tendons. We were able to segment both tendons and to visualize the relaxation parameter distributions over the entire tendon volumes.

journal_name

Magn Reson Imaging

authors

Krämer M,Maggioni MB,Brisson NM,Zachow S,Teichgräber U,Duda GN,Reichenbach JR

doi

10.1016/j.mri.2019.07.015

subject

Has Abstract

pub_date

2019-11-01 00:00:00

pages

29-36

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(19)30232-2

journal_volume

63

pub_type

杂志文章
  • Lesion load measurements in multiple sclerosis: the effect of incorporating magnetization transfer contrast in fast-FLAIR sequence.

    abstract::We compared the ability and reproducibility of a fast fluid-attenuated inversion recovery (fast-FLAIR) sequence with and without a magnetization transfer (MT) pulse for detecting and measuring multiple sclerosis (MS)-related abnormalities on magnetic resonance imaging (MRI) scans from 20 patients. The Contrast-to-Nois...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00182-9

    authors: Filippi M,Rocca MA,Mastronardo G,Comi G

    更新日期:1999-04-01 00:00:00

  • Perfusion and diffusion in meningioma tumors: a preliminary multiparametric analysis with Dynamic Susceptibility Contrast and IntraVoxel Incoherent Motion MRI.

    abstract::Multiparametric MRI is a remarkable imaging method for the assessment of patho-physiological processes. In particular, brain tumor characterization has taken advantage of the development of advanced techniques such as Diffusion- (DWI) and Perfusion- (PWI) Weighted Imaging, but a thorough analysis of meningiomas is sti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.12.003

    authors: Zampini MA,Buizza G,Paganelli C,Fontana G,D'Ippolito E,Valvo F,Preda L,Baroni G

    更新日期:2020-04-01 00:00:00

  • Comparison of dynamic contrast-enhanced magnetic resonance imaging and contrast-enhanced ultrasound for evaluation of the effects of sorafenib in a rat model of hepatocellular carcinoma.

    abstract:OBJECTIVES:To compare the accuracy of contrast-enhanced ultrasound (CEUS) and Dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) for the assessment of changes in tissue vascularization as result of sorafenib treatment in a rat model of hepatocellular carcinoma (HCC). METHODS:Male Buffalo rats with orthot...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.11.012

    authors: Muñoz NM,Minhaj AA,Maldonado KL,Kingsley CV,Cortes AC,Taghavi H,Polak U,Mitchell JM,Ensor JE,Bankson JA,Rashid A,Avritscher R

    更新日期:2019-04-01 00:00:00

  • Off-resonance frequency filtered magnetic resonance imaging.

    abstract::One of the main problems with rapid magnetic resonance imaging (MRI) techniques is the artifacts that result from off-resonance effects. The proposed off-resonance frequency filtered MRI (OFF-MRI) method focuses on the elimination of off-resonance components from the image of the observed object. To maintain imaging s...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.12.027

    authors: Medic J,Tomazic S

    更新日期:2010-05-01 00:00:00

  • Dixon-based fat-free MR-angiography compared to first pass and steady-state high-resolution MR-angiography using a blood pool contrast agent.

    abstract:INTRODUCTION:Compared to standard arterial-only first-pass MR-angiography (FPMRA), imaging during the equilibrium phase of a blood pool contrast agent (steady state) has been shown to provide higher image quality and better stenosis grading. Homogenous Dixon fat-suppression promises to increase contrast by suppression ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.07.005

    authors: Homsi R,Gieseke J,Kukuk GM,Träber F,Willinek WA,Schild HH,Hadizadeh DR

    更新日期:2015-11-01 00:00:00

  • Quantitative susceptibility mapping of prostate with separate calculations for water and fat regions for reducing shading artifacts.

    abstract::We propose a novel processing method for reducing shading artifacts in quantitative susceptibility mapping (QSM) for prostate imaging. In the conventional method, calculation errors in the boundary regions between water and fat cause shading artifacts that degrade the image quality for QSM. In the proposed method, wat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.11.006

    authors: Sato R,Shirai T,Soutome Y,Bito Y,Ochi H

    更新日期:2020-02-01 00:00:00

  • Application of magnetic resonance imaging to the measurement of neurodegeneration in rat brain: MRI data correlate strongly with histology and enzymatic analysis.

