Simultaneous acquisition of multiple orders of intermolecular multiple-quantum coherence images in vivo.

Abstract:

:Until recently, NMR imaging with intermolecular multiple-quantum coherences (iMQCs) has been based on the acquisition of a single echo. In vivo studies of iMQC image contrast would greatly benefit from a method that could acquire several orders of quantum coherence during the same acquisition. This would enable comparison of the image contrast for various orders and eliminate image coregistration problems between scans. It has previously been demonstrated that multiple orders of iMQC images can be simultaneously acquired of a simple phantom. Here, we examine the technique and its effect on biological tissue, both in vivo and in vitro. First, we establish the effectiveness of the iMQC sequence in vivo using earthworms as specimens. We then further show that the multi-CRAZED sequence enhances detection of next generation (nanoparticle) contrast agents on excised tumor tissue.

journal_name

Magn Reson Imaging

authors

Shannon KL,Branca RT,Galiana G,Cenzano S,Bouchard LS,Soboyejo W,Warren WS

doi

10.1016/j.mri.2004.10.019

subject

Has Abstract

pub_date

2004-12-01 00:00:00

pages

1407-12

issue

10

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(04)00308-X

journal_volume

22

pub_type

杂志文章
  • Off-resonance correction using an estimated linear time map.

    abstract::Images acquired in the presence of magnetic field deviations and reconstructed without taking into account the off-resonance, are distorted and corrupted with artifacts. Several post-processing algorithms have been developed for correcting the distortion when it is not possible to fix the field inhomogeneities. These ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00487-3

    authors: Akel JA,Rosenblitt M,Irarrazaval P

    更新日期:2002-02-01 00:00:00

  • Empirical optimization of ASL data analysis using an ASL data processing toolbox: ASLtbx.

    abstract::Arterial spin labeling (ASL) perfusion fMRI data differ in important respects from the more familiar blood oxygen level-dependent (BOLD) fMRI data and require specific processing strategies. In this paper, we examined several factors that may influence ASL data analysis, including data storage bit resolution, motion c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.07.003

    authors: Wang Z,Aguirre GK,Rao H,Wang J,Fernández-Seara MA,Childress AR,Detre JA

    更新日期:2008-02-01 00:00:00

  • Off-resonance binomial preparatory pulse technique for high sensitivity MRI of H2O17.

    abstract::H2O17 is a freely diffusible tracer and naturally occurring isotope of O16 detectable by MRI and has been shown to be useful for assessing cerebral perfusion in animal studies using direct and indirect MR detection techniques. However, earlier MR techniques are either not sensitive to changes in small concentrations o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.09.005

    authors: Sood R

    更新日期:2004-02-01 00:00:00

  • Magnetic resonance imaging appearance of metastatic Merkel cell carcinoma to the sacrum and epidural space.

    abstract::Merkel cell carcinoma (MCC) is a rare malignant tumor of the skin and often is diagnosed histologically as lymphoma, melanoma and even metastatic small cell carcinoma of the lung (SCCL). Classified as a neuroendocrine tumor, clinically it originates in the head and neck region and may present with metastatic disease a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00176-4

    authors: Moayed S,Maldjianb C,Adam R,Bonakdarpour A

    更新日期:2000-10-01 00:00:00

  • Evaluation of stacked resonators to enhance the performance of a surface receive-only array for prostate MRI at 3 Tesla.

    abstract::Prostate MRI is an important tool to diagnose and characterize cancer. High local sensitivity and good parallel imaging performance are of paramount importance for diagnostic quality and efficiency. The purpose of this work was to evaluate stacked resonators as part of a surface receiver array for prostate MRI at 3 Te...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.07.010

    authors: Chacon-Caldera J,Fischer A,Malzacher M,Vetter Y,Davids M,Flöser M,Stumpf C,Schad LR

    更新日期:2018-11-01 00:00:00

  • Evaluation of preprocessing steps to compensate for magnetic field distortions due to body movements in BOLD fMRI.

    abstract::Blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) is currently the dominant technique for non-invasive investigation of brain functions. One of the challenges with BOLD fMRI, particularly at high fields, is compensation for the effects of spatiotemporally varying magnetic field inho...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.07.005

    authors: Barry RL,Williams JM,Klassen LM,Gallivan JP,Culham JC,Menon RS

    更新日期:2010-02-01 00:00:00

  • Partial angle inversion recovery (PAIR) MR imaging: spin-echo and snapshot implementation.

