Magnetic resonance cholangiopancreatography: comparison between respiratory-triggered turbo spin echo and breath hold single-shot turbo spin echo sequences.

Abstract:

:The purpose of this study was to compare the relative conspicuity of the pancreaticobiliary tree on respiratory-triggered three-dimensional turbo spin echo (3D TSE RT) and breath hold single-shot turbo spin echo (SSTSE BH) acquisitions respectively in MRCP imaging. Both techniques were applied to 61 patients with clinically suspected pancreaticobiliary disease using a 1.0 T MR system. All images were reviewed blindly. Qualitative comparison was made by grading subjectively the conspicuity of extrahepatic, intrahepatic, and main pancreatic ducts. Quantitative comparison included calculations of signal-to-noise ratio of the common bile duct, main pancreatic duct, gallbladder, liver, and contrast-to-noise ratio, relative contrast between common bile duct, gallbladder, and liver. 3D TSE RT provided significantly higher signal-to-noise ratio of the common bile duct (mean value 163.19) and main pancreatic duct (mean value 95.37) compared to SSTSE BH (mean values 76.24 and 26.22, respectively). 3D TSE RT was inferior to SSTSE BH for the depiction of intrahepatic ducts and pancreatic duct (head portion). 3D TSE RT and SSTSE BH sequences provide complimentary information in the visualization of the biliary and pancreatic ducts. Further comparative clinical studies are needed to redefine the sensitivity, specificity, and accuracy of MRCP using both sequences.

journal_name

Magn Reson Imaging

authors

Papanikolaou N,Karantanas AH,Heracleous E,Costa JC,Gourtsoyiannis N

doi

10.1016/s0730-725x(99)00074-0

subject

Has Abstract

pub_date

1999-11-01 00:00:00

pages

1255-60

issue

9

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(99)00074-0

journal_volume

17

pub_type

杂志文章
  • The use of power images to perform quantitative analysis on low SNR MR images.

    abstract::Zero-mean noise introduced into quadrature detected MRI signals is generally rectified by the reconstruction algorithm to give a nonzero background intensity in the displayed image. In low signal-to-noise ratio (SNR) images, this background will inflate region of interest (ROI) signal measurements, leading to improper...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90225-3

    authors: Miller AJ,Joseph PM

    更新日期:1993-01-01 00:00:00

  • Short TI short TR inversion recovery imaging using reduced flip angles.

    abstract::In this paper the effects of reducing the flip angle of the 90-degree observation pulse in inversion recovery imaging are described and analyzed. When incorporated in an IR sequence with a short inversion time (STIR), reduction to the 90-degree pulse allows a significant shortening of the repetition time without loss ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90418-l

    authors: Bakker CJ,Witkamp TD,Janssen WM

    更新日期:1991-01-01 00:00:00

  • Short T2 contrast with three-dimensional ultrashort echo time imaging.

    abstract::There is increasing interest in imaging short T2 species which show little or no signal with conventional magnetic resonance (MR) pulse sequences. In this paper, we describe the use of three-dimensional ultrashort echo time (3D UTE) sequences with TEs down to 8 μs for imaging of these species. Image contrast was gener...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.11.003

    authors: Du J,Bydder M,Takahashi AM,Carl M,Chung CB,Bydder GM

    更新日期:2011-05-01 00:00:00

  • Pure uterine lipoma.

    abstract::Lipomatous tumors of the uterus are unusual, benign neoplasms seen in postmenopausal women. Although many of the mixed-type cases such as lipoleiomyoma and fibrolipoma have been reported, pure uterine lipomas are extremely rare. In the literature, a few cases with pure uterine lipoma have been reported. We first prese...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.01.116

    authors: Erdem G,Celik O,Karakas HM,Alkan A,Hascalik S

    更新日期:2007-10-01 00:00:00

  • Development of computer-generated phantoms for FMRI software evaluation.

    abstract::Functional magnetic resonance imaging (FMRI) is a major tool for the evaluation of brain function and architecture. It is widely used by physicians, neuroscientists, psychologists and others. In order to process the data collected using FMRI, it is necessary to use post-acquisition processing software that employs mot...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.04.007

    authors: Pickens DR,Li Y,Morgan VL,Dawant BM

    更新日期:2005-06-01 00:00:00

  • Hepatic sarcoidosis: MR appearances in patients with chronic liver disease.

