Feasibility exploration of blood flow estimation by contrast-assisted Nakagami imaging.

Abstract:

:The microbubble contrast agent destruction/replenishment technique has been widely applied to ultrasound-based blood flow estimation. The rate of increase of the time-intensity curve (TIC) due to microbubbles flowing into the region of interest as measured from B-mode images closely reflects the flow velocity. In this study, we monitored microbubble replenishment by a proposed new approach called the time-Nakagami-parameter curve (TNC) obtained from Nakagami-parameter images for quantifying the flow velocity. The feasibility of using the TNC to estimate the flow was evaluated in computer simulations of the TIC and TNC for flow velocities from 10 to 30 cm/s under an ultrasound frequency of 5 MHz. The clutter effects on the TIC and TNC were explored in amore realistic situation by carrying out phantom measurements of 25 MHz. The rates of increase of the TIC and TNC were expressed by the rate constants beta1 and betaN of a monoexponential model, respectively. The average beta1 increased from 38 to 110 s(-1) as the flow velocity increased from 10 to 30 cm/s (r = 0.98), and the average betaN increased from approximately 40 to 120 s(-1) for the same increase in flow velocity (r = 0.98). The p-value between the results of beta1 and betaN as a function of flow velocity was 0.77. These results represent that betaN quantifies the flow velocity similarly to the conventional beta1. In particular, both the simulation and experimental results revealed that the TNC method conditionally tolerates the presence of nonperfused areas (e.g., surrounding tissues or vessel walls) in the region of interest without requiring application of an additional wall filter to cancel the influences of clutter echoes on the flow estimation. These findings suggest that the TNC-based technique may be a potential method as a complementary tool for the conventional TIC technique to improve the estimation of blood flow.

journal_name

Ultrason Imaging

journal_title

Ultrasonic imaging

authors

Tsui PH,Yeh CK,Chang CC

doi

10.1177/016173460803000301

subject

Has Abstract

pub_date

2008-07-01 00:00:00

pages

133-50

issue

3

eissn

0161-7346

issn

1096-0910

journal_volume

30

pub_type

杂志文章
  • Wavelet-based speckle noise reduction in ultrasound B-scan images.

    abstract::Speckle noise is known to be signal-dependent in ultrasound imaging. Hence, separating noise from signal becomes a difficult task. This paper describes a wavelet-based method for reducing speckle noise. We derive from the model of the displayed ultrasound image the optimal wavelet-domain filter in the least mean-squar...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460002200201

    authors: Rakotomamonjy A,Deforge P,Marché P

    更新日期:2000-04-01 00:00:00

  • Mathematical simulation of pressure pulse propagation in biological tissues.

    abstract::The propagation of pressure pulses of arbitrary time form in inhomogeneous attenuating media with characteristics similar to real biological tissues is considered. A mathematical model using the quasi-optical approximation is developed to solve the wave equation. Such a model proves to be convenient for computer reali...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469301500106

    authors: Adrov VN,Chernomordik VV

    更新日期:1993-01-01 00:00:00

  • Experimental Validation of ARFI Surveillance of Subcutaneous Hemorrhage (ASSH) Using Calibrated Infusions in a Tissue-Mimicking Model and Dogs.

    abstract::Acoustic radiation force impulse (ARFI) Surveillance of Subcutaneous Hemorrhage (ASSH) has been previously demonstrated to differentiate bleeding phenotype and responses to therapy in dogs and humans, but to date, the method has lacked experimental validation. This work explores experimental validation of ASSH in a po...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615617940

    authors: Geist RE,DuBois CH,Nichols TC,Caughey MC,Merricks EP,Raymer R,Gallippi CM

    更新日期:2016-09-01 00:00:00

  • An efficient motion estimation and compensation method for ultrasound synthetic aperture imaging.

    abstract::This paper describes a method for overcoming motion artifacts in synthetic aperture imaging. The method is based on a computer simulation study on the influence of target motion on synthetic aperture techniques. A region-based motion compensation approach is used in which only the axial motion is estimated and compens...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460202400202

    authors: Kim KS,Hwang JS,Jeong JS,Song TK

    更新日期:2002-04-01 00:00:00

  • Reconstructive ultrasound elasticity imaging for renal transplant diagnosis: kidney ex vivo results.