    abstract::The effects of varying the inversion or excitation RF pulse flip angles on image contrast and imaging time have been investigated in IR imaging theoretically, with phantoms and with normal volunteers. Signal intensity in an IR pulse sequence as a function of excitation, inversion and refocusing pulse flip angles was c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90481-e

    authors: Vinitski S,Albert S,Mitchell DG,Tasciyan TA,Rifkin MD

    更新日期:1992-01-01 00:00:00

  • Assessing image artifacts from radiotherapy electromagnetic transponders with metal-artifact reduction imaging.

    abstract::Image artifacts due to 14 gauge radiotherapy electromagnetic (EM) transponders were assessed on conventional spin echo images, and corrected using metal artifact reduction techniques: high bandwidth, view angle tilting (VAT), and slice encoding for metal artifact correction (SEMAC). Large areas of signal loss and/or p...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.02.005

    authors: Bergen RV,Ryner L

    更新日期:2019-06-01 00:00:00

  • Active intrahepatic gadolinium extravasation following TIPS.

    abstract::A 31-year-old male patient had a transjugular intrahepatic portal systemic shunt (TIPS) placed for acute Budd-Chiari syndrome secondary to paroxysmal nocturnal hemoglobinuria (PNH). Post-procedure, he was anticoagulated for his underlying paroxysmal nocturnal hemoglobinuria. After 11 days, he complained of upper abdom...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00081-2

    authors: Hasegawa S,Eisenberg LB,Semelka RC

    更新日期:1998-09-01 00:00:00

  • Comparison between end-tidal CO₂ and respiration volume per time for detecting BOLD signal fluctuations during paced hyperventilation.

    abstract::Respiratory motion and capnometry monitoring were performed during blood oxygen level-dependent (BOLD) functional magnetic resonance imaging (fMRI) of the brain while a series of paced hyperventilation tasks were performed that caused significant hypocapnia. Respiration volume per time (RVT) and end-tidal carbon dioxi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.07.011

    authors: Vogt KM,Ibinson JW,Schmalbrock P,Small RH

    更新日期:2011-11-01 00:00:00

  • The relaxivity of Gd-EOB-DTPA and Gd-DTPA in liver and kidney of the Wistar rat.

    abstract::The NMR relaxivities of Gd-EOB-DTPA and Gd-DTPA were determined in the kidney and liver of intact male Wistar rats immediately following sacrifice and in vitro in solutions and gels, at 1.5 T using a clinical MR scanner, T1 and T2 values of tissue samples were derived from spin-echo image sequences. Tissue gadolinium ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02097-d

    authors: Shuter B,Tofts PS,Wang SC,Pope JM

    更新日期:1996-01-01 00:00:00

  • MRI of the normal hippocampus.

    abstract::Before it is possible to use MR imaging to investigate changes in the hippocampus in disease processes such as epilepsy and memory disorders, it is imperative that normal variations are defined. Using specific anatomic locations, we evaluated the hippocampi of 29 normal volunteers with coronal MR studies. Mild variati...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90035-k

    authors: Bronen RA,Cheung G

    更新日期:1991-01-01 00:00:00

  • Quantitative assessment of rat kidney function by measuring the clearance of the contrast agent Gd(DOTA) using dynamic MRI.

    abstract::Magnetic resonance imaging (MRI) has been applied to assess kidney function in normal rats by monitoring the passage of the extracellular contrast agent GdDOTA. High-resolution images have been obtained using either the rapid acquisition with relaxation enhancement (RARE) or the snapshot pulse sequence. The latter was...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00134-x

    authors: Baumann D,Rudin M

    更新日期:2000-06-01 00:00:00

  • N-acetylaspartate reductions measured by 1H MRSI in cognitively impaired HIV-seropositive individuals.

    abstract::We used magnetic resonance imaging (MRI) and water-suppressed proton MR spectroscopic imaging (1H MRSI) to study the effects of human immunodeficiency virus (HIV) infection on the brain. Our recent in vivo finding of lower N-acetylaspartate (NAA), a putative marker of neurons, in the supraventricular brain of cognitiv...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92460-0

    authors: Meyerhoff DJ,MacKay S,Poole N,Dillon WP,Weiner MW,Fein G

    更新日期:1994-01-01 00:00:00

  • Fast T2-mapping with snapshot flash imaging.

