Gadolinium-enhanced magnetic resonance angiography of renal transplants.

Abstract:

:Our purpose was to investigate three-dimensional (3D) gadolinium-enhanced magnetic resonance angiography (Gd-MRA) in the evaluation of renal transplant arteries. Eleven MR angiography examinations were performed in nine renal transplant patients. Gd-MRA, three-dimensional phase contrast (3D-PC) post-gadolinium, and two-dimensional time-of-flight (2D-TOF) MR angiography were performed and independently reviewed by three vascular radiologists who, for each MR angiography sequence, separately graded occlusive disease in the ipsilateral iliac artery, the transplant artery anastomosis, and the transplant artery itself. The Gd-MRA and 3D-PC data were reviewed as maximum intensity projections (MIP) reconstructed in standard planes, and the 2D-TOF data were interpreted from source images. In addition, a single vascular radiologist prospectively interpreted the Gd-MRA and 3D-PC data together, hereinafter Gd/PC, from MIP reconstructions for each case. In all of these patients either surgical (n = 3) or angiographic studies (n = 8) were performed within 21 days following the MR examination, which served as a reference standard to determine sensitivity and specificity. The sensitivity/specificity for the detection of significant stenosis were as follows: Gd-MRA, 67/88; 3D-PC, 60.3/76.6; 2D-TOF, 47/81; and Gd/PC, 100/100. The kappa statistic (kappa) for interobserver agreement for the grading of stenoses by 2D-TOF, Gd-PC, and Gd-MRA was 0.48, 0.60, and 0.74, respectively. The percentage of all vascular segments seen well enough to grade (cumulative for all three observers) was 94%, 85%, and 79% for Gd-MRA, 3D-PC, and 2D-TOF, respectively. The combination of Gd-MRA and 3D-PC is a promising approach to the evaluation of transplant renal arteries.

journal_name

Magn Reson Imaging

authors

Johnson DB,Lerner CA,Prince MR,Kazanjian SN,Narasimham DL,Leichtman AB,Cho KJ

doi

10.1016/s0730-725x(96)00348-7

subject

Has Abstract

pub_date

1997-01-01 00:00:00

pages

13-20

issue

1

eissn

0730-725X

issn

1873-5894

pii

S0730725X96003487

journal_volume

15

pub_type

杂志文章
  • MR characteristics of neoplasms and vascular malformations associated with epilepsy.

    abstract::We assessed the magnetic resonance (MR) imaging characteristics of two categories of epileptogenic substrates, neoplasms, and vascular malformations, to determine MR sensitivity and typical imaging features. A blinded retrospective analysis was performed on MR scans from 41 patients who had a neoplasm or vascular malf...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02026-p

    authors: Bronen RA,Fulbright RK,Spencer DD,Spencer SS,Kim JH,Lange RC

    更新日期:1995-01-01 00:00:00

  • Diffusion pore imaging with generalized temporal gradient profiles.

    abstract::In porous material research, one main interest of nuclear magnetic resonance diffusion (NMR) experiments is the determination of the shape of pores. While it has been a longstanding question if this is in principle achievable, it has been shown recently that it is indeed possible to perform NMR-based diffusion pore im...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.03.027

    authors: Laun FB,Kuder TA

    更新日期:2013-09-01 00:00:00

  • Recreational runners with patellofemoral pain exhibit elevated patella water content.

    abstract::Increased bone water content resulting from repetitive patellofemoral joint overloading has been suggested to be a possible mechanism underlying patellofemoral pain (PFP). To date, it remains unknown whether persons with PFP exhibit elevated bone water content. The purpose of this study was to determine whether recrea...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.04.018

    authors: Ho KY,Hu HH,Colletti PM,Powers CM

    更新日期:2014-09-01 00:00:00

  • A new method for diffusion weighted imaging.

    abstract::A new method for generating diffusion contrast in magnetic resonance imaging is presented. This technique is robust enough to allow implementation on conventional imaging systems without hardware modifications. Results from phantom measurements are reported. Qualitative contrast changes in magnetic resonance images de...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90069-p

    authors: Norwood TJ,Williams SC

    更新日期:1993-01-01 00:00:00

  • A new RF transmit coil for foot and ankle imaging at 7T MRI.

    abstract::A four-channel Tic-Tac-Toe (TTT) transmit RF coil was designed and constructed for foot and ankle imaging at 7T MRI. Numerical simulations using an in-house developed FDTD package and experimental analyses using a homogenous phantom show an excellent agreement in terms of B1+ field distribution and s-parameters. Simul...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.09.005

    authors: Santini T,Kim J,Wood S,Krishnamurthy N,Farhat N,Maciel C,Raval SB,Zhao T,Ibrahim TS