    abstract:PURPOSE:To describe the MR appearances of hepatic sarcoidosis in patients with chronic liver disease and correlate the results with clinical stage of disease as measured with the Mayo end-stage liver disease (MELD) score. MATERIALS AND METHODS:Twenty patients with chronic liver disease and histopathological diagnosis ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.08.005

    authors: Ferreira A,Ramalho M,de Campos RO,Heredia V,Roque A,Vaidean G,Semelka RC

    更新日期:2013-04-01 00:00:00

  • Evidence for left-right asymmetries in the proton MRS of brain in normal volunteers.

    abstract::Although there is ample evidence in the literature for structural, functional and physiological asymmetries in the two hemispheres of human brain, direct evidence of a similar asymmetry in the in vivo distribution of brain metabolites has been lacking. In this study, the existence of chemical asymmetries in six differ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00342-6

    authors: Jayasundar R,Raghunathan P

    更新日期:1997-01-01 00:00:00

  • Electrophoretic NMR studies of electrical transport in fluid-filled porous systems.

    abstract::An NMR technique is described which allows the observation of ionic charge carriers moving in the electric field within a porous system saturated with electrolyte solution. This method, which was recently developed in our laboratory, gives experimental access to the study of electric transport in disordered media on a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00267-3

    authors: Holz M,Heil SR,Schwab IA

    更新日期:2001-04-01 00:00:00

  • A preliminary study of blood-oxygen-level-dependent MRI in patients with chronic kidney disease.

    abstract:BACKGROUND:Blood-oxygen-level-dependent (BOLD) magnetic resonance imaging (MRI) can provide regional measurements of oxygen content using deoxyhemoglobin paramagnetic characteristics. The apparent relaxation rate or R2*(=1/T2*) can be determined from the slope of log (intensity) versus echo time and is directly proport...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.10.003

    authors: Xin-Long P,Jing-Xia X,Jian-Yu L,Song W,Xin-Kui T

    更新日期:2012-04-01 00:00:00

  • Equivalent cross relaxation rate image for decreasing a false negative case of sentinel lymph node biopsy.

    abstract::In the breast carcinamas, sentinel lymph node biopsy (SLNB) attracts attention as technique to be settled by axillary lymph node metastasis, but existence of a false negative case is a problem. Equivalent cross relaxation rate image (ECRI) is the measurement method that we can evaluate a change of organization structu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00208-x

    authors: Matsushima S,Sasaki F,Sarumaru S,Ohta D,Era S,Sogami M,Inaba T,Kinosada Y

    更新日期:2003-11-01 00:00:00

  • Correlations and dissociations between BOLD signal and P300 amplitude in an auditory oddball task: a parametric approach to combining fMRI and ERP.

    abstract::A parametric method is proposed to examine the relationship between neuronal activity, measured with event related potentials (ERPs), and the hemodynamic response, observed with functional magnetic resonance imaging (fMRI), during an auditory oddball paradigm. After verifying that the amplitude of the evoked response ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00496-4

    authors: Horovitz SG,Skudlarski P,Gore JC

    更新日期:2002-05-01 00:00:00

  • Removal of extracerebral tissues in dual-echo magnetic resonance images via linear scale-space features.

    abstract::The location and masking of the brain and surrounding cerebrospinal fluid (CSF) in two-dimensional (2D) dual-echo fast spin-echo (FSE) magnetic resonance (MR) images of the head is achieved by an automated procedure with a voxel-based computational algorithm. Linear scale-space features are derived from the short-echo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00099-x

    authors: Suckling J,Brammer MJ,Lingford-Hughes A,Bullmore ET

    更新日期:1999-02-01 00:00:00

  • Non-contrast enhanced 3D SSFP MRA of the renal allograft vasculature: a comparison between radial linear combination and Cartesian inflow-weighted acquisitions.

    abstract::Renal transplant patients often require imaging to ensure appropriate graft placement, to assess integrity of transplant vessel anastomosis and to evaluate for stenosis that can be a cause of graft failure. Because there is risk for nephrogenic systemic fibrosis in the setting of renal insufficiency, the use of non-co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.10.004

    authors: Bultman EM,Klaers J,Johnson KM,François CJ,Schiebler ML,Reeder SB,Block WF

    更新日期:2014-02-01 00:00:00

  • Combination of integrated dynamic shimming and readout-segmented echo planar imaging for diffusion weighted MRI of the head and neck region at 3Tesla.

    abstract:PURPOSE:To evaluate the performance of combined integrated slice-by-slice shimming and readout-segmented EPI (irsEPI) for diffusion-weighted MR imaging (DWI) of the neck at 3Tesla. METHODS:This study was approved by the local ethics committee. An anthropometric phantom of the head/neck region incorporating compartment...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.05.004

    authors: Walter SS,Liu W,Stemmer A,Martirosian P,Nikolaou K,Notohamiprodjo M,Gatidis S

