Time reversal focusing applied to lithotripsy.

Abstract:

:Time reversal of ultrasonic field allows a very efficient approach to focusing pulsed ultrasonic waves through lossless inhomogeneous media. Time reversal mirrors (TRM) are made of large transducer arrays, allowing the incident acoustic field to be sampled, time reversed and re-emitted. Time reversal processing permits a choice of any temporal window to be time reversed, allowing operation in an iterative mode. In multitarget media, this process converges on the most reflective target, i.e., the dominant scatterer. In this paper, the time reversal process is applied to track, in real time, a moving gall bladder or kidney stone embedded in its surrounding medium. We investigate the feasibility of a piezoelectric shock wave generator in which the focal zone is moved electronically to track the stone during a lithotripsy treatment. We show that TRM allows us to obtain sharp focusing on one bright point of the stone. The time of flight profile is then determined and used in a least-mean-square method to calculate the spatial coordinates of the stone.

journal_name

Ultrason Imaging

journal_title

Ultrasonic imaging

authors

Thomas JL,Wu F,Fink M

doi

10.1177/016173469601800202

subject

Has Abstract

pub_date

1996-04-01 00:00:00

pages

106-21

issue

2

eissn

0161-7346

issn

1096-0910

journal_volume

18

pub_type

杂志文章,评审
  • Subharmonic contrast microbubble signals for noninvasive pressure estimation under static and dynamic flow conditions.

    abstract::Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled co...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173461103300301

    authors: Halldorsdottir VG,Dave JK,Leodore LM,Eisenbrey JR,Park S,Hall AL,Thomenius K,Forsberg F

    更新日期:2011-07-01 00:00:00

  • Optimization of signal-to-noise ratio for multilayer PZT transducers.

    abstract::In medical ultrasound imaging, two-dimensional (2-D) array transducers are desirable to implement dynamic focusing and phase aberration correction in two dimensions as well as volumetric imaging. Unfortunately, the small size of a 2-D array element results in a small clamped capacitance and a large electrical impedanc...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469501700202

    authors: Goldberg RL,Smith SW

    更新日期:1995-04-01 00:00:00

  • Temperature dependence of ultrasonic propagation speed and attenuation in canine tissue.

    abstract::Previously reported data on the temperature dependence of propagation speed in tissues generally span only temperature ranges up to 60 degrees C. However, with the emerging use of thermal ablative therapies, information on variation in this parameter over higher temperature ranges is needed. Measurements of the ultras...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460202400404

    authors: Techavipoo U,Varghese T,Zagzebski JA,Stiles T,Frank G

    更新日期:2002-10-01 00:00:00

  • Ultrasound attenuation measurements of the liver in vivo using a commercial sector scanner.

    abstract::Attenuation measurements of various tissue mimicking phantoms and three different groups of patients were obtained using a modified commercial sector scanner. Estimates of attenuation were made using the spectral shift method with mean frequencies at different depths of a region of interest being obtained by both zero...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468400600402

    authors: Garra BS,Shawker TH,Nassi M,Russell MA

    更新日期:1984-10-01 00:00:00

  • Optimal transmit phasing for harmonic-background suppression with bipolar square-wave pulser.

    abstract::Optimal transmit phasing has been proposed to increase contrast-to-tissue ratio (CTR) by relatively phasing the tissue and leakage harmonic components to cancel each other out for tissue-background suppression in harmonic imaging. Since most clinical systems are only equipped with a bipolar square-wave pulser, effecti...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173461003200103

    authors: Shen CC,Yang YC,Chen WS

    更新日期:2010-01-01 00:00:00

  • Feasibility exploration of blood flow estimation by contrast-assisted Nakagami imaging.

    abstract::The microbubble contrast agent destruction/replenishment technique has been widely applied to ultrasound-based blood flow estimation. The rate of increase of the time-intensity curve (TIC) due to microbubbles flowing into the region of interest as measured from B-mode images closely reflects the flow velocity. In this...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460803000301

    authors: Tsui PH,Yeh CK,Chang CC

    更新日期:2008-07-01 00:00:00

  • Digital simulation of pulsed ultrasonic waveforms.

