Subharmonic contrast microbubble signals for noninvasive pressure estimation under static and dynamic flow conditions.

Abstract:

:Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled confocally at a 60 degree angle to each other. Changes in the first, second and subharmonic amplitudes of five different ultrasound contrast agents were measured in vitro at static hydrostatic pressures from 0-186 mmHg, acoustic pressures from 0.35-0.60 MPa peak-to-peak and frequencies of 2.5-6.6 MHz. The most sensitive agent and optimal parameters for SHAPE were determined using linear regression analysis and implemented on a Logiq 9 scanner (GE Healthcare, Milwaukee, WI). This implementation of SHAPE was then tested under dynamic-flow conditions and compared to pressure-catheter measurements. Over the pressure range studied, the first and second harmonic amplitudes reduced approximately 2 dB for all contrast agents. Over the same pressure range, the subharmonic amplitudes decreased by 9-14 dB and excellent linear regressions were achieved with the hydrostatic pressure variations (r = 0.98, p < 0.001). Optimal sensitivity was achieved at a transmit frequency of 2.5 MHz and acoustic pressure of 0.35 MPa using Sonazoid (GE Healthcare, Oslo, Norway). A Logiq 9 scanner was modified to implement SHAPE on a convex transducer with a frequency range from 1.5-4.5 MHz and acoustic pressures from 0-3.34 MPa. Results matched the pressure catheter (r2 = 0.87). In conclusion, subharmonic contrast signals are a good indicator of hydrostatic pressure. Out of the five ultrasound contrast agents tested, Sonazoid was the most sensitive for subharmonic pressure estimation. Real-time SHAPE has been implemented on a commercial scanner and offers the possibility of allowing pressures in the heart and elsewhere to be obtained noninvasively.

journal_name

Ultrason Imaging

journal_title

Ultrasonic imaging

authors

Halldorsdottir VG,Dave JK,Leodore LM,Eisenbrey JR,Park S,Hall AL,Thomenius K,Forsberg F

doi

10.1177/016173461103300301

subject

Has Abstract

pub_date

2011-07-01 00:00:00

pages

153-64

issue

3

eissn

0161-7346

issn

1096-0910

journal_volume

33

pub_type

杂志文章
  • Adaptive texture feature extraction with application to ultrasonic image analysis.

    abstract::Computer texture analysis methods use texture features that are traditionally chosen from a large set of fixed features known in literature. These fixed features are often not specifically designed to the problem at hand, and as a result they may have low discriminative power, and/or may be correlated. Increasing the ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章,评审

    doi:10.1177/016173469802000204

    authors: Huisman HJ,Thijssen JM

    更新日期:1998-04-01 00:00:00

  • Adaptive imaging using an optimal receive aperture size.

    abstract::Sidelobe contribution from off-axis targets degrades image quality in a coherent array imaging system. In ultrasound imaging, focusing errors resulting from sound-velocity inhomogeneities in human tissue--also known as phase aberrations reduce the coherence of the received signals and elevate the sidelobe level. This ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460502700205

    authors: Li ML,Huang SW,Ustüner K,Li PC

    更新日期:2005-04-01 00:00:00

  • Breast tissue classification using diagnostic ultrasound and pattern recognition techniques: II. Experimental results.

    abstract::The methods of statistical pattern recognition have been applied to the problem of in vivo ultrasonic characterization of breast disease in humans. Backscattered A-mode signals obtained from a commercial pulse imaging system were used to generate a large set of potentially useful features. Using statistical tests, a s...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468300500107

    authors: Finette S,Bleier AR,Swindell W,Haber K

    更新日期:1983-01-01 00:00:00

  • Acoustic Structure Quantification Analysis of the Thyroid in Patients with Diffuse Autoimmune Thyroid Disease.

    abstract::The aim of this study was to assess whether acoustic structure quantification (ASQ) can differentiate normal from pathological thyroid parenchyma in patients with diffuse autoimmune thyroid disease (AITD). We evaluated 83 subjects (72 [87%] women and 11 [13%] men) aged 19 to 94 years with a mean age of 53 years. We pe...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615580766

    authors: Zandieh S,Bernt R,Zwerina J,Haller J,Knoll P,Seyeddain O,Mirzaei S

    更新日期:2016-03-01 00:00:00

  • Ultrasound attenuation measurements of the liver in vivo using a commercial sector scanner.

