In vivo temporal EPR imaging of the brain of rats by using two types of blood-brain barrier-permeable nitroxide radicals.

Abstract:

:In vivo temporal EPR imaging was conducted on the brain of rats that received one of two kinds of blood-brain barrier-permeable nitroxide radicals via the tail vein-one is a water-soluble 3-hydroxymethyl-2,2,5,5-tetramethylpyrrolidine-1-oxyl (hydroxymethyl-PROXYL); and the other is a non-water-soluble 3-methoxycarbonyl-2,2,5,5-tetramethylpyrrolidine-1-oxyl (PCAM). From temporal EPR imaging data, temporal changes in the distribution of the nitroxide radical in the cerebral cortex, striatum, and hippocampus in the brain were investigated. It was found that the half-lives of the three parts in the brain of hydroxymethyl-PROXYL are longer and their EPR signal intensities are greater than those of PCAM.

journal_name

Magn Reson Imaging

authors

Yokoyama H,Itoh O,Aoyama M,Obara H,Ohya H,Kamada H

doi

10.1016/s0730-725x(02)00491-5

subject

Has Abstract

pub_date

2002-04-01 00:00:00

pages

277-84

issue

3

eissn

0730-725X

issn

1873-5894

pii

S0730725X02004915

journal_volume

20

pub_type

杂志文章
  • Microstructure abnormity in the optic nerve of type 1 diabetic rats revealed by diffusion tensor imaging study.

    abstract::Diabetic retinopathy (DR) is one of a major complication of type 1 diabetes mellitus (T1DM) and a leading cause of blindness. Evidence of animal study has shown that it is not only a microvasucular lesion of the eye, but also a neurodegeneration disease of the visual system. However, the in vivo imaging evidence of ax...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.05.003

    authors: Gao L,Huang M,Luo X,Song T,Wang X,Wang Z,Zhang W,Chen J,Lei H

    更新日期:2020-09-01 00:00:00

  • Fast and high-resolution quantitative mapping of tissue water content with full brain coverage for clinically-driven studies.

    abstract::An efficient method for obtaining longitudinal relaxation time (T1) maps is based on acquiring two spoiled gradient recalled echo (SPGR) images in steady states with different flip angles, which has also been extended, with additional acquisitions, to obtain a tissue water content (M0) map. Several factors, including ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.08.001

    authors: Sabati M,Maudsley AA

    更新日期:2013-12-01 00:00:00

  • 4D MR phase and magnitude segmentations with GPU parallel computing.

    abstract::The increasing size and number of data sets of large four dimensional (three spatial, one temporal) magnetic resonance (MR) cardiac images necessitates efficient segmentation algorithms. Analysis of phase-contrast MR images yields cardiac flow information which can be manipulated to produce accurate segmentations of t...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.019

    authors: Bergen RV,Lin HY,Alexander ME,Bidinosti CP

    更新日期:2015-01-01 00:00:00

  • Cardiac magnetic resonance tissue tracking in right ventricle: Feasibility and normal values.

    abstract:PURPOSE:To investigate right ventricular (RV) strain in patients without identified cardiac pathology using cardiac magnetic resonance tissue tracking (CMR TT). METHODS:A total of 50 consecutive patients with no identified cardiac pathology were analyzed. RV longitudinal and circumferential strain was assessed by CMR ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.01.007

    authors: Truong VT,Safdar KS,Kalra DK,Gao X,Ambach S,Taylor MD,Moore R,Taylor RJ,Germann J,Toro-Salazar O,Jefferies JL,Bartone C,Raman SV,Ngo T,Mazur W

    更新日期:2017-05-01 00:00:00

  • Intensity dependence of flow signal in slice selective velocity measurements.

    abstract::The quantitative determination of flow velocities using inflow-outflow techniques require slice selective excitation pulses. The intensity-velocity relationship for such methods is shown to be such that flow velocities estimated using techniques which rely on an absolute calibration of the measured intensity are sensi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90325-1

    authors: Saloner D

    更新日期:1989-01-01 00:00:00

  • In vivo nuclear magnetic resonance imaging and spectroscopy of aquatic organisms.

    abstract::NMR imaging and localized 1H spectroscopy of a variety of aquatic organisms in vivo is described for the first time. The practical consideration of life support, water volume, salinity, and anesthesia are discussed and solutions presented. Such animal studies shape our understanding of physiology, biochemistry, and bi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90253-x

    authors: Blackband SJ,Stoskopf MK

    更新日期:1990-01-01 00:00:00

  • Characterisation of crosslinked elastomeric materials by 1H NMR relaxation time distributions.

