Optical tracking of superficial dynamics from an acoustic radiation force-induced excitation.

Abstract:

:Acoustic radiation force (ARF) has become a common excitation mechanism in elasticity imaging. The high acoustic intensities and subsequent generation of harmonics, however, hamper the effectiveness of using conventional radiofrequency (rf) tracking to investigate the dynamics of tissues and catheter-based transducers, especially during the excitation. Optical tracking, on the other hand, does not utilize acoustic echo and thus is not affected by ARF-generated interference. Additionally, it is able to track equally well in two dimensions, something that rf tracking is unable to do. Despite the inherent near-field scattering that will likely preclude optical (i.e., visible spectrum) tracking from supplanting current ultrasound-based methods in a clinical setting, it could offer valuable new tools in the pursuit of a better understanding of ARF-induced dynamic responses. We utilized an optically-based method to track the dynamic response resulting from an ARF-induced excitation on the surface of a tissue-mimicking phantom and on an unbounded catheter. These tracking data were then compared to tracking data obtained from the conventional rf tracking method. Both impulsive and harmonic (i.e., amplitude-modulated) excitations were investigated. In general, there was good agreement between the conventional (i.e., ultrasound-based) and optically-based tracking methods. Disparities between displacement estimates from the two tracking methods is thought to be a result of the finite length of the tracking marker, which was assumed to move as an infinitesimal point, and aberration of reflected light due to surface waves. Given the reasonable agreement seen for the harmonic and impulsive excitation cases, an optical tracking method could be insightful in future investigations of tissue/transducer response to ARF-induced excitations in controlled experimental settings.

journal_name

Ultrason Imaging

journal_title

Ultrasonic imaging

authors

Bouchard RR,Van Soest G,Trahey GE,Van Der Steen AF

subject

Has Abstract

pub_date

2009-01-01 00:00:00

pages

17-30

issue

1

eissn

0161-7346

issn

1096-0910

journal_volume

31

pub_type

杂志文章
  • Skeletal Muscle Fatigue State Evaluation with Ultrasound Image Entropy.

    abstract::Muscle fatigue often occurs over a long period of exercise, and it can increase the risk of muscle injury. Evaluating the state of muscle fatigue can avoid unnecessary overtraining and injury of the muscle. Ultrasound imaging can non-invasively visualize muscle tissue in real-time. Image entropy is commonly used to ch...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734620952683

    authors: Li P,Yang X,Yin G,Guo J

    更新日期:2020-11-01 00:00:00

  • Transducer characterization from pressure amplitude distribution measurements using a Kalman filter as parameter estimation algorithm.

    abstract::The amplitude and frequency contents of a received ultrasound pulse depends on the spatial pressure amplitude distribution of the sound field, as produced by the transducer in the medium, and on the position and orientation of the reflecting surface in this field. Often, the geometry of the reflecting surface and the ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469001200405

    authors: Linssen FM,Hoeks AP

    更新日期:1990-10-01 00:00:00

  • Wavelet-based speckle noise reduction in ultrasound B-scan images.

    abstract::Speckle noise is known to be signal-dependent in ultrasound imaging. Hence, separating noise from signal becomes a difficult task. This paper describes a wavelet-based method for reducing speckle noise. We derive from the model of the displayed ultrasound image the optimal wavelet-domain filter in the least mean-squar...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460002200201

    authors: Rakotomamonjy A,Deforge P,Marché P

    更新日期:2000-04-01 00:00:00

  • A Review of Ultrasound Tissue Characterization with Mean Scatterer Spacing.

    abstract::Tissues exhibiting quasi-periodic structures can be modeled as a collection of diffuse scatterers and coherent scatterers. The mean scatterer spacing (MSS) of coherent and quasi-periodic components is directly related to tissue microstructure and has become an important quantitative ultrasound (QUS) parameter in the c...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章,评审

    doi:10.1177/0161734617692018

    authors: Zhou Z,Wu W,Wu S,Jia K,Tsui PH

    更新日期:2017-09-01 00:00:00

  • A comparison method for mean frequency estimators for Doppler ultrasound.

