Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging.

Abstract:

:Geometric distortion in MR imaging predominantly arises from the inhomogeneity of the static field and the nonlinearity of the gradients. It is the purpose of this paper to analyse the object and machine related contributions to geometric distortion in order to determine which corrections are necessary for attaining a specified precision. System related imperfections were measured by systematic variation of the strength, direction, and polarity of the read-out gradient in imaging experiments on a grid of cylindrical sample tubes. For the 1.5-T system used in this study, static field related errors up to 7 mm and gradient related errors up to 4 mm were observed (midcoronal plane, FOV 400-mm, G-read between 0.5 and 3.0 mT/m). Field related errors were shown to be inversely proportional to gradient strength, whereas gradient related errors turned out to be virtually independent of gradient strength. It therefore seems recommendable to always apply the strongest available selection and read-out gradients when geometric fidelity is given preference to signal-to-noise considerations. Correction of system related geometric distortions in MR images can readily be performed by table lookup. Object-induced distortions of the gradient fields were studied by experiments on a grid of sample tubes immersed into a cylindrical water bath of variable saline concentration. These experiments revealed a negligible influence of the object on the gradient error distribution, and lead to the conclusion that correction for the nonlinearity of the gradients only requires the application of system dependent correction factors. Object-related distortions of B0 were studied by conventional SE and fat-suppressed IR experiments on phantoms and human subjects. In these experiments the polarity of the read-out gradient was reversed. Subtraction images showed significant object-induced inhomogeneities of the static field at tissue-air interfaces and in the immediate vicinity of the object being imaged. A first attempt to correct for object related B0 inhomogeneities was made by contour analysis of the source images. At present this correction still has to be done manually.

journal_name

Magn Reson Imaging

authors

Bakker CJ,Moerland MA,Bhagwandien R,Beersma R

doi

10.1016/0730-725x(92)90011-n

subject

Has Abstract

pub_date

1992-01-01 00:00:00

pages

597-608

issue

4

eissn

0730-725X

issn

1873-5894

pii

0730-725X(92)90011-N

journal_volume

10

pub_type

杂志文章
  • A functionalized superparamagnetic iron oxide colloid as a receptor directed MR contrast agent.

    abstract::We have synthesized a surface functionalized superparamagnetic iron oxide colloid whose clearance from the vascular compartment was inhibited by asialofetuin but not fetuin. Unlike other particulate or colloidal magnetic resonance (MR) contrast agents, the agent of the current communication is not withdrawn from the v...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90143-p

    authors: Josephson L,Groman EV,Menz E,Lewis JM,Bengele H

    更新日期:1990-01-01 00:00:00

  • Quantitation of normal canine hippocampus formation volume: correlation of MRI with gross histology.

    abstract::The hippocampal formation possesses an important role in the development and maintenance of short-term memory. In this study, magnetic resonance imaging (MRI) and gross histology were used to quantify the volume of the hippocampal formation in canines. High resolution MRI, using 1 mm thick slices and an intraplanar re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02083-6

    authors: Vullo T,Deo-Narine V,Stallmeyer MJ,Gomez DG,Cahill PT

    更新日期:1996-01-01 00:00:00

  • Imaging of HDR brachytherapy dose distributions using NMR Fricke-gelatin dosimetry.

    abstract::The application of NMR Fricke-gelatin dosimetry to the imaging of dose distributions around high dose rate (HDR) radioactive Ir-192 seeds in brachytherapy is presented. The duration of the irradiations required to give changes of the Fricke-gelatin NMR characteristics, which were readily detected by the magnetic reson...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92031-1

    authors: Schreiner LJ,Crooks I,Evans MD,Keller BM,Parker WA

    更新日期:1994-01-01 00:00:00

  • Chiari malformation type I: a new MRI classification.

    abstract::Thirty patients with Chiari I malformation were examined by MRI over 2-year period. All patients underwent MRI scan before and after surgical decompression of the posterior fossa. Images of the craniocervical junction confirmed tonsillar herniation in all cases and allowed the definition of two anatomically distinct t...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00383-9

    authors: Amer TA,el-Shmam OM

    更新日期:1997-01-01 00:00:00

  • High-resolution MR venography of cerebral arteriovenous malformations.