    更新日期:2018-01-01 00:00:00

  • Diffusion of liquids into semicrystalline polyethylene.

    abstract::Pulsed field gradient (PFG) nuclear magnetic resonance (NMR) and microimaging experiments have been performed to study the diffusion of liquid alkanes into a variety of semicrystalline polyethylene (PE) samples. The results highlight the importance of the crystalline phase in controlling the diffusion process in terms...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00032-0

    authors: Harding SG,Gladden LF

    更新日期:1998-06-01 00:00:00

  • High-resolution in vivo diffusion tensor imaging of the injured cat spinal cord using self-navigated, interleaved, variable-density spiral acquisition (SNAILS-DTI).

    abstract::Diffusion tensor magnetic resonance imaging (DTI) is useful for studying the microstructural changes in the spinal cord following traumatic injury; however, image quality is generally poor due to the small size of the spinal cord, physiological motion and susceptibility artifacts. Self-navigated, interleaved, variable...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.06.006

    authors: Ellingson BM,Sulaiman O,Kurpad SN

    更新日期:2010-11-01 00:00:00

  • Magnetic resonance spectroscopy of the brain in neurologically asymptomatic HIV-infected patients.

    abstract::The CNS involvement is frequently found in human immunodeficiency virus (HIV) infection. The purpose of our study was to determine whether proton magnetic resonance spectroscopy (MRS) could detect early brain involvement in neurologically asymptomatic HIV-infected patients with normal MR imagings and to find the corre...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0730-725x(00)00173-9

    authors: Suwanwelaa N,Phanuphak P,Phanthumchinda K,Suwanwela NC,Tantivatana J,Ruxrungtham K,Suttipan J,Wangsuphachart S,Hanvanich M

    更新日期:2000-09-01 00:00:00

  • Temporal sampling requirements for the tracer kinetics modeling of breast disease.

    abstract::The physiological parameters measured in the tracer kinetics modeling of data from a dynamic contrast-enhanced magnetic resonance (MR) breast exam (blood flow-extraction fraction product [FE], volume of the extracellular extravascular space [Ve], and blood volume [Vb]) may enable non-invasive diagnosis of breast cance...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00130-1

    authors: Henderson E,Rutt BK,Lee TY

    更新日期:1998-11-01 00:00:00

  • Parallel imaging for first-pass myocardial perfusion.

    abstract::Two parallel imaging methods used for first-pass myocardial perfusion imaging were compared in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image artifacts. One used adaptive Time-adaptive SENSitivity Encoding (TSENSE) and the other used GeneRalized Autocalibrating Partially Parallel Acquisi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.10.012

    authors: Irwan R,Lubbers DD,van der Vleuten PA,Kappert P,Götte MJ,Sijens PE

    更新日期:2007-06-01 00:00:00

  • Using nine degrees-of-freedom registration to correct for changes in voxel size in serial MRI studies.

    abstract::Quantitative longitudinal brain magnetic resonance (MR) studies may be confounded by scanner-related drifts in voxel sizes. Total intracranial volume (TIV) normalisation is commonly used to correct serial cerebral volumetric measurements for these drifts. We hypothesised that automated rigid-body registration of whole...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.057

    authors: Whitwell JL,Schott JM,Lewis EB,MacManus DG,Fox NC

    更新日期:2004-09-01 00:00:00

  • Background parenchymal enhancement in the contralateral normal breast of patients undergoing neoadjuvant chemotherapy measured by DCE-MRI.

    abstract::The purpose of this study was to analyze background parenchymal enhancement (BPE) in the contralateral normal breast of cancer patients during the course of neoadjuvant chemotherapy (NAC). Forty-five subjects were analyzed. Each patient had three MRIs, one baseline (B/L) and two follow-up (F/U) studies. The fibrogland...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.014

    authors: Chen JH,Yu H,Lin M,Mehta RS,Su MY

    更新日期:2013-11-01 00:00:00

  • The relaxivity of Gd-EOB-DTPA and Gd-DTPA in liver and kidney of the Wistar rat.

    abstract::The NMR relaxivities of Gd-EOB-DTPA and Gd-DTPA were determined in the kidney and liver of intact male Wistar rats immediately following sacrifice and in vitro in solutions and gels, at 1.5 T using a clinical MR scanner, T1 and T2 values of tissue samples were derived from spin-echo image sequences. Tissue gadolinium ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02097-d

    authors: Shuter B,Tofts PS,Wang SC,Pope JM

    更新日期:1996-01-01 00:00:00

  • Abdominal imaging studies: comparison of diagnostic accuracies resulting from ultrasound, computed tomography, and magnetic resonance imaging in the same individual.