    abstract::Mean frequency estimators as used in pulsed Doppler ultrasound equipment should provide an accurate (quality) and consistent (robustness) estimate over a wide range of signal conditions. In a simplified signal model, the main parameters to consider are the noise level, mean frequency, bandwidth and power of both the D...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469201400404

    authors: Brands PJ,Hoeks AP

    更新日期:1992-10-01 00:00:00

  • Breast tissue classification using diagnostic ultrasound and pattern recognition techniques: II. Experimental results.

    abstract::The methods of statistical pattern recognition have been applied to the problem of in vivo ultrasonic characterization of breast disease in humans. Backscattered A-mode signals obtained from a commercial pulse imaging system were used to generate a large set of potentially useful features. Using statistical tests, a s...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468300500107

    authors: Finette S,Bleier AR,Swindell W,Haber K

    更新日期:1983-01-01 00:00:00

  • Feasibility exploration of blood flow estimation by contrast-assisted Nakagami imaging.

    abstract::The microbubble contrast agent destruction/replenishment technique has been widely applied to ultrasound-based blood flow estimation. The rate of increase of the time-intensity curve (TIC) due to microbubbles flowing into the region of interest as measured from B-mode images closely reflects the flow velocity. In this...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460803000301

    authors: Tsui PH,Yeh CK,Chang CC

    更新日期:2008-07-01 00:00:00

  • Acoustic Structure Quantification Analysis of the Thyroid in Patients with Diffuse Autoimmune Thyroid Disease.

    abstract::The aim of this study was to assess whether acoustic structure quantification (ASQ) can differentiate normal from pathological thyroid parenchyma in patients with diffuse autoimmune thyroid disease (AITD). We evaluated 83 subjects (72 [87%] women and 11 [13%] men) aged 19 to 94 years with a mean age of 53 years. We pe...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615580766

    authors: Zandieh S,Bernt R,Zwerina J,Haller J,Knoll P,Seyeddain O,Mirzaei S

    更新日期:2016-03-01 00:00:00

  • Compressed Sensing for Elastography in Portable Ultrasound.

    abstract::Portable ultrasound is recently emerging as a new medical imaging modality featuring high portability, easy connectivity, and real-time on-site diagnostic ability. However, it does not yet provide ultrasound elastography function that enables the diagnosis of malignant lesions using elastic properties. This is mainly ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734617716938

    authors: Shin B,Jeon S,Ryu J,Kwon HJ

    更新日期:2017-11-01 00:00:00

  • Observations of tissue response to acoustic radiation force: opportunities for imaging.

    abstract::Acoustic Radiation Force Impulse (ARFI) imaging is a method for characterizing local variations in tissue mechanical properties. In this method, a single ultrasonic transducer array is used to both apply temporally short localized radiation forces within tissue and to track the resulting displacements through time. In...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460202400301

    authors: Nightingale K,Bentley R,Trahey G

    更新日期:2002-07-01 00:00:00

  • Volumetric Hall effect tomography--a feasibility study.

    abstract::Hall effect imaging is an ultrasound-based method of mapping spatial variations in the dielectric constants of an acoustically-uniform sample. This paper presents three-dimensional Hall effect images of phantoms obtained by scanning a single transducer across a two-dimensional grid, effectively simulating two-dimensio...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469902100303

    authors: Wen H

    更新日期:1999-07-01 00:00:00

  • Computerized ultrasound B-scan texture analysis of experimental fatty liver disease: influence of total lipid content and fat deposit distribution.

    abstract::Statistical pattern recognition procedures allow a quantitative description of ultrasound-B-scan image texture. According to well-established animal models, different types of fatty liver disease were induced in female Wistar rats. For the correlation of the computerized ultrasound image with its underlying histology ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469001200302

    authors: Layer G,Zuna I,Lorenz A,Zerban H,Haberkorn U,Bannasch P,van Kaick G,Räth U

    更新日期:1990-07-01 00:00:00

  • Classification of scattering objects by regular arrays of scatterers using Fourier analysis.

