Abstract:
:Two-dimensional echocardiography (2-D echo) imaging is a more attractive clinical tool than other modalities that either involve radiation exposure or are too slow to image heart motion in real-time. Computer-aided analysis of left ventricular(LV) wall motion provides quantitative parameters for diagnosis. This study presents a computerized model for quantitative analysis of left ventricular wall motion from two-dimensional echocardiography by the application of image processing algorithms, including automatic threshold estimation, contrast stretching, boundary detection and border smoothing. The wall motion measurements rely primarily on sequential changes from end-diastolic to end-systolic frames in the left ventricular contours of apical four-chamber view echocardiograms. Left ventricular wall motion was analyzed on the 30 segments of 5 patients with acute myocardial infarction. The results from the computerized model were compared to those obtained from qualitative analysis of echocardiograms by an experienced clinical cardiologist who was unaware of the results of quantitative data.
journal_name
Ultrason Imagingjournal_title
Ultrasonic imagingauthors
Chen T,Chen TP,Tsai LMdoi
10.1177/016173469701900204subject
Has Abstractpub_date
1997-04-01 00:00:00pages
138-44issue
2eissn
0161-7346issn
1096-0910journal_volume
19pub_type
杂志文章abstract::Breast ultrasound (BUS) imaging has become a crucial modality, especially for providing a complementary view when other modalities (i.e., mammography) are not conclusive in the task of assessing lesions. The specificity in cancer detection using BUS imaging is low. These false-positive findings often lead to an increa...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615589287
更新日期:2016-05-01 00:00:00
abstract::Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled co...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173461103300301
更新日期:2011-07-01 00:00:00
abstract::It is well-documented in literature that benign breast lesions, such as fibroadenomas, are loosely bonded to their surrounding tissue and tend to slip under a small quasi-static compression, whereas malignant lesions being firmly bonded to their surrounding tissue do not slip. Recent developments in quasi-static ultra...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734616686746
更新日期:2017-05-01 00:00:00
abstract::An adaptive scan sequence is proposed for real-time ultrasound three-dimensional (3-D) imaging. Generally, the refresh rate of 3-D imaging is limited by the view window, resolution and sound speed in the human body. If the object is transformed or moved during the data set acquisition, the 3-D image will be distorted....
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460302500401
更新日期:2003-10-01 00:00:00
abstract::Coherent speckle is a source of image noise in ultrasonic B-mode imaging. The use of multiple imaging frequencies has been suggested as a technique for speckle contrast reduction. This technique involves the averaging of images whose speckle patterns have been modified by a change in the spectrum of the transmitted or...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468600800301
更新日期:1986-07-01 00:00:00
abstract::Portable ultrasound is recently emerging as a new medical imaging modality featuring high portability, easy connectivity, and real-time on-site diagnostic ability. However, it does not yet provide ultrasound elastography function that enables the diagnosis of malignant lesions using elastic properties. This is mainly ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734617716938
更新日期:2017-11-01 00:00:00
abstract::This ex vivo study explores the relationship of ultrasonic attenuation and backscatter to dermal microarchitecture by comparing ultrasonic measurements of these parameters (11-27 MHz) to a microscopic analysis of three parameters describing the collagen distribution (mean thickness and spacing of collagen bundles alon...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460602800103
更新日期:2006-01-01 00:00:00
abstract::Behavior and limitations of the sinc basis method have been discovered during simulation studies. An iterative row-action method (ART) is compared with a full-matrix, least-squares solution (QR decomposition) and the problem of multiple solutions is discussed. Knowledge of the spatial distribution of scattered field e...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468901100103
更新日期:1989-01-01 00:00:00
abstract::This paper presents a new beamforming technique, in which ultrasound waves are focused at the display pixels on the Cartesian coordinates, rather than sampling points located on the uniformly-separated scanlines on either the polar or Cartesian coordinates. Consequently, this method does not require a digital scan con...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460102300101
更新日期:2001-01-01 00:00:00
abstract::Transesophageal echocardiography (TEE) is an essential diagnostic tool in patients with poor transthoracic echocardiographic windows or when detailed imaging of structures distant from the chest wall is necessary. A real-time 3D TEE probe has been fabricated in our laboratory in order to increase the amount of informa...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460402600402
更新日期:2004-10-01 00:00:00
abstract::This study shows that the amplitude information of ultrasound echoes is carried mainly by the envelope peaks (EPs). It is first shown that the EPs in an A-line represent the maximum number of independent amplitude data. It is then demonstrated that the entire envelope could be approximately reconstructed from the EPs....
