Abstract:
:Speckle noise is known to be signal-dependent in ultrasound imaging. Hence, separating noise from signal becomes a difficult task. This paper describes a wavelet-based method for reducing speckle noise. We derive from the model of the displayed ultrasound image the optimal wavelet-domain filter in the least mean-square sense. Simulations on synthetic data have been carried out in order to assess the performance of the proposed filter with regards to the classical wavelet shrinkage scheme, while phantom and tissue images have been used for testing it on real data. The results show that the filter effectively reduces the speckle noise while preserving resolvable details.
journal_name
Ultrason Imagingjournal_title
Ultrasonic imagingauthors
Rakotomamonjy A,Deforge P,Marché Pdoi
10.1177/016173460002200201subject
Has Abstractpub_date
2000-04-01 00:00:00pages
73-94issue
2eissn
0161-7346issn
1096-0910journal_volume
22pub_type
杂志文章abstract::Optimal transmit phasing has been proposed to increase contrast-to-tissue ratio (CTR) by relatively phasing the tissue and leakage harmonic components to cancel each other out for tissue-background suppression in harmonic imaging. Since most clinical systems are only equipped with a bipolar square-wave pulser, effecti...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173461003200103
更新日期:2010-01-01 00:00:00
abstract::Tracking large deformations in tissue using ultrasound can enable the reconstruction of nonlinear elastic parameters, but poses a challenge to displacement estimation algorithms. Such large deformations have to be broken up into steps, each of which contributes an estimation error to the final accumulated displacement...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734613479246
更新日期:2013-04-01 00:00:00
abstract::Statistical pattern recognition procedures allow a quantitative description of ultrasound-B-scan image texture. According to well-established animal models, different types of fatty liver disease were induced in female Wistar rats. For the correlation of the computerized ultrasound image with its underlying histology ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469001200302
更新日期:1990-07-01 00:00:00
abstract::To perform computer-aided diagnosis of the thyroid nodules on ultrasound images, the location and boundary of nodules should be clearly defined. However, the identification of thyroid nodule boundary is a difficult issue due to the biological characteristics of the nodules, the physics and quality of ultrasound imagin...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734619839648
更新日期:2019-07-01 00:00:00
abstract::Computer texture analysis methods use texture features that are traditionally chosen from a large set of fixed features known in literature. These fixed features are often not specifically designed to the problem at hand, and as a result they may have low discriminative power, and/or may be correlated. Increasing the ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章,评审
doi:10.1177/016173469802000204
更新日期:1998-04-01 00:00:00
abstract::It may be possible to diagnose and monitor scarring, inflammation and edema in transplant kidney using reconstructive ultrasound elasticity imaging. Kidney elasticity is expected to change dramatically with scar, and to a lesser degree, with acute inflammation and edema. The hypothesis that changes in kidney elasticit...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460002200303
更新日期:2000-07-01 00:00:00
abstract::In this paper, quantitative tomographic reconstructions of biological tissue are presented. First, the experimental setup and a hybrid filtered backpropagation (FBP) technique are briefly described. Using this technique, which includes exact backpropagation of data prior to reconstruction by means of the classical FBP...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469401600102
更新日期:1994-01-01 00:00:00
abstract::Muscle fatigue often occurs over a long period of exercise, and it can increase the risk of muscle injury. Evaluating the state of muscle fatigue can avoid unnecessary overtraining and injury of the muscle. Ultrasound imaging can non-invasively visualize muscle tissue in real-time. Image entropy is commonly used to ch...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734620952683
更新日期:2020-11-01 00:00:00
abstract::Mean frequency estimators as used in pulsed Doppler ultrasound equipment should provide an accurate (quality) and consistent (robustness) estimate over a wide range of signal conditions. In a simplified signal model, the main parameters to consider are the noise level, mean frequency, bandwidth and power of both the D...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469201400404
更新日期:1992-10-01 00:00:00
abstract::Tissues exhibiting quasi-periodic structures can be modeled as a collection of diffuse scatterers and coherent scatterers. The mean scatterer spacing (MSS) of coherent and quasi-periodic components is directly related to tissue microstructure and has become an important quantitative ultrasound (QUS) parameter in the c...