    abstract::For a class of scattering objects the mean separation between the scatterers is determined. Over a range of frequencies, ultrasonic back-scattered pressure signals are recorded. It is suggested to derive the mean spacing of an unknown scattering object by employing Fourier analysis and comparing the signal with signal...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468300500405

    authors: Koch I

    更新日期:1983-10-01 00:00:00

  • Improved Fourier-transform-based parallel receive beam formation.

    abstract::A Fourier transform (FT)-based technique for forming parallel receive beams has been previously employed to increase the imaging frame rate in ultrasonic imaging. However, the image quality in FT-based parallel reconstruction is degraded because differences in range focusing delays are ignored and a wide transmit beam...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460302500201

    authors: Li ML,Li PC

    更新日期:2003-04-01 00:00:00

  • Statistical relationship between ultrasound echo envelope and envelope peak.

    abstract::This study shows that the amplitude information of ultrasound echoes is carried mainly by the envelope peaks (EPs). It is first shown that the EPs in an A-line represent the maximum number of independent amplitude data. It is then demonstrated that the entire envelope could be approximately reconstructed from the EPs....

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468801000403

    authors: He P

    更新日期:1988-10-01 00:00:00

  • Diffraction tomography using arbitrary transmitter and receiver surfaces.

    abstract::The theory of diffraction tomography for two-dimensional objects within the Born approximation is presented for cases where the scattered field is measured over arbitrarily shaped boundaries surrounding the object. Reconstruction algorithms are presented for both plane wave (parallel beam) and cylindrical wave (fan be...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468400600207

    authors: Devaney AJ,Beylkin G

    更新日期:1984-04-01 00:00:00

  • A Variance-reduction Approach to Detection of the Thyroid-nodule Boundary on Ultrasound Images.

    abstract::To perform computer-aided diagnosis of the thyroid nodules on ultrasound images, the location and boundary of nodules should be clearly defined. However, the identification of thyroid nodule boundary is a difficult issue due to the biological characteristics of the nodules, the physics and quality of ultrasound imagin...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734619839648

    authors: Chiu LY,Chen A

    更新日期:2019-07-01 00:00:00

  • Autoregressive spectral estimation in ultrasonic scatterer size imaging.

    abstract::An autoregressive (AR) spectral estimation method was considered for the purpose of estimating scatterer size images. The variance and bias of the resulting estimates were compared with those using classical FFT periodograms for a range of input signal-to-noise ratios and echo-signal durations corresponding to various...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469601800102

    authors: Chaturvedi P,Insana MF

    更新日期:1996-01-01 00:00:00

  • Adaptive imaging using an optimal receive aperture size.

    abstract::Sidelobe contribution from off-axis targets degrades image quality in a coherent array imaging system. In ultrasound imaging, focusing errors resulting from sound-velocity inhomogeneities in human tissue--also known as phase aberrations reduce the coherence of the received signals and elevate the sidelobe level. This ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460502700205

    authors: Li ML,Huang SW,Ustüner K,Li PC

    更新日期:2005-04-01 00:00:00

  • GPU-accelerated Kernel Regression Reconstruction for Freehand 3D Ultrasound Imaging.

    abstract::Volume reconstruction method plays an important role in improving reconstructed volumetric image quality for freehand three-dimensional (3D) ultrasound imaging. By utilizing the capability of programmable graphics processing unit (GPU), we can achieve a real-time incremental volume reconstruction at a speed of 25-50 f...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734616689464

    authors: Wen T,Li L,Zhu Q,Qin W,Gu J,Yang F,Xie Y

    更新日期:2017-07-01 00:00:00

  • Digital simulation of pulsed ultrasonic waveforms.

    abstract::When modeling or simulating an ultrasonic pulse-echo system it is necessary to know the transducer waveforms that are the input to the system. In general, accurate transducer modeling is complex and waveform calculation is computationally intensive. Because of this, investigators often assume these waveforms to be sim...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468700900405

    authors: Barber FE,Goodsitt MM

    更新日期:1987-10-01 00:00:00

  • A method for in vitro mapping of ultrasonic speed and density in breast tissue.