    abstract::The purpose of this study was to evaluate the diagnostic potential of a high-resolution magnetic resonance (MR) venography technique in patients with cerebral arteriovenous malformations (AVMs). A high-resolution 3D gradient echo sequence was used with a long echo time TE to obtain venous information down to sub-pixel...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00084-3

    authors: Essig M,Reichenbach JR,Schad LR,Schoenberg SO,Debus J,Kaiser WA

    更新日期:1999-12-01 00:00:00

  • Spatial heterogeneity in the muscle functional MRI signal intensity time course: effect of exercise intensity.

    abstract::It has previously been observed that during isometric dorsiflexion exercise, the time course of T2-weighted signal intensity (SI) changes is spatially heterogeneous. The purpose of this study was to test the hypothesis that this spatial heterogeneity would increase at higher contraction intensities. Eight subjects per...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.01.023

    authors: Damon BM,Wadington MC,Lansdown DA,Hornberger JL

    更新日期:2008-10-01 00:00:00

  • Muscle and fat quantification in MRI gradient echo images using a partial volume detection method. Application to the characterization of pig belly tissue.

    abstract::Complete dissection is the current reference method to quantify muscle and fat tissue on pig carcasses. Magnetic resonance imaging (MRI) is an appropriate nondestructive alternative method that can provide reliable and quantitative information on pig carcass composition without losing the spatial information. We have ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.05.001

    authors: Monziols M,Collewet G,Mariette F,Kouba M,Davenel A

    更新日期:2005-07-01 00:00:00

  • Diffusion-weighted imaging versus superparamagnetic iron oxide (SPIO)-enhanced MRI: exclusive and combined values in the assessment of hepatic metastases.

    abstract:PURPOSE:The purpose was to validate diffusion-weighted imaging (DWI) in the assessment of hepatic metastases compared with superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance imaging. MATERIALS AND METHODS:For 21 consecutive patients with 160 metastases from extrahepatic malignancy and 25 benign focal lesi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.12.007

    authors: Kim H,Yu JS,Cho ES,Chung JJ,Kim JH,Kim DJ,Ahn JH,Kim KW

    更新日期:2012-05-01 00:00:00

  • A new RF transmit coil for foot and ankle imaging at 7T MRI.

    abstract::A four-channel Tic-Tac-Toe (TTT) transmit RF coil was designed and constructed for foot and ankle imaging at 7T MRI. Numerical simulations using an in-house developed FDTD package and experimental analyses using a homogenous phantom show an excellent agreement in terms of B1+ field distribution and s-parameters. Simul...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.09.005

    authors: Santini T,Kim J,Wood S,Krishnamurthy N,Farhat N,Maciel C,Raval SB,Zhao T,Ibrahim TS

    更新日期:2018-01-01 00:00:00

  • Dependence of temporal diffusion spectra on microstructural properties of biological tissues.

    abstract::The apparent diffusion coefficient (ADC) measured using magnetic resonance imaging methods provides information on microstructural properties of biological tissues, and thus has found applications as a useful biomarker for assessing changes such as those that occur in ischemic stroke and cancer. Conventional pulsed gr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.10.002

    authors: Xu J,Does MD,Gore JC

    更新日期:2011-04-01 00:00:00

  • Evaluation of water content by spatially resolved transverse relaxation times of human articular cartilage.

    abstract::Non-invasive assessment of cartilage properties, specifically water content, could prove helpful in the diagnosis of early degenerative joint diseases. Transverse relaxation times T(2) of human articular cartilage (34 cartilage slices of three donors) were measured on a pixel-by-pixel basis in a clinical whole body MR...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00144-7

    authors: Lüsse S,Claassen H,Gehrke T,Hassenpflug J,Schünke M,Heller M,Glüer CC

    更新日期:2000-05-01 00:00:00

  • Reducing motion artifacts in two-dimensional Fourier transform imaging.

    abstract::The effects of motion in two-dimensional Fourier transform imaging (2DFT) are considered. Specific calculations describing the case of periodic motion are presented. The results predict the commonly seen artifact of image replication, sometimes referred to as ghosting. Expressions for both position and amplitude of th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(86)91046-5

    authors: Haacke EM,Patrick JL

    更新日期:1986-01-01 00:00:00

  • Visualization of Taylor-Couette and spiral Poiseuille flows using a snapshot FLASH spatial tagging sequence.