    abstract::We retrospectively compared the diagnostic accuracy of abdominal ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI) studies performed on the same individual to determine the relative performance of these modalities in the evaluation of disease processes, arising from different intra-abdomi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.01.001

    authors: Noone TC,Semelka RC,Chaney DM,Reinhold C

    更新日期:2004-01-01 00:00:00

  • Determination of relaxation characteristics during preacute stage of lysophosphatidyl choline-induced demyelinating lesion in rat brain: an animal model of multiple sclerosis.

    abstract::Relaxation time measurements were carried out during the preacute stage of lesion progression in an animal model of demyelination created in the internal capsule (ic) area of the rat brain using lysophosphatidyl choline (LPC). T1 and T2 were determined both before and after 36 h of lesion creation. Histology carried o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.11.010

    authors: Degaonkar MN,Raghunathan P,Jayasundar R,Jagannathan NR

    更新日期:2005-01-01 00:00:00

  • Comparison of dynamic contrast-enhanced magnetic resonance imaging and contrast-enhanced ultrasound for evaluation of the effects of sorafenib in a rat model of hepatocellular carcinoma.

    abstract:OBJECTIVES:To compare the accuracy of contrast-enhanced ultrasound (CEUS) and Dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) for the assessment of changes in tissue vascularization as result of sorafenib treatment in a rat model of hepatocellular carcinoma (HCC). METHODS:Male Buffalo rats with orthot...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.11.012

    authors: Muñoz NM,Minhaj AA,Maldonado KL,Kingsley CV,Cortes AC,Taghavi H,Polak U,Mitchell JM,Ensor JE,Bankson JA,Rashid A,Avritscher R

    更新日期:2019-04-01 00:00:00

  • The comparison of the performance of 3 T and 7 T T2 mapping for untreated low-grade cartilage lesions.

    abstract:OBJECTIVE:To investigate T2 mapping as a possible marker for low-grade human articular cartilage lesions during a one-year follow-up, possible changes during the follow-up and compare the reliability and sensitivity of these measurements on high-field (3 T) and ultra-high-field (7 T) MRI scanners. DESIGN:Twenty-one pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.09.021

    authors: Juras V,Schreiner M,Laurent D,Zbýň Š,Mlynarik V,Szomolanyi P,Hager B,Scotti C,Goldhahn J,Heule R,Bieri O,Trattnig S

    更新日期:2019-01-01 00:00:00

  • Electric stimulation fMRI of the perforant pathway to the rat hippocampus.

    abstract::The hippocampal formation is a brain system that is implicated in learning and memory. The major input to the hippocampus arrives from the entorhinal cortex (EC) to the dentate gyrus (DG) through the perforant path. In the present work, we have investigated the functional properties of this connection by concomitantly...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.02.018

    authors: Canals S,Beyerlein M,Murayama Y,Logothetis NK

    更新日期:2008-09-01 00:00:00

  • Surface magnetic relaxation in cement pastes.

    abstract::Surface magnetic relaxation in porous media is usually attributed to hindered rotation or to paramagnetic impurities on the surface. In cement pastes, however, it seems reasonable to attribute surface relaxation to dipole interactions in water adsorbed as water of hydration on grain surfaces. The rate limiting factor ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91517-2

    authors: Mendelson KS,Halperin WP,Jehng JY,Song YQ

    更新日期:1994-01-01 00:00:00

  • Magnetic resonance imaging of mouse Ehrlich carcinoma growth inhibition by thiacarpine, an analogue of cytotoxic marine alkaloid polycarpine.

    abstract::The anticancer effect of thiacarpine, a synthetic analogue of the known cytotoxic alkaloid polycarpine isolated from the Pacific ascidian Polycarpa aurata, was investigated in vivo in experiments using mouse solid Ehrlich carcinoma tumor as the target. A high-resolution magnetic resonance imaging (MRI) technique using...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.01.014

    authors: Agafonova IG,Radchenko OS,Novikov VL,Aminin DL,Stonik VA

    更新日期:2008-07-01 00:00:00

  • Proton electron double resonance imaging of free radical distribution in environmental science applications--first results and perspectives.

    abstract::In this contribution, we explore the potential of proton electron double resonance imaging (PEDRI) in environmental science (hydrogeological) applications. After a discussion of the hydrogeological motivation for studies of free radical transport in environmental matrices, we present results from first experiments tha...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.11.027

    authors: Nestle N,Shet K,Lurie DJ

    更新日期:2005-02-01 00:00:00

  • Correction of partial volume inaccuracies in quantitative phase contrast MR angiography.

