Controlled delivery of Gd-containing liposomes to lymph nodes: surface modification may enhance MRI contrast properties.

Abstract:

:Surface modification of liposomes containing Gd-diethylenetriaminepentaacetyl-phosphatidylethanolamine (Gd-DTPA-PE) as an amphiphilic paramagnetic label influences their contrast properties as MRI agents. Liposomes with the mean diameter ca. 220 nm and 10% mol content of Gd-DTPA-PE were modified with dextran (molecular weight 6 kDa) or polyethyleneglycol (PEG, molecular weight 5 kDa). The preparations obtained were used for MR visualization of axillary and subscapular lymph nodes after SC injection into rabbit's paw. Dextran-modified liposomes were found to have limited or no effect on lymph node/muscle MR signal intensity ratio during the first 2 h after the administration when compared to nonmodified plain liposomes, whereas the liposomes modified with PEG demonstrated a 3-3.5-fold enhancement of lymph node signal. However, the partial biodistribution studies with the 111In-labeled liposomes revealed that PEG-modified vesicles accumulated in the axillary lymph node at half the amount comparing with nonmodified and dextran-modified liposomes. The phenomenon found might be explained by noticeably increased relaxivity of PEG-modified Gd-liposomes.

journal_name

Magn Reson Imaging

authors

Trubetskoy VS,Cannillo JA,Milshtein A,Wolf GL,Torchilin VP

doi

10.1016/0730-725x(94)00083-f

subject

Has Abstract

pub_date

1995-01-01 00:00:00

pages

31-7

issue

1

eissn

0730-725X

issn

1873-5894

pii

0730725X9400083F

journal_volume

13

pub_type

杂志文章
  • Background parenchymal enhancement in the contralateral normal breast of patients undergoing neoadjuvant chemotherapy measured by DCE-MRI.

    abstract::The purpose of this study was to analyze background parenchymal enhancement (BPE) in the contralateral normal breast of cancer patients during the course of neoadjuvant chemotherapy (NAC). Forty-five subjects were analyzed. Each patient had three MRIs, one baseline (B/L) and two follow-up (F/U) studies. The fibrogland...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.014

    authors: Chen JH,Yu H,Lin M,Mehta RS,Su MY

    更新日期:2013-11-01 00:00:00

  • Correction of intensity nonuniformity in MR images of any orientation.

    abstract::The specialised radiofrequency (RF) coils used in MRI such as head or surface coils can give rise to marked image intensity nonuniformities. There are two situations in which it is essential to correct this: (1) When a global intensity threshold is used to segment particular tissues; and (2) in proton density images, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90023-7

    authors: Wicks DA,Barker GJ,Tofts PS

    更新日期:1993-01-01 00:00:00

  • 1H magnetic resonance imaging and 31P magnetic resonance spectroscopy in experimental filariasis.

    abstract::1H Magnetic resonance imaging and 31P magnetic resonance spectroscopy (MRS) have been carried out in experimental rodent filariasis, i.e., Acanthocheilonema viteae infection in the rodent host, Mastomys coucha. The T2-weighted image of the infected host shows fine hyperintense thread like structures of adult filariid ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00180-x

    authors: Shukla-Dave A,Fatma N,Roy R,Srivastava S,Chatterjee RK,Govindaraju V,Viswanathan AK,Raghunathan P

    更新日期:1997-01-01 00:00:00

  • Evaluation of preprocessing steps to compensate for magnetic field distortions due to body movements in BOLD fMRI.

    abstract::Blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) is currently the dominant technique for non-invasive investigation of brain functions. One of the challenges with BOLD fMRI, particularly at high fields, is compensation for the effects of spatiotemporally varying magnetic field inho...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.07.005

    authors: Barry RL,Williams JM,Klassen LM,Gallivan JP,Culham JC,Menon RS

    更新日期:2010-02-01 00:00:00

  • Magnetic resonance imaging appearance of metastatic Merkel cell carcinoma to the sacrum and epidural space.

    abstract::Merkel cell carcinoma (MCC) is a rare malignant tumor of the skin and often is diagnosed histologically as lymphoma, melanoma and even metastatic small cell carcinoma of the lung (SCCL). Classified as a neuroendocrine tumor, clinically it originates in the head and neck region and may present with metastatic disease a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00176-4

    authors: Moayed S,Maldjianb C,Adam R,Bonakdarpour A

    更新日期:2000-10-01 00:00:00

  • Diffusion pore imaging with generalized temporal gradient profiles.