    abstract::A new magnetic resonance imaging technique was applied to the Taylor-Couette and spiral Poiseuille (Taylor-Couette with superposed mean axial flux) flows for the first time. The experimental technique is a combination of spatial tagging methods and a snapshot FLASH imaging sequence, which allows the full-field visuali...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00121-6

    authors: Moser KW,Raguin LG,Harris A,Morris HD,Georgiadis J,Shannon M,Philpott M

    更新日期:2000-02-01 00:00:00

  • Characterisation of crosslinked elastomeric materials by 1H NMR relaxation time distributions.

    abstract::One of the most critical structural parameters in elastomeric materials is the density of cross-linking between the polymeric chains. This chemical feature greatly affects chain motions and is determinant in controlling mechanical properties of the final product. NMR techniques are widely and efficiently applied to in...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00257-0

    authors: Borgia GC,Fantazzini P,Ferrando A,Maddinelli G

    更新日期:2001-04-01 00:00:00

  • The use of power images to perform quantitative analysis on low SNR MR images.

    abstract::Zero-mean noise introduced into quadrature detected MRI signals is generally rectified by the reconstruction algorithm to give a nonzero background intensity in the displayed image. In low signal-to-noise ratio (SNR) images, this background will inflate region of interest (ROI) signal measurements, leading to improper...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90225-3

    authors: Miller AJ,Joseph PM

    更新日期:1993-01-01 00:00:00

  • Pulsed arterial spin labeling perfusion imaging at 3 T: estimating the number of subjects required in common designs of clinical trials.

    abstract::Pulsed arterial spin labeling (PASL) is an increasingly common technique for noninvasively measuring cerebral blood flow (CBF) and has previously been shown to have good repeatability. It is likely to find a place in clinical trials and in particular the investigation of pharmaceutical agents active in the central ner...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.02.030

    authors: Murphy K,Harris AD,Diukova A,Evans CJ,Lythgoe DJ,Zelaya F,Wise RG

    更新日期:2011-12-01 00:00:00

  • The lever-coil: a simple, inexpensive sensor for respiratory and cardiac motion in MRI experiments.

    abstract::Thoracic and abdominal magnetic resonance imaging studies generally require some type of compensation for respiratory and cardiac motions in order to yield artifact-free images with good signal-to-noise ratio. Most techniques for respiratory compensation require the use of a non-NMR sensing device to monitor the subje...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00403-9

    authors: Fishbein KW,McConville P,Spencer RG

    更新日期:2001-07-01 00:00:00

  • Spiral demystified.

    abstract::Spiral acquisition schemes offer unique advantages such as flow compensation, efficient k-space sampling and robustness against motion that make this option a viable choice among other non-Cartesian sampling schemes. For this reason, the main applications of spiral imaging lie in dynamic magnetic resonance imaging suc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2010.03.036

    authors: Delattre BM,Heidemann RM,Crowe LA,Vallée JP,Hyacinthe JN

    更新日期:2010-07-01 00:00:00

  • Rapid acquisition strategy for functional T1ρ mapping of the brain.

    abstract::Functional T1ρ mapping has been proposed as a method to assess pH and metabolism dynamics in the brain with high spatial and temporal resolution. The purpose of this work is to describe and evaluate a variant of the spin-locked echo-planar imaging sequence for functional T1ρ mapping at 3T. The proposed sequence rapidl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.07.010

    authors: Johnson CP,Heo HY,Thedens DR,Wemmie JA,Magnotta VA

    更新日期:2014-11-01 00:00:00

  • A two-compartment phosphate-doped gel phantom for localized spectroscopy.

    abstract::Acrylamide gel loaded with phosphate has been used in two compartment phantoms designed to assess localized spectroscopy techniques. A chemical shift difference of 2.3 ppm was produced by changing the pH from 6 to 8.9. The 31P relaxation times were modified by doping the gels with paramagnetic ions. For a T1 of approx...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90381-9

    authors: Howe FA,Griffiths JR

    更新日期:1992-01-01 00:00:00

  • Hair product artifact in magnetic resonance imaging.

    abstract::The presence of metallic compounds in facial cosmetics and permanent tattoos may affect the quality of magnetic resonance imaging. We report a case study describing a signal artifact due to the use of a leave-on powdered hair dye. On reviewing the ingredients of the product, it was found to contain several metallic co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.08.023

    authors: Chenji S,Wilman AH,Mah D,Seres P,Genge A,Kalra S

    更新日期:2017-01-01 00:00:00

  • Issues about the fMRI of the human spinal cord.

