Abstract:
:Sidelobe contribution from off-axis targets degrades image quality in a coherent array imaging system. In ultrasound imaging, focusing errors resulting from sound-velocity inhomogeneities in human tissue--also known as phase aberrations reduce the coherence of the received signals and elevate the sidelobe level. This paper proposes an adaptive receive-aperture technique based on thresholding of the coherence factor (CF). The CF describes the coherence of the received array signals and can be used as an index of focusing quality. This paper demonstrates that thresholding of the CF allows the mainlobe-dominated signals to be distinguished from the sidelobe-dominated signals, after which the receive-aperture size at each imaging position can be optimally determined so as to enhance the mainlobe-dominated signals and suppress the sidelobe-dominated signals. Thus, image quality degradation resulting from sound-velocity inhomogeneities can be reduced. Simulations and measured ultrasound data are used to evaluate the efficacy of the proposed technique. The characteristics of the proposed technique including the effects of the signal-to-noise ratio (SNR) and the transmit focal depth, and speckle reduction are discussed. The proposed technique is also compared with the parallel adaptive receive compensation algorithm and shown to produce a better improvement in image quality.
journal_name
Ultrason Imagingjournal_title
Ultrasonic imagingauthors
Li ML,Huang SW,Ustüner K,Li PCdoi
10.1177/016173460502700205subject
Has Abstractpub_date
2005-04-01 00:00:00pages
111-27issue
2eissn
0161-7346issn
1096-0910journal_volume
27pub_type
杂志文章abstract::The amplitude and frequency contents of a received ultrasound pulse depends on the spatial pressure amplitude distribution of the sound field, as produced by the transducer in the medium, and on the position and orientation of the reflecting surface in this field. Often, the geometry of the reflecting surface and the ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469001200405
更新日期:1990-10-01 00:00:00
abstract::Most methods for in vivo quantitation of ultrasound attenuation and backscatter are not available clinically because they rely upon acquiring and analyzing radio frequency (rf) echo signals. This paper describes a technique to estimate ultrasound attenuation and backscatter from B-mode image data. The video signal ana...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469701900305
更新日期:1997-07-01 00:00:00
abstract::Behavior and limitations of the sinc basis method have been discovered during simulation studies. An iterative row-action method (ART) is compared with a full-matrix, least-squares solution (QR decomposition) and the problem of multiple solutions is discussed. Knowledge of the spatial distribution of scattered field e...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468901100103
更新日期:1989-01-01 00:00:00
abstract::In this work, we study linear array beamforming for vibro-acoustography systems. The goal of this research is to assess the feasibility of vibro-acoustography imaging systems based on linear arrays for clinical applications. The vibro-acoustography transducer is designed with two arrays driven by two continuous-wave o...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460402600101
更新日期:2004-01-01 00:00:00
abstract::Modern ultrasound Doppler systems are facing the problem of processing increasingly shorter data sets. Spectral analysis of the strongly nonstationary Doppler signal needs to shorten the analysis window while maintaining a low variance and high resolution spectrum. Color flow imaging requires estimation of the Doppler...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469501700101
更新日期:1995-01-01 00:00:00
abstract::The aim of this study was to assess whether acoustic structure quantification (ASQ) can differentiate normal from pathological thyroid parenchyma in patients with diffuse autoimmune thyroid disease (AITD). We evaluated 83 subjects (72 [87%] women and 11 [13%] men) aged 19 to 94 years with a mean age of 53 years. We pe...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615580766
更新日期:2016-03-01 00:00:00
abstract::This study shows that the amplitude information of ultrasound echoes is carried mainly by the envelope peaks (EPs). It is first shown that the EPs in an A-line represent the maximum number of independent amplitude data. It is then demonstrated that the entire envelope could be approximately reconstructed from the EPs....
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468801000403
更新日期:1988-10-01 00:00:00
abstract::Global and local attenuation coefficient estimations were performed in a phantom using a pulse echo method based on the rate of decay of zero crossing density. Focussed and unfocussed 3.5 MHz transducers were used. It was found that good global estimates could be made with either transducer over a 2:1 range of attenua...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468500700202
更新日期:1985-04-01 00:00:00
abstract::Mean frequency estimators as used in pulsed Doppler ultrasound equipment should provide an accurate (quality) and consistent (robustness) estimate over a wide range of signal conditions. In a simplified signal model, the main parameters to consider are the noise level, mean frequency, bandwidth and power of both the D...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469201400404
更新日期:1992-10-01 00:00:00
abstract::Ultrasonic waveform data from a tissue-mimicking phantom containing low contrast targets was digitized, stored and processed prior to creating and displaying ultrasonic images. Speckle reduction was performed by digital filtering of the waveform data with appropriately spaced and weighted digital filters, prior to bot...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468700900202
更新日期:1987-04-01 00:00:00
abstract::This paper addresses significant sources of electromagnetic noise in Hall effect imaging. Hall effect imaging employs large electrical pulses for signal generation and high sensitivity ultrasonic probes for signal reception. Coherent noise arises through various coupling mechanisms between the excitation pulse and the...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469802000305
更新日期:1998-07-01 00:00:00
abstract::Optimal transmit phasing has been proposed to increase contrast-to-tissue ratio (CTR) by relatively phasing the tissue and leakage harmonic components to cancel each other out for tissue-background suppression in harmonic imaging. Since most clinical systems are only equipped with a bipolar square-wave pulser, effecti...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173461003200103
更新日期:2010-01-01 00:00:00
abstract::Attenuation measurements of various tissue mimicking phantoms and three different groups of patients were obtained using a modified commercial sector scanner. Estimates of attenuation were made using the spectral shift method with mean frequencies at different depths of a region of interest being obtained by both zero...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468400600402
更新日期:1984-10-01 00:00:00