    abstract::When modeling or simulating an ultrasonic pulse-echo system it is necessary to know the transducer waveforms that are the input to the system. In general, accurate transducer modeling is complex and waveform calculation is computationally intensive. Because of this, investigators often assume these waveforms to be sim...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468700900405

    authors: Barber FE,Goodsitt MM

    更新日期:1987-10-01 00:00:00

  • Mathematical simulation of pressure pulse propagation in biological tissues.

    abstract::The propagation of pressure pulses of arbitrary time form in inhomogeneous attenuating media with characteristics similar to real biological tissues is considered. A mathematical model using the quasi-optical approximation is developed to solve the wave equation. Such a model proves to be convenient for computer reali...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469301500106

    authors: Adrov VN,Chernomordik VV

    更新日期:1993-01-01 00:00:00

  • Reconstructive ultrasound elasticity imaging for renal transplant diagnosis: kidney ex vivo results.

    abstract::It may be possible to diagnose and monitor scarring, inflammation and edema in transplant kidney using reconstructive ultrasound elasticity imaging. Kidney elasticity is expected to change dramatically with scar, and to a lesser degree, with acute inflammation and edema. The hypothesis that changes in kidney elasticit...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460002200303

    authors: Emelianov SY,Lubinski MA,Skovoroda AR,Erkamp RQ,Leavey SF,Wiggins RC,O'Donnell M

    更新日期:2000-07-01 00:00:00

  • A Variance-reduction Approach to Detection of the Thyroid-nodule Boundary on Ultrasound Images.

    abstract::To perform computer-aided diagnosis of the thyroid nodules on ultrasound images, the location and boundary of nodules should be clearly defined. However, the identification of thyroid nodule boundary is a difficult issue due to the biological characteristics of the nodules, the physics and quality of ultrasound imagin...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734619839648

    authors: Chiu LY,Chen A

    更新日期:2019-07-01 00:00:00

  • Compressed Sensing for Elastography in Portable Ultrasound.

    abstract::Portable ultrasound is recently emerging as a new medical imaging modality featuring high portability, easy connectivity, and real-time on-site diagnostic ability. However, it does not yet provide ultrasound elastography function that enables the diagnosis of malignant lesions using elastic properties. This is mainly ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734617716938

    authors: Shin B,Jeon S,Ryu J,Kwon HJ

    更新日期:2017-11-01 00:00:00

  • Toward Noninvasive Mapping of Diffuse Scattering in the Presence of Motion.

    abstract::Ultrasonic coda wave analysis techniques localize defects in fields such as seismography and nondestructive testing. In medical ultrasound, these techniques might provide novel mapping of tissue properties in diseases characterized by local fibrosis. In this work, we present an approach for localizing variation in sca...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734619899885

    authors: Lindsey BD,Collins GC

    更新日期:2020-01-01 00:00:00

  • Rotation Elastogram Estimation Using Synthetic Transmit-aperture Technique: A Feasibility Study.

    abstract::It is well-documented in literature that benign breast lesions, such as fibroadenomas, are loosely bonded to their surrounding tissue and tend to slip under a small quasi-static compression, whereas malignant lesions being firmly bonded to their surrounding tissue do not slip. Recent developments in quasi-static ultra...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734616686746

    authors: B L,Chintada BR,Thittai AK

    更新日期:2017-05-01 00:00:00

  • Neural-network-based Motion Tracking for Breast Ultrasound Strain Elastography: An Initial Assessment of Performance and Feasibility.

    abstract::Accurate tracking of tissue motion is critically important for several ultrasound elastography methods. In this study, we investigate the feasibility of using three published convolution neural network (CNN) models built for optical flow (hereafter referred to as CNN-based tracking) by the computer vision community fo...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734620902527

    authors: Peng B,Xian Y,Zhang Q,Jiang J

    更新日期:2020-03-01 00:00:00

  • Improved Fourier-transform-based parallel receive beam formation.

