Quantitative assessment of in vivo backscatter enhancement from gelatin microspheres.

Abstract:

:Experimental work using a quantitative C-scan technique to measure in situ enhancement of hepatic backscatter resulting from the administration of gelatin microspheres to dogs is reported. We have found that reproducible enhancement of hepatic backscatter on the order of 2 dB followed the peripheral administration of gelatin within minutes, the magnitude of the effect was not sensitive to the rate of infusion, but was likely to be dose dependent, changes in the overlying tissue attenuation had a pronounced effect on the measurement, and the effect was sustained for up to one half hour or longer.

journal_name

Ultrason Imaging

journal_title

Ultrasonic imaging

authors

Ophir J,Gobuty A,Maklad N,Tyler T,Jaeger P,McWhirt R

doi

10.1177/016173468500700402

subject

Has Abstract

pub_date

1985-10-01 00:00:00

pages

293-9

issue

4

eissn

0161-7346

issn

1096-0910

journal_volume

7

pub_type

杂志文章
  • Diffraction tomography using arbitrary transmitter and receiver surfaces.

    abstract::The theory of diffraction tomography for two-dimensional objects within the Born approximation is presented for cases where the scattered field is measured over arbitrarily shaped boundaries surrounding the object. Reconstruction algorithms are presented for both plane wave (parallel beam) and cylindrical wave (fan be...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468400600207

    authors: Devaney AJ,Beylkin G

    更新日期:1984-04-01 00:00:00

  • An adaptive approach to computing the spectrum and mean frequency of Doppler signals.

    abstract::Modern ultrasound Doppler systems are facing the problem of processing increasingly shorter data sets. Spectral analysis of the strongly nonstationary Doppler signal needs to shorten the analysis window while maintaining a low variance and high resolution spectrum. Color flow imaging requires estimation of the Doppler...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469501700101

    authors: Herment A,Giovannelli JF

    更新日期:1995-01-01 00:00:00

  • Breast-lesion Segmentation Combining B-Mode and Elastography Ultrasound.

    abstract::Breast ultrasound (BUS) imaging has become a crucial modality, especially for providing a complementary view when other modalities (i.e., mammography) are not conclusive in the task of assessing lesions. The specificity in cancer detection using BUS imaging is low. These false-positive findings often lead to an increa...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615589287

    authors: Pons G,Martí J,Martí R,Ganau S,Noble JA

    更新日期:2016-05-01 00:00:00

  • A method for in vitro mapping of ultrasonic speed and density in breast tissue.

    abstract::A method has been developed for mapping density and ultrasonic speed in 1 mm thick slices of soft tissue with a resolution of about 1 mm. Tests using phantom sections have verified the accuracy and resolution of the ultrasonic speed maps. The method has been applied to breast tissues of three patients including tumors...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469101300105

    authors: Yang JN,Murphy AD,Madsen EL,Zagzebski JA,Gilchrist KW,Frank GR,Macdonald MC,Millard CA,Faraggi A,Jaramillo CA

    更新日期:1991-01-01 00:00:00

  • Performance evaluation of ultrasonic Nakagami image in tissue characterization.

    abstract::Conventional ultrasonic B-mode images qualitatively describe tissue structures but are unsuitable for quantitative analyses of scatterer properties. We have recently developed an ultrasonic parametric imaging technique based on the Nakagami statistical distribution that is able to quantify scatterer concentrations. Th...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460803000202

    authors: Tsui PH,Yeh CK,Chang CC,Chen WS

    更新日期:2008-04-01 00:00:00

  • Time reversal focusing applied to lithotripsy.

    abstract::Time reversal of ultrasonic field allows a very efficient approach to focusing pulsed ultrasonic waves through lossless inhomogeneous media. Time reversal mirrors (TRM) are made of large transducer arrays, allowing the incident acoustic field to be sampled, time reversed and re-emitted. Time reversal processing permit...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章,评审

    doi:10.1177/016173469601800202

    authors: Thomas JL,Wu F,Fink M

    更新日期:1996-04-01 00:00:00

  • Frequency diversity speckle processing.