    更新日期:2017-10-01 00:00:00

  • A new RF transmit coil for foot and ankle imaging at 7T MRI.

    abstract::A four-channel Tic-Tac-Toe (TTT) transmit RF coil was designed and constructed for foot and ankle imaging at 7T MRI. Numerical simulations using an in-house developed FDTD package and experimental analyses using a homogenous phantom show an excellent agreement in terms of B1+ field distribution and s-parameters. Simul...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.09.005

    authors: Santini T,Kim J,Wood S,Krishnamurthy N,Farhat N,Maciel C,Raval SB,Zhao T,Ibrahim TS

    更新日期:2018-01-01 00:00:00

  • Muscle and fat quantification in MRI gradient echo images using a partial volume detection method. Application to the characterization of pig belly tissue.

    abstract::Complete dissection is the current reference method to quantify muscle and fat tissue on pig carcasses. Magnetic resonance imaging (MRI) is an appropriate nondestructive alternative method that can provide reliable and quantitative information on pig carcass composition without losing the spatial information. We have ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.05.001

    authors: Monziols M,Collewet G,Mariette F,Kouba M,Davenel A

    更新日期:2005-07-01 00:00:00

  • Characterization of light hydrocarbon reservoirs by gradient-NMR well logging.

    abstract::New methods for acquiring and processing gradient NMR well log data enable signals from gas, light oil, and water to be unambiguously separated and, in many cases, quantified. These methods exploit the combined effects of T1-based and diffusion-based contrast on log response. T1 contrast, which separates the water and...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00162-2

    authors: Mardon D,Prammer MG,Coates GR

    更新日期:1996-01-01 00:00:00

  • Characteristics of geometric distortion correction with increasing field-of-view in open-configuration MRI.

    abstract::Open-configuration magnetic resonance imaging (MRI) systems are becoming increasingly desirable for musculoskeletal imaging and image-guided radiotherapy because of their non-claustrophobic configuration. However, geometric image distortion in large fields-of-view (FOV) due to field inhomogeneity and gradient nonlinea...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.02.007

    authors: Hong C,Lee DH,Han BS

    更新日期:2014-07-01 00:00:00

  • Accurate and sensitive measurements of magnetic susceptibility using echo planar imaging.

    abstract::Susceptibility differences are common causes for artifacts in magnetic resonance (MR); therefore, it is important to choose phantom materials in a way that these artifacts are kept at a minimum. In this study, a previously proposed MR imaging (MRI) method [Beuf O, Briguet A, Lissac M, Davis R. Magnetic resonance imagi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.07.005

    authors: Carlsson A,Starck G,Ljungberg M,Ekholm S,Forssell-Aronsson E

    更新日期:2006-11-01 00:00:00

  • A data augmentation approach to train fully convolutional networks for left ventricle segmentation.

    abstract::Left ventricle (LV) segmentation plays an important role in the diagnosis of cardiovascular diseases. The cardiac contractile function can be quantified by measuring the segmentation results of LVs. Fully convolutional networks (FCNs) have been proven to be able to segment images. However, a large number of annotated ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.08.004

    authors: Lin A,Wu J,Yang X

    更新日期:2020-02-01 00:00:00

  • Anisotropic diffusion in etched particle tracks studied by field gradient NMR.

    abstract::Etched particle tracks produced after heavy ion irradiation of polymer foils are used as model systems to test the performance of NMR in a newly developed ultrahigh magnetic field gradient system. The stimulated NMR echo decay of molecules diffusing in the channels, formulated in terms of the self part of the intermed...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91527-x

    authors: Fujara F,Ilyina E,Nienstaedt H,Sillescu H,Spohr R,Trautmann C

    更新日期:1994-01-01 00:00:00

  • Semi-automatic lung segmentation of DCE-MRI data sets of 2-year old children after congenital diaphragmatic hernia repair: Initial results.

    abstract::In congenital diaphragmatic hernia (CDH), lung hypoplasia and secondary pulmonary hypertension are the major causes of death and severe disability. Based on new therapeutic strategies survival rates could be improved to up to 80%. However, after surgical repair of CDH, long-term follow-up of these pediatric patients i...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.08.003

    authors: Zöllner FG,Daab M,Weidner M,Sommer V,Zahn K,Schaible T,Weisser G,Schoenberg SO,Neff KW,Schad LR

