A scalable architecture for real-time synthetic-focus imaging.

Abstract:

:A scalable architecture for forming real-time synthetic focus images is described and the design of a 256-channel system using currently-available technology is presented as an example implementation of the architecture. The parallelism of the system scales directly with the number of array elements and the image computation rate for a given image size (in pixels) stays constant as the number of array elements is increased. The system leverages earlier work in the real-time generation of the required time-of-flight surfaces and allows either real-time image generation or iterative adaptive image generation from a single complete data set.

journal_name

Ultrason Imaging

journal_title

Ultrasonic imaging

authors

Richard WD

doi

10.1177/016173460302500303

subject

Has Abstract

pub_date

2003-07-01 00:00:00

pages

151-61

issue

3

eissn

0161-7346

issn

1096-0910

journal_volume

25

pub_type

杂志文章
  • Ultrasonic tomography of biological tissue.

    abstract::In this paper, quantitative tomographic reconstructions of biological tissue are presented. First, the experimental setup and a hybrid filtered backpropagation (FBP) technique are briefly described. Using this technique, which includes exact backpropagation of data prior to reconstruction by means of the classical FBP...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469401600102

    authors: Sponheim N,Gelius LJ,Johansen I,Stamnes JJ

    更新日期:1994-01-01 00:00:00

  • Shielding of piezoelectric ultrasonic probes in Hall effect imaging.

    abstract::This paper addresses significant sources of electromagnetic noise in Hall effect imaging. Hall effect imaging employs large electrical pulses for signal generation and high sensitivity ultrasonic probes for signal reception. Coherent noise arises through various coupling mechanisms between the excitation pulse and the...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469802000305

    authors: Wen H,Bennett E,Wiesler DG

    更新日期:1998-07-01 00:00:00

  • On the feasibility of imaging peripheral nerves using acoustic radiation force impulse imaging.

    abstract::Regional anesthesia is preferred over general anesthesia for many surgical procedures; however, challenges associated with poor image guidance limit its widespread acceptance as a viable alternative. In B-mode ultrasound images, the current standard for guidance, nerves can be difficult to visualize due to their simil...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460903100303

    authors: Palmeri ML,Dahl JJ,MacLeod DB,Grant SA,Nightingale KR

    更新日期:2009-07-01 00:00:00

  • Ultrasonographic Multimodality Diagnostic Model of Thyroid Nodules.

    abstract::The aim of this study was to identify independent risk factors for thyroid cancer, establish an ultrasonographic multimodality diagnostic model for thyroid nodules, and explore the diagnostic value of the model. From November 2011 to February 2015, 307 patients with a total of 367 thyroid nodules underwent conventiona...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734618815070

    authors: Zhao RN,Zhang B,Jiang YX,Yang X,Lai XJ,Zhu SL,Zhang XY

    更新日期:2019-03-01 00:00:00

  • Temperature dependence of ultrasonic propagation speed and attenuation in canine tissue.

    abstract::Previously reported data on the temperature dependence of propagation speed in tissues generally span only temperature ranges up to 60 degrees C. However, with the emerging use of thermal ablative therapies, information on variation in this parameter over higher temperature ranges is needed. Measurements of the ultras...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460202400404

    authors: Techavipoo U,Varghese T,Zagzebski JA,Stiles T,Frank G

    更新日期:2002-10-01 00:00:00

  • A study of the display pixel-based focusing method in ultrasound imaging.

    abstract::This paper presents a new beamforming technique, in which ultrasound waves are focused at the display pixels on the Cartesian coordinates, rather than sampling points located on the uniformly-separated scanlines on either the polar or Cartesian coordinates. Consequently, this method does not require a digital scan con...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460102300101

    authors: Hwang JS,Song TK

    更新日期:2001-01-01 00:00:00

  • Quantitative assessment of in vivo backscatter enhancement from gelatin microspheres.

    abstract::Experimental work using a quantitative C-scan technique to measure in situ enhancement of hepatic backscatter resulting from the administration of gelatin microspheres to dogs is reported. We have found that reproducible enhancement of hepatic backscatter on the order of 2 dB followed the peripheral administration of ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468500700402

    authors: Ophir J,Gobuty A,Maklad N,Tyler T,Jaeger P,McWhirt R

    更新日期:1985-10-01 00:00:00

  • Effective scatterer diameter estimates for broad scatterer size distributions.

    abstract::Acoustic form factors have been used to model the frequency dependence of acoustic scattering in phantoms and tissues. This work demonstrates that a broad range of scatterer sizes, individually well represented by Faran theory or a Gaussian form factor, is not accurately described by a single effective scatterer from ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734614534399

    authors: Nordberg EP,Hall TJ

    更新日期:2015-01-01 00:00:00

  • Breast tissue classification using diagnostic ultrasound and pattern recognition techniques: II. Experimental results.

    abstract::The methods of statistical pattern recognition have been applied to the problem of in vivo ultrasonic characterization of breast disease in humans. Backscattered A-mode signals obtained from a commercial pulse imaging system were used to generate a large set of potentially useful features. Using statistical tests, a s...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468300500107

    authors: Finette S,Bleier AR,Swindell W,Haber K

    更新日期:1983-01-01 00:00:00

  • Wavelet-based speckle noise reduction in ultrasound B-scan images.