    abstract::It may be possible to diagnose and monitor scarring, inflammation and edema in transplant kidney using reconstructive ultrasound elasticity imaging. Kidney elasticity is expected to change dramatically with scar, and to a lesser degree, with acute inflammation and edema. The hypothesis that changes in kidney elasticit...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460002200303

    authors: Emelianov SY,Lubinski MA,Skovoroda AR,Erkamp RQ,Leavey SF,Wiggins RC,O'Donnell M

    更新日期:2000-07-01 00:00:00

  • Breast-lesion Segmentation Combining B-Mode and Elastography Ultrasound.

    abstract::Breast ultrasound (BUS) imaging has become a crucial modality, especially for providing a complementary view when other modalities (i.e., mammography) are not conclusive in the task of assessing lesions. The specificity in cancer detection using BUS imaging is low. These false-positive findings often lead to an increa...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615589287

    authors: Pons G,Martí J,Martí R,Ganau S,Noble JA

    更新日期:2016-05-01 00:00:00

  • A scalable architecture for real-time synthetic-focus imaging.

    abstract::A scalable architecture for forming real-time synthetic focus images is described and the design of a 256-channel system using currently-available technology is presented as an example implementation of the architecture. The parallelism of the system scales directly with the number of array elements and the image comp...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460302500303

    authors: Richard WD

    更新日期:2003-07-01 00:00:00

  • Deconvolution of in-vivo ultrasound B-mode images.

    abstract::An algorithm for deconvolution of medical ultrasound images is presented. The procedure involves estimation of the basic one-dimensional ultrasound pulse, determining the ratio of the covariance of the noise to the covariance of the reflection signal, and finally deconvolution of the rf signal from the transducer. Usi...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469301500204

    authors: Jensen JA,Mathorne J,Gravesen T,Stage B

    更新日期:1993-04-01 00:00:00

  • Attenuation estimation with the zero-crossing technique: phantom studies.

    abstract::Global and local attenuation coefficient estimations were performed in a phantom using a pulse echo method based on the rate of decay of zero crossing density. Focussed and unfocussed 3.5 MHz transducers were used. It was found that good global estimates could be made with either transducer over a 2:1 range of attenua...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468500700202

    authors: Ophir J,Ghouse MA,Ferrari LA

    更新日期:1985-04-01 00:00:00

  • Adaptive imaging using an optimal receive aperture size.

    abstract::Sidelobe contribution from off-axis targets degrades image quality in a coherent array imaging system. In ultrasound imaging, focusing errors resulting from sound-velocity inhomogeneities in human tissue--also known as phase aberrations reduce the coherence of the received signals and elevate the sidelobe level. This ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460502700205

    authors: Li ML,Huang SW,Ustüner K,Li PC

    更新日期:2005-04-01 00:00:00

  • Investigation of optimal method for inducing harmonic motion in tissue using a linear ultrasound phased array--a simulation study.

    abstract::Many noninvasive ultrasound techniques have been developed to explore mechanical properties of soft tissues. One of these methods, Localized Harmonic Motion Imaging (LHMI), has been proposed to be used for ultrasound surgery monitoring. In LHMI, dynamic ultrasound radiation-force stimulation induces displacements in a...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460602800203

    authors: Heikkilä J,Hynynen K

    更新日期:2006-04-01 00:00:00

  • Computerized quantification analysis of left ventricular wall motion from echocardiograms.

    abstract::Two-dimensional echocardiography (2-D echo) imaging is a more attractive clinical tool than other modalities that either involve radiation exposure or are too slow to image heart motion in real-time. Computer-aided analysis of left ventricular(LV) wall motion provides quantitative parameters for diagnosis. This study ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469701900204

    authors: Chen T,Chen TP,Tsai LM

    更新日期:1997-04-01 00:00:00

  • GPU-accelerated Kernel Regression Reconstruction for Freehand 3D Ultrasound Imaging.

    abstract::Volume reconstruction method plays an important role in improving reconstructed volumetric image quality for freehand three-dimensional (3D) ultrasound imaging. By utilizing the capability of programmable graphics processing unit (GPU), we can achieve a real-time incremental volume reconstruction at a speed of 25-50 f...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734616689464

    authors: Wen T,Li L,Zhu Q,Qin W,Gu J,Yang F,Xie Y

    更新日期:2017-07-01 00:00:00

  • Assessment of Age-related Oxygenation Changes in Calf Skeletal Muscle by Photoacoustic Imaging: A Potential Tool for Peripheral Arterial Disease.