    abstract::In porous material research, one main interest of nuclear magnetic resonance diffusion (NMR) experiments is the determination of the shape of pores. While it has been a longstanding question if this is in principle achievable, it has been shown recently that it is indeed possible to perform NMR-based diffusion pore im...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.03.027

    authors: Laun FB,Kuder TA

    更新日期:2013-09-01 00:00:00

  • Self-navigated 3D whole-heart MRA for non-enhanced surveillance of thoracic aortic dilation: A comparison to CTA.

    abstract:PURPOSE:To prospectively compare image quality and reliability of a non-contrast, self-navigated 3D whole-heart magnetic resonance angiography (MRA) sequence with contrast-enhanced computed tomography angiography (CTA) for sizing of thoracic aortic aneurysm (TAA). METHODS:Self-navigated 3D whole-heart 1.5 T MRA was pe...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.12.003

    authors: Poskaite P,Pamminger M,Kranewitter C,Kremser C,Reindl M,Reiter G,Piccini D,Dumfarth J,Henninger B,Tiller C,Holzknecht M,Reinstadler SJ,Klug G,Metzler B,Mayr A

    更新日期:2021-02-01 00:00:00

  • Susceptibility-matched envelope for the correction of EPI artifacts.

    abstract::Fast gradient echo sequences, such as echo planer imaging (EPI) and spiral imaging, are vulnerable to artifacts resulting from B(0) inhomogeneities. A major contribution to these artifacts is the susceptibility variation across the head, which is most severe in regions adjacent to air-tissue interfaces, such as the mo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.07.011

    authors: Neufeld A,Assaf Y,Graif M,Hendler T,Navon G

    更新日期:2005-11-01 00:00:00

  • T2* measurements in human brain at 1.5, 3 and 7 T.

    abstract::Measurements have been carried out in six subjects at magnetic fields of 1.5, 3 and 7 T, with the aim of characterizing the variation of T2* with field strength in human brain. Accurate measurement of T2* in the presence of macroscopic magnetic field inhomogeneity is problematic due to signal decay resulting from thro...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.02.014

    authors: Peters AM,Brookes MJ,Hoogenraad FG,Gowland PA,Francis ST,Morris PG,Bowtell R

    更新日期:2007-07-01 00:00:00

  • Water diffusion in biological porous systems: a NMR approach.

    abstract::The spin-echo nuclear magnetic resonance (NMR) technique together with paramagnetic ion doping are used to study structural parameters of plant samples, such as restricted dimensions, and cell interconnection both through membranes and by cell contact by studying simultaneous restricted diffusion and intercellular wat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00053-8

    authors: Anisimov AV,Sorokina NY,Dautova NR

    更新日期:1998-06-01 00:00:00

  • Finite element aided tracking of signal intensity changes in deforming intervertebral disc tissue.

    abstract::Tracking of signal intensity changes in soft tissue over time is often hampered by deformation of the tissue. In this study a method is described that uses finite element modeling to compensate for tissue deformation. The method is applied to the quantification of fluid redistribution in an intervertebral disc that de...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00251-8

    authors: Kingma I,Weinans H,van Dieën JH,de Boer RW

    更新日期:1998-01-01 00:00:00

  • Ultrashort echo (UTE) versus pointwise encoding time reduction with radial acquisition (PETRA) sequences at 3 Tesla for knee meniscus: A comparative study.

    abstract:PURPOSE:The purposes of this study were to (1) correlate the ultrashort echo time (TE) signal intensity of the pointwise encoding time reduction with radial acquisition (PETRA) sequence with that of the ultrashort echo (UTE) sequence using in vivo meniscal ultrashort TE imaging of the knee with a 3-Tesla (3T) clinical ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.09.003

    authors: Lee YH,Suh JS,Grodzki D

    更新日期:2016-02-01 00:00:00

  • Analyzing spatially and temporally visualized formation behavior of methane hydrate in unconsolidated porous media.

    abstract::An understanding of the nucleation and growth mechanism of methane hydrate in porous space is essential for exploitation and application of hydrates, but the mechanism is yet to be clarified. Magnetic resonance imaging (MRI) was employed to visually analyze the spatial and temporal formation behavior of methane hydrat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.06.005

    authors: Zhang L,Sun L,Sun M,Lv X,Dong H,Miao Y,Yang L,Song Y,Zhao J

    更新日期:2019-09-01 00:00:00

  • Nuclear magnetic resonance imaging techniques as developed modestly within a university medical center environment: what can the small system contribute at this point?