    abstract::Ultrasonic waveform data from a tissue-mimicking phantom containing low contrast targets was digitized, stored and processed prior to creating and displaying ultrasonic images. Speckle reduction was performed by digital filtering of the waveform data with appropriately spaced and weighted digital filters, prior to bot...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468700900202

    authors: Gehlbach SM,Sommer FG

    更新日期:1987-04-01 00:00:00

  • Acoustic Structure Quantification Analysis of the Thyroid in Patients with Diffuse Autoimmune Thyroid Disease.

    abstract::The aim of this study was to assess whether acoustic structure quantification (ASQ) can differentiate normal from pathological thyroid parenchyma in patients with diffuse autoimmune thyroid disease (AITD). We evaluated 83 subjects (72 [87%] women and 11 [13%] men) aged 19 to 94 years with a mean age of 53 years. We pe...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615580766

    authors: Zandieh S,Bernt R,Zwerina J,Haller J,Knoll P,Seyeddain O,Mirzaei S

    更新日期:2016-03-01 00:00:00

  • On the feasibility of imaging peripheral nerves using acoustic radiation force impulse imaging.

    abstract::Regional anesthesia is preferred over general anesthesia for many surgical procedures; however, challenges associated with poor image guidance limit its widespread acceptance as a viable alternative. In B-mode ultrasound images, the current standard for guidance, nerves can be difficult to visualize due to their simil...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460903100303

    authors: Palmeri ML,Dahl JJ,MacLeod DB,Grant SA,Nightingale KR

    更新日期:2009-07-01 00:00:00

  • A study of the display pixel-based focusing method in ultrasound imaging.

    abstract::This paper presents a new beamforming technique, in which ultrasound waves are focused at the display pixels on the Cartesian coordinates, rather than sampling points located on the uniformly-separated scanlines on either the polar or Cartesian coordinates. Consequently, this method does not require a digital scan con...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460102300101

    authors: Hwang JS,Song TK

    更新日期:2001-01-01 00:00:00

  • In vivo study of online liver tissue classification based on envelope power spectrum analysis.

    abstract::An ultrasonic imaging and signal analysis system, combining a 3.5 MHz linear array B-scanner and an array processor, has been realized for a clinical liver tissue classification study. Based on the complete unprocessed rf data set of a real time B-image, local envelope power spectra averaged over interactively defined...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469401600202

    authors: Lang M,Ermert H,Heuser L

    更新日期:1994-04-01 00:00:00

  • A comparison method for mean frequency estimators for Doppler ultrasound.

    abstract::Mean frequency estimators as used in pulsed Doppler ultrasound equipment should provide an accurate (quality) and consistent (robustness) estimate over a wide range of signal conditions. In a simplified signal model, the main parameters to consider are the noise level, mean frequency, bandwidth and power of both the D...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469201400404

    authors: Brands PJ,Hoeks AP

    更新日期:1992-10-01 00:00:00

  • The Maltese cross processor: speckle reduction for circular transducers.

    abstract::A new online signal processing technique is described to reduce speckle noise in ultrasound images. In the imaging system, a focused piston transducer is divided into thirty-two sectors. In the receive mode, parallel signal processing arranges the sectors into eight maltese crosses. The rf signals of the perpendicular...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468801000301

    authors: Smith SW,von Ramm OT

    更新日期:1988-07-01 00:00:00

  • Computerized ultrasound B-scan texture analysis of experimental fatty liver disease: influence of total lipid content and fat deposit distribution.

    abstract::Statistical pattern recognition procedures allow a quantitative description of ultrasound-B-scan image texture. According to well-established animal models, different types of fatty liver disease were induced in female Wistar rats. For the correlation of the computerized ultrasound image with its underlying histology ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469001200302

    authors: Layer G,Zuna I,Lorenz A,Zerban H,Haberkorn U,Bannasch P,van Kaick G,Räth U