    abstract::Focal brain ischemia was induced by middle cerebral artery occlusion in the rat. The volume of cerebral damage was determined 2 days later by MRI in vivo and in the same animals histologically. The edema volume as measured by MRI and the histologically determined infarction was highly correlated. As a consequence, the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90411-r

    authors: Allegrini PR,Sauer D

    更新日期:1992-01-01 00:00:00

  • Fast multi-contrast MRI reconstruction.

    abstract::Multi-contrast magnetic resonance imaging (MRI) is a useful technique to aid clinical diagnosis. This paper proposes an efficient algorithm to jointly reconstruct multiple T1/T2-weighted images of the same anatomical cross section from partially sampled k-space data. The joint reconstruction problem is formulated as m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.025

    authors: Huang J,Chen C,Axel L

    更新日期:2014-12-01 00:00:00

  • Strategies for reducing large fMRI data sets for independent component analysis.

    abstract::In independent component analysis (ICA), principal component analysis (PCA) is generally used to reduce the raw data to a few principal components (PCs) through eigenvector decomposition (EVD) on the data covariance matrix. Although this works for spatial ICA (sICA) on moderately sized fMRI data, it is intractable for...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.013

    authors: Wang Z,Wang J,Calhoun V,Rao H,Detre JA,Childress AR

    更新日期:2006-06-01 00:00:00

  • Microstructure abnormity in the optic nerve of type 1 diabetic rats revealed by diffusion tensor imaging study.

    abstract::Diabetic retinopathy (DR) is one of a major complication of type 1 diabetes mellitus (T1DM) and a leading cause of blindness. Evidence of animal study has shown that it is not only a microvasucular lesion of the eye, but also a neurodegeneration disease of the visual system. However, the in vivo imaging evidence of ax...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.05.003

    authors: Gao L,Huang M,Luo X,Song T,Wang X,Wang Z,Zhang W,Chen J,Lei H

    更新日期:2020-09-01 00:00:00

  • T2* measurements in human brain at 1.5, 3 and 7 T.

    abstract::Measurements have been carried out in six subjects at magnetic fields of 1.5, 3 and 7 T, with the aim of characterizing the variation of T2* with field strength in human brain. Accurate measurement of T2* in the presence of macroscopic magnetic field inhomogeneity is problematic due to signal decay resulting from thro...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.02.014

    authors: Peters AM,Brookes MJ,Hoogenraad FG,Gowland PA,Francis ST,Morris PG,Bowtell R

    更新日期:2007-07-01 00:00:00

  • Neural activity-induced modulation of BOLD poststimulus undershoot independent of the positive signal.

    abstract::Despite intense research on the blood oxygenation level-dependent (BOLD) signal underlying functional magnetic resonance imaging, our understanding of its physiological basis is far from complete. In this study, it was investigated whether the so-called poststimulus BOLD signal undershoot is solely a passive vascular ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.04.003

    authors: Sadaghiani S,Uğurbil K,Uludağ K

    更新日期:2009-10-01 00:00:00

  • The diagnosis of hippocampal sclerosis: other techniques.

    abstract::Pathologically, hippocampal sclerosis (HS) is characterized by neuronal loss and gliosis affecting particularly the pyramidal neurons of CA1, CA3, and CA4 with relative sparing of the CA2 neurons. This can be identified in vivo with magnetic resonance (MR) imaging techniques that can reveal both morphological and sign...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(95)02016-m

    authors: Jackson GD

    更新日期:1995-01-01 00:00:00

  • A case of Budd-Chiari syndrome: Gd-EOB-DTPA-enhanced MR findings.

    abstract::Budd-Chiari syndrome (BCS) is a rare disorder caused by the obstruction of hepatic venous outflow, leading to sinusoidal congestion, ischemic injury to liver cells and portal hypertension. Long-term survival largely depends on whether hepatocellular carcinoma occurs. A recently available liver-specific contrast medium...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.10.013

    authors: Kitajima K,Yoshikawa T,Seo Y,Ohno Y,Yano Y,Miki A,Kanda T,Kanata N,Azuma T,Sugimura K

    更新日期:2011-05-01 00:00:00

  • Functional magnetic resonance imaging in a stereotactic setup.

    abstract::The localization of critical structures within the brain is important for the planning of therapeutic strategies. Functional MRI is capable to assess functional response of cortical structures to certain stimuli. The authors present two techniques for functional MRI (fMRI) in a stereotactic set-up. The skull of the pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)02108-x

    authors: Debus J,Essig M,Schad LR,Wenz F,Baudendistel K,Knopp MV,Engenhart R,Lorenz WJ