    abstract::Speckle noise is known to be signal-dependent in ultrasound imaging. Hence, separating noise from signal becomes a difficult task. This paper describes a wavelet-based method for reducing speckle noise. We derive from the model of the displayed ultrasound image the optimal wavelet-domain filter in the least mean-squar...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460002200201

    authors: Rakotomamonjy A,Deforge P,Marché P

    更新日期:2000-04-01 00:00:00

  • Optical tracking of superficial dynamics from an acoustic radiation force-induced excitation.

    abstract::Acoustic radiation force (ARF) has become a common excitation mechanism in elasticity imaging. The high acoustic intensities and subsequent generation of harmonics, however, hamper the effectiveness of using conventional radiofrequency (rf) tracking to investigate the dynamics of tissues and catheter-based transducers...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:

    authors: Bouchard RR,Van Soest G,Trahey GE,Van Der Steen AF

    更新日期:2009-01-01 00:00:00

  • Subharmonic contrast microbubble signals for noninvasive pressure estimation under static and dynamic flow conditions.

    abstract::Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled co...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173461103300301

    authors: Halldorsdottir VG,Dave JK,Leodore LM,Eisenbrey JR,Park S,Hall AL,Thomenius K,Forsberg F

    更新日期:2011-07-01 00:00:00

  • Dispersion and shear modulus measurements of porcine liver.

    abstract::A narrow-band ultrasonic shear-wave imaging technique for estimating phase speed was applied to fresh and thermally damaged porcine liver in vitro. Two constitutive models were applied to the measurements to represent rheological behavior of the tissue and estimate the complex shear modulus at frequencies between 50 a...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173461003200405

    authors: Orescanin M,Qayyum MA,Toohey KS,Insana MF

    更新日期:2010-10-01 00:00:00

  • Classification of scattering objects by regular arrays of scatterers using Fourier analysis.

    abstract::For a class of scattering objects the mean separation between the scatterers is determined. Over a range of frequencies, ultrasonic back-scattered pressure signals are recorded. It is suggested to derive the mean spacing of an unknown scattering object by employing Fourier analysis and comparing the signal with signal...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468300500405

    authors: Koch I

    更新日期:1983-10-01 00:00:00

  • Optimization of signal-to-noise ratio for multilayer PZT transducers.

    abstract::In medical ultrasound imaging, two-dimensional (2-D) array transducers are desirable to implement dynamic focusing and phase aberration correction in two dimensions as well as volumetric imaging. Unfortunately, the small size of a 2-D array element results in a small clamped capacitance and a large electrical impedanc...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469501700202

    authors: Goldberg RL,Smith SW

    更新日期:1995-04-01 00:00:00

  • Digital simulation of pulsed ultrasonic waveforms.

    abstract::When modeling or simulating an ultrasonic pulse-echo system it is necessary to know the transducer waveforms that are the input to the system. In general, accurate transducer modeling is complex and waveform calculation is computationally intensive. Because of this, investigators often assume these waveforms to be sim...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468700900405

    authors: Barber FE,Goodsitt MM

    更新日期:1987-10-01 00:00:00

  • Reduction of the clutter component in Doppler ultrasound signals based on singular value decomposition: a simulation study.

    abstract::In pulsed Doppler ultrasound systems, the ultrasound radiofrequency (RF) signals received can be employed to estimate noninvasively the time-dependent blood velocity distribution within and artery. The RF signals are composed of signals originating from clutter (e.g., vessel walls) and scatterers (e.g., red blood cell...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469701900101

    authors: Ledoux LA,Brands PJ,Hoeks AP

    更新日期:1997-01-01 00:00:00

  • Acoustic Structure Quantification Analysis of the Thyroid in Patients with Diffuse Autoimmune Thyroid Disease.

    abstract::The aim of this study was to assess whether acoustic structure quantification (ASQ) can differentiate normal from pathological thyroid parenchyma in patients with diffuse autoimmune thyroid disease (AITD). We evaluated 83 subjects (72 [87%] women and 11 [13%] men) aged 19 to 94 years with a mean age of 53 years. We pe...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615580766

    authors: Zandieh S,Bernt R,Zwerina J,Haller J,Knoll P,Seyeddain O,Mirzaei S

    更新日期:2016-03-01 00:00:00

  • Assessment of Age-related Oxygenation Changes in Calf Skeletal Muscle by Photoacoustic Imaging: A Potential Tool for Peripheral Arterial Disease.

    abstract::Peripheral artery disease is often asymptomatic, and various imaging and nonimaging techniques have been used for assessment and monitoring treatments. This study is designed to demonstrate the ability of photoacoustic imaging to noninvasively determine changes in tissue oxygenation that occur in mice's hind limb skel...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734619862287

    authors: Kirkham BM,Schultz SM,Ashi K,Sehgal CM

    更新日期:2019-09-01 00:00:00

  • Real-time 3D transesophageal echocardiography.