    更新日期:1990-07-01 00:00:00

  • Optical tracking of superficial dynamics from an acoustic radiation force-induced excitation.

    abstract::Acoustic radiation force (ARF) has become a common excitation mechanism in elasticity imaging. The high acoustic intensities and subsequent generation of harmonics, however, hamper the effectiveness of using conventional radiofrequency (rf) tracking to investigate the dynamics of tissues and catheter-based transducers...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:

    authors: Bouchard RR,Van Soest G,Trahey GE,Van Der Steen AF

    更新日期:2009-01-01 00:00:00

  • Effective scatterer diameter estimates for broad scatterer size distributions.

    abstract::Acoustic form factors have been used to model the frequency dependence of acoustic scattering in phantoms and tissues. This work demonstrates that a broad range of scatterer sizes, individually well represented by Faran theory or a Gaussian form factor, is not accurately described by a single effective scatterer from ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734614534399

    authors: Nordberg EP,Hall TJ

    更新日期:2015-01-01 00:00:00

  • Classification of scattering objects by regular arrays of scatterers using Fourier analysis.

    abstract::For a class of scattering objects the mean separation between the scatterers is determined. Over a range of frequencies, ultrasonic back-scattered pressure signals are recorded. It is suggested to derive the mean spacing of an unknown scattering object by employing Fourier analysis and comparing the signal with signal...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468300500405

    authors: Koch I

    更新日期:1983-10-01 00:00:00

  • Experimental Validation of ARFI Surveillance of Subcutaneous Hemorrhage (ASSH) Using Calibrated Infusions in a Tissue-Mimicking Model and Dogs.

    abstract::Acoustic radiation force impulse (ARFI) Surveillance of Subcutaneous Hemorrhage (ASSH) has been previously demonstrated to differentiate bleeding phenotype and responses to therapy in dogs and humans, but to date, the method has lacked experimental validation. This work explores experimental validation of ASSH in a po...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615617940

    authors: Geist RE,DuBois CH,Nichols TC,Caughey MC,Merricks EP,Raymer R,Gallippi CM

    更新日期:2016-09-01 00:00:00

  • Feasibility exploration of blood flow estimation by contrast-assisted Nakagami imaging.

    abstract::The microbubble contrast agent destruction/replenishment technique has been widely applied to ultrasound-based blood flow estimation. The rate of increase of the time-intensity curve (TIC) due to microbubbles flowing into the region of interest as measured from B-mode images closely reflects the flow velocity. In this...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460803000301

    authors: Tsui PH,Yeh CK,Chang CC

    更新日期:2008-07-01 00:00:00

  • Linear arrays for vibro-acoustography: a numerical simulation study.

    abstract::In this work, we study linear array beamforming for vibro-acoustography systems. The goal of this research is to assess the feasibility of vibro-acoustography imaging systems based on linear arrays for clinical applications. The vibro-acoustography transducer is designed with two arrays driven by two continuous-wave o...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460402600101

    authors: Silva GT,Greenleaf JF,Fatemi M

    更新日期:2004-01-01 00:00:00

  • Mean scatterer spacing estimation in normal and thermally coagulated ex vivo bovine liver.

    abstract::The liver has been hypothesized to have a unique arrangement of microvasculature that presents as an arrangement of quasiperiodic scatterers to an interrogating ultrasound pulse. The mean scatterer spacing (MSS) of these quasiperiodic scatterers has been proposed as a useful quantitative ultrasound biomarker for chara...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734613511232

    authors: Rubert N,Varghese T

    更新日期:2014-04-01 00:00:00

  • Dispersion and shear modulus measurements of porcine liver.

