An alternative viewpoint of the similarities and differences of SVD and FT deconvolution algorithms used for quantitative MR perfusion studies.

Abstract:

:Quantitative cerebral blood flow (CBF) values can be determined from residue function estimates obtained from magnetic resonance dynamic susceptibility contrast (DSC) perfusion studies using a variety of deconvolution approaches. However, there are significant differences between the CBF estimates obtained, differences that are not simply due to minor details of the implementation of the algorithms. The standard singular value decomposition (sSVD) shows a variation of CBF values with arterial-tissue delay (ATD) not present with the Fourier transform deconvolution algorithm. Fourier transform deconvolution and the newly suggested delay-invariant SVD algorithm implementations provide CBF estimates whose accuracy changes with tissue mean transit times (MTTs). Techniques combining sSVD with deliberate ATD manipulation have been proposed to compensate for this inaccuracy. Other studies indicate that CBF changes related to slice position in a multislice study, and other experimental factors, can be reduced using interpolative deconvolution algorithms. In this review, we use both time-domain and frequency-domain analysis to show the underlying theoretical relationships between these many approaches to obtain "the best" CBF estimate. This model allows us to better understand the similarities and differences, advantages and disadvantages between these variants of the deconvolution algorithms used in DSC perfusion studies.

journal_name

Magn Reson Imaging

authors

Salluzzi M,Frayne R,Smith MR

doi

10.1016/j.mri.2004.12.001

subject

Has Abstract

pub_date

2005-04-01 00:00:00

pages

481-92

issue

3

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(05)00002-0

journal_volume

23

pub_type

杂志文章
  • Synthesis of magnetic gradients for NMR tomography.

    abstract::A numerical method is applied to calculate an optimal distribution of currents in air which generate the magnetic field gradients required to spatially encode the radiofrequency signal in a NMR tomographic experiment. We compare the performances of the gradient circuits for the whole body air-core electromagnet descri...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90242-t

    authors: Mustarelli P,Rudnicki M,Savini A,Savoldi F,Villa M

    更新日期:1990-01-01 00:00:00

  • Functional magnetic resonance cholangiography with Gd-EOB-DTPA: a study in healthy volunteers.

    abstract:PURPOSE:To describe the patterns of bile distribution in the biliary tree, duodenum, jejunum, and stomach, and to determine the gallbladder ejection fraction (GBEF) by using functional magnetic resonance cholangiography (MRC) with gadolinium-ethoxybenzyl-diethylenetriamine penta-acetic acid (Gd-EOB-DTPA) in healthy vol...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.mri.2014.01.003

    authors: Lee SW,Cha SH,Chung HH,Kim KH,Yeom SK,Seo BK,Je BK,Kim BH

    更新日期:2014-05-01 00:00:00

  • 4D MR phase and magnitude segmentations with GPU parallel computing.

    abstract::The increasing size and number of data sets of large four dimensional (three spatial, one temporal) magnetic resonance (MR) cardiac images necessitates efficient segmentation algorithms. Analysis of phase-contrast MR images yields cardiac flow information which can be manipulated to produce accurate segmentations of t...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.019

    authors: Bergen RV,Lin HY,Alexander ME,Bidinosti CP

    更新日期:2015-01-01 00:00:00

  • Balanced multi-image demons for non-rigid registration of magnetic resonance images.

    abstract::A new approach is introduced for non-rigid registration of a pair of magnetic resonance images (MRI). It is a generalization of the demons algorithm with low computational cost, based on local information augmentation (by integrating multiple images) and balanced implementation. Specifically, a single deformation that...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.09.013

    authors: Mesin L

    更新日期:2020-12-01 00:00:00

  • Issues about the fMRI of the human spinal cord.

    abstract::Noninvasive functional studies on human spinal cord by means of magnetic resonance imaging (MRI) are gaining attention because of the promising applications in the study of healthy and injured central nervous system. The findings obtained are generally consistent with the anatomic knowledge based on invasive methods, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.10.015

    authors: Giove F,Garreffa G,Giulietti G,Mangia S,Colonnese C,Maraviglia B

    更新日期:2004-12-01 00:00:00

  • "Molecular" MR imaging at high fields.