    abstract::Attenuation measurements of various tissue mimicking phantoms and three different groups of patients were obtained using a modified commercial sector scanner. Estimates of attenuation were made using the spectral shift method with mean frequencies at different depths of a region of interest being obtained by both zero...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468400600402

    authors: Garra BS,Shawker TH,Nassi M,Russell MA

    更新日期:1984-10-01 00:00:00

  • A Variance-reduction Approach to Detection of the Thyroid-nodule Boundary on Ultrasound Images.

    abstract::To perform computer-aided diagnosis of the thyroid nodules on ultrasound images, the location and boundary of nodules should be clearly defined. However, the identification of thyroid nodule boundary is a difficult issue due to the biological characteristics of the nodules, the physics and quality of ultrasound imagin...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734619839648

    authors: Chiu LY,Chen A

    更新日期:2019-07-01 00:00:00

  • Statistical relationship between ultrasound echo envelope and envelope peak.

    abstract::This study shows that the amplitude information of ultrasound echoes is carried mainly by the envelope peaks (EPs). It is first shown that the EPs in an A-line represent the maximum number of independent amplitude data. It is then demonstrated that the entire envelope could be approximately reconstructed from the EPs....

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468801000403

    authors: He P

    更新日期:1988-10-01 00:00:00

  • Ultrasonic tomography of biological tissue.

    abstract::In this paper, quantitative tomographic reconstructions of biological tissue are presented. First, the experimental setup and a hybrid filtered backpropagation (FBP) technique are briefly described. Using this technique, which includes exact backpropagation of data prior to reconstruction by means of the classical FBP...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469401600102

    authors: Sponheim N,Gelius LJ,Johansen I,Stamnes JJ

    更新日期:1994-01-01 00:00:00

  • Effective scatterer diameter estimates for broad scatterer size distributions.

    abstract::Acoustic form factors have been used to model the frequency dependence of acoustic scattering in phantoms and tissues. This work demonstrates that a broad range of scatterer sizes, individually well represented by Faran theory or a Gaussian form factor, is not accurately described by a single effective scatterer from ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734614534399

    authors: Nordberg EP,Hall TJ

    更新日期:2015-01-01 00:00:00

  • Phase-derivative imaging. II: Effects of beam diffraction and scatterer density.

    abstract::The potential of using the phase derivative (PD) of the radio-frequency echograms for producing 2-dimensional grey scale images was further investigated. The PD images were produced by five different algorithms, which according to the results described in the companion paper yield PD images dominated by the amplitude ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468901100301

    authors: Oosterveld BJ,Romijn RL,Thijssen JM

    更新日期:1989-07-01 00:00:00

  • In vivo study of online liver tissue classification based on envelope power spectrum analysis.

    abstract::An ultrasonic imaging and signal analysis system, combining a 3.5 MHz linear array B-scanner and an array processor, has been realized for a clinical liver tissue classification study. Based on the complete unprocessed rf data set of a real time B-image, local envelope power spectra averaged over interactively defined...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469401600202

    authors: Lang M,Ermert H,Heuser L

    更新日期:1994-04-01 00:00:00

  • Shielding of piezoelectric ultrasonic probes in Hall effect imaging.

    abstract::This paper addresses significant sources of electromagnetic noise in Hall effect imaging. Hall effect imaging employs large electrical pulses for signal generation and high sensitivity ultrasonic probes for signal reception. Coherent noise arises through various coupling mechanisms between the excitation pulse and the...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469802000305

    authors: Wen H,Bennett E,Wiesler DG

    更新日期:1998-07-01 00:00:00

  • Improved Fourier-transform-based parallel receive beam formation.

    abstract::A Fourier transform (FT)-based technique for forming parallel receive beams has been previously employed to increase the imaging frame rate in ultrasonic imaging. However, the image quality in FT-based parallel reconstruction is degraded because differences in range focusing delays are ignored and a wide transmit beam...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460302500201

    authors: Li ML,Li PC

    更新日期:2003-04-01 00:00:00

  • Ultrasonographic Multimodality Diagnostic Model of Thyroid Nodules.