    abstract::One of the most critical structural parameters in elastomeric materials is the density of cross-linking between the polymeric chains. This chemical feature greatly affects chain motions and is determinant in controlling mechanical properties of the final product. NMR techniques are widely and efficiently applied to in...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00257-0

    authors: Borgia GC,Fantazzini P,Ferrando A,Maddinelli G

    更新日期:2001-04-01 00:00:00

  • Biodegradable cystamine spacer facilitates the clearance of Gd(III) chelates in poly(glutamic acid) Gd-DO3A conjugates for contrast-enhanced MR imaging.

    abstract::Poly(L-glutamic acid) (PGA)-cystamine-[gadolinium (Gd)-DO3A] was prepared in high yield with a high Gd-DO3A conjugation efficiency. Approximately 55% of the carboxylic groups in PGA were loaded with Gd-DO3A via cystamine as the spacer. Cystamine can be readily cleaved by endogenous thiols to release the Gd(III) chelat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.03.009

    authors: Ke T,Feng Y,Guo J,Parker DL,Lu ZR

    更新日期:2006-09-01 00:00:00

  • Peripheral nerve diffusion tensor imaging.

    abstract::We examined if MR diffusion tensor imaging with fiber tracking could be performed on the sciatic nerve. In 3 healthy volunteers the proximal thigh was examined on a 1.5-Tesla MR-scanner with a 2-channel phased-array coil. Though inherently susceptible to motion, field inhomogeneities, and fast T(2)-relaxation of the d...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.073

    authors: Skorpil M,Karlsson M,Nordell A

    更新日期:2004-06-01 00:00:00

  • A volume resolution phantom for MRI.

    abstract::Multisite quantitative magnetic resonance imaging (qMRI) of volume requires a small isotropic point spread-function (PSF) that is spatially, temporarily, and platform invariant. A phantom which will allow rapid assessment of this metric throughout the imaged volume without repositioning will assist certification of im...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.07.002

    authors: Moon SY,Hornak JP

    更新日期:2010-02-01 00:00:00

  • NMR study of the diffusion processes in gels.

    abstract::Stimulated spin-echo and Carr-Purcell pulse sequences, with pulsed magnetic field gradients, have been used to study the self-diffusion processes of the water in swollen and in supercoiled polyacrylamide gels and in polysaccharides agarose gels, for different polymer concentrations. Restricted diffusion effects are ev...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00202-0

    authors: Pavesi L,Balzarini M

    更新日期:1996-01-01 00:00:00

  • Simultaneous acquisition of multiple orders of intermolecular multiple-quantum coherence images in vivo.

    abstract::Until recently, NMR imaging with intermolecular multiple-quantum coherences (iMQCs) has been based on the acquisition of a single echo. In vivo studies of iMQC image contrast would greatly benefit from a method that could acquire several orders of quantum coherence during the same acquisition. This would enable compar...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.10.019

    authors: Shannon KL,Branca RT,Galiana G,Cenzano S,Bouchard LS,Soboyejo W,Warren WS

    更新日期:2004-12-01 00:00:00

  • Arterial input functions (AIFs) measured directly from arteries with low and standard doses of contrast agent, and AIFs derived from reference tissues.

    abstract::Measurements of arterial input function (AIF) can have large systematic errors at standard contrast agent doses in dynamic contrast enhanced MRI (DCE-MRI). We compared measured AIFs from low dose (AIFLD) and standard dose (AIFSD) contrast agent injections, as well as the AIF derived from a muscle reference tissue and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.10.025

    authors: Wang S,Fan X,Medved M,Pineda FD,Yousuf A,Oto A,Karczmar GS

    更新日期:2016-02-01 00:00:00

  • The prospects for high resolution optical brain imaging: the magnetic resonance perspective.

    abstract::Various analogs of NMR and MRI are now technically possible in optics; specifically, high-resolution laser-pulse shaping and complex pulse sequence generation with well-defined phase shifts has been demonstrated. Here we summarize this technology and discuss the potential for these methods to enhance optical functiona...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.08.024

    authors: Warren WS,Wagner W,Ye T

    更新日期:2003-12-01 00:00:00

  • Data-driven curvilinear reconstructions of 3D MR images: application to cryptogenic extratemporal epilepsy.