    abstract::A Fourier transform (FT)-based technique for forming parallel receive beams has been previously employed to increase the imaging frame rate in ultrasonic imaging. However, the image quality in FT-based parallel reconstruction is degraded because differences in range focusing delays are ignored and a wide transmit beam...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460302500201

    authors: Li ML,Li PC

    更新日期:2003-04-01 00:00:00

  • Acoustic Structure Quantification Analysis of the Thyroid in Patients with Diffuse Autoimmune Thyroid Disease.

    abstract::The aim of this study was to assess whether acoustic structure quantification (ASQ) can differentiate normal from pathological thyroid parenchyma in patients with diffuse autoimmune thyroid disease (AITD). We evaluated 83 subjects (72 [87%] women and 11 [13%] men) aged 19 to 94 years with a mean age of 53 years. We pe...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615580766

    authors: Zandieh S,Bernt R,Zwerina J,Haller J,Knoll P,Seyeddain O,Mirzaei S

    更新日期:2016-03-01 00:00:00

  • Breast tissue classification using diagnostic ultrasound and pattern recognition techniques: II. Experimental results.

    abstract::The methods of statistical pattern recognition have been applied to the problem of in vivo ultrasonic characterization of breast disease in humans. Backscattered A-mode signals obtained from a commercial pulse imaging system were used to generate a large set of potentially useful features. Using statistical tests, a s...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468300500107

    authors: Finette S,Bleier AR,Swindell W,Haber K

    更新日期:1983-01-01 00:00:00

  • A scalable architecture for real-time synthetic-focus imaging.

    abstract::A scalable architecture for forming real-time synthetic focus images is described and the design of a 256-channel system using currently-available technology is presented as an example implementation of the architecture. The parallelism of the system scales directly with the number of array elements and the image comp...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173460302500303

    authors: Richard WD

    更新日期:2003-07-01 00:00:00

  • Effects of transmit focusing on finite amplitude distortion based second harmonic generation.

    abstract::Generation of the second harmonic signal was studied for finite amplitude distortion based harmonic imaging. Acoustic field amplitudes along the range axis of a fixed focus transducer were measured using a PVDF needle hydrophone. Results indicated that on-axis amplitudes strongly depended on the f-number at both the f...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469902100401

    authors: Li PC,Shen CC

    更新日期:1999-10-01 00:00:00

  • Attenuation and backscatter estimation using video signal analysis applied to B-mode images.

    abstract::Most methods for in vivo quantitation of ultrasound attenuation and backscatter are not available clinically because they rely upon acquiring and analyzing radio frequency (rf) echo signals. This paper describes a technique to estimate ultrasound attenuation and backscatter from B-mode image data. The video signal ana...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469701900305

    authors: Knipp BS,Zagzebski JA,Wilson TA,Dong F,Madsen EL

    更新日期:1997-07-01 00:00:00

  • A comparison method for mean frequency estimators for Doppler ultrasound.

    abstract::Mean frequency estimators as used in pulsed Doppler ultrasound equipment should provide an accurate (quality) and consistent (robustness) estimate over a wide range of signal conditions. In a simplified signal model, the main parameters to consider are the noise level, mean frequency, bandwidth and power of both the D...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469201400404

    authors: Brands PJ,Hoeks AP

    更新日期:1992-10-01 00:00:00

  • Ultrasound velocity in fixed human liver: empirical anova and regression modelling on histologically assessed abnormalities.

    abstract::Anova and "dummy variables" least squares regression methods are used to investigate the dependence of ultrasound propagation velocity on the presence or absence of fat and on the rank ordered level of cirrhosis in fixed human liver. Cirrhosis is found to affect velocity in a nonlinear fashion, while fat depresses the...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468300500306

    authors: Zimmermann KP,Smith JC

    更新日期:1983-07-01 00:00:00

  • Deconvolution of in-vivo ultrasound B-mode images.