    abstract::A method has been developed for mapping density and ultrasonic speed in 1 mm thick slices of soft tissue with a resolution of about 1 mm. Tests using phantom sections have verified the accuracy and resolution of the ultrasonic speed maps. The method has been applied to breast tissues of three patients including tumors...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469101300105

    authors: Yang JN,Murphy AD,Madsen EL,Zagzebski JA,Gilchrist KW,Frank GR,Macdonald MC,Millard CA,Faraggi A,Jaramillo CA

    更新日期:1991-01-01 00:00:00

  • Variance and covariance of accumulated displacement estimates.

    abstract::Tracking large deformations in tissue using ultrasound can enable the reconstruction of nonlinear elastic parameters, but poses a challenge to displacement estimation algorithms. Such large deformations have to be broken up into steps, each of which contributes an estimation error to the final accumulated displacement...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734613479246

    authors: Bayer M,Hall TJ

    更新日期:2013-04-01 00:00:00

  • Toward Noninvasive Mapping of Diffuse Scattering in the Presence of Motion.

    abstract::Ultrasonic coda wave analysis techniques localize defects in fields such as seismography and nondestructive testing. In medical ultrasound, these techniques might provide novel mapping of tissue properties in diseases characterized by local fibrosis. In this work, we present an approach for localizing variation in sca...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734619899885

    authors: Lindsey BD,Collins GC

    更新日期:2020-01-01 00:00:00

  • A quantitative approach to speckle reduction via frequency compounding.

    abstract::Coherent speckle is a source of image noise in ultrasonic B-mode imaging. The use of multiple imaging frequencies has been suggested as a technique for speckle contrast reduction. This technique involves the averaging of images whose speckle patterns have been modified by a change in the spectrum of the transmitted or...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468600800301

    authors: Trahey GE,Allison JW,Smith SW,von Ramm OT

    更新日期:1986-07-01 00:00:00

  • In vivo study of online liver tissue classification based on envelope power spectrum analysis.

    abstract::An ultrasonic imaging and signal analysis system, combining a 3.5 MHz linear array B-scanner and an array processor, has been realized for a clinical liver tissue classification study. Based on the complete unprocessed rf data set of a real time B-image, local envelope power spectra averaged over interactively defined...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469401600202

    authors: Lang M,Ermert H,Heuser L

    更新日期:1994-04-01 00:00:00

  • A scalable architecture for real-time synthetic-focus imaging.

    abstract::A scalable architecture for forming real-time synthetic focus images is described and the design of a 256-channel system using currently-available technology is presented as an example implementation of the architecture. The parallelism of the system scales directly with the number of array elements and the image comp...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460302500303

    authors: Richard WD

    更新日期:2003-07-01 00:00:00

  • Linear arrays for vibro-acoustography: a numerical simulation study.

    abstract::In this work, we study linear array beamforming for vibro-acoustography systems. The goal of this research is to assess the feasibility of vibro-acoustography imaging systems based on linear arrays for clinical applications. The vibro-acoustography transducer is designed with two arrays driven by two continuous-wave o...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460402600101

    authors: Silva GT,Greenleaf JF,Fatemi M

    更新日期:2004-01-01 00:00:00

  • Subharmonic contrast microbubble signals for noninvasive pressure estimation under static and dynamic flow conditions.

    abstract::Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled co...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173461103300301

    authors: Halldorsdottir VG,Dave JK,Leodore LM,Eisenbrey JR,Park S,Hall AL,Thomenius K,Forsberg F

    更新日期:2011-07-01 00:00:00

  • An efficient motion estimation and compensation method for ultrasound synthetic aperture imaging.

    abstract::This paper describes a method for overcoming motion artifacts in synthetic aperture imaging. The method is based on a computer simulation study on the influence of target motion on synthetic aperture techniques. A region-based motion compensation approach is used in which only the axial motion is estimated and compens...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460202400202

    authors: Kim KS,Hwang JS,Jeong JS,Song TK

    更新日期:2002-04-01 00:00:00