    abstract::Peripheral artery disease is often asymptomatic, and various imaging and nonimaging techniques have been used for assessment and monitoring treatments. This study is designed to demonstrate the ability of photoacoustic imaging to noninvasively determine changes in tissue oxygenation that occur in mice's hind limb skel...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734619862287

    authors: Kirkham BM,Schultz SM,Ashi K,Sehgal CM

    更新日期:2019-09-01 00:00:00

  • Optimal transmit phasing for harmonic-background suppression with bipolar square-wave pulser.

    abstract::Optimal transmit phasing has been proposed to increase contrast-to-tissue ratio (CTR) by relatively phasing the tissue and leakage harmonic components to cancel each other out for tissue-background suppression in harmonic imaging. Since most clinical systems are only equipped with a bipolar square-wave pulser, effecti...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173461003200103

    authors: Shen CC,Yang YC,Chen WS

    更新日期:2010-01-01 00:00:00

  • Acoustic Structure Quantification Analysis of the Thyroid in Patients with Diffuse Autoimmune Thyroid Disease.

    abstract::The aim of this study was to assess whether acoustic structure quantification (ASQ) can differentiate normal from pathological thyroid parenchyma in patients with diffuse autoimmune thyroid disease (AITD). We evaluated 83 subjects (72 [87%] women and 11 [13%] men) aged 19 to 94 years with a mean age of 53 years. We pe...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615580766

    authors: Zandieh S,Bernt R,Zwerina J,Haller J,Knoll P,Seyeddain O,Mirzaei S

    更新日期:2016-03-01 00:00:00

  • Numerical study of higher-order diffraction tomography via the sinc basis moment method.

    abstract::Behavior and limitations of the sinc basis method have been discovered during simulation studies. An iterative row-action method (ART) is compared with a full-matrix, least-squares solution (QR decomposition) and the problem of multiple solutions is discussed. Knowledge of the spatial distribution of scattered field e...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468901100103

    authors: Cavicchi TJ,O'Brien WD Jr

    更新日期:1989-01-01 00:00:00

  • Ultrasound attenuation measurements of the liver in vivo using a commercial sector scanner.

    abstract::Attenuation measurements of various tissue mimicking phantoms and three different groups of patients were obtained using a modified commercial sector scanner. Estimates of attenuation were made using the spectral shift method with mean frequencies at different depths of a region of interest being obtained by both zero...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468400600402

    authors: Garra BS,Shawker TH,Nassi M,Russell MA

    更新日期:1984-10-01 00:00:00

  • Compressed Sensing for Elastography in Portable Ultrasound.

    abstract::Portable ultrasound is recently emerging as a new medical imaging modality featuring high portability, easy connectivity, and real-time on-site diagnostic ability. However, it does not yet provide ultrasound elastography function that enables the diagnosis of malignant lesions using elastic properties. This is mainly ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734617716938

    authors: Shin B,Jeon S,Ryu J,Kwon HJ

    更新日期:2017-11-01 00:00:00

  • A study of the display pixel-based focusing method in ultrasound imaging.

    abstract::This paper presents a new beamforming technique, in which ultrasound waves are focused at the display pixels on the Cartesian coordinates, rather than sampling points located on the uniformly-separated scanlines on either the polar or Cartesian coordinates. Consequently, this method does not require a digital scan con...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460102300101

    authors: Hwang JS,Song TK

    更新日期:2001-01-01 00:00:00

  • Attenuation and backscatter estimation using video signal analysis applied to B-mode images.

    abstract::Most methods for in vivo quantitation of ultrasound attenuation and backscatter are not available clinically because they rely upon acquiring and analyzing radio frequency (rf) echo signals. This paper describes a technique to estimate ultrasound attenuation and backscatter from B-mode image data. The video signal ana...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469701900305

    authors: Knipp BS,Zagzebski JA,Wilson TA,Dong F,Madsen EL

    更新日期:1997-07-01 00:00:00

  • Ultrasonic backscatter and attenuation (11-27 MHz) variation with collagen fiber distribution in ex vivo human dermis.