journal_title:Ultrasonic imaging
pub_type: 杂志文章,评审
doi:10.1177/0161734617692018
更新日期:2017-09-01 00:00:00
abstract::Experimental work using a quantitative C-scan technique to measure in situ enhancement of hepatic backscatter resulting from the administration of gelatin microspheres to dogs is reported. We have found that reproducible enhancement of hepatic backscatter on the order of 2 dB followed the peripheral administration of ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468500700402
更新日期:1985-10-01 00:00:00
abstract::Attenuation measurements of various tissue mimicking phantoms and three different groups of patients were obtained using a modified commercial sector scanner. Estimates of attenuation were made using the spectral shift method with mean frequencies at different depths of a region of interest being obtained by both zero...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468400600402
更新日期:1984-10-01 00:00:00
abstract::Modern ultrasound Doppler systems are facing the problem of processing increasingly shorter data sets. Spectral analysis of the strongly nonstationary Doppler signal needs to shorten the analysis window while maintaining a low variance and high resolution spectrum. Color flow imaging requires estimation of the Doppler...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469501700101
更新日期:1995-01-01 00:00:00
abstract::Accurate tracking of tissue motion is critically important for several ultrasound elastography methods. In this study, we investigate the feasibility of using three published convolution neural network (CNN) models built for optical flow (hereafter referred to as CNN-based tracking) by the computer vision community fo...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734620902527
更新日期:2020-03-01 00:00:00
abstract::For a class of scattering objects the mean separation between the scatterers is determined. Over a range of frequencies, ultrasonic back-scattered pressure signals are recorded. It is suggested to derive the mean spacing of an unknown scattering object by employing Fourier analysis and comparing the signal with signal...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468300500405
更新日期:1983-10-01 00:00:00
abstract::Acoustic form factors have been used to model the frequency dependence of acoustic scattering in phantoms and tissues. This work demonstrates that a broad range of scatterer sizes, individually well represented by Faran theory or a Gaussian form factor, is not accurately described by a single effective scatterer from ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734614534399
更新日期:2015-01-01 00:00:00
abstract::Breast ultrasound (BUS) imaging has become a crucial modality, especially for providing a complementary view when other modalities (i.e., mammography) are not conclusive in the task of assessing lesions. The specificity in cancer detection using BUS imaging is low. These false-positive findings often lead to an increa...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615589287
更新日期:2016-05-01 00:00:00
abstract::Ultrasonic coda wave analysis techniques localize defects in fields such as seismography and nondestructive testing. In medical ultrasound, these techniques might provide novel mapping of tissue properties in diseases characterized by local fibrosis. In this work, we present an approach for localizing variation in sca...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734619899885
更新日期:2020-01-01 00:00:00
abstract::Transesophageal echocardiography (TEE) is an essential diagnostic tool in patients with poor transthoracic echocardiographic windows or when detailed imaging of structures distant from the chest wall is necessary. A real-time 3D TEE probe has been fabricated in our laboratory in order to increase the amount of informa...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460402600402
更新日期:2004-10-01 00:00:00
abstract::Time reversal of ultrasonic field allows a very efficient approach to focusing pulsed ultrasonic waves through lossless inhomogeneous media. Time reversal mirrors (TRM) are made of large transducer arrays, allowing the incident acoustic field to be sampled, time reversed and re-emitted. Time reversal processing permit...
journal_title:Ultrasonic imaging
pub_type: 杂志文章,评审
doi:10.1177/016173469601800202
更新日期:1996-04-01 00:00:00
abstract::The theory of diffraction tomography for two-dimensional objects within the Born approximation is presented for cases where the scattered field is measured over arbitrarily shaped boundaries surrounding the object. Reconstruction algorithms are presented for both plane wave (parallel beam) and cylindrical wave (fan be...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468400600207
更新日期:1984-04-01 00:00:00
abstract::This paper addresses significant sources of electromagnetic noise in Hall effect imaging. Hall effect imaging employs large electrical pulses for signal generation and high sensitivity ultrasonic probes for signal reception. Coherent noise arises through various coupling mechanisms between the excitation pulse and the...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469802000305
更新日期:1998-07-01 00:00:00
abstract::Sidelobe contribution from off-axis targets degrades image quality in a coherent array imaging system. In ultrasound imaging, focusing errors resulting from sound-velocity inhomogeneities in human tissue--also known as phase aberrations reduce the coherence of the received signals and elevate the sidelobe level. This ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460502700205
更新日期:2005-04-01 00:00:00
abstract::The liver has been hypothesized to have a unique arrangement of microvasculature that presents as an arrangement of quasiperiodic scatterers to an interrogating ultrasound pulse. The mean scatterer spacing (MSS) of these quasiperiodic scatterers has been proposed as a useful quantitative ultrasound biomarker for chara...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734613511232
更新日期:2014-04-01 00:00:00
abstract::Peripheral artery disease is often asymptomatic, and various imaging and nonimaging techniques have been used for assessment and monitoring treatments. This study is designed to demonstrate the ability of photoacoustic imaging to noninvasively determine changes in tissue oxygenation that occur in mice's hind limb skel...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734619862287
更新日期:2019-09-01 00:00:00
abstract::In pulsed Doppler ultrasound systems, the ultrasound radiofrequency (RF) signals received can be employed to estimate noninvasively the time-dependent blood velocity distribution within and artery. The RF signals are composed of signals originating from clutter (e.g., vessel walls) and scatterers (e.g., red blood cell...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469701900101
更新日期:1997-01-01 00:00:00
abstract::Acoustic Radiation Force Impulse (ARFI) imaging is a method for characterizing local variations in tissue mechanical properties. In this method, a single ultrasonic transducer array is used to both apply temporally short localized radiation forces within tissue and to track the resulting displacements through time. In...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460202400301
更新日期:2002-07-01 00:00:00
abstract::Coherent speckle is a source of image noise in ultrasonic B-mode imaging. The use of multiple imaging frequencies has been suggested as a technique for speckle contrast reduction. This technique involves the averaging of images whose speckle patterns have been modified by a change in the spectrum of the transmitted or...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468600800301
更新日期:1986-07-01 00:00:00
abstract::This study shows that the amplitude information of ultrasound echoes is carried mainly by the envelope peaks (EPs). It is first shown that the EPs in an A-line represent the maximum number of independent amplitude data. It is then demonstrated that the entire envelope could be approximately reconstructed from the EPs....
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468801000403
更新日期:1988-10-01 00:00:00
abstract::Behavior and limitations of the sinc basis method have been discovered during simulation studies. An iterative row-action method (ART) is compared with a full-matrix, least-squares solution (QR decomposition) and the problem of multiple solutions is discussed. Knowledge of the spatial distribution of scattered field e...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468901100103
更新日期:1989-01-01 00:00:00