Abstract:
:This study shows that the amplitude information of ultrasound echoes is carried mainly by the envelope peaks (EPs). It is first shown that the EPs in an A-line represent the maximum number of independent amplitude data. It is then demonstrated that the entire envelope could be approximately reconstructed from the EPs. Finally, using the echo data from a tissue-mimicking phantom, it is found that there are no significant differences among the attenuation coefficients estimated from the EPs, the original envelope samples, and the reconstructed envelope samples. The results of this study indicate that, in the time domain, the attenuation coefficient can be most efficiently estimated from the envelope peaks.
journal_name
Ultrason Imagingjournal_title
Ultrasonic imagingauthors
He Pdoi
10.1177/016173468801000403subject
Has Abstractpub_date
1988-10-01 00:00:00pages
265-74issue
4eissn
0161-7346issn
1096-0910journal_volume
10pub_type
杂志文章abstract::A scalable architecture for forming real-time synthetic focus images is described and the design of a 256-channel system using currently-available technology is presented as an example implementation of the architecture. The parallelism of the system scales directly with the number of array elements and the image comp...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460302500303
更新日期:2003-07-01 00:00:00
abstract::The liver has been hypothesized to have a unique arrangement of microvasculature that presents as an arrangement of quasiperiodic scatterers to an interrogating ultrasound pulse. The mean scatterer spacing (MSS) of these quasiperiodic scatterers has been proposed as a useful quantitative ultrasound biomarker for chara...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734613511232
更新日期:2014-04-01 00:00:00
abstract::When modeling or simulating an ultrasonic pulse-echo system it is necessary to know the transducer waveforms that are the input to the system. In general, accurate transducer modeling is complex and waveform calculation is computationally intensive. Because of this, investigators often assume these waveforms to be sim...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468700900405
更新日期:1987-10-01 00:00:00
abstract::In this paper, quantitative tomographic reconstructions of biological tissue are presented. First, the experimental setup and a hybrid filtered backpropagation (FBP) technique are briefly described. Using this technique, which includes exact backpropagation of data prior to reconstruction by means of the classical FBP...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469401600102
更新日期:1994-01-01 00:00:00
abstract::Behavior and limitations of the sinc basis method have been discovered during simulation studies. An iterative row-action method (ART) is compared with a full-matrix, least-squares solution (QR decomposition) and the problem of multiple solutions is discussed. Knowledge of the spatial distribution of scattered field e...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468901100103
更新日期:1989-01-01 00:00:00
abstract::Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled co...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173461103300301
更新日期:2011-07-01 00:00:00
abstract::It may be possible to diagnose and monitor scarring, inflammation and edema in transplant kidney using reconstructive ultrasound elasticity imaging. Kidney elasticity is expected to change dramatically with scar, and to a lesser degree, with acute inflammation and edema. The hypothesis that changes in kidney elasticit...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460002200303
更新日期:2000-07-01 00:00:00
abstract::This paper describes a method for overcoming motion artifacts in synthetic aperture imaging. The method is based on a computer simulation study on the influence of target motion on synthetic aperture techniques. A region-based motion compensation approach is used in which only the axial motion is estimated and compens...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460202400202
更新日期:2002-04-01 00:00:00
abstract::Statistical pattern recognition procedures allow a quantitative description of ultrasound-B-scan image texture. According to well-established animal models, different types of fatty liver disease were induced in female Wistar rats. For the correlation of the computerized ultrasound image with its underlying histology ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469001200302
更新日期:1990-07-01 00:00:00
abstract::Tissues exhibiting quasi-periodic structures can be modeled as a collection of diffuse scatterers and coherent scatterers. The mean scatterer spacing (MSS) of coherent and quasi-periodic components is directly related to tissue microstructure and has become an important quantitative ultrasound (QUS) parameter in the c...