    abstract::This paper describes a geometrically small NMR imaging system which has been developed and assembled within a university medical center environment. Consideration is given to the technical specifications and basic economics for the magnet system, NMR spectrometer, and computer configuration. Initial research objective...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(82)90268-5

    authors: Thomas SR,Ackerman JL,Goebel JR,Davis M,Kereiakes JG,Lin YY

    更新日期:1982-01-01 00:00:00

  • Diffusion tensor imaging of native and degenerated human articular cartilage.

    abstract::Diffusion tensor imaging (DTI) is potentially sensitive to collagen degeneration in cartilage. In this study, DTI was measured on human cartilage samples with interventions of trypsin and collagenase. The measured preferred diffusion direction was consistent with the zonal structure of collagen network. The glycosamin...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.10.015

    authors: Deng X,Farley M,Nieminen MT,Gray M,Burstein D

    更新日期:2007-02-01 00:00:00

  • Arterial input functions (AIFs) measured directly from arteries with low and standard doses of contrast agent, and AIFs derived from reference tissues.

    abstract::Measurements of arterial input function (AIF) can have large systematic errors at standard contrast agent doses in dynamic contrast enhanced MRI (DCE-MRI). We compared measured AIFs from low dose (AIFLD) and standard dose (AIFSD) contrast agent injections, as well as the AIF derived from a muscle reference tissue and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.10.025

    authors: Wang S,Fan X,Medved M,Pineda FD,Yousuf A,Oto A,Karczmar GS

    更新日期:2016-02-01 00:00:00

  • Quantitative magnetic resonance imaging of 'Fuyu' persimmon fruit during development and ripening.

    abstract::Qualitative and quantitative proton magnetic resonance imaging techniques were applied to persimmon (Diospyros kaki cv 'Fuyu') fruit during development and post-harvest ripening. Spin-lattice (T(1)) relaxation times in mesocarp parenchyma and vascular tissue exhibited a sigmoidal pattern of increase leading to commerc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00082-1

    authors: Clark CJ,MacFall JS

    更新日期:2003-07-01 00:00:00

  • Parallel imaging for first-pass myocardial perfusion.

    abstract::Two parallel imaging methods used for first-pass myocardial perfusion imaging were compared in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image artifacts. One used adaptive Time-adaptive SENSitivity Encoding (TSENSE) and the other used GeneRalized Autocalibrating Partially Parallel Acquisi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.10.012

    authors: Irwan R,Lubbers DD,van der Vleuten PA,Kappert P,Götte MJ,Sijens PE

    更新日期:2007-06-01 00:00:00

  • In vivo animal tests of an artifact-free contrast agent for gastrointestinal MRI.

    abstract::A variety of shortcomings are associated with most currently used gastrointestinal contrast agents for magnetic resonance imaging (MRI). Artifacts resulting from peristalsis and other motions in the abdominal region are produced by many positive contrast agents (which increase signal intensity). Although this is not a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00020-9

    authors: Briggs RW,Wu Z,Mladinich CR,Stoupis C,Gauger J,Liebig T,Ros PR,Ballinger JR,Kubilis P

    更新日期:1997-01-01 00:00:00

  • 23Na magnetic resonance imaging: distribution of brine in muscle.

    abstract::Magnetic resonance imaging (MRI) has been used to characterize tissues in morphological studies. Here, 23Na NMR imaging was used to study the distribution in muscle of brine (5 M NaCl), injected before onset of rigor mortis. First, the distribution of brine was monitored in excised muscle from rabbits for 6 hr followi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92360-4

    authors: Renou JP,Benderbous S,Bielicki G,Foucat L,Donnat JP

    更新日期:1994-01-01 00:00:00

  • Determination of blood circulation times of superparamagnetic iron oxide nanoparticles by T2* relaxometry using ultrashort echo time (UTE) MRI.

    abstract::Blood circulation is an important determinant of the biodistribution of superparamagnetic iron oxide nanoparticles. Here we present a magnetic resonance imaging (MRI) technique based on the use of ultrafast echo times (UTE) for the noninvasive determination of blood half-lives at high particle concentrations, when con...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.06.017

    authors: Scharlach C,Warmuth C,Schellenberger E

    更新日期:2015-11-01 00:00:00

  • Acute effects of exercise on muscle MRI in peripheral arterial occlusive disease.