    abstract::The aim of this study was to identify independent risk factors for thyroid cancer, establish an ultrasonographic multimodality diagnostic model for thyroid nodules, and explore the diagnostic value of the model. From November 2011 to February 2015, 307 patients with a total of 367 thyroid nodules underwent conventiona...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734618815070

    authors: Zhao RN,Zhang B,Jiang YX,Yang X,Lai XJ,Zhu SL,Zhang XY

    更新日期:2019-03-01 00:00:00

  • On the feasibility of imaging peripheral nerves using acoustic radiation force impulse imaging.

    abstract::Regional anesthesia is preferred over general anesthesia for many surgical procedures; however, challenges associated with poor image guidance limit its widespread acceptance as a viable alternative. In B-mode ultrasound images, the current standard for guidance, nerves can be difficult to visualize due to their simil...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460903100303

    authors: Palmeri ML,Dahl JJ,MacLeod DB,Grant SA,Nightingale KR

    更新日期:2009-07-01 00:00:00

  • Breast-lesion Segmentation Combining B-Mode and Elastography Ultrasound.

    abstract::Breast ultrasound (BUS) imaging has become a crucial modality, especially for providing a complementary view when other modalities (i.e., mammography) are not conclusive in the task of assessing lesions. The specificity in cancer detection using BUS imaging is low. These false-positive findings often lead to an increa...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615589287

    authors: Pons G,Martí J,Martí R,Ganau S,Noble JA

    更新日期:2016-05-01 00:00:00

  • Toward Noninvasive Mapping of Diffuse Scattering in the Presence of Motion.

    abstract::Ultrasonic coda wave analysis techniques localize defects in fields such as seismography and nondestructive testing. In medical ultrasound, these techniques might provide novel mapping of tissue properties in diseases characterized by local fibrosis. In this work, we present an approach for localizing variation in sca...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734619899885

    authors: Lindsey BD,Collins GC

    更新日期:2020-01-01 00:00:00

  • Mathematical simulation of pressure pulse propagation in biological tissues.

    abstract::The propagation of pressure pulses of arbitrary time form in inhomogeneous attenuating media with characteristics similar to real biological tissues is considered. A mathematical model using the quasi-optical approximation is developed to solve the wave equation. Such a model proves to be convenient for computer reali...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469301500106

    authors: Adrov VN,Chernomordik VV

    更新日期:1993-01-01 00:00:00

  • Neural-network-based Motion Tracking for Breast Ultrasound Strain Elastography: An Initial Assessment of Performance and Feasibility.

    abstract::Accurate tracking of tissue motion is critically important for several ultrasound elastography methods. In this study, we investigate the feasibility of using three published convolution neural network (CNN) models built for optical flow (hereafter referred to as CNN-based tracking) by the computer vision community fo...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734620902527

    authors: Peng B,Xian Y,Zhang Q,Jiang J

    更新日期:2020-03-01 00:00:00

  • An adaptive approach to computing the spectrum and mean frequency of Doppler signals.

    abstract::Modern ultrasound Doppler systems are facing the problem of processing increasingly shorter data sets. Spectral analysis of the strongly nonstationary Doppler signal needs to shorten the analysis window while maintaining a low variance and high resolution spectrum. Color flow imaging requires estimation of the Doppler...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469501700101

    authors: Herment A,Giovannelli JF

    更新日期:1995-01-01 00:00:00

  • Reconstructive ultrasound elasticity imaging for renal transplant diagnosis: kidney ex vivo results.

    abstract::It may be possible to diagnose and monitor scarring, inflammation and edema in transplant kidney using reconstructive ultrasound elasticity imaging. Kidney elasticity is expected to change dramatically with scar, and to a lesser degree, with acute inflammation and edema. The hypothesis that changes in kidney elasticit...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460002200303

    authors: Emelianov SY,Lubinski MA,Skovoroda AR,Erkamp RQ,Leavey SF,Wiggins RC,O'Donnell M

    更新日期:2000-07-01 00:00:00

  • Quantitative assessment of in vivo backscatter enhancement from gelatin microspheres.

