Abstract:
:The microbubble contrast agent destruction/replenishment technique has been widely applied to ultrasound-based blood flow estimation. The rate of increase of the time-intensity curve (TIC) due to microbubbles flowing into the region of interest as measured from B-mode images closely reflects the flow velocity. In this study, we monitored microbubble replenishment by a proposed new approach called the time-Nakagami-parameter curve (TNC) obtained from Nakagami-parameter images for quantifying the flow velocity. The feasibility of using the TNC to estimate the flow was evaluated in computer simulations of the TIC and TNC for flow velocities from 10 to 30 cm/s under an ultrasound frequency of 5 MHz. The clutter effects on the TIC and TNC were explored in amore realistic situation by carrying out phantom measurements of 25 MHz. The rates of increase of the TIC and TNC were expressed by the rate constants beta1 and betaN of a monoexponential model, respectively. The average beta1 increased from 38 to 110 s(-1) as the flow velocity increased from 10 to 30 cm/s (r = 0.98), and the average betaN increased from approximately 40 to 120 s(-1) for the same increase in flow velocity (r = 0.98). The p-value between the results of beta1 and betaN as a function of flow velocity was 0.77. These results represent that betaN quantifies the flow velocity similarly to the conventional beta1. In particular, both the simulation and experimental results revealed that the TNC method conditionally tolerates the presence of nonperfused areas (e.g., surrounding tissues or vessel walls) in the region of interest without requiring application of an additional wall filter to cancel the influences of clutter echoes on the flow estimation. These findings suggest that the TNC-based technique may be a potential method as a complementary tool for the conventional TIC technique to improve the estimation of blood flow.
journal_name
Ultrason Imagingjournal_title
Ultrasonic imagingauthors
Tsui PH,Yeh CK,Chang CCdoi
10.1177/016173460803000301subject
Has Abstractpub_date
2008-07-01 00:00:00pages
133-50issue
3eissn
0161-7346issn
1096-0910journal_volume
30pub_type
杂志文章abstract::In medical ultrasound imaging, two-dimensional (2-D) array transducers are desirable to implement dynamic focusing and phase aberration correction in two dimensions as well as volumetric imaging. Unfortunately, the small size of a 2-D array element results in a small clamped capacitance and a large electrical impedanc...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469501700202
更新日期:1995-04-01 00:00:00
abstract::The propagation of pressure pulses of arbitrary time form in inhomogeneous attenuating media with characteristics similar to real biological tissues is considered. A mathematical model using the quasi-optical approximation is developed to solve the wave equation. Such a model proves to be convenient for computer reali...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469301500106
更新日期:1993-01-01 00:00:00
abstract::This study shows that the amplitude information of ultrasound echoes is carried mainly by the envelope peaks (EPs). It is first shown that the EPs in an A-line represent the maximum number of independent amplitude data. It is then demonstrated that the entire envelope could be approximately reconstructed from the EPs....