    abstract::This paper presents a data-driven method for the reconstruction and visualisation of curvilinear slices from three-dimensional (3D) magnetic resonance (MR) scans of the head. Visualisation of curvilinear slices, rather than standard planar slices, produces symmetrical views of the cortex and allows small abnormalities...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00132-5

    authors: Musse O,Armspach JP,Namer IJ,Heitz F,Hennel F,Grucker D

    更新日期:1998-12-01 00:00:00

  • Monitoring of task performance during functional magnetic resonance imaging of sensorimotor cortex at 1.5 T.

    abstract::Functional magnetic resonance imaging (fMRI) has found widespread clinical interest. Difficulties in clinical use of the fMRI technique arise, considering the lack of knowledge about activation task performance. This accounts especially for sensorimotor activation studies, in which performance of the sensorimotor acti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02052-u

    authors: Baudendistel K,Schad LR,Wenz F,Essig M,Schröder J,Jahn T,Knopp MV,Lorenz WJ

    更新日期:1996-01-01 00:00:00

  • Perfusion MR imaging and proton MR spectroscopic imaging in differentiating necrotizing cerebritis from glioblastoma multiforme.

    abstract::We describe a lesion with the magnetic resonance imaging (MRI) characteristics of a glioblastoma mutiforme and demonstrate how perfusion MRI and proton MR spectroscopic imaging can be used to differentiate necrotizing cerebritis from what appeared to be a high-grade glioma. A 43-year-old woman presented to her physici...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.09.028

    authors: Pivawer G,Law M,Zagzag D

    更新日期:2007-02-01 00:00:00

  • Simultaneous PET-MRI in oncology: a solution looking for a problem?

    abstract::With the recent development of integrated positron emission tomography-magnetic resonance imaging (PET-MRI) scanners, new possibilities for quantitative molecular imaging of cancer are realized. However, the practical advantages and potential clinical benefits of the ability to record PET and MRI data simultaneously m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2012.06.001

    authors: Yankeelov TE,Peterson TE,Abramson RG,Izquierdo-Garcia D,Arlinghaus LR,Li X,Atuegwu NC,Catana C,Manning HC,Fayad ZA,Gore JC

    更新日期:2012-11-01 00:00:00

  • Characterization of light hydrocarbon reservoirs by gradient-NMR well logging.

    abstract::New methods for acquiring and processing gradient NMR well log data enable signals from gas, light oil, and water to be unambiguously separated and, in many cases, quantified. These methods exploit the combined effects of T1-based and diffusion-based contrast on log response. T1 contrast, which separates the water and...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00162-2

    authors: Mardon D,Prammer MG,Coates GR

    更新日期:1996-01-01 00:00:00

  • Using nine degrees-of-freedom registration to correct for changes in voxel size in serial MRI studies.

    abstract::Quantitative longitudinal brain magnetic resonance (MR) studies may be confounded by scanner-related drifts in voxel sizes. Total intracranial volume (TIV) normalisation is commonly used to correct serial cerebral volumetric measurements for these drifts. We hypothesised that automated rigid-body registration of whole...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.057

    authors: Whitwell JL,Schott JM,Lewis EB,MacManus DG,Fox NC

    更新日期:2004-09-01 00:00:00

  • Evaluation of pancreatic exocrine insufficiency by cine-dynamic MRCP using spatially selective inversion-recovery (IR) pulse: Correlation with severity of chronic pancreatitis based on morphological changes of pancreatic duct.

    abstract:PURPOSE:To evaluate the correlation between the pancreatic exocrine insufficiency estimated by cine-dynamic MRCP using spatially selective IR pulse and the severity stages (modified Cambridge classification) based on morphological changes of the pancreatic duct in patients with suspected chronic pancreatitis. MATERIAL...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.12.007

    authors: Yasokawa K,Ito K,Kanki A,Yamamoto A,Torigoe T,Sato T,Tamada T

    更新日期:2018-05-01 00:00:00

  • In situ magnetic resonance measurement of conversion, hydrodynamics and mass transfer during single- and two-phase flow in fixed-bed reactors.