    abstract::The phase difference method of phase contrast MR angiography provides a means of measuring the average velocity in each voxel of an MR scan. When static tissue is present in a voxel containing flow, the measured velocity is not the average velocity of the flow alone, but is lower due to the partial volume effect of th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91245-r

    authors: Hamilton CA

    更新日期:1994-01-01 00:00:00

  • Application of machine learning methods to describe the effects of conjugated equine estrogens therapy on region-specific brain volumes.

    abstract::Use of conjugated equine estrogens (CEE) has been linked to smaller regional brain volumes in women aged ≥65 years; however, it is unknown whether this results in a broad-based characteristic pattern of effects. Structural magnetic resonance imaging was used to assess regional volumes of normal tissue and ischemic les...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.mri.2010.12.001

    authors: Casanova R,Espeland MA,Goveas JS,Davatzikos C,Gaussoin SA,Maldjian JA,Brunner RL,Kuller LH,Johnson KC,Mysiw WJ,Wagner B,Resnick SM,Women's Health Initiative Memory Study.

    更新日期:2011-05-01 00:00:00

  • Hair product artifact in magnetic resonance imaging.

    abstract::The presence of metallic compounds in facial cosmetics and permanent tattoos may affect the quality of magnetic resonance imaging. We report a case study describing a signal artifact due to the use of a leave-on powdered hair dye. On reviewing the ingredients of the product, it was found to contain several metallic co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.08.023

    authors: Chenji S,Wilman AH,Mah D,Seres P,Genge A,Kalra S

    更新日期:2017-01-01 00:00:00

  • Issues about the fMRI of the human spinal cord.

    abstract::Noninvasive functional studies on human spinal cord by means of magnetic resonance imaging (MRI) are gaining attention because of the promising applications in the study of healthy and injured central nervous system. The findings obtained are generally consistent with the anatomic knowledge based on invasive methods, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.10.015

    authors: Giove F,Garreffa G,Giulietti G,Mangia S,Colonnese C,Maraviglia B

    更新日期:2004-12-01 00:00:00

  • MRI-assisted radiation therapy planning of brain tumors--clinical experiences in 17 patients.

    abstract::A new and simple method for precise determination of lateral opposed treatment portals was developed and used in 17 patients. Compared to CT, MRI led to significant changes of portals in 59% (10/17) of cases. Individual shielding blocks could be precisely designed by use of our new method. MRI is the procedure of choi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90007-9

    authors: Just M,Rösler HP,Higer HP,Kutzner J,Thelen M

    更新日期:1991-01-01 00:00:00

  • Correction of intensity nonuniformity in MR images of any orientation.

    abstract::The specialised radiofrequency (RF) coils used in MRI such as head or surface coils can give rise to marked image intensity nonuniformities. There are two situations in which it is essential to correct this: (1) When a global intensity threshold is used to segment particular tissues; and (2) in proton density images, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90023-7

    authors: Wicks DA,Barker GJ,Tofts PS

    更新日期:1993-01-01 00:00:00

  • Gadolinium toxicity: Iron and ferroportin as central targets.

    abstract::Gadolinium-based magnetic resonance (MR) contrast agents (GBCM) causes a devastating systemic fibrosing illness, nephrogenic systemic fibrosis (NSF), in patients with reduced kidney function. GBCM targets iron-recycling CD163- and ferroportin-expressing macrophages to release labile iron that mediates gadolinium toxic...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2016.08.016

    authors: Swaminathan S

    更新日期:2016-12-01 00:00:00

  • Localized high-resolution DTI of the human midbrain using single-shot EPI, parallel imaging, and outer-volume suppression at 7T.

    abstract::Localized high-resolution diffusion tensor images (DTI) from the midbrain were obtained using reduced field-of-view (rFOV) methods combined with SENSE parallel imaging and single-shot echo planar (EPI) acquisitions at 7T. This combination aimed to diminish sensitivities of DTI to motion, susceptibility variations, and...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.01.013

    authors: Wargo CJ,Gore JC

    更新日期:2013-07-01 00:00:00

  • A volume resolution phantom for MRI.

    abstract::Multisite quantitative magnetic resonance imaging (qMRI) of volume requires a small isotropic point spread-function (PSF) that is spatially, temporarily, and platform invariant. A phantom which will allow rapid assessment of this metric throughout the imaged volume without repositioning will assist certification of im...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.07.002

    authors: Moon SY,Hornak JP

    更新日期:2010-02-01 00:00:00