    更新日期:1996-01-01 00:00:00

  • A computer algorithm for the simulation of any nuclear magnetic resonance (NMR) imaging method.

    abstract::More than a dozen Nuclear Magnetic Resonance (NMR) imaging methods have been described using different radio-frequency pulse sequences, magnetic field gradient variations, and data processing. In order to have a theoretical understanding in the most general case, we have conceived a computer program for the simulation...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(84)90065-1

    authors: Bittoun J,Taquin J,Sauzade M

    更新日期:1984-01-01 00:00:00

  • 23Na magnetic resonance imaging: distribution of brine in muscle.

    abstract::Magnetic resonance imaging (MRI) has been used to characterize tissues in morphological studies. Here, 23Na NMR imaging was used to study the distribution in muscle of brine (5 M NaCl), injected before onset of rigor mortis. First, the distribution of brine was monitored in excised muscle from rabbits for 6 hr followi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92360-4

    authors: Renou JP,Benderbous S,Bielicki G,Foucat L,Donnat JP

    更新日期:1994-01-01 00:00:00

  • Lee-Goldburg solid-state imaging.

    abstract::A new approach to solid-state imaging (SSI) is presented. The method relies on narrowing the resonance line using the Lee-Goldburg sequence. The technique is easy to implement in practice and may find widespread applications in materials science. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90409-s

    authors: De Luca F,Lugeri N,De Simone BC,Maraviglia B

    更新日期:1992-01-01 00:00:00

  • Quantitative MRI using T1ρ and T2 in human osteoarthritic cartilage specimens: correlation with biochemical measurements and histology.

    abstract:PURPOSE:A direct correlation between T(1ρ), T(2) and quantified proteoglycan and collagen contents in human osteoarthritic cartilage has yet to be documented. We aimed to investigate the orientation effect on T(1ρ) and T(2) values in human osteoarthritic cartilage and to quantify the correlation between T(1ρ), T(2) vs....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.09.004

    authors: Li X,Cheng J,Lin K,Saadat E,Bolbos RI,Jobke B,Ries MD,Horvai A,Link TM,Majumdar S

    更新日期:2011-04-01 00:00:00

  • Fat ViP MRI: Virtual Phantom Magnetic Resonance Imaging of water-fat systems.

    abstract:OBJECT:Virtual Phantom Magnetic Resonance Imaging (ViP MRI) is a method to generate reference signals on MR images, using external radiofrequency (RF) signals. The aim of this study was to assess the feasibility of ViP MRI to generate complex-data images of phantoms mimicking water-fat systems. MATERIALS AND METHODS:V...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.002

    authors: Salvati R,Hitti E,Bellanger JJ,Saint-Jalmes H,Gambarota G

    更新日期:2016-06-01 00:00:00

  • A spectroscopic NMR investigation of the calcium silicate hydrates present in cement and concrete.

    abstract::NMR spectroscopy is applied to study microstructure of calcium silicate hydrates present in cement and concrete. It is shown that 29Si NMR gives information on the siliceous skeleton of the hydrates. 1H NMR, using CRAMPS techniques, allows to discriminate between protons linked to silicon atoms or to calcium atoms. A ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00211-1

    authors: Zanni H,Rassem-Bertolo R,Masse S,Fernandez L,Nieto P,Bresson B

    更新日期:1996-01-01 00:00:00

  • Identification and characterization of biological tissues by NMR. Concerted research project of the European Economic Community. Introduction, objectives, and activities.

    abstract::NMR offers, in the complex proton relaxation properties of biological tissues, a unique and potentially powerful tool of tissue characterization. The difficulties encountered so far in comparing the results of in vitro and in vivo NMR studies carried out in different laboratories inhibit NMR methodologies from fully e...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90447-x

    authors: Podo F,Orr JS,Schmidt KH,Bovée WM

    更新日期:1988-03-01 00:00:00

  • In vivo temporal EPR imaging of the brain of rats by using two types of blood-brain barrier-permeable nitroxide radicals.