    abstract::An algorithm for deconvolution of medical ultrasound images is presented. The procedure involves estimation of the basic one-dimensional ultrasound pulse, determining the ratio of the covariance of the noise to the covariance of the reflection signal, and finally deconvolution of the rf signal from the transducer. Usi...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469301500204

    authors: Jensen JA,Mathorne J,Gravesen T,Stage B

    更新日期:1993-04-01 00:00:00

  • GPU-accelerated Kernel Regression Reconstruction for Freehand 3D Ultrasound Imaging.

    abstract::Volume reconstruction method plays an important role in improving reconstructed volumetric image quality for freehand three-dimensional (3D) ultrasound imaging. By utilizing the capability of programmable graphics processing unit (GPU), we can achieve a real-time incremental volume reconstruction at a speed of 25-50 f...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734616689464

    authors: Wen T,Li L,Zhu Q,Qin W,Gu J,Yang F,Xie Y

    更新日期:2017-07-01 00:00:00

  • Characterization of tongue shape.

    abstract::Mathematical techniques are described for analyzing tongue shapes obtained with ultrasound images. The surface of the mid-sagittal section of the tongue was approximated by discrete points. In turn, these points were used to approximate position, slope and curvature of the tongue surface at a fixed time during speech....

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173468400600104

    authors: Morrish KA,Stone M,Sonies BC,Kurtz D,Shawker T

    更新日期:1984-01-01 00:00:00

  • Dispersion and shear modulus measurements of porcine liver.

    abstract::A narrow-band ultrasonic shear-wave imaging technique for estimating phase speed was applied to fresh and thermally damaged porcine liver in vitro. Two constitutive models were applied to the measurements to represent rheological behavior of the tissue and estimate the complex shear modulus at frequencies between 50 a...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173461003200405

    authors: Orescanin M,Qayyum MA,Toohey KS,Insana MF

    更新日期:2010-10-01 00:00:00

  • Variance and covariance of accumulated displacement estimates.

    abstract::Tracking large deformations in tissue using ultrasound can enable the reconstruction of nonlinear elastic parameters, but poses a challenge to displacement estimation algorithms. Such large deformations have to be broken up into steps, each of which contributes an estimation error to the final accumulated displacement...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734613479246

    authors: Bayer M,Hall TJ

    更新日期:2013-04-01 00:00:00

  • Reduction of the clutter component in Doppler ultrasound signals based on singular value decomposition: a simulation study.

    abstract::In pulsed Doppler ultrasound systems, the ultrasound radiofrequency (RF) signals received can be employed to estimate noninvasively the time-dependent blood velocity distribution within and artery. The RF signals are composed of signals originating from clutter (e.g., vessel walls) and scatterers (e.g., red blood cell...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469701900101

    authors: Ledoux LA,Brands PJ,Hoeks AP

    更新日期:1997-01-01 00:00:00

  • Breast-lesion Segmentation Combining B-Mode and Elastography Ultrasound.

    abstract::Breast ultrasound (BUS) imaging has become a crucial modality, especially for providing a complementary view when other modalities (i.e., mammography) are not conclusive in the task of assessing lesions. The specificity in cancer detection using BUS imaging is low. These false-positive findings often lead to an increa...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/0161734615589287

    authors: Pons G,Martí J,Martí R,Ganau S,Noble JA

    更新日期:2016-05-01 00:00:00

  • Transducer characterization from pressure amplitude distribution measurements using a Kalman filter as parameter estimation algorithm.

    abstract::The amplitude and frequency contents of a received ultrasound pulse depends on the spatial pressure amplitude distribution of the sound field, as produced by the transducer in the medium, and on the position and orientation of the reflecting surface in this field. Often, the geometry of the reflecting surface and the ...

    journal_title:Ultrasonic imaging

    pub_type: 杂志文章

    doi:10.1177/016173469001200405

    authors: Linssen FM,Hoeks AP