    更新日期:2015-12-01 00:00:00

  • SSFP fMRI at 3 tesla: Efficiency of polar acquisition-reconstruction technique.

    abstract::SSFP-based fMRI techniques, known for their high specificity and low geometrical distortion, look promising for high-resolution brain mapping. Nevertheless, they suffer from lack of speed and sensitivity, leading them to be exploited mostly in high-field scanners. Radial acquisition can help with these inefficiencies ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.09.005

    authors: Malekian V,Rastegar F,Shafieizargar B,Nasiraei-Moghaddam A

    更新日期:2020-12-01 00:00:00

  • MRI inter-slice reconstruction using super-resolution.

    abstract::MRI reconstruction using super-resolution is presented and shown to improve spatial resolution in cases when spatially-selective RF pulses are used for localization. In 2-D multislice MRI, the resolution in the slice direction is often lower than the in-plane resolution. For certain diagnostic imaging applications, is...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00511-8

    authors: Greenspan H,Oz G,Kiryati N,Peled S

    更新日期:2002-06-01 00:00:00

  • Ultrashort echo (UTE) versus pointwise encoding time reduction with radial acquisition (PETRA) sequences at 3 Tesla for knee meniscus: A comparative study.

    abstract:PURPOSE:The purposes of this study were to (1) correlate the ultrashort echo time (TE) signal intensity of the pointwise encoding time reduction with radial acquisition (PETRA) sequence with that of the ultrashort echo (UTE) sequence using in vivo meniscal ultrashort TE imaging of the knee with a 3-Tesla (3T) clinical ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.09.003

    authors: Lee YH,Suh JS,Grodzki D

    更新日期:2016-02-01 00:00:00

  • High-resolution magnetic resonance flow imaging in a model of porous bone-implant interface.

    abstract:PURPOSE:To evaluate the application of high-resolution MRI methodology for characterizing the fluid velocity field and evaluate fluid shear field within a simplified in vitro model of a bone-implant interface. MATERIALS AND METHODS:The study used a specific micromotion canine bone implant that has been used for over a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.11.001

    authors: Conroy MJ,Pédrono A,Bechtold JE,Søballe K,Ambard D,Swider P

    更新日期:2006-06-01 00:00:00

  • Relationship between neural and hemodynamic signals during spontaneous activity studied with temporal kernel CCA.

    abstract::Functional magnetic resonance imaging (fMRI) based on the so-called blood oxygen level-dependent (BOLD) contrast is a powerful tool for studying brain function not only locally but also on the large scale. Most studies assume a simple relationship between neural and BOLD activity, in spite of the fact that it is impor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.12.016

    authors: Murayama Y,Biessmann F,Meinecke FC,Müller KR,Augath M,Oeltermann A,Logothetis NK

    更新日期:2010-10-01 00:00:00

  • Evaluation of pancreatic exocrine insufficiency by cine-dynamic MRCP using spatially selective inversion-recovery (IR) pulse: Correlation with severity of chronic pancreatitis based on morphological changes of pancreatic duct.

    abstract:PURPOSE:To evaluate the correlation between the pancreatic exocrine insufficiency estimated by cine-dynamic MRCP using spatially selective IR pulse and the severity stages (modified Cambridge classification) based on morphological changes of the pancreatic duct in patients with suspected chronic pancreatitis. MATERIAL...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.12.007

    authors: Yasokawa K,Ito K,Kanki A,Yamamoto A,Torigoe T,Sato T,Tamada T

    更新日期:2018-05-01 00:00:00

  • Functional MR imaging in the awake monkey: effects of motion on dynamic off-resonance and processing strategies.

    abstract::Functional MR imaging of the alert, behaving monkey is being used more and more often to detect activation patterns and guide electrophysiological research investigating the neural basis of behavior. Several labs have reported fMRI data from the awake monkey, but none of them has studied and systematically corrected t...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.002

    authors: Pfeuffer J,Shmuel A,Keliris GA,Steudel T,Merkle H,Logothetis NK

    更新日期:2007-07-01 00:00:00

  • Alterations in diffusion properties of white matter in Williams syndrome.

    abstract::Diffusion tensor imaging (DTI) was used to investigate the involvement of brain white matter in Williams syndrome (WS), a genetic neurodevelopmental disorder. Whole-brain DTIs were obtained from 16 young adults with WS and 16 normal controls. A voxel-based analysis was performed to compare fractional anisotropy (FA) v...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.07.012

    authors: Arlinghaus LR,Thornton-Wells TA,Dykens EM,Anderson AW

    更新日期:2011-11-01 00:00:00