    abstract::Magnetic resonance imaging (MRI) and spectroscopy (MRS) have contributed considerably to clinical radiology, and a variety of MR techniques have been developed to evaluate pathological processes as well as normal tissue biology at the cellular and molecular level. However, in comparison to nuclear imaging, MRI has rel...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.12.008

    authors: Gore JC,Zu Z,Wang P,Li H,Xu J,Dortch R,Gochberg DF

    更新日期:2017-05-01 00:00:00

  • Dual-echo breathhold T(2)-weighted fast spin echo MR imaging of liver lesions.

    abstract::The purpose of this study was to develop a multi-shot dual-echo breathhold fast spin echo technique (DFSE) and compare it with conventional spin echo (T2SE) for T(2)-weighted MR imaging of liver lesions. The DFSE acquisition (EffTE1/EffTE2/TR = 66/143/2100 ms) imaged 5 sections per 17 s breathhold. T2SE imaging (TE1/T...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00120-4

    authors: Rydberg JN,Tervonen OA,Rydberg DB,Lomas DJ,Ehman RL,Riederer SJ

    更新日期:2000-02-01 00:00:00

  • The diagnosis of hippocampal sclerosis: other techniques.

    abstract::Pathologically, hippocampal sclerosis (HS) is characterized by neuronal loss and gliosis affecting particularly the pyramidal neurons of CA1, CA3, and CA4 with relative sparing of the CA2 neurons. This can be identified in vivo with magnetic resonance (MR) imaging techniques that can reveal both morphological and sign...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(95)02016-m

    authors: Jackson GD

    更新日期:1995-01-01 00:00:00

  • A quantitative study of water proton relaxation in packed beds of porous particles with varying water content.

    abstract::A quantitative analysis of the dependence of water proton relaxation on water content in randomly packed beds of Sephadex is undertaken. A combination of Osmotic and Capillary theory is used to describe the morphological changes occurring in the packed beds as the water content is lowered. At each water content the wa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92032-x

    authors: Hills BP,Babonneau F

    更新日期:1994-01-01 00:00:00

  • Determination of blood circulation times of superparamagnetic iron oxide nanoparticles by T2* relaxometry using ultrashort echo time (UTE) MRI.

    abstract::Blood circulation is an important determinant of the biodistribution of superparamagnetic iron oxide nanoparticles. Here we present a magnetic resonance imaging (MRI) technique based on the use of ultrafast echo times (UTE) for the noninvasive determination of blood half-lives at high particle concentrations, when con...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.06.017

    authors: Scharlach C,Warmuth C,Schellenberger E

    更新日期:2015-11-01 00:00:00

  • High resolution simultaneous imaging of intracranial and extracranial arterial wall with improved cerebrospinal fluid suppression.

    abstract:PURPOSE:To develop a technique for three dimensional (3D) high resolution joint imaging of intracranial and extracranial arterial walls with improved cerebrospinal fluid (CSF) suppression and good blood suppression based on T1 weighted sampling perfection with application optimized contrast using different angle evolut...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.08.004

    authors: Zhang L,Zhang N,Wu J,Liu X,Chung YC

    更新日期:2017-12-01 00:00:00

  • A fast spin echo two-point Dixon technique and its combination with sensitivity encoding for efficient T2-weighted imaging.

    abstract::A fast spin echo two-point Dixon (fast 2PD) technique was developed for efficient T2-weighted imaging with uniform water and fat separation. The technique acquires two interleaved fast spin echo images with water and fat in-phase and 180 degrees out-of-phase, respectively, and generates automatically separate water an...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.005

    authors: Ma J,Son JB,Bankson JA,Stafford RJ,Choi H,Ragan D

    更新日期:2005-12-01 00:00:00

  • MR imaging of pterygoid muscle inflammation.

    abstract::A case report of trismus after a dental procedure is evaluated by MR imaging. The medial and lateral pterygoid muscles showed inflammatory changes. Etiologies of trismus are reviewed. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90148-u

    authors: Ciacchella AP,Higgins WL

    更新日期:1990-01-01 00:00:00

  • Sampling time effects on signal-to-noise and contrast-to-noise ratios in spin-echo MRI.

