Abstract:
:Generation of the second harmonic signal was studied for finite amplitude distortion based harmonic imaging. Acoustic field amplitudes along the range axis of a fixed focus transducer were measured using a PVDF needle hydrophone. Results indicated that on-axis amplitudes strongly depended on the f-number at both the fundamental and the second harmonic frequencies. Differences of the on-axis amplitudes between the two frequencies were also investigated. To explore the possibility of increasing harmonic generation by extending the depth of focus, a two-focus transducer was employed. Hydrophone measurements, pulse-echo imaging and simulations were performed. Although the increase in harmonic generation depended on specific imaging parameters, the effectiveness of improving the harmonic signal-to-noise ratio (SNR) by increasing the depth of field was clearly demonstrated. Degradation in contrast resolution associated with the two-focus transducer was also evaluated. It was found that the contrast resolution was still significantly better than that of the fundamental image at the same frequency. Results of the study using the two-focus transducers can be generalized to imaging systems with full dynamic transmit focusing capabilities. In other words, it is expected that dynamic transmit focusing can improve the SNR of finite amplitude distortion based second harmonic imaging while improving the contrast resolution over fundamental imaging.
journal_name
Ultrason Imagingjournal_title
Ultrasonic imagingauthors
Li PC,Shen CCdoi
10.1177/016173469902100401subject
Has Abstractpub_date
1999-10-01 00:00:00pages
243-58issue
4eissn
0161-7346issn
1096-0910journal_volume
21pub_type
杂志文章abstract::Breast ultrasound (BUS) imaging has become a crucial modality, especially for providing a complementary view when other modalities (i.e., mammography) are not conclusive in the task of assessing lesions. The specificity in cancer detection using BUS imaging is low. These false-positive findings often lead to an increa...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615589287
更新日期:2016-05-01 00:00:00
abstract::In pulsed Doppler ultrasound systems, the ultrasound radiofrequency (RF) signals received can be employed to estimate noninvasively the time-dependent blood velocity distribution within and artery. The RF signals are composed of signals originating from clutter (e.g., vessel walls) and scatterers (e.g., red blood cell...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469701900101
更新日期:1997-01-01 00:00:00
abstract::Attenuation measurements of various tissue mimicking phantoms and three different groups of patients were obtained using a modified commercial sector scanner. Estimates of attenuation were made using the spectral shift method with mean frequencies at different depths of a region of interest being obtained by both zero...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468400600402
更新日期:1984-10-01 00:00:00
abstract::The aim of this study was to identify independent risk factors for thyroid cancer, establish an ultrasonographic multimodality diagnostic model for thyroid nodules, and explore the diagnostic value of the model. From November 2011 to February 2015, 307 patients with a total of 367 thyroid nodules underwent conventiona...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734618815070
更新日期:2019-03-01 00:00:00
abstract::A scalable architecture for forming real-time synthetic focus images is described and the design of a 256-channel system using currently-available technology is presented as an example implementation of the architecture. The parallelism of the system scales directly with the number of array elements and the image comp...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460302500303
更新日期:2003-07-01 00:00:00
abstract::Tissues exhibiting quasi-periodic structures can be modeled as a collection of diffuse scatterers and coherent scatterers. The mean scatterer spacing (MSS) of coherent and quasi-periodic components is directly related to tissue microstructure and has become an important quantitative ultrasound (QUS) parameter in the c...