    abstract::It has been shown recently that quantitative T2-maps may be measured by acquisition of a series of at least eight T2-weighted SNAPSHOT FLASH images. These measurements require a relaxation delay of 10-15 s after each T2-weighted image for the complete relaxation of the spin system. This results in long measuring times...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00004-z

    authors: Deichmann R,Adolf H,Nöth U,Morrissey S,Schwarzbauer C,Haase A

    更新日期:1995-01-01 00:00:00

  • Quantitative 1H MRS in the evaluation of mesial temporal lobe epilepsy in vivo.

    abstract::Hippocampal metabolite concentrations were determined by localized in vivo proton magnetic resonance spectroscopy (1H MRS) in eleven patients suffering from refractory mesial temporal lobe epilepsy (MTLE), as well as in eleven age-matched healthy volunteers, and compared with patient history, postoperative outcome and...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00123-4

    authors: Duc CO,Trabesinger AH,Weber OM,Meier D,Walder M,Wieser HG,Boesiger P

    更新日期:1998-10-01 00:00:00

  • In vivo muscle magnetic resonance spectroscopy in a family with mitochondrial cytopathy: a defect in fat metabolism.

    abstract::In vivo proton and phosphorus magnetic resonance spectroscopy (MRS) studies were performed at 1.5 T on two patients (siblings) diagnosed as having a mitochondrial cytopathy. The clinical diagnosis was based on a complete battery of biochemical tests, electron microscopy and modified Gomori trichrome stain studies of m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90695-4

    authors: Narayana PA,Slopis JM,Jackson EF,Hazle JD,Kulkarni MV,Butler IJ

    更新日期:1989-03-01 00:00:00

  • Characterization of light hydrocarbon reservoirs by gradient-NMR well logging.

    abstract::New methods for acquiring and processing gradient NMR well log data enable signals from gas, light oil, and water to be unambiguously separated and, in many cases, quantified. These methods exploit the combined effects of T1-based and diffusion-based contrast on log response. T1 contrast, which separates the water and...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00162-2

    authors: Mardon D,Prammer MG,Coates GR

    更新日期:1996-01-01 00:00:00

  • High resolution simultaneous imaging of intracranial and extracranial arterial wall with improved cerebrospinal fluid suppression.

    abstract:PURPOSE:To develop a technique for three dimensional (3D) high resolution joint imaging of intracranial and extracranial arterial walls with improved cerebrospinal fluid (CSF) suppression and good blood suppression based on T1 weighted sampling perfection with application optimized contrast using different angle evolut...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.08.004

    authors: Zhang L,Zhang N,Wu J,Liu X,Chung YC

    更新日期:2017-12-01 00:00:00

  • A NMR characterisation of a banded sandstone.

    abstract::1H-nuclear magnetic resonance (NMR) measurements have been carried out on a banded sandstone to investigate the effects of structural inhomogeneities on the fluid dynamics of the sample as a whole. The results obtained from average propagator measurements (the probability of a displacement z in a time delta or P delta...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00043-5

    authors: Bolam AC,Packer KJ

    更新日期:1998-06-01 00:00:00

  • Localization of ischemia in canine hearts using tagged rotated long axis MR images, endocardial surface stretch and wall thickening.

    abstract::Tagged magnetic resonance imaging allows the noninvasive measurement of regional systolic myocardial deformations and helps localize ischemic regions in the left ventricle (LV). The objective of this study was to evaluate the potential accuracy of localizing ischemic regions in the LV using endocardial and epicardial ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00161-6

    authors: Denisova O,Shapiro EP,Weiss JL,Azhari H

    更新日期:1997-01-01 00:00:00

  • A volume resolution phantom for MRI.

    abstract::Multisite quantitative magnetic resonance imaging (qMRI) of volume requires a small isotropic point spread-function (PSF) that is spatially, temporarily, and platform invariant. A phantom which will allow rapid assessment of this metric throughout the imaged volume without repositioning will assist certification of im...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.07.002

    authors: Moon SY,Hornak JP

    更新日期:2010-02-01 00:00:00

  • Evaluation of solitary pulmonary nodules with dynamic contrast-enhanced MR imaging--a promising technique.