    abstract::Noninvasive functional studies on human spinal cord by means of magnetic resonance imaging (MRI) are gaining attention because of the promising applications in the study of healthy and injured central nervous system. The findings obtained are generally consistent with the anatomic knowledge based on invasive methods, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.10.015

    authors: Giove F,Garreffa G,Giulietti G,Mangia S,Colonnese C,Maraviglia B

    更新日期:2004-12-01 00:00:00

  • Combination of integrated dynamic shimming and readout-segmented echo planar imaging for diffusion weighted MRI of the head and neck region at 3Tesla.

    abstract:PURPOSE:To evaluate the performance of combined integrated slice-by-slice shimming and readout-segmented EPI (irsEPI) for diffusion-weighted MR imaging (DWI) of the neck at 3Tesla. METHODS:This study was approved by the local ethics committee. An anthropometric phantom of the head/neck region incorporating compartment...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.05.004

    authors: Walter SS,Liu W,Stemmer A,Martirosian P,Nikolaou K,Notohamiprodjo M,Gatidis S

    更新日期:2017-10-01 00:00:00

  • Computerized quantification of carotid artery stenosis using MRA axial images.

    abstract::Currently, the North American symptomatic carotid endarterectomy trial, European carotid surgery trial, and common carotid method are used to measure the carotid stenosis for determining candidates for carotid endarterectomy using the projection angiography from different modalities such as digital subtraction angiogr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.007

    authors: Kim DY,Park JW

    更新日期:2004-04-01 00:00:00

  • Water diffusion in biological porous systems: a NMR approach.

    abstract::The spin-echo nuclear magnetic resonance (NMR) technique together with paramagnetic ion doping are used to study structural parameters of plant samples, such as restricted dimensions, and cell interconnection both through membranes and by cell contact by studying simultaneous restricted diffusion and intercellular wat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00053-8

    authors: Anisimov AV,Sorokina NY,Dautova NR

    更新日期:1998-06-01 00:00:00

  • Agarose as a tissue equivalent phantom material for NMR imaging.

    abstract::Phantoms for evaluation of nuclear magnetic resonance (NMR) imaging systems were made from water-based agarose gels, according to a standard procedure herein described. Copper sulfate (CuSO4) was included in the gels to further affect their proton relaxation characteristics. The proton relaxation rates of each batch o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(86)91068-4

    authors: Mitchell MD,Kundel HL,Axel L,Joseph PM

    更新日期:1986-01-01 00:00:00

  • MRI of the anal canal: correlation with histologic examination.

    abstract::The purpose of this study was to correlate the MRI features of the anal canal with histologic findings. T1- and T2-weighted MR images of nine anal canals were obtained after fixation in 10% formalin. In three specimens, imaging was repeated after removal of histologic layers with a dissecting microscope. Corresponding...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02056-y

    authors: Van Beers BE,Kartheuser A,Delos MA,Grandin C,Detry R,Jamart J,Pringot J

    更新日期:1996-01-01 00:00:00

  • Accurate and sensitive measurements of magnetic susceptibility using echo planar imaging.

    abstract::Susceptibility differences are common causes for artifacts in magnetic resonance (MR); therefore, it is important to choose phantom materials in a way that these artifacts are kept at a minimum. In this study, a previously proposed MR imaging (MRI) method [Beuf O, Briguet A, Lissac M, Davis R. Magnetic resonance imagi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.07.005

    authors: Carlsson A,Starck G,Ljungberg M,Ekholm S,Forssell-Aronsson E

    更新日期:2006-11-01 00:00:00

  • Lee-Goldburg solid-state imaging.

    abstract::A new approach to solid-state imaging (SSI) is presented. The method relies on narrowing the resonance line using the Lee-Goldburg sequence. The technique is easy to implement in practice and may find widespread applications in materials science. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90409-s

    authors: De Luca F,Lugeri N,De Simone BC,Maraviglia B

    更新日期:1992-01-01 00:00:00

  • 3D cerebrovascular segmentation combining fuzzy vessel enhancement and level-sets with anisotropic energy weights.

    abstract::The aim of this work is to present and evaluate a level-set segmentation approach with vesselness-dependent anisotropic energy weights, which focuses on the exact segmentation of malformed as well as small vessels from time-of-flight (TOF) magnetic resonance angiography (MRA) datasets. In a first step, a vesselness fi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.07.008

    authors: Forkert ND,Schmidt-Richberg A,Fiehler J,Illies T,Möller D,Säring D,Handels H,Ehrhardt J

    更新日期:2013-02-01 00:00:00