听力与言语-语言病理学

行为科学

医学伦理学

你正在浏览ULTRASONIC IMAGING期刊下所有文献
  • Skeletal Muscle Fatigue State Evaluation with Ultrasound Image Entropy.

    abstract::Muscle fatigue often occurs over a long period of exercise, and it can increase the risk of muscle injury. Evaluating the state of muscle fatigue can avoid unnecessary overtraining and injury of the muscle. Ultrasound imaging can non-invasively visualize muscle tissue in real-time. Image entropy is commonly used to ch...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734620952683

    authors: Li P,Yang X,Yin G,Guo J

    更新日期:2020-11-01 00:00:00

  • Neural-network-based Motion Tracking for Breast Ultrasound Strain Elastography: An Initial Assessment of Performance and Feasibility.

    abstract::Accurate tracking of tissue motion is critically important for several ultrasound elastography methods. In this study, we investigate the feasibility of using three published convolution neural network (CNN) models built for optical flow (hereafter referred to as CNN-based tracking) by the computer vision community fo...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734620902527

    authors: Peng B,Xian Y,Zhang Q,Jiang J

    更新日期:2020-03-01 00:00:00

  • Toward Noninvasive Mapping of Diffuse Scattering in the Presence of Motion.

    abstract::Ultrasonic coda wave analysis techniques localize defects in fields such as seismography and nondestructive testing. In medical ultrasound, these techniques might provide novel mapping of tissue properties in diseases characterized by local fibrosis. In this work, we present an approach for localizing variation in sca...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734619899885

    authors: Lindsey BD,Collins GC

    更新日期:2020-01-01 00:00:00

  • Assessment of Age-related Oxygenation Changes in Calf Skeletal Muscle by Photoacoustic Imaging: A Potential Tool for Peripheral Arterial Disease.

    abstract::Peripheral artery disease is often asymptomatic, and various imaging and nonimaging techniques have been used for assessment and monitoring treatments. This study is designed to demonstrate the ability of photoacoustic imaging to noninvasively determine changes in tissue oxygenation that occur in mice's hind limb skel...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734619862287

    authors: Kirkham BM,Schultz SM,Ashi K,Sehgal CM

    更新日期:2019-09-01 00:00:00

  • A Variance-reduction Approach to Detection of the Thyroid-nodule Boundary on Ultrasound Images.

    abstract::To perform computer-aided diagnosis of the thyroid nodules on ultrasound images, the location and boundary of nodules should be clearly defined. However, the identification of thyroid nodule boundary is a difficult issue due to the biological characteristics of the nodules, the physics and quality of ultrasound imagin...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734619839648

    authors: Chiu LY,Chen A

    更新日期:2019-07-01 00:00:00

  • Ultrasonographic Multimodality Diagnostic Model of Thyroid Nodules.

    abstract::The aim of this study was to identify independent risk factors for thyroid cancer, establish an ultrasonographic multimodality diagnostic model for thyroid nodules, and explore the diagnostic value of the model. From November 2011 to February 2015, 307 patients with a total of 367 thyroid nodules underwent conventiona...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734618815070

    authors: Zhao RN,Zhang B,Jiang YX,Yang X,Lai XJ,Zhu SL,Zhang XY

    更新日期:2019-03-01 00:00:00

  • Compressed Sensing for Elastography in Portable Ultrasound.

    abstract::Portable ultrasound is recently emerging as a new medical imaging modality featuring high portability, easy connectivity, and real-time on-site diagnostic ability. However, it does not yet provide ultrasound elastography function that enables the diagnosis of malignant lesions using elastic properties. This is mainly ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734617716938

    authors: Shin B,Jeon S,Ryu J,Kwon HJ

    更新日期:2017-11-01 00:00:00

  • A Review of Ultrasound Tissue Characterization with Mean Scatterer Spacing.