    abstract::In vivo temporal EPR imaging was conducted on the brain of rats that received one of two kinds of blood-brain barrier-permeable nitroxide radicals via the tail vein-one is a water-soluble 3-hydroxymethyl-2,2,5,5-tetramethylpyrrolidine-1-oxyl (hydroxymethyl-PROXYL); and the other is a non-water-soluble 3-methoxycarbony...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00491-5

    authors: Yokoyama H,Itoh O,Aoyama M,Obara H,Ohya H,Kamada H

    更新日期:2002-04-01 00:00:00

  • Drug monitoring of 5-fluorouracil: in vivo 19F NMR study during 5-FU chemotherapy in patients with metastases of colorectal adenocarcinoma.

    abstract::The metabolism of 5-fluorouracil (5-FU) is complex and the reason for the low response rate of tumor patients to 5-FU is currently unknown. The aim of this study was to evaluate whether spectral parameters obtained noninvasively by in vivo 19F nuclear magnetic resonance (NMR) spectroscopy can be used to assess individ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92544-5

    authors: Schlemmer HP,Bachert P,Semmler W,Hohenberger P,Schlag P,Lorenz WJ,van Kaick G

    更新日期:1994-01-01 00:00:00

  • Off-resonance correction using an estimated linear time map.

    abstract::Images acquired in the presence of magnetic field deviations and reconstructed without taking into account the off-resonance, are distorted and corrupted with artifacts. Several post-processing algorithms have been developed for correcting the distortion when it is not possible to fix the field inhomogeneities. These ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00487-3

    authors: Akel JA,Rosenblitt M,Irarrazaval P

    更新日期:2002-02-01 00:00:00

  • Investigating mobility of crude oil adsorbates on mineral surfaces by NMR.

    abstract::We have applied diffusion and relaxation Nuclear Magnetic Resonance experiments to investigate the translational and rotational mobility of adsorbents on quartz and calcite mineral surfaces. On both surfaces it was found that water is the dominant molecule. On the quartz surface the majority of water molecules have a ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.10.002

    authors: Sørgård HN,Totland C,Nerdal W,Seland JG

    更新日期:2019-02-01 00:00:00

  • Optimal real-time estimation in diffusion tensor imaging.

    abstract::Diffusion tensor imaging (DTI) constitutes the most used paradigm among the diffusion-weighted magnetic resonance imaging (DW-MRI) techniques due to its simplicity and application potential. Recently, real-time estimation in DW-MRI has deserved special attention, with several proposals aiming at the estimation of mean...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.12.001

    authors: Casaseca-de-la-Higuera P,Tristán-Vega A,Aja-Fernández S,Alberola-López C,Westin CF,San José Estépar R

    更新日期:2012-05-01 00:00:00

  • Magnetic resonance cholangiopancreatography: comparison between respiratory-triggered turbo spin echo and breath hold single-shot turbo spin echo sequences.

    abstract::The purpose of this study was to compare the relative conspicuity of the pancreaticobiliary tree on respiratory-triggered three-dimensional turbo spin echo (3D TSE RT) and breath hold single-shot turbo spin echo (SSTSE BH) acquisitions respectively in MRCP imaging. Both techniques were applied to 61 patients with clin...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00074-0

    authors: Papanikolaou N,Karantanas AH,Heracleous E,Costa JC,Gourtsoyiannis N

    更新日期:1999-11-01 00:00:00

  • Evaluation of intracranial stenoses and aneurysms with accelerated 4D flow.

    abstract::The aim of this study was to evaluate intracranial arterial stenoses and aneurysms with accelerated time-resolved three-dimensional (3D) phase-contrast MRI or 4D flow. The 4D flow technique was utilized to image four normal volunteers, two patients with intracranial stenoses and two patients with intracranial aneurysm...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.042

    authors: Hope TA,Hope MD,Purcell DD,von Morze C,Vigneron DB,Alley MT,Dillon WP

    更新日期:2010-01-01 00:00:00

  • Characterisation of wetting heterogeneities in sandstone rocks by MRI.

    abstract::MRI is applied to the visualisation of wetting heterogeneities evidenced by water proton T1 contrast at 0.1 T. Water saturated Fontainebleau sandstone samples were examined either in their original water-wet condition, or after silanation. T1, T2Hahn, and T2CPMG were measured for several porosities. T1 and T2CPMG of h...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91557-1

    authors: Guillot G,Chardaire-Rivière C,Bobroff S,Le Roux A,Roussel JC,Cuiec L

    更新日期:1994-01-01 00:00:00