journal_title:Ultrasonic imaging
pub_type: 杂志文章,评审
doi:10.1177/0161734617692018
更新日期:2017-09-01 00:00:00
abstract::Modern ultrasound Doppler systems are facing the problem of processing increasingly shorter data sets. Spectral analysis of the strongly nonstationary Doppler signal needs to shorten the analysis window while maintaining a low variance and high resolution spectrum. Color flow imaging requires estimation of the Doppler...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469501700101
更新日期:1995-01-01 00:00:00
abstract::Ultrasonic waveform data from a tissue-mimicking phantom containing low contrast targets was digitized, stored and processed prior to creating and displaying ultrasonic images. Speckle reduction was performed by digital filtering of the waveform data with appropriately spaced and weighted digital filters, prior to bot...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468700900202
更新日期:1987-04-01 00:00:00
abstract::Acoustic radiation force (ARF) has become a common excitation mechanism in elasticity imaging. The high acoustic intensities and subsequent generation of harmonics, however, hamper the effectiveness of using conventional radiofrequency (rf) tracking to investigate the dynamics of tissues and catheter-based transducers...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:
更新日期:2009-01-01 00:00:00
abstract::To perform computer-aided diagnosis of the thyroid nodules on ultrasound images, the location and boundary of nodules should be clearly defined. However, the identification of thyroid nodule boundary is a difficult issue due to the biological characteristics of the nodules, the physics and quality of ultrasound imagin...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734619839648
更新日期:2019-07-01 00:00:00
abstract::Speckle noise is known to be signal-dependent in ultrasound imaging. Hence, separating noise from signal becomes a difficult task. This paper describes a wavelet-based method for reducing speckle noise. We derive from the model of the displayed ultrasound image the optimal wavelet-domain filter in the least mean-squar...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460002200201
更新日期:2000-04-01 00:00:00
abstract::The potential of using the phase derivative (PD) of the radio-frequency echograms for producing 2-dimensional grey scale images was further investigated. The PD images were produced by five different algorithms, which according to the results described in the companion paper yield PD images dominated by the amplitude ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468901100301
更新日期:1989-07-01 00:00:00
abstract::Muscle fatigue often occurs over a long period of exercise, and it can increase the risk of muscle injury. Evaluating the state of muscle fatigue can avoid unnecessary overtraining and injury of the muscle. Ultrasound imaging can non-invasively visualize muscle tissue in real-time. Image entropy is commonly used to ch...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734620952683
更新日期:2020-11-01 00:00:00
abstract::A Fourier transform (FT)-based technique for forming parallel receive beams has been previously employed to increase the imaging frame rate in ultrasonic imaging. However, the image quality in FT-based parallel reconstruction is degraded because differences in range focusing delays are ignored and a wide transmit beam...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460302500201
更新日期:2003-04-01 00:00:00
abstract::Computer texture analysis methods use texture features that are traditionally chosen from a large set of fixed features known in literature. These fixed features are often not specifically designed to the problem at hand, and as a result they may have low discriminative power, and/or may be correlated. Increasing the ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章,评审
doi:10.1177/016173469802000204
更新日期:1998-04-01 00:00:00
abstract::The amplitude and frequency contents of a received ultrasound pulse depends on the spatial pressure amplitude distribution of the sound field, as produced by the transducer in the medium, and on the position and orientation of the reflecting surface in this field. Often, the geometry of the reflecting surface and the ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469001200405
更新日期:1990-10-01 00:00:00
abstract::Experimental work using a quantitative C-scan technique to measure in situ enhancement of hepatic backscatter resulting from the administration of gelatin microspheres to dogs is reported. We have found that reproducible enhancement of hepatic backscatter on the order of 2 dB followed the peripheral administration of ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468500700402
更新日期:1985-10-01 00:00:00
abstract::In recent years, adaptive minimum-variance (MV) beamforming has been successfully applied to medical ultrasound imaging, resulting in simultaneous improvement in imaging resolution and contrast. MV has high resolution and hence can provide accurate estimates of the target locations. However, the MV amplitude estimates...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615600167
更新日期:2016-07-01 00:00:00
abstract::Hall effect imaging is an ultrasound-based method of mapping spatial variations in the dielectric constants of an acoustically-uniform sample. This paper presents three-dimensional Hall effect images of phantoms obtained by scanning a single transducer across a two-dimensional grid, effectively simulating two-dimensio...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469902100303
更新日期:1999-07-01 00:00:00
abstract::An ultrasonic imaging and signal analysis system, combining a 3.5 MHz linear array B-scanner and an array processor, has been realized for a clinical liver tissue classification study. Based on the complete unprocessed rf data set of a real time B-image, local envelope power spectra averaged over interactively defined...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469401600202
更新日期:1994-04-01 00:00:00
abstract::Two-dimensional echocardiography (2-D echo) imaging is a more attractive clinical tool than other modalities that either involve radiation exposure or are too slow to image heart motion in real-time. Computer-aided analysis of left ventricular(LV) wall motion provides quantitative parameters for diagnosis. This study ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469701900204
更新日期:1997-04-01 00:00:00
abstract::For a class of scattering objects the mean separation between the scatterers is determined. Over a range of frequencies, ultrasonic back-scattered pressure signals are recorded. It is suggested to derive the mean spacing of an unknown scattering object by employing Fourier analysis and comparing the signal with signal...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468300500405
更新日期:1983-10-01 00:00:00
abstract::The theory of diffraction tomography for two-dimensional objects within the Born approximation is presented for cases where the scattered field is measured over arbitrarily shaped boundaries surrounding the object. Reconstruction algorithms are presented for both plane wave (parallel beam) and cylindrical wave (fan be...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468400600207
更新日期:1984-04-01 00:00:00
abstract::The propagation of pressure pulses of arbitrary time form in inhomogeneous attenuating media with characteristics similar to real biological tissues is considered. A mathematical model using the quasi-optical approximation is developed to solve the wave equation. Such a model proves to be convenient for computer reali...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469301500106
更新日期:1993-01-01 00:00:00
abstract::This ex vivo study explores the relationship of ultrasonic attenuation and backscatter to dermal microarchitecture by comparing ultrasonic measurements of these parameters (11-27 MHz) to a microscopic analysis of three parameters describing the collagen distribution (mean thickness and spacing of collagen bundles alon...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460602800103
更新日期:2006-01-01 00:00:00
abstract::Mathematical techniques are described for analyzing tongue shapes obtained with ultrasound images. The surface of the mid-sagittal section of the tongue was approximated by discrete points. In turn, these points were used to approximate position, slope and curvature of the tongue surface at a fixed time during speech....
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468400600104
更新日期:1984-01-01 00:00:00