    abstract::This work discusses the effect of sampling time on noise, signal-to-noise and contrast-to-noise ratios in magnetic resonance imaging. A simple imaging experiment is performed to demonstrate the effect of sampling time on noise, confirming theoretical expectations that doubling the sampling time while decreasing the re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90481-4

    authors: Hendrick RE

    更新日期:1987-01-01 00:00:00

  • Quantitative assessment of rat kidney function by measuring the clearance of the contrast agent Gd(DOTA) using dynamic MRI.

    abstract::Magnetic resonance imaging (MRI) has been applied to assess kidney function in normal rats by monitoring the passage of the extracellular contrast agent GdDOTA. High-resolution images have been obtained using either the rapid acquisition with relaxation enhancement (RARE) or the snapshot pulse sequence. The latter was...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00134-x

    authors: Baumann D,Rudin M

    更新日期:2000-06-01 00:00:00

  • Magnetic resonance imaging of female pelvic masses and local recurrent tumors at an ultra low (0.02 T) magnetic field: correlation with computed tomography.

    abstract::Pelvic MR (41 patients) and CT (36 patients) examinations were performed on 14 females with a primary pelvic complaint, and on 28 females with a suspicion of local recurrent disease of gynecologic malignant tumor. Benign cystic tumors were found in eight patients, five patients had endometriomas, one had a lymphoma, a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90409-7

    authors: Varpula M

    更新日期:1993-01-01 00:00:00

  • MRI appearance of disseminated osseous tuberculosis.

    abstract::Disseminated osseous tuberculosis is a rare disease. This is a report of two cases of disseminated osseous tuberculosis imaged with MRI at 1.5-T, CT, plain radiography and bone scintigraphy. CT and plain radiography demonstrated either highly destructive or cystic lesions with sclerotic margins. Bone scintigraphy and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90384-5

    authors: Quinn SF,Murray W,Prochaska J,Cochran C,Clark R

    更新日期:1987-01-01 00:00:00

  • The Elgin marvel: using magnetic resonance imaging to look at a moldic fossil from the Permian of Elgin, Scotland, UK.

    abstract::The successful use of magnetic resonance imaging (MRI) of a moldic fossil dicynodont from the Permian aeolian Hopeman Sandstone Formation of Elgin, Scotland, UK, provides paleontologists with a nondestructive technique for examining fossils preserved in this fashion. For large moldic fossils, medical scanners such as ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.09.006

    authors: Clark ND,Adams C,Lawton T,Cruickshank AR,Woods K

    更新日期:2004-02-01 00:00:00

  • Improved optimization strategies for autofocusing motion compensation in MRI via the analysis of image metric maps.

    abstract::Autofocusing is a postprocessing technique for motion correction, which optimizes an image quality metric against various trial motions. In this work, image metric maps, which are measures of image quality plotted as a function of in-plane 2-D trial translations, are systematically studied to develop improved autofocu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.02.003

    authors: Lin W,Song HK

    更新日期:2006-07-01 00:00:00

  • Biodistribution of GdCl3 and Gd-DTPA and their influence on proton magnetic relaxation in rat tissues.

    abstract::The biodistribution and relative molar effectiveness of the ionic (GdCl3) and chelated (Gd-DTPA) forms of gadolinium (Gd) to enhance proton relaxation rates in rat kidney, liver and spleen were evaluated. Rats were given intravenous injections of either GdCl3 (100 mumol/kg) or Gd-DTPA (178 mumol/kg). Gd-DTPA was prima...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90023-3

    authors: Barnhart JL,Kuhnert N,Bakan DA,Berk RN

    更新日期:1987-01-01 00:00:00

  • Diagnosis of suspicious breast lesions using an empirical mathematical model for dynamic contrast-enhanced MRI.

    abstract::The purpose of this study was to test whether an empirical mathematical model (EMM) of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can distinguish between benign and malignant breast lesions. A modified clinical protocol was used to improve the sampling of contrast medium uptake and washout. T(1)-we...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.10.011

    authors: Fan X,Medved M,Karczmar GS,Yang C,Foxley S,Arkani S,Recant W,Zamora MA,Abe H,Newstead GM

    更新日期:2007-06-01 00:00:00

  • MRI-guided breast vacuum biopsy: Localization of the lesion without contrast-agent application using diffusion-weighted imaging.