abstract::The aim of this study was to identify independent risk factors for thyroid cancer, establish an ultrasonographic multimodality diagnostic model for thyroid nodules, and explore the diagnostic value of the model. From November 2011 to February 2015, 307 patients with a total of 367 thyroid nodules underwent conventiona...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734618815070
更新日期:2019-03-01 00:00:00
abstract::Acoustic radiation force (ARF) has become a common excitation mechanism in elasticity imaging. The high acoustic intensities and subsequent generation of harmonics, however, hamper the effectiveness of using conventional radiofrequency (rf) tracking to investigate the dynamics of tissues and catheter-based transducers...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:
更新日期:2009-01-01 00:00:00
abstract::Muscle fatigue often occurs over a long period of exercise, and it can increase the risk of muscle injury. Evaluating the state of muscle fatigue can avoid unnecessary overtraining and injury of the muscle. Ultrasound imaging can non-invasively visualize muscle tissue in real-time. Image entropy is commonly used to ch...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734620952683
更新日期:2020-11-01 00:00:00
abstract::A narrow-band ultrasonic shear-wave imaging technique for estimating phase speed was applied to fresh and thermally damaged porcine liver in vitro. Two constitutive models were applied to the measurements to represent rheological behavior of the tissue and estimate the complex shear modulus at frequencies between 50 a...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173461003200405
更新日期:2010-10-01 00:00:00
abstract::Peripheral artery disease is often asymptomatic, and various imaging and nonimaging techniques have been used for assessment and monitoring treatments. This study is designed to demonstrate the ability of photoacoustic imaging to noninvasively determine changes in tissue oxygenation that occur in mice's hind limb skel...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734619862287
更新日期:2019-09-01 00:00:00
abstract::A Fourier transform (FT)-based technique for forming parallel receive beams has been previously employed to increase the imaging frame rate in ultrasonic imaging. However, the image quality in FT-based parallel reconstruction is degraded because differences in range focusing delays are ignored and a wide transmit beam...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460302500201
更新日期:2003-04-01 00:00:00
abstract::An algorithm for deconvolution of medical ultrasound images is presented. The procedure involves estimation of the basic one-dimensional ultrasound pulse, determining the ratio of the covariance of the noise to the covariance of the reflection signal, and finally deconvolution of the rf signal from the transducer. Usi...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469301500204
更新日期:1993-04-01 00:00:00
abstract::Anova and "dummy variables" least squares regression methods are used to investigate the dependence of ultrasound propagation velocity on the presence or absence of fat and on the rank ordered level of cirrhosis in fixed human liver. Cirrhosis is found to affect velocity in a nonlinear fashion, while fat depresses the...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468300500306
更新日期:1983-07-01 00:00:00
abstract::Conventional ultrasonic B-mode images qualitatively describe tissue structures but are unsuitable for quantitative analyses of scatterer properties. We have recently developed an ultrasonic parametric imaging technique based on the Nakagami statistical distribution that is able to quantify scatterer concentrations. Th...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460803000202
更新日期:2008-04-01 00:00:00
abstract::The propagation of pressure pulses of arbitrary time form in inhomogeneous attenuating media with characteristics similar to real biological tissues is considered. A mathematical model using the quasi-optical approximation is developed to solve the wave equation. Such a model proves to be convenient for computer reali...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469301500106
更新日期:1993-01-01 00:00:00
abstract::The theory of diffraction tomography for two-dimensional objects within the Born approximation is presented for cases where the scattered field is measured over arbitrarily shaped boundaries surrounding the object. Reconstruction algorithms are presented for both plane wave (parallel beam) and cylindrical wave (fan be...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468400600207
更新日期:1984-04-01 00:00:00
abstract::Breast ultrasound (BUS) imaging has become a crucial modality, especially for providing a complementary view when other modalities (i.e., mammography) are not conclusive in the task of assessing lesions. The specificity in cancer detection using BUS imaging is low. These false-positive findings often lead to an increa...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615589287
更新日期:2016-05-01 00:00:00
abstract::Two-dimensional echocardiography (2-D echo) imaging is a more attractive clinical tool than other modalities that either involve radiation exposure or are too slow to image heart motion in real-time. Computer-aided analysis of left ventricular(LV) wall motion provides quantitative parameters for diagnosis. This study ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469701900204
更新日期:1997-04-01 00:00:00
abstract::Accurate tracking of tissue motion is critically important for several ultrasound elastography methods. In this study, we investigate the feasibility of using three published convolution neural network (CNN) models built for optical flow (hereafter referred to as CNN-based tracking) by the computer vision community fo...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734620902527
更新日期:2020-03-01 00:00:00
abstract::Many noninvasive ultrasound techniques have been developed to explore mechanical properties of soft tissues. One of these methods, Localized Harmonic Motion Imaging (LHMI), has been proposed to be used for ultrasound surgery monitoring. In LHMI, dynamic ultrasound radiation-force stimulation induces displacements in a...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460602800203
更新日期:2006-04-01 00:00:00
abstract::Volume reconstruction method plays an important role in improving reconstructed volumetric image quality for freehand three-dimensional (3D) ultrasound imaging. By utilizing the capability of programmable graphics processing unit (GPU), we can achieve a real-time incremental volume reconstruction at a speed of 25-50 f...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734616689464
更新日期:2017-07-01 00:00:00
abstract::In recent years, adaptive minimum-variance (MV) beamforming has been successfully applied to medical ultrasound imaging, resulting in simultaneous improvement in imaging resolution and contrast. MV has high resolution and hence can provide accurate estimates of the target locations. However, the MV amplitude estimates...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615600167
更新日期:2016-07-01 00:00:00