journal_title:Ultrasonic imaging
pub_type: 杂志文章,评审
doi:10.1177/0161734617692018
更新日期:2017-09-01 00:00:00
abstract::The potential of using the phase derivative (PD) for echographic imaging was investigated. The PD data were calculated by four methods: zero crossing (ZCS) with squelch addition, analytic signal either with squelch addition (ASS) or with employment of a Wiener kernel (ASW), and unwrapped phase (UWP). The large peaks w...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468700900301
更新日期:1987-07-01 00:00:00
abstract::Anova and "dummy variables" least squares regression methods are used to investigate the dependence of ultrasound propagation velocity on the presence or absence of fat and on the rank ordered level of cirrhosis in fixed human liver. Cirrhosis is found to affect velocity in a nonlinear fashion, while fat depresses the...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468300500306
更新日期:1983-07-01 00:00:00
abstract::It may be possible to diagnose and monitor scarring, inflammation and edema in transplant kidney using reconstructive ultrasound elasticity imaging. Kidney elasticity is expected to change dramatically with scar, and to a lesser degree, with acute inflammation and edema. The hypothesis that changes in kidney elasticit...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460002200303
更新日期:2000-07-01 00:00:00
abstract::For a class of scattering objects the mean separation between the scatterers is determined. Over a range of frequencies, ultrasonic back-scattered pressure signals are recorded. It is suggested to derive the mean spacing of an unknown scattering object by employing Fourier analysis and comparing the signal with signal...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468300500405
更新日期:1983-10-01 00:00:00
abstract::This paper describes a method for overcoming motion artifacts in synthetic aperture imaging. The method is based on a computer simulation study on the influence of target motion on synthetic aperture techniques. A region-based motion compensation approach is used in which only the axial motion is estimated and compens...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460202400202
更新日期:2002-04-01 00:00:00
abstract::Hall effect imaging is an ultrasound-based method of mapping spatial variations in the dielectric constants of an acoustically-uniform sample. This paper presents three-dimensional Hall effect images of phantoms obtained by scanning a single transducer across a two-dimensional grid, effectively simulating two-dimensio...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469902100303
更新日期:1999-07-01 00:00:00
abstract::Experimental work using a quantitative C-scan technique to measure in situ enhancement of hepatic backscatter resulting from the administration of gelatin microspheres to dogs is reported. We have found that reproducible enhancement of hepatic backscatter on the order of 2 dB followed the peripheral administration of ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468500700402
更新日期:1985-10-01 00:00:00
abstract::When modeling or simulating an ultrasonic pulse-echo system it is necessary to know the transducer waveforms that are the input to the system. In general, accurate transducer modeling is complex and waveform calculation is computationally intensive. Because of this, investigators often assume these waveforms to be sim...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468700900405
更新日期:1987-10-01 00:00:00
abstract::Time reversal of ultrasonic field allows a very efficient approach to focusing pulsed ultrasonic waves through lossless inhomogeneous media. Time reversal mirrors (TRM) are made of large transducer arrays, allowing the incident acoustic field to be sampled, time reversed and re-emitted. Time reversal processing permit...
journal_title:Ultrasonic imaging
pub_type: 杂志文章,评审
doi:10.1177/016173469601800202
更新日期:1996-04-01 00:00:00
abstract::Tracking large deformations in tissue using ultrasound can enable the reconstruction of nonlinear elastic parameters, but poses a challenge to displacement estimation algorithms. Such large deformations have to be broken up into steps, each of which contributes an estimation error to the final accumulated displacement...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734613479246
更新日期:2013-04-01 00:00:00
abstract::The aim of this study was to assess whether acoustic structure quantification (ASQ) can differentiate normal from pathological thyroid parenchyma in patients with diffuse autoimmune thyroid disease (AITD). We evaluated 83 subjects (72 [87%] women and 11 [13%] men) aged 19 to 94 years with a mean age of 53 years. We pe...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615580766
更新日期:2016-03-01 00:00:00
abstract::In recent years, adaptive minimum-variance (MV) beamforming has been successfully applied to medical ultrasound imaging, resulting in simultaneous improvement in imaging resolution and contrast. MV has high resolution and hence can provide accurate estimates of the target locations. However, the MV amplitude estimates...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734615600167
更新日期:2016-07-01 00:00:00
abstract::An adaptive scan sequence is proposed for real-time ultrasound three-dimensional (3-D) imaging. Generally, the refresh rate of 3-D imaging is limited by the view window, resolution and sound speed in the human body. If the object is transformed or moved during the data set acquisition, the 3-D image will be distorted....