    abstract::This ex vivo study explores the relationship of ultrasonic attenuation and backscatter to dermal microarchitecture by comparing ultrasonic measurements of these parameters (11-27 MHz) to a microscopic analysis of three parameters describing the collagen distribution (mean thickness and spacing of collagen bundles alon...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460602800103

    authors: Bridal SL,Fournier C,Coron A,Leguerney I,Laugier P

    更新日期:2006-01-01 00:00:00

  • A quantitative approach to speckle reduction via frequency compounding.

    abstract::Coherent speckle is a source of image noise in ultrasonic B-mode imaging. The use of multiple imaging frequencies has been suggested as a technique for speckle contrast reduction. This technique involves the averaging of images whose speckle patterns have been modified by a change in the spectrum of the transmitted or...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468600800301

    authors: Trahey GE,Allison JW,Smith SW,von Ramm OT

    更新日期:1986-07-01 00:00:00

  • Autoregressive spectral estimation in ultrasonic scatterer size imaging.

    abstract::An autoregressive (AR) spectral estimation method was considered for the purpose of estimating scatterer size images. The variance and bias of the resulting estimates were compared with those using classical FFT periodograms for a range of input signal-to-noise ratios and echo-signal durations corresponding to various...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469601800102

    authors: Chaturvedi P,Insana MF

    更新日期:1996-01-01 00:00:00

  • Effective scatterer diameter estimates for broad scatterer size distributions.

    abstract::Acoustic form factors have been used to model the frequency dependence of acoustic scattering in phantoms and tissues. This work demonstrates that a broad range of scatterer sizes, individually well represented by Faran theory or a Gaussian form factor, is not accurately described by a single effective scatterer from ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734614534399

    authors: Nordberg EP,Hall TJ

    更新日期:2015-01-01 00:00:00

  • Ultrasonographic Multimodality Diagnostic Model of Thyroid Nodules.

    abstract::The aim of this study was to identify independent risk factors for thyroid cancer, establish an ultrasonographic multimodality diagnostic model for thyroid nodules, and explore the diagnostic value of the model. From November 2011 to February 2015, 307 patients with a total of 367 thyroid nodules underwent conventiona...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734618815070

    authors: Zhao RN,Zhang B,Jiang YX,Yang X,Lai XJ,Zhu SL,Zhang XY

    更新日期:2019-03-01 00:00:00

  • Ultrasonic tomography of biological tissue.

    abstract::In this paper, quantitative tomographic reconstructions of biological tissue are presented. First, the experimental setup and a hybrid filtered backpropagation (FBP) technique are briefly described. Using this technique, which includes exact backpropagation of data prior to reconstruction by means of the classical FBP...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469401600102

    authors: Sponheim N,Gelius LJ,Johansen I,Stamnes JJ

    更新日期:1994-01-01 00:00:00

  • Time reversal focusing applied to lithotripsy.

    abstract::Time reversal of ultrasonic field allows a very efficient approach to focusing pulsed ultrasonic waves through lossless inhomogeneous media. Time reversal mirrors (TRM) are made of large transducer arrays, allowing the incident acoustic field to be sampled, time reversed and re-emitted. Time reversal processing permit...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章,评审

    doi:10.1177/016173469601800202

    authors: Thomas JL,Wu F,Fink M

    更新日期:1996-04-01 00:00:00

  • Optimization of signal-to-noise ratio for multilayer PZT transducers.

    abstract::In medical ultrasound imaging, two-dimensional (2-D) array transducers are desirable to implement dynamic focusing and phase aberration correction in two dimensions as well as volumetric imaging. Unfortunately, the small size of a 2-D array element results in a small clamped capacitance and a large electrical impedanc...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469501700202

    authors: Goldberg RL,Smith SW

    更新日期:1995-04-01 00:00:00

  • Variance and covariance of accumulated displacement estimates.

    abstract::Tracking large deformations in tissue using ultrasound can enable the reconstruction of nonlinear elastic parameters, but poses a challenge to displacement estimation algorithms. Such large deformations have to be broken up into steps, each of which contributes an estimation error to the final accumulated displacement...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734613479246

    authors: Bayer M,Hall TJ

    更新日期:2013-04-01 00:00:00