    abstract::Transesophageal echocardiography (TEE) is an essential diagnostic tool in patients with poor transthoracic echocardiographic windows or when detailed imaging of structures distant from the chest wall is necessary. A real-time 3D TEE probe has been fabricated in our laboratory in order to increase the amount of informa...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460402600402

    authors: Pua EC,Idriss SF,Wolf PD,Smith SW

    更新日期:2004-10-01 00:00:00

  • Adaptive imaging using an optimal receive aperture size.

    abstract::Sidelobe contribution from off-axis targets degrades image quality in a coherent array imaging system. In ultrasound imaging, focusing errors resulting from sound-velocity inhomogeneities in human tissue--also known as phase aberrations reduce the coherence of the received signals and elevate the sidelobe level. This ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460502700205

    authors: Li ML,Huang SW,Ustüner K,Li PC

    更新日期:2005-04-01 00:00:00

  • Mathematical simulation of pressure pulse propagation in biological tissues.

    abstract::The propagation of pressure pulses of arbitrary time form in inhomogeneous attenuating media with characteristics similar to real biological tissues is considered. A mathematical model using the quasi-optical approximation is developed to solve the wave equation. Such a model proves to be convenient for computer reali...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469301500106

    authors: Adrov VN,Chernomordik VV

    更新日期:1993-01-01 00:00:00

  • Characterization of tongue shape.

    abstract::Mathematical techniques are described for analyzing tongue shapes obtained with ultrasound images. The surface of the mid-sagittal section of the tongue was approximated by discrete points. In turn, these points were used to approximate position, slope and curvature of the tongue surface at a fixed time during speech....

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468400600104

    authors: Morrish KA,Stone M,Sonies BC,Kurtz D,Shawker T

    更新日期:1984-01-01 00:00:00

  • Transducer characterization from pressure amplitude distribution measurements using a Kalman filter as parameter estimation algorithm.

    abstract::The amplitude and frequency contents of a received ultrasound pulse depends on the spatial pressure amplitude distribution of the sound field, as produced by the transducer in the medium, and on the position and orientation of the reflecting surface in this field. Often, the geometry of the reflecting surface and the ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469001200405

    authors: Linssen FM,Hoeks AP

    更新日期:1990-10-01 00:00:00

  • Neural-network-based Motion Tracking for Breast Ultrasound Strain Elastography: An Initial Assessment of Performance and Feasibility.

    abstract::Accurate tracking of tissue motion is critically important for several ultrasound elastography methods. In this study, we investigate the feasibility of using three published convolution neural network (CNN) models built for optical flow (hereafter referred to as CNN-based tracking) by the computer vision community fo...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734620902527

    authors: Peng B,Xian Y,Zhang Q,Jiang J

    更新日期:2020-03-01 00:00:00

  • Performance evaluation of ultrasonic Nakagami image in tissue characterization.

    abstract::Conventional ultrasonic B-mode images qualitatively describe tissue structures but are unsuitable for quantitative analyses of scatterer properties. We have recently developed an ultrasonic parametric imaging technique based on the Nakagami statistical distribution that is able to quantify scatterer concentrations. Th...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460803000202

    authors: Tsui PH,Yeh CK,Chang CC,Chen WS

    更新日期:2008-04-01 00:00:00

  • Variance and covariance of accumulated displacement estimates.

    abstract::Tracking large deformations in tissue using ultrasound can enable the reconstruction of nonlinear elastic parameters, but poses a challenge to displacement estimation algorithms. Such large deformations have to be broken up into steps, each of which contributes an estimation error to the final accumulated displacement...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734613479246

    authors: Bayer M,Hall TJ

    更新日期:2013-04-01 00:00:00

  • Deconvolution of in-vivo ultrasound B-mode images.

    abstract::An algorithm for deconvolution of medical ultrasound images is presented. The procedure involves estimation of the basic one-dimensional ultrasound pulse, determining the ratio of the covariance of the noise to the covariance of the reflection signal, and finally deconvolution of the rf signal from the transducer. Usi...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469301500204

    authors: Jensen JA,Mathorne J,Gravesen T,Stage B

    更新日期:1993-04-01 00:00:00

  • Compressed Sensing for Elastography in Portable Ultrasound.

    abstract::Portable ultrasound is recently emerging as a new medical imaging modality featuring high portability, easy connectivity, and real-time on-site diagnostic ability. However, it does not yet provide ultrasound elastography function that enables the diagnosis of malignant lesions using elastic properties. This is mainly ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734617716938

    authors: Shin B,Jeon S,Ryu J,Kwon HJ

    更新日期:2017-11-01 00:00:00

  • Computerized ultrasound B-scan texture analysis of experimental fatty liver disease: influence of total lipid content and fat deposit distribution.

    abstract::Statistical pattern recognition procedures allow a quantitative description of ultrasound-B-scan image texture. According to well-established animal models, different types of fatty liver disease were induced in female Wistar rats. For the correlation of the computerized ultrasound image with its underlying histology ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469001200302

    authors: Layer G,Zuna I,Lorenz A,Zerban H,Haberkorn U,Bannasch P,van Kaick G,Räth U

    更新日期:1990-07-01 00:00:00