    abstract::Tissues exhibiting quasi-periodic structures can be modeled as a collection of diffuse scatterers and coherent scatterers. The mean scatterer spacing (MSS) of coherent and quasi-periodic components is directly related to tissue microstructure and has become an important quantitative ultrasound (QUS) parameter in the c...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章,评审

    doi:10.1177/0161734617692018

    authors: Zhou Z,Wu W,Wu S,Jia K,Tsui PH

    更新日期:2017-09-01 00:00:00

  • GPU-accelerated Kernel Regression Reconstruction for Freehand 3D Ultrasound Imaging.

    abstract::Volume reconstruction method plays an important role in improving reconstructed volumetric image quality for freehand three-dimensional (3D) ultrasound imaging. By utilizing the capability of programmable graphics processing unit (GPU), we can achieve a real-time incremental volume reconstruction at a speed of 25-50 f...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734616689464

    authors: Wen T,Li L,Zhu Q,Qin W,Gu J,Yang F,Xie Y

    更新日期:2017-07-01 00:00:00

  • Rotation Elastogram Estimation Using Synthetic Transmit-aperture Technique: A Feasibility Study.

    abstract::It is well-documented in literature that benign breast lesions, such as fibroadenomas, are loosely bonded to their surrounding tissue and tend to slip under a small quasi-static compression, whereas malignant lesions being firmly bonded to their surrounding tissue do not slip. Recent developments in quasi-static ultra...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734616686746

    authors: B L,Chintada BR,Thittai AK

    更新日期:2017-05-01 00:00:00

  • Experimental Validation of ARFI Surveillance of Subcutaneous Hemorrhage (ASSH) Using Calibrated Infusions in a Tissue-Mimicking Model and Dogs.

    abstract::Acoustic radiation force impulse (ARFI) Surveillance of Subcutaneous Hemorrhage (ASSH) has been previously demonstrated to differentiate bleeding phenotype and responses to therapy in dogs and humans, but to date, the method has lacked experimental validation. This work explores experimental validation of ASSH in a po...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615617940

    authors: Geist RE,DuBois CH,Nichols TC,Caughey MC,Merricks EP,Raymer R,Gallippi CM

    更新日期:2016-09-01 00:00:00

  • Combining the APES and Minimum-variance Beamformers for Adaptive Ultrasound Imaging.

    abstract::In recent years, adaptive minimum-variance (MV) beamforming has been successfully applied to medical ultrasound imaging, resulting in simultaneous improvement in imaging resolution and contrast. MV has high resolution and hence can provide accurate estimates of the target locations. However, the MV amplitude estimates...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615600167

    authors: Mohammadzadeh Asl B

    更新日期:2016-07-01 00:00:00

  • Breast-lesion Segmentation Combining B-Mode and Elastography Ultrasound.

    abstract::Breast ultrasound (BUS) imaging has become a crucial modality, especially for providing a complementary view when other modalities (i.e., mammography) are not conclusive in the task of assessing lesions. The specificity in cancer detection using BUS imaging is low. These false-positive findings often lead to an increa...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615589287

    authors: Pons G,Martí J,Martí R,Ganau S,Noble JA

    更新日期:2016-05-01 00:00:00

  • Acoustic Structure Quantification Analysis of the Thyroid in Patients with Diffuse Autoimmune Thyroid Disease.

    abstract::The aim of this study was to assess whether acoustic structure quantification (ASQ) can differentiate normal from pathological thyroid parenchyma in patients with diffuse autoimmune thyroid disease (AITD). We evaluated 83 subjects (72 [87%] women and 11 [13%] men) aged 19 to 94 years with a mean age of 53 years. We pe...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615580766

    authors: Zandieh S,Bernt R,Zwerina J,Haller J,Knoll P,Seyeddain O,Mirzaei S

    更新日期:2016-03-01 00:00:00

  • Effective scatterer diameter estimates for broad scatterer size distributions.

    abstract::Acoustic form factors have been used to model the frequency dependence of acoustic scattering in phantoms and tissues. This work demonstrates that a broad range of scatterer sizes, individually well represented by Faran theory or a Gaussian form factor, is not accurately described by a single effective scatterer from ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734614534399

    authors: Nordberg EP,Hall TJ

    更新日期:2015-01-01 00:00:00

  • Mean scatterer spacing estimation in normal and thermally coagulated ex vivo bovine liver.