    abstract::Experimental work using a quantitative C-scan technique to measure in situ enhancement of hepatic backscatter resulting from the administration of gelatin microspheres to dogs is reported. We have found that reproducible enhancement of hepatic backscatter on the order of 2 dB followed the peripheral administration of ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468500700402

    authors: Ophir J,Gobuty A,Maklad N,Tyler T,Jaeger P,McWhirt R

    更新日期:1985-10-01 00:00:00

  • Assessment of Age-related Oxygenation Changes in Calf Skeletal Muscle by Photoacoustic Imaging: A Potential Tool for Peripheral Arterial Disease.

    abstract::Peripheral artery disease is often asymptomatic, and various imaging and nonimaging techniques have been used for assessment and monitoring treatments. This study is designed to demonstrate the ability of photoacoustic imaging to noninvasively determine changes in tissue oxygenation that occur in mice's hind limb skel...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734619862287

    authors: Kirkham BM,Schultz SM,Ashi K,Sehgal CM

    更新日期:2019-09-01 00:00:00

  • Attenuation and backscatter estimation using video signal analysis applied to B-mode images.

    abstract::Most methods for in vivo quantitation of ultrasound attenuation and backscatter are not available clinically because they rely upon acquiring and analyzing radio frequency (rf) echo signals. This paper describes a technique to estimate ultrasound attenuation and backscatter from B-mode image data. The video signal ana...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469701900305

    authors: Knipp BS,Zagzebski JA,Wilson TA,Dong F,Madsen EL

    更新日期:1997-07-01 00:00:00

  • Effects of transmit focusing on finite amplitude distortion based second harmonic generation.

    abstract::Generation of the second harmonic signal was studied for finite amplitude distortion based harmonic imaging. Acoustic field amplitudes along the range axis of a fixed focus transducer were measured using a PVDF needle hydrophone. Results indicated that on-axis amplitudes strongly depended on the f-number at both the f...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469902100401

    authors: Li PC,Shen CC

    更新日期:1999-10-01 00:00:00

  • Transducer characterization from pressure amplitude distribution measurements using a Kalman filter as parameter estimation algorithm.

    abstract::The amplitude and frequency contents of a received ultrasound pulse depends on the spatial pressure amplitude distribution of the sound field, as produced by the transducer in the medium, and on the position and orientation of the reflecting surface in this field. Often, the geometry of the reflecting surface and the ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469001200405

    authors: Linssen FM,Hoeks AP

    更新日期:1990-10-01 00:00:00

  • Computerized ultrasound B-scan texture analysis of experimental fatty liver disease: influence of total lipid content and fat deposit distribution.

    abstract::Statistical pattern recognition procedures allow a quantitative description of ultrasound-B-scan image texture. According to well-established animal models, different types of fatty liver disease were induced in female Wistar rats. For the correlation of the computerized ultrasound image with its underlying histology ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469001200302

    authors: Layer G,Zuna I,Lorenz A,Zerban H,Haberkorn U,Bannasch P,van Kaick G,Räth U

    更新日期:1990-07-01 00:00:00

  • Numerical study of higher-order diffraction tomography via the sinc basis moment method.

    abstract::Behavior and limitations of the sinc basis method have been discovered during simulation studies. An iterative row-action method (ART) is compared with a full-matrix, least-squares solution (QR decomposition) and the problem of multiple solutions is discussed. Knowledge of the spatial distribution of scattered field e...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468901100103

    authors: Cavicchi TJ,O'Brien WD Jr

    更新日期:1989-01-01 00:00:00

  • Optimization of signal-to-noise ratio for multilayer PZT transducers.

    abstract::In medical ultrasound imaging, two-dimensional (2-D) array transducers are desirable to implement dynamic focusing and phase aberration correction in two dimensions as well as volumetric imaging. Unfortunately, the small size of a 2-D array element results in a small clamped capacitance and a large electrical impedanc...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469501700202

    authors: Goldberg RL,Smith SW

    更新日期:1995-04-01 00:00:00

  • A comparison method for mean frequency estimators for Doppler ultrasound.

    abstract::Mean frequency estimators as used in pulsed Doppler ultrasound equipment should provide an accurate (quality) and consistent (robustness) estimate over a wide range of signal conditions. In a simplified signal model, the main parameters to consider are the noise level, mean frequency, bandwidth and power of both the D...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469201400404

    authors: Brands PJ,Hoeks AP

    更新日期:1992-10-01 00:00:00