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460302500401
更新日期:2003-10-01 00:00:00
abstract::In this work, we study linear array beamforming for vibro-acoustography systems. The goal of this research is to assess the feasibility of vibro-acoustography imaging systems based on linear arrays for clinical applications. The vibro-acoustography transducer is designed with two arrays driven by two continuous-wave o...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460402600101
更新日期:2004-01-01 00:00:00
abstract::Behavior and limitations of the sinc basis method have been discovered during simulation studies. An iterative row-action method (ART) is compared with a full-matrix, least-squares solution (QR decomposition) and the problem of multiple solutions is discussed. Knowledge of the spatial distribution of scattered field e...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173468901100103
更新日期:1989-01-01 00:00:00
abstract::Muscle fatigue often occurs over a long period of exercise, and it can increase the risk of muscle injury. Evaluating the state of muscle fatigue can avoid unnecessary overtraining and injury of the muscle. Ultrasound imaging can non-invasively visualize muscle tissue in real-time. Image entropy is commonly used to ch...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734620952683
更新日期:2020-11-01 00:00:00
abstract::Regional anesthesia is preferred over general anesthesia for many surgical procedures; however, challenges associated with poor image guidance limit its widespread acceptance as a viable alternative. In B-mode ultrasound images, the current standard for guidance, nerves can be difficult to visualize due to their simil...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173460903100303
更新日期:2009-07-01 00:00:00
abstract::Acoustic radiation force (ARF) has become a common excitation mechanism in elasticity imaging. The high acoustic intensities and subsequent generation of harmonics, however, hamper the effectiveness of using conventional radiofrequency (rf) tracking to investigate the dynamics of tissues and catheter-based transducers...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:
更新日期:2009-01-01 00:00:00
abstract::Two-dimensional echocardiography (2-D echo) imaging is a more attractive clinical tool than other modalities that either involve radiation exposure or are too slow to image heart motion in real-time. Computer-aided analysis of left ventricular(LV) wall motion provides quantitative parameters for diagnosis. This study ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469701900204
更新日期:1997-04-01 00:00:00
abstract::Peripheral artery disease is often asymptomatic, and various imaging and nonimaging techniques have been used for assessment and monitoring treatments. This study is designed to demonstrate the ability of photoacoustic imaging to noninvasively determine changes in tissue oxygenation that occur in mice's hind limb skel...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/0161734619862287
更新日期:2019-09-01 00:00:00
abstract::This paper addresses significant sources of electromagnetic noise in Hall effect imaging. Hall effect imaging employs large electrical pulses for signal generation and high sensitivity ultrasonic probes for signal reception. Coherent noise arises through various coupling mechanisms between the excitation pulse and the...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469802000305
更新日期:1998-07-01 00:00:00
abstract::Statistical pattern recognition procedures allow a quantitative description of ultrasound-B-scan image texture. According to well-established animal models, different types of fatty liver disease were induced in female Wistar rats. For the correlation of the computerized ultrasound image with its underlying histology ...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469001200302
更新日期:1990-07-01 00:00:00
abstract::An autoregressive (AR) spectral estimation method was considered for the purpose of estimating scatterer size images. The variance and bias of the resulting estimates were compared with those using classical FFT periodograms for a range of input signal-to-noise ratios and echo-signal durations corresponding to various...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469601800102
更新日期:1996-01-01 00:00:00
abstract::In medical ultrasound imaging, two-dimensional (2-D) array transducers are desirable to implement dynamic focusing and phase aberration correction in two dimensions as well as volumetric imaging. Unfortunately, the small size of a 2-D array element results in a small clamped capacitance and a large electrical impedanc...
journal_title:Ultrasonic imaging
pub_type: 杂志文章
doi:10.1177/016173469501700202
更新日期:1995-04-01 00:00:00