    abstract::The evaluation of a solitary pulmonary nodule (SPN) is one of the most frequently encountered challenges in thoracic radiology. In addition to a "state-of-the-art" evaluation of SPNs with CT and biopsy techniques, recently the assessment of the enhancement characteristics with iodinized contrast agents has shown its p...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02010-q

    authors: Hittmair K,Eckersberger F,Klepetko W,Helbich T,Herold CJ

    更新日期:1995-01-01 00:00:00

  • A simple way to acquire T(1)-weighted MR images of rat liver with respiratory triggering.

    abstract::To acquire high-resolution T(1)-weighted images of the liver in rats, for which breath-holding cannot be ensured, respiratory triggering is essential. At the respiratory rate of 30-60 times/min in rats, however, T(1)-weighted images cannot be obtained with simple triggering. As a simple solution to this, we applied mu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.10.005

    authors: Morikawa S,Murayama H,Fujimoto S,Shiino A,Inubushi T

    更新日期:2012-04-01 00:00:00

  • Effects of trabecular bone on marrow relaxation in the tibia.

    abstract::The effects of bone on marrow relaxation in the trabecular volume of the most proximal 3 cm in the left tibia were studied with a RF-spoiled gradient echo MRI protocol on a 1.0 T MR unit. The MR measurements were performed on six healthy volunteers, and repeated within one month in order to assess the precision of the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00159-3

    authors: Fransson A,Grampp S,Imhof H

    更新日期:1999-01-01 00:00:00

  • Noninvasive evaluation of the regional variations of GABA using magnetic resonance spectroscopy at 3 Tesla.

    abstract:PURPOSE:Rapid regional fluctuations in GABA may result in inhomogeneous concentrations throughout the brain parenchyma. The goal of this study is to provide further insight into the natural distribution of GABA throughout the brain and thus determine if a surrogate site may be used for spectroscopy when evaluating moto...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.02.015

    authors: Durst CR,Michael N,Tustison NJ,Patrie JT,Raghavan P,Wintermark M,Sendhil Velan S

    更新日期:2015-06-01 00:00:00

  • Magnetic resonance imaging: application in musculoskeletal infection.

    abstract::Forty-two patients with clinically suspected osteomyelitis were examined using magnetic resonance imaging (MRI). Twenty-seven patients (64%) had previous surgery or fracture, and 15 (36%) were referred for differentiation of acute osteomyelitis from bone tumors or other pathologic conditions. MRI was compared with com...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90350-9

    authors: Berquist TH,Brown ML,Fitzgerald RH Jr,May GR

    更新日期:1985-01-01 00:00:00

  • Magnetic resonance imaging of mouse Ehrlich carcinoma growth inhibition by thiacarpine, an analogue of cytotoxic marine alkaloid polycarpine.

    abstract::The anticancer effect of thiacarpine, a synthetic analogue of the known cytotoxic alkaloid polycarpine isolated from the Pacific ascidian Polycarpa aurata, was investigated in vivo in experiments using mouse solid Ehrlich carcinoma tumor as the target. A high-resolution magnetic resonance imaging (MRI) technique using...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.01.014

    authors: Agafonova IG,Radchenko OS,Novikov VL,Aminin DL,Stonik VA

    更新日期:2008-07-01 00:00:00

  • A 32-channel coil system for MR vessel wall imaging of intracranial and extracranial arteries at 3T.

    abstract:PURPOSE:To develop a RF coil system for joint imaging of intracranial and extracranial arterial vessel wall at 3T. MATERIALS AND METHOD:The coil system consists of a 24-channel head coil combined with an 8-channel carotid coil. It is compared with a standard coil configuration (12-channel head coil+4-channel neck coil...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.018

    authors: Hu X,Li Y,Zhang L,Zhang X,Liu X,Chung YC

    更新日期:2017-02-01 00:00:00

  • Noncontrast MRI with diffusion-weighted imaging as the sole imaging modality for detecting liver malignancy in patients with high risk for hepatocellular carcinoma.

    abstract:PURPOSE:To compare the diagnostic performance of the noncontrast MRI including DWI to the standard MRI for detecting hepatic malignancies in patients with chronic liver disease. MATERIALS AND METHODS:We included 135 patients with 136 histologically-confirmed hepatocellular carcinomas (HCCs), 12 cholangiocarcinomas, an...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.12.021

    authors: Kim YK,Kim YK,Park HJ,Park MJ,Lee WJ,Choi D

    更新日期:2014-07-01 00:00:00