    abstract::The liver has been hypothesized to have a unique arrangement of microvasculature that presents as an arrangement of quasiperiodic scatterers to an interrogating ultrasound pulse. The mean scatterer spacing (MSS) of these quasiperiodic scatterers has been proposed as a useful quantitative ultrasound biomarker for chara...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734613511232

    authors: Rubert N,Varghese T

    更新日期:2014-04-01 00:00:00

  • Variance and covariance of accumulated displacement estimates.

    abstract::Tracking large deformations in tissue using ultrasound can enable the reconstruction of nonlinear elastic parameters, but poses a challenge to displacement estimation algorithms. Such large deformations have to be broken up into steps, each of which contributes an estimation error to the final accumulated displacement...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734613479246

    authors: Bayer M,Hall TJ

    更新日期:2013-04-01 00:00:00

  • Subharmonic contrast microbubble signals for noninvasive pressure estimation under static and dynamic flow conditions.

    abstract::Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled co...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173461103300301

    authors: Halldorsdottir VG,Dave JK,Leodore LM,Eisenbrey JR,Park S,Hall AL,Thomenius K,Forsberg F

    更新日期:2011-07-01 00:00:00

  • Dispersion and shear modulus measurements of porcine liver.

    abstract::A narrow-band ultrasonic shear-wave imaging technique for estimating phase speed was applied to fresh and thermally damaged porcine liver in vitro. Two constitutive models were applied to the measurements to represent rheological behavior of the tissue and estimate the complex shear modulus at frequencies between 50 a...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173461003200405

    authors: Orescanin M,Qayyum MA,Toohey KS,Insana MF

    更新日期:2010-10-01 00:00:00

  • Optimal transmit phasing for harmonic-background suppression with bipolar square-wave pulser.

    abstract::Optimal transmit phasing has been proposed to increase contrast-to-tissue ratio (CTR) by relatively phasing the tissue and leakage harmonic components to cancel each other out for tissue-background suppression in harmonic imaging. Since most clinical systems are only equipped with a bipolar square-wave pulser, effecti...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173461003200103

    authors: Shen CC,Yang YC,Chen WS

    更新日期:2010-01-01 00:00:00

  • On the feasibility of imaging peripheral nerves using acoustic radiation force impulse imaging.

    abstract::Regional anesthesia is preferred over general anesthesia for many surgical procedures; however, challenges associated with poor image guidance limit its widespread acceptance as a viable alternative. In B-mode ultrasound images, the current standard for guidance, nerves can be difficult to visualize due to their simil...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460903100303

    authors: Palmeri ML,Dahl JJ,MacLeod DB,Grant SA,Nightingale KR

    更新日期:2009-07-01 00:00:00

  • Optical tracking of superficial dynamics from an acoustic radiation force-induced excitation.

    abstract::Acoustic radiation force (ARF) has become a common excitation mechanism in elasticity imaging. The high acoustic intensities and subsequent generation of harmonics, however, hamper the effectiveness of using conventional radiofrequency (rf) tracking to investigate the dynamics of tissues and catheter-based transducers...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:

    authors: Bouchard RR,Van Soest G,Trahey GE,Van Der Steen AF

    更新日期:2009-01-01 00:00:00

  • Feasibility exploration of blood flow estimation by contrast-assisted Nakagami imaging.

    abstract::The microbubble contrast agent destruction/replenishment technique has been widely applied to ultrasound-based blood flow estimation. The rate of increase of the time-intensity curve (TIC) due to microbubbles flowing into the region of interest as measured from B-mode images closely reflects the flow velocity. In this...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460803000301

    authors: Tsui PH,Yeh CK,Chang CC

    更新日期:2008-07-01 00:00:00

  • Performance evaluation of ultrasonic Nakagami image in tissue characterization.