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468801000403
更新日期:1988-10-01 00:00:00
abstract::An algorithm for deconvolution of medical ultrasound images is presented. The procedure involves estimation of the basic one-dimensional ultrasound pulse, determining the ratio of the covariance of the noise to the covariance of the reflection signal, and finally deconvolution of the rf signal from the transducer. Usi...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469301500204
更新日期:1993-04-01 00:00:00
abstract::The propagation of pressure pulses of arbitrary time form in inhomogeneous attenuating media with characteristics similar to real biological tissues is considered. A mathematical model using the quasi-optical approximation is developed to solve the wave equation. Such a model proves to be convenient for computer reali...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469301500106
更新日期:1993-01-01 00:00:00
abstract::Optimal transmit phasing has been proposed to increase contrast-to-tissue ratio (CTR) by relatively phasing the tissue and leakage harmonic components to cancel each other out for tissue-background suppression in harmonic imaging. Since most clinical systems are only equipped with a bipolar square-wave pulser, effecti...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173461003200103
更新日期:2010-01-01 00:00:00
abstract::The aim of this study was to assess whether acoustic structure quantification (ASQ) can differentiate normal from pathological thyroid parenchyma in patients with diffuse autoimmune thyroid disease (AITD). We evaluated 83 subjects (72 [87%] women and 11 [13%] men) aged 19 to 94 years with a mean age of 53 years. We pe...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615580766
更新日期:2016-03-01 00:00:00
abstract::This paper describes a method for overcoming motion artifacts in synthetic aperture imaging. The method is based on a computer simulation study on the influence of target motion on synthetic aperture techniques. A region-based motion compensation approach is used in which only the axial motion is estimated and compens...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460202400202
更新日期:2002-04-01 00:00:00
abstract::Attenuation measurements of various tissue mimicking phantoms and three different groups of patients were obtained using a modified commercial sector scanner. Estimates of attenuation were made using the spectral shift method with mean frequencies at different depths of a region of interest being obtained by both zero...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468400600402
更新日期:1984-10-01 00:00:00
abstract::Volume reconstruction method plays an important role in improving reconstructed volumetric image quality for freehand three-dimensional (3D) ultrasound imaging. By utilizing the capability of programmable graphics processing unit (GPU), we can achieve a real-time incremental volume reconstruction at a speed of 25-50 f...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734616689464
更新日期:2017-07-01 00:00:00
abstract::Acoustic radiation force impulse (ARFI) Surveillance of Subcutaneous Hemorrhage (ASSH) has been previously demonstrated to differentiate bleeding phenotype and responses to therapy in dogs and humans, but to date, the method has lacked experimental validation. This work explores experimental validation of ASSH in a po...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615617940
更新日期:2016-09-01 00:00:00
abstract::In this work, we study linear array beamforming for vibro-acoustography systems. The goal of this research is to assess the feasibility of vibro-acoustography imaging systems based on linear arrays for clinical applications. The vibro-acoustography transducer is designed with two arrays driven by two continuous-wave o...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460402600101
更新日期:2004-01-01 00:00:00
abstract::A Fourier transform (FT)-based technique for forming parallel receive beams has been previously employed to increase the imaging frame rate in ultrasonic imaging. However, the image quality in FT-based parallel reconstruction is degraded because differences in range focusing delays are ignored and a wide transmit beam...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460302500201
更新日期:2003-04-01 00:00:00
abstract::An autoregressive (AR) spectral estimation method was considered for the purpose of estimating scatterer size images. The variance and bias of the resulting estimates were compared with those using classical FFT periodograms for a range of input signal-to-noise ratios and echo-signal durations corresponding to various...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469601800102
更新日期:1996-01-01 00:00:00
abstract::The microbubble contrast agent destruction/replenishment technique has been widely applied to ultrasound-based blood flow estimation. The rate of increase of the time-intensity curve (TIC) due to microbubbles flowing into the region of interest as measured from B-mode images closely reflects the flow velocity. In this...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460803000301
更新日期:2008-07-01 00:00:00
abstract::The aim of this study was to identify independent risk factors for thyroid cancer, establish an ultrasonographic multimodality diagnostic model for thyroid nodules, and explore the diagnostic value of the model. From November 2011 to February 2015, 307 patients with a total of 367 thyroid nodules underwent conventiona...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734618815070
更新日期:2019-03-01 00:00:00
abstract::In medical ultrasound imaging, two-dimensional (2-D) array transducers are desirable to implement dynamic focusing and phase aberration correction in two dimensions as well as volumetric imaging. Unfortunately, the small size of a 2-D array element results in a small clamped capacitance and a large electrical impedanc...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469501700202
更新日期:1995-04-01 00:00:00
abstract::Modern ultrasound Doppler systems are facing the problem of processing increasingly shorter data sets. Spectral analysis of the strongly nonstationary Doppler signal needs to shorten the analysis window while maintaining a low variance and high resolution spectrum. Color flow imaging requires estimation of the Doppler...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469501700101
更新日期:1995-01-01 00:00:00
abstract::Generation of the second harmonic signal was studied for finite amplitude distortion based harmonic imaging. Acoustic field amplitudes along the range axis of a fixed focus transducer were measured using a PVDF needle hydrophone. Results indicated that on-axis amplitudes strongly depended on the f-number at both the f...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469902100401
更新日期:1999-10-01 00:00:00
abstract::A method has been developed for mapping density and ultrasonic speed in 1 mm thick slices of soft tissue with a resolution of about 1 mm. Tests using phantom sections have verified the accuracy and resolution of the ultrasonic speed maps. The method has been applied to breast tissues of three patients including tumors...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469101300105
更新日期:1991-01-01 00:00:00
abstract::A new online signal processing technique is described to reduce speckle noise in ultrasound images. In the imaging system, a focused piston transducer is divided into thirty-two sectors. In the receive mode, parallel signal processing arranges the sectors into eight maltese crosses. The rf signals of the perpendicular...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468801000301
更新日期:1988-07-01 00:00:00
abstract::In recent years, adaptive minimum-variance (MV) beamforming has been successfully applied to medical ultrasound imaging, resulting in simultaneous improvement in imaging resolution and contrast. MV has high resolution and hence can provide accurate estimates of the target locations. However, the MV amplitude estimates...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615600167
更新日期:2016-07-01 00:00:00