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468801000403
更新日期:1988-10-01 00:00:00
abstract::Sidelobe contribution from off-axis targets degrades image quality in a coherent array imaging system. In ultrasound imaging, focusing errors resulting from sound-velocity inhomogeneities in human tissue--also known as phase aberrations reduce the coherence of the received signals and elevate the sidelobe level. This ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460502700205
更新日期:2005-04-01 00:00:00
abstract::When modeling or simulating an ultrasonic pulse-echo system it is necessary to know the transducer waveforms that are the input to the system. In general, accurate transducer modeling is complex and waveform calculation is computationally intensive. Because of this, investigators often assume these waveforms to be sim...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468700900405
更新日期:1987-10-01 00:00:00
abstract::A scalable architecture for forming real-time synthetic focus images is described and the design of a 256-channel system using currently-available technology is presented as an example implementation of the architecture. The parallelism of the system scales directly with the number of array elements and the image comp...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460302500303
更新日期:2003-07-01 00:00:00
abstract::Hall effect imaging is an ultrasound-based method of mapping spatial variations in the dielectric constants of an acoustically-uniform sample. This paper presents three-dimensional Hall effect images of phantoms obtained by scanning a single transducer across a two-dimensional grid, effectively simulating two-dimensio...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469902100303
更新日期:1999-07-01 00:00:00
abstract::Volume reconstruction method plays an important role in improving reconstructed volumetric image quality for freehand three-dimensional (3D) ultrasound imaging. By utilizing the capability of programmable graphics processing unit (GPU), we can achieve a real-time incremental volume reconstruction at a speed of 25-50 f...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734616689464
更新日期:2017-07-01 00:00:00
abstract::Speckle noise is known to be signal-dependent in ultrasound imaging. Hence, separating noise from signal becomes a difficult task. This paper describes a wavelet-based method for reducing speckle noise. We derive from the model of the displayed ultrasound image the optimal wavelet-domain filter in the least mean-squar...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460002200201
更新日期:2000-04-01 00:00:00
abstract::The aim of this study was to assess whether acoustic structure quantification (ASQ) can differentiate normal from pathological thyroid parenchyma in patients with diffuse autoimmune thyroid disease (AITD). We evaluated 83 subjects (72 [87%] women and 11 [13%] men) aged 19 to 94 years with a mean age of 53 years. We pe...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615580766
更新日期:2016-03-01 00:00:00
abstract::In this paper, quantitative tomographic reconstructions of biological tissue are presented. First, the experimental setup and a hybrid filtered backpropagation (FBP) technique are briefly described. Using this technique, which includes exact backpropagation of data prior to reconstruction by means of the classical FBP...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469401600102
更新日期:1994-01-01 00:00:00
abstract::Optimal transmit phasing has been proposed to increase contrast-to-tissue ratio (CTR) by relatively phasing the tissue and leakage harmonic components to cancel each other out for tissue-background suppression in harmonic imaging. Since most clinical systems are only equipped with a bipolar square-wave pulser, effecti...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173461003200103
更新日期:2010-01-01 00:00:00
abstract::Global and local attenuation coefficient estimations were performed in a phantom using a pulse echo method based on the rate of decay of zero crossing density. Focussed and unfocussed 3.5 MHz transducers were used. It was found that good global estimates could be made with either transducer over a 2:1 range of attenua...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468500700202
更新日期:1985-04-01 00:00:00
abstract::In pulsed Doppler ultrasound systems, the ultrasound radiofrequency (RF) signals received can be employed to estimate noninvasively the time-dependent blood velocity distribution within and artery. The RF signals are composed of signals originating from clutter (e.g., vessel walls) and scatterers (e.g., red blood cell...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469701900101
更新日期:1997-01-01 00:00:00
abstract::Acoustic radiation force (ARF) has become a common excitation mechanism in elasticity imaging. The high acoustic intensities and subsequent generation of harmonics, however, hamper the effectiveness of using conventional radiofrequency (rf) tracking to investigate the dynamics of tissues and catheter-based transducers...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:
更新日期:2009-01-01 00:00:00
abstract::The amplitude and frequency contents of a received ultrasound pulse depends on the spatial pressure amplitude distribution of the sound field, as produced by the transducer in the medium, and on the position and orientation of the reflecting surface in this field. Often, the geometry of the reflecting surface and the ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469001200405
更新日期:1990-10-01 00:00:00