    abstract::The midcalf muscles of eight patients who had peripheral arterial occlusive disease were evaluated by exercise MRI before and after bypass surgery or percutaneous transluminal angioplasty. MRI showed a high intensity of these muscles, especially the posterior muscles, after exercise in all patients before intervention...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00018-c

    authors: Yoshioka H,Anno I,Kuramoto K,Matsumoto K,Jikuya T,Itai Y

    更新日期:1995-01-01 00:00:00

  • Diagnosis of discoid lateral meniscus of the knee on MR imaging.

    abstract::To establish the quantitative MR diagnostic criteria for discoid lateral meniscus, MR imaging of 60 knees with arthroscopically confirmed discoid lateral menisci and 134 knees with semilunar lateral menisci were analyzed. Following four quantitative parameters were measured. (1) Meniscal width (MW): The minimum menisc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00473-3

    authors: Samoto N,Kozuma M,Tokuhisa T,Kobayashi K

    更新日期:2002-01-01 00:00:00

  • MRI inter-slice reconstruction using super-resolution.

    abstract::MRI reconstruction using super-resolution is presented and shown to improve spatial resolution in cases when spatially-selective RF pulses are used for localization. In 2-D multislice MRI, the resolution in the slice direction is often lower than the in-plane resolution. For certain diagnostic imaging applications, is...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00511-8

    authors: Greenspan H,Oz G,Kiryati N,Peled S

    更新日期:2002-06-01 00:00:00

  • Pulseq-Graphical Programming Interface: Open source visual environment for prototyping pulse sequences and integrated magnetic resonance imaging algorithm development.

    abstract:PURPOSE:To provide a single open-source platform for comprehensive MR algorithm development inclusive of simulations, pulse sequence design and deployment, reconstruction, and image analysis. METHODS:We integrated the "Pulseq" platform for vendor-independent pulse programming with Graphical Programming Interface (GPI)...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.03.008

    authors: Ravi KS,Potdar S,Poojar P,Reddy AK,Kroboth S,Nielsen JF,Zaitsev M,Venkatesan R,Geethanath S

    更新日期:2018-10-01 00:00:00

  • Biodegradable cystamine spacer facilitates the clearance of Gd(III) chelates in poly(glutamic acid) Gd-DO3A conjugates for contrast-enhanced MR imaging.

    abstract::Poly(L-glutamic acid) (PGA)-cystamine-[gadolinium (Gd)-DO3A] was prepared in high yield with a high Gd-DO3A conjugation efficiency. Approximately 55% of the carboxylic groups in PGA were loaded with Gd-DO3A via cystamine as the spacer. Cystamine can be readily cleaved by endogenous thiols to release the Gd(III) chelat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.03.009

    authors: Ke T,Feng Y,Guo J,Parker DL,Lu ZR

    更新日期:2006-09-01 00:00:00

  • Mri measurements of T1, T2 and D for gels undergoing volume phase transition.

    abstract::Gels consist of crosslinked polymer network swollen in solvent. The network of flexible long-chain molecules traps the liquid medium they are immersed in. Some gels undergo abrupt volume change, a phase transition process, by swelling-shrinking in response to external stimuli changes in solvent composition, temperatur...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00639-2

    authors: Yung KT

    更新日期:2003-02-01 00:00:00

  • Dynamic contrast-enhanced 3D breath hold MRA using a multiple variable orientation slab acquisition.

    abstract::With the conventional 3D MR angiographic sequences, it is difficult to prescribe multiple phases in different orientations, though multiple phases may be prescribed in the same orientation as the initial scan. Magnetic resonance angiography (MRA) was performed in which three slabs were prescribed in different orientat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00003-x

    authors: Shetty AN,Bis KG

    更新日期:1999-07-01 00:00:00

  • Lee-Goldburg solid-state imaging.

    abstract::A new approach to solid-state imaging (SSI) is presented. The method relies on narrowing the resonance line using the Lee-Goldburg sequence. The technique is easy to implement in practice and may find widespread applications in materials science. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90409-s

    authors: De Luca F,Lugeri N,De Simone BC,Maraviglia B

    更新日期:1992-01-01 00:00:00

  • Breath-hold T2-weighted sequences of the liver: a comparison of four techniques at 1.0 and 1.5 T.

    abstract::T2-weighted images are considered the most sensitive for lesion detection at high field; however, long imaging time is problematic. Accordingly, the authors compared four breath-hold T2 or T2* weighted sequences comprising T2*-weighted FLASH, T2*-weighted PSIF, T2-weighted rapid spin echo (RASE), and T2-weighted Turbo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90371-6

    authors: Simm FC,Semelka RC,Recht M,Deimling M,Lenz G,Laub GA

    更新日期:1992-01-01 00:00:00