    abstract::In recent years there has been increasing interest in applying magnetic resonance (MR) techniques in areas of engineering and chemical technology. The science that underpins many of these applications is the physics and chemistry of transport and reaction processes in porous materials. Key to the exploitation of MR me...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00127-9

    authors: Gladden LF,Alexander P,Britton MM,Mantle MD,Sederman AJ,Yuen EH

    更新日期:2003-04-01 00:00:00

  • The comparison of the performance of 3 T and 7 T T2 mapping for untreated low-grade cartilage lesions.

    abstract:OBJECTIVE:To investigate T2 mapping as a possible marker for low-grade human articular cartilage lesions during a one-year follow-up, possible changes during the follow-up and compare the reliability and sensitivity of these measurements on high-field (3 T) and ultra-high-field (7 T) MRI scanners. DESIGN:Twenty-one pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.09.021

    authors: Juras V,Schreiner M,Laurent D,Zbýň Š,Mlynarik V,Szomolanyi P,Hager B,Scotti C,Goldhahn J,Heule R,Bieri O,Trattnig S

    更新日期:2019-01-01 00:00:00

  • In vitro adrenal cortex lesions characterization by NMR spectroscopy.

    abstract::Percentage of lipid content of 22 adrenal cortex lesions and their water proton longitudinal relaxation time were measured in vitro at 60 MHz. Although water relaxation times obtained on benign and malignant samples overlap each other, measurements of the percentage of lipids performed on the same tissues allow us to ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90123-8

    authors: Leroy-Willig A,Roucayrol JC,Luton JP,Courtieu J,Niesenbaum N,Louvel A

    更新日期:1987-01-01 00:00:00

  • High-resolution in vivo diffusion tensor imaging of the injured cat spinal cord using self-navigated, interleaved, variable-density spiral acquisition (SNAILS-DTI).

    abstract::Diffusion tensor magnetic resonance imaging (DTI) is useful for studying the microstructural changes in the spinal cord following traumatic injury; however, image quality is generally poor due to the small size of the spinal cord, physiological motion and susceptibility artifacts. Self-navigated, interleaved, variable...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.06.006

    authors: Ellingson BM,Sulaiman O,Kurpad SN

    更新日期:2010-11-01 00:00:00

  • Evidence for left-right asymmetries in the proton MRS of brain in normal volunteers.

    abstract::Although there is ample evidence in the literature for structural, functional and physiological asymmetries in the two hemispheres of human brain, direct evidence of a similar asymmetry in the in vivo distribution of brain metabolites has been lacking. In this study, the existence of chemical asymmetries in six differ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00342-6

    authors: Jayasundar R,Raghunathan P

    更新日期:1997-01-01 00:00:00

  • Off-resonance frequency filtered magnetic resonance imaging.

    abstract::One of the main problems with rapid magnetic resonance imaging (MRI) techniques is the artifacts that result from off-resonance effects. The proposed off-resonance frequency filtered MRI (OFF-MRI) method focuses on the elimination of off-resonance components from the image of the observed object. To maintain imaging s...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.12.027

    authors: Medic J,Tomazic S

    更新日期:2010-05-01 00:00:00

  • Lee-Goldburg solid-state imaging.

    abstract::A new approach to solid-state imaging (SSI) is presented. The method relies on narrowing the resonance line using the Lee-Goldburg sequence. The technique is easy to implement in practice and may find widespread applications in materials science. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90409-s

    authors: De Luca F,Lugeri N,De Simone BC,Maraviglia B

    更新日期:1992-01-01 00:00:00

  • Improved sensitivity of MRI in multiple sclerosis by use of extensive standardized procedures.

    abstract::The relative value of two different MRI procedures for the assessment of infratentorial extension in multiple sclerosis (MS) was studied. Multislice spin-echo techniques were used overall. Procedure A consisted of parasagittal T1-weighted images (500/30) and axial T2-weighted images (2500/30, 2500/120). Procedure B co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90547-x

    authors: Van de Vyver FL,Truyen L,Gheuens J,Degryse HR,Peersman GV,Martin JJ

    更新日期:1989-05-01 00:00:00

  • Surface magnetic relaxation in cement pastes.

    abstract::Surface magnetic relaxation in porous media is usually attributed to hindered rotation or to paramagnetic impurities on the surface. In cement pastes, however, it seems reasonable to attribute surface relaxation to dipole interactions in water adsorbed as water of hydration on grain surfaces. The rate limiting factor ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91517-2

    authors: Mendelson KS,Halperin WP,Jehng JY,Song YQ

    更新日期:1994-01-01 00:00:00