abstract::To perform computer-aided diagnosis of the thyroid nodules on ultrasound images, the location and boundary of nodules should be clearly defined. However, the identification of thyroid nodule boundary is a difficult issue due to the biological characteristics of the nodules, the physics and quality of ultrasound imagin...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734619839648
更新日期:2019-07-01 00:00:00
abstract::In recent years, adaptive minimum-variance (MV) beamforming has been successfully applied to medical ultrasound imaging, resulting in simultaneous improvement in imaging resolution and contrast. MV has high resolution and hence can provide accurate estimates of the target locations. However, the MV amplitude estimates...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615600167
更新日期:2016-07-01 00:00:00
abstract::A new online signal processing technique is described to reduce speckle noise in ultrasound images. In the imaging system, a focused piston transducer is divided into thirty-two sectors. In the receive mode, parallel signal processing arranges the sectors into eight maltese crosses. The rf signals of the perpendicular...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468801000301
更新日期:1988-07-01 00:00:00
abstract::Tracking large deformations in tissue using ultrasound can enable the reconstruction of nonlinear elastic parameters, but poses a challenge to displacement estimation algorithms. Such large deformations have to be broken up into steps, each of which contributes an estimation error to the final accumulated displacement...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734613479246
更新日期:2013-04-01 00:00:00
abstract::Acoustic form factors have been used to model the frequency dependence of acoustic scattering in phantoms and tissues. This work demonstrates that a broad range of scatterer sizes, individually well represented by Faran theory or a Gaussian form factor, is not accurately described by a single effective scatterer from ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734614534399
更新日期:2015-01-01 00:00:00
abstract::Peripheral artery disease is often asymptomatic, and various imaging and nonimaging techniques have been used for assessment and monitoring treatments. This study is designed to demonstrate the ability of photoacoustic imaging to noninvasively determine changes in tissue oxygenation that occur in mice's hind limb skel...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734619862287
更新日期:2019-09-01 00:00:00
abstract::Muscle fatigue often occurs over a long period of exercise, and it can increase the risk of muscle injury. Evaluating the state of muscle fatigue can avoid unnecessary overtraining and injury of the muscle. Ultrasound imaging can non-invasively visualize muscle tissue in real-time. Image entropy is commonly used to ch...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734620952683
更新日期:2020-11-01 00:00:00
abstract::Mean frequency estimators as used in pulsed Doppler ultrasound equipment should provide an accurate (quality) and consistent (robustness) estimate over a wide range of signal conditions. In a simplified signal model, the main parameters to consider are the noise level, mean frequency, bandwidth and power of both the D...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469201400404
更新日期:1992-10-01 00:00:00
abstract::Behavior and limitations of the sinc basis method have been discovered during simulation studies. An iterative row-action method (ART) is compared with a full-matrix, least-squares solution (QR decomposition) and the problem of multiple solutions is discussed. Knowledge of the spatial distribution of scattered field e...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468901100103
更新日期:1989-01-01 00:00:00
abstract::Accurate tracking of tissue motion is critically important for several ultrasound elastography methods. In this study, we investigate the feasibility of using three published convolution neural network (CNN) models built for optical flow (hereafter referred to as CNN-based tracking) by the computer vision community fo...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734620902527
更新日期:2020-03-01 00:00:00
abstract::A Fourier transform (FT)-based technique for forming parallel receive beams has been previously employed to increase the imaging frame rate in ultrasonic imaging. However, the image quality in FT-based parallel reconstruction is degraded because differences in range focusing delays are ignored and a wide transmit beam...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460302500201
更新日期:2003-04-01 00:00:00
abstract::Mathematical techniques are described for analyzing tongue shapes obtained with ultrasound images. The surface of the mid-sagittal section of the tongue was approximated by discrete points. In turn, these points were used to approximate position, slope and curvature of the tongue surface at a fixed time during speech....
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468400600104
更新日期:1984-01-01 00:00:00
abstract::Most methods for in vivo quantitation of ultrasound attenuation and backscatter are not available clinically because they rely upon acquiring and analyzing radio frequency (rf) echo signals. This paper describes a technique to estimate ultrasound attenuation and backscatter from B-mode image data. The video signal ana...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469701900305
更新日期:1997-07-01 00:00:00
abstract::Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled co...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173461103300301
更新日期:2011-07-01 00:00:00