    abstract::A narrow-band ultrasonic shear-wave imaging technique for estimating phase speed was applied to fresh and thermally damaged porcine liver in vitro. Two constitutive models were applied to the measurements to represent rheological behavior of the tissue and estimate the complex shear modulus at frequencies between 50 a...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173461003200405

    authors: Orescanin M,Qayyum MA,Toohey KS,Insana MF

    更新日期:2010-10-01 00:00:00

  • Improved Fourier-transform-based parallel receive beam formation.

    abstract::A Fourier transform (FT)-based technique for forming parallel receive beams has been previously employed to increase the imaging frame rate in ultrasonic imaging. However, the image quality in FT-based parallel reconstruction is degraded because differences in range focusing delays are ignored and a wide transmit beam...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460302500201

    authors: Li ML,Li PC

    更新日期:2003-04-01 00:00:00

  • Optimization of signal-to-noise ratio for multilayer PZT transducers.

    abstract::In medical ultrasound imaging, two-dimensional (2-D) array transducers are desirable to implement dynamic focusing and phase aberration correction in two dimensions as well as volumetric imaging. Unfortunately, the small size of a 2-D array element results in a small clamped capacitance and a large electrical impedanc...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469501700202

    authors: Goldberg RL,Smith SW

    更新日期:1995-04-01 00:00:00

  • Investigation of optimal method for inducing harmonic motion in tissue using a linear ultrasound phased array--a simulation study.

    abstract::Many noninvasive ultrasound techniques have been developed to explore mechanical properties of soft tissues. One of these methods, Localized Harmonic Motion Imaging (LHMI), has been proposed to be used for ultrasound surgery monitoring. In LHMI, dynamic ultrasound radiation-force stimulation induces displacements in a...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460602800203

    authors: Heikkilä J,Hynynen K

    更新日期:2006-04-01 00:00:00

  • Computerized quantification analysis of left ventricular wall motion from echocardiograms.

    abstract::Two-dimensional echocardiography (2-D echo) imaging is a more attractive clinical tool than other modalities that either involve radiation exposure or are too slow to image heart motion in real-time. Computer-aided analysis of left ventricular(LV) wall motion provides quantitative parameters for diagnosis. This study ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469701900204

    authors: Chen T,Chen TP,Tsai LM

    更新日期:1997-04-01 00:00:00

  • Statistical relationship between ultrasound echo envelope and envelope peak.

    abstract::This study shows that the amplitude information of ultrasound echoes is carried mainly by the envelope peaks (EPs). It is first shown that the EPs in an A-line represent the maximum number of independent amplitude data. It is then demonstrated that the entire envelope could be approximately reconstructed from the EPs....

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468801000403

    authors: He P

    更新日期:1988-10-01 00:00:00

  • Transducer characterization from pressure amplitude distribution measurements using a Kalman filter as parameter estimation algorithm.

    abstract::The amplitude and frequency contents of a received ultrasound pulse depends on the spatial pressure amplitude distribution of the sound field, as produced by the transducer in the medium, and on the position and orientation of the reflecting surface in this field. Often, the geometry of the reflecting surface and the ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469001200405

    authors: Linssen FM,Hoeks AP

    更新日期:1990-10-01 00:00:00

  • Compressed Sensing for Elastography in Portable Ultrasound.

    abstract::Portable ultrasound is recently emerging as a new medical imaging modality featuring high portability, easy connectivity, and real-time on-site diagnostic ability. However, it does not yet provide ultrasound elastography function that enables the diagnosis of malignant lesions using elastic properties. This is mainly ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734617716938

    authors: Shin B,Jeon S,Ryu J,Kwon HJ

    更新日期:2017-11-01 00:00:00

  • Phase-derivative imaging. II: Effects of beam diffraction and scatterer density.

    abstract::The potential of using the phase derivative (PD) of the radio-frequency echograms for producing 2-dimensional grey scale images was further investigated. The PD images were produced by five different algorithms, which according to the results described in the companion paper yield PD images dominated by the amplitude ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468901100301

    authors: Oosterveld BJ,Romijn RL,Thijssen JM

    更新日期:1989-07-01 00:00:00