    abstract:OBJECTIVE:In magnetic resonance-guided breast vacuum biopsies, the contrast agent for targeting suspicious lesions can typically be applied only once during an intervention, due to the slow elimination of the gadolinium chelate from the extracellular fluid space. This study evaluated the feasibility of diffusion-weight...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.12.006

    authors: Berger N,Varga Z,Frauenfelder T,Boss A

    更新日期:2017-05-01 00:00:00

  • The uptake of Mn-DPDP by hepatocytes is not mediated by the facilitated transport of pyridoxine.

    abstract::Manganese-dipyridoxal diphosphate (Mn-DPDP) is a liver-selective contrast agent selectively taken up by the hepatocytes. Because of the analogy of structure with pyridoxine (vitamin B6), it was previously suggested that this compound can be selectively taken up by the facilitated transport of vitamers B6. To understan...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00140-3

    authors: Gallez B,Baudelet C,Adline J,Charbon V,Lambert DM

    更新日期:1996-01-01 00:00:00

  • Diffusion-weighted imaging in epilepsy.

    abstract::Diffusion-weighted imaging (DWI) is a relatively new magnetic resonance imaging (MRI) technique that can be used to probe the microenvironment of water. Contrast in DWI depends on properties different from traditional T1 and T2 contrast, and is derived form the translational motion of water molecules. Since it is reas...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(95)02036-s

    authors: Helpern JA,Huang N

    更新日期:1995-01-01 00:00:00

  • Velocity distribution of slow fluid flows in Bentheimer sandstone: an NMRI and propagator study.

    abstract::This work addresses the special problems of measuring flow velocity distributions in rock by NMR methods. Specifically, these problems are to measure very slow flows as well as flows in the presence of background magnetic field gradients caused by heterogeneities of the rock. We modify a stimulated echo sequence for u...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00110-5

    authors: Waggoner RA,Fukushima E

    更新日期:1996-01-01 00:00:00

  • Analysis of microporosity and setting of reactive powder concrete by proton nuclear relaxation.

    abstract::The proton spin-lattice relaxation measured at several frequencies leads to a resolved distribution of four Tli for reactive powder concrete (RPC). The typical Tli frequency dependences are quantitatively interpreted by a biphasic fast exchange model and a proton nuclear relaxation of hydrated paramagnetic ions at the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00063-0

    authors: Philippot S,Korb JP,Petit D,Zanni H

    更新日期:1998-06-01 00:00:00

  • Oxygen-sensitive 19F NMR imaging of the vascular system in vivo.

    abstract::The fluorine nuclear magnetic resonance spin-lattice relaxation rate (1/T1) of the perfluorochemical blood substitute perfluorotripropylamine (FTPA) is very sensitive to oxygen tension. This presents the possibility of measuring blood oxygen tension by 19F MR imaging. We obtained oxygen-sensitive 19F NMR images of the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90005-1

    authors: Fishman JE,Joseph PM,Floyd TF,Mukherji B,Sloviter HA

    更新日期:1987-01-01 00:00:00

  • Off-resonance frequency filtered magnetic resonance imaging.

    abstract::One of the main problems with rapid magnetic resonance imaging (MRI) techniques is the artifacts that result from off-resonance effects. The proposed off-resonance frequency filtered MRI (OFF-MRI) method focuses on the elimination of off-resonance components from the image of the observed object. To maintain imaging s...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.12.027

    authors: Medic J,Tomazic S

    更新日期:2010-05-01 00:00:00

  • An intravascular loopless monopole antenna for vessel wall MR imaging at 3.0 T.

    abstract::The purpose of this study was to develop a novel intravascular loopless monopole antenna (ILMA) design specifically for imaging of small vessel walls. The ILMA consisted of an unshielded, low-friction guide wire and a tuning/matching box. The material of the guide wire was nitinol and it was coated with polyurethane. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.032

    authors: Yuan H,Lv X,Ma X,Zhang R,Fu Y,Yang X,Wang X,Zhang Z,Zhang J,Fang J

    更新日期:2013-01-01 00:00:00

  • A volume resolution phantom for MRI.

    abstract::Multisite quantitative magnetic resonance imaging (qMRI) of volume requires a small isotropic point spread-function (PSF) that is spatially, temporarily, and platform invariant. A phantom which will allow rapid assessment of this metric throughout the imaged volume without repositioning will assist certification of im...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.07.002

    authors: Moon SY,Hornak JP

    更新日期:2010-02-01 00:00:00