    abstract::Conventional ultrasonic B-mode images qualitatively describe tissue structures but are unsuitable for quantitative analyses of scatterer properties. We have recently developed an ultrasonic parametric imaging technique based on the Nakagami statistical distribution that is able to quantify scatterer concentrations. Th...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460803000202

    authors: Tsui PH,Yeh CK,Chang CC,Chen WS

    更新日期:2008-04-01 00:00:00

  • Investigation of optimal method for inducing harmonic motion in tissue using a linear ultrasound phased array--a simulation study.

    abstract::Many noninvasive ultrasound techniques have been developed to explore mechanical properties of soft tissues. One of these methods, Localized Harmonic Motion Imaging (LHMI), has been proposed to be used for ultrasound surgery monitoring. In LHMI, dynamic ultrasound radiation-force stimulation induces displacements in a...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460602800203

    authors: Heikkilä J,Hynynen K

    更新日期:2006-04-01 00:00:00

  • Ultrasonic backscatter and attenuation (11-27 MHz) variation with collagen fiber distribution in ex vivo human dermis.

    abstract::This ex vivo study explores the relationship of ultrasonic attenuation and backscatter to dermal microarchitecture by comparing ultrasonic measurements of these parameters (11-27 MHz) to a microscopic analysis of three parameters describing the collagen distribution (mean thickness and spacing of collagen bundles alon...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460602800103

    authors: Bridal SL,Fournier C,Coron A,Leguerney I,Laugier P

    更新日期:2006-01-01 00:00:00

  • Adaptive imaging using an optimal receive aperture size.

    abstract::Sidelobe contribution from off-axis targets degrades image quality in a coherent array imaging system. In ultrasound imaging, focusing errors resulting from sound-velocity inhomogeneities in human tissue--also known as phase aberrations reduce the coherence of the received signals and elevate the sidelobe level. This ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460502700205

    authors: Li ML,Huang SW,Ustüner K,Li PC

    更新日期:2005-04-01 00:00:00

  • Real-time 3D transesophageal echocardiography.

    abstract::Transesophageal echocardiography (TEE) is an essential diagnostic tool in patients with poor transthoracic echocardiographic windows or when detailed imaging of structures distant from the chest wall is necessary. A real-time 3D TEE probe has been fabricated in our laboratory in order to increase the amount of informa...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460402600402

    authors: Pua EC,Idriss SF,Wolf PD,Smith SW

    更新日期:2004-10-01 00:00:00

  • Linear arrays for vibro-acoustography: a numerical simulation study.

    abstract::In this work, we study linear array beamforming for vibro-acoustography systems. The goal of this research is to assess the feasibility of vibro-acoustography imaging systems based on linear arrays for clinical applications. The vibro-acoustography transducer is designed with two arrays driven by two continuous-wave o...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460402600101

    authors: Silva GT,Greenleaf JF,Fatemi M

    更新日期:2004-01-01 00:00:00

  • Adaptive scan sequence for real-time ultrasound 3-D imaging.

    abstract::An adaptive scan sequence is proposed for real-time ultrasound three-dimensional (3-D) imaging. Generally, the refresh rate of 3-D imaging is limited by the view window, resolution and sound speed in the human body. If the object is transformed or moved during the data set acquisition, the 3-D image will be distorted....

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460302500401

    authors: Hashimoto H,Takeuchi Y

    更新日期:2003-10-01 00:00:00

  • A scalable architecture for real-time synthetic-focus imaging.

    abstract::A scalable architecture for forming real-time synthetic focus images is described and the design of a 256-channel system using currently-available technology is presented as an example implementation of the architecture. The parallelism of the system scales directly with the number of array elements and the image comp...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460302500303

    authors: Richard WD

    更新日期:2003-07-01 00:00:00

  • Improved Fourier-transform-based parallel receive beam formation.

    abstract::A Fourier transform (FT)-based technique for forming parallel receive beams has been previously employed to increase the imaging frame rate in ultrasonic imaging. However, the image quality in FT-based parallel reconstruction is degraded because differences in range focusing delays are ignored and a wide transmit beam...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460302500201

    authors: Li ML,Li PC

    更新日期:2003-04-01 00:00:00

  • Temperature dependence of ultrasonic propagation speed and attenuation in canine tissue.

    abstract::Previously reported data on the temperature dependence of propagation speed in tissues generally span only temperature ranges up to 60 degrees C. However, with the emerging use of thermal ablative therapies, information on variation in this parameter over higher temperature ranges is needed. Measurements of the ultras...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460202400404

    authors: Techavipoo U,Varghese T,Zagzebski JA,Stiles T,Frank G

    更新日期:2002-10-01 00:00:00

  • Observations of tissue response to acoustic radiation force: opportunities for imaging.

    abstract::Acoustic Radiation Force Impulse (ARFI) imaging is a method for characterizing local variations in tissue mechanical properties. In this method, a single ultrasonic transducer array is used to both apply temporally short localized radiation forces within tissue and to track the resulting displacements through time. In...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460202400301

    authors: Nightingale K,Bentley R,Trahey G

    更新日期:2002-07-01 00:00:00

  • An efficient motion estimation and compensation method for ultrasound synthetic aperture imaging.

    abstract::This paper describes a method for overcoming motion artifacts in synthetic aperture imaging. The method is based on a computer simulation study on the influence of target motion on synthetic aperture techniques. A region-based motion compensation approach is used in which only the axial motion is estimated and compens...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460202400202

    authors: Kim KS,Hwang JS,Jeong JS,Song TK

    更新日期:2002-04-01 00:00:00

  • A study of the display pixel-based focusing method in ultrasound imaging.

    abstract::This paper presents a new beamforming technique, in which ultrasound waves are focused at the display pixels on the Cartesian coordinates, rather than sampling points located on the uniformly-separated scanlines on either the polar or Cartesian coordinates. Consequently, this method does not require a digital scan con...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460102300101

    authors: Hwang JS,Song TK

    更新日期:2001-01-01 00:00:00

  • Reconstructive ultrasound elasticity imaging for renal transplant diagnosis: kidney ex vivo results.

    abstract::It may be possible to diagnose and monitor scarring, inflammation and edema in transplant kidney using reconstructive ultrasound elasticity imaging. Kidney elasticity is expected to change dramatically with scar, and to a lesser degree, with acute inflammation and edema. The hypothesis that changes in kidney elasticit...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460002200303

    authors: Emelianov SY,Lubinski MA,Skovoroda AR,Erkamp RQ,Leavey SF,Wiggins RC,O'Donnell M

    更新日期:2000-07-01 00:00:00

  • Wavelet-based speckle noise reduction in ultrasound B-scan images.

    abstract::Speckle noise is known to be signal-dependent in ultrasound imaging. Hence, separating noise from signal becomes a difficult task. This paper describes a wavelet-based method for reducing speckle noise. We derive from the model of the displayed ultrasound image the optimal wavelet-domain filter in the least mean-squar...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460002200201

    authors: Rakotomamonjy A,Deforge P,Marché P

    更新日期:2000-04-01 00:00:00

  • Effects of transmit focusing on finite amplitude distortion based second harmonic generation.

    abstract::Generation of the second harmonic signal was studied for finite amplitude distortion based harmonic imaging. Acoustic field amplitudes along the range axis of a fixed focus transducer were measured using a PVDF needle hydrophone. Results indicated that on-axis amplitudes strongly depended on the f-number at both the f...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469902100401

    authors: Li PC,Shen CC

    更新日期:1999-10-01 00:00:00

  • Volumetric Hall effect tomography--a feasibility study.

    abstract::Hall effect imaging is an ultrasound-based method of mapping spatial variations in the dielectric constants of an acoustically-uniform sample. This paper presents three-dimensional Hall effect images of phantoms obtained by scanning a single transducer across a two-dimensional grid, effectively simulating two-dimensio...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469902100303

    authors: Wen H

    更新日期:1999-07-01 00:00:00